Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | W.H.Building 450 Mt & Cleaning & Grading Plant Shed Civil Work 350 SQM |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m.beyond the building area & stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering Including shoring and strutting etc. complete. (LIFT UPTO 1.5 M.) By Mechanical Means (PWD S.S.R. 22-23 Item Serial No.726 & Item No.21.02) Warehouse- 65.04 Shed- 95.22 |
| 3 | Excavation for foundation in Hard murum in cluding removing the excavated material upto adistance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means (PWD S.S.R. 22-23 Item Serial No.732 & Item No.21.08) Warehouse- 28.05 Shed- 50.78 |
| 4 | Providing dry trap/ granite/ quartzite/ gneiss rubble stone soiling 15 cm to 20 cm thick including hand packing and compacting complete. Spec.No. : Bd.A.12 Page No. 264 ; (PWD S.S.R. 22-23 Item Serial No.757 & Item No.21.38) Warehouse- 64.38 Shed- 91.12 |
| 5 | Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layersincluding watering and compacting etc. complete. (PWD S.S.R. 22-23 Item Serial No.755 & Item No.21.36) Warehouse- 93.09 Shed- 41.92 |
| 6 | Filling in plinth and floors with contractors material/ brought from outside and approved by Engineer in charge in layers of15 cm to 20 cm including watering and compaction etc.complete. (PWD S.S.R. 22-23 Item Serial No.756 & Item No.21.37) Warehouse- 70.79 Shed- 256.18 |
| 7 | Providing and filling in the foundation with sand of approved quality including watering, compacting etc. complete. (PWD S.S.R. 22-23 Item Serial No.758 & Item No.21.39) Warehouse- 1.89 |
| 8 | Providing and laying Cast in situ/ Ready Mix cement concrete in M-10 of trap/granite/quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete ,with fully automatic microprocess or base dPLCwith SCADA enable dreversible Drum Type mixer/ concrete Batch mix plant (Panmixer) etc.complete. With fine aggregate (Crushed sand VSI Grade) (PWD S.S.R. 22-23 Item Serial No.732 & Item No.24.01) Warehouse- 27.79 Shed- 41.35 |
| 9 | Providing and laying in situ cement concrete of M-20 grade of trap / granite/quartzite/gneiss metal for R.C.C. work like raft, grillages, strips, foundations and footings of R.C.C.columns and steel stanchions including bailing-out water manually, including centering formwork of plywood / steel, compaction, covering newly laid concrete by gunny bag, plastic or tarpaulin, finishing the formed surface with cement morter 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc complete. (Excluding reinforcement) The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. (Wooden planks / shuttering will not be allowed) Spec.No.:Bd.F.2 Page No. 298 /IS 456 (1978) (PWD S.S.R. 22-23 Item Serial No.841 & Item No.25.11) Shed- 28.80 |
| 10 | Providing and laying in situ cement concrete of M-25 grade of trap / granite/quartzite/gneiss metal for R.C.C. work like raft, grillages, strips, foundations and footings of R.C.C.columns and steel stanchions including bailing-out water manually, including centering formwork of plywood / steel, compaction, covering newly laid concrete by gunny bag, plastic or tarpaulin, finishing the formed surface with cement morter 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc complete. (Excluding reinforcement) The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. (Wooden planks / shuttering will not be allowed) Spec.No.:Bd.F.2 Page No. 298 /IS 456 (1978) (PWD S.S.R. 22-23 Item Serial No.841 & Item No.25.11) Warehouse- 12.55 |
| 11 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (PWD S.S.R. 22-23 Item Serial No.846 & Item No.25.31) Shed- 8.95 |
| 12 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (PWD S.S.R. 22-23 Item Serial No.846 & Item No.25.31) Warehouse- 9.94 |
| 13 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (PWD S.S.R. 22-23 Item Serial No.851 & Item No.25.50)Shed- 14.62 |
| 14 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (PWD S.S.R. 22-23 Item Serial No.851 & Item No.25.50)Warehouse- 16.13 |
| 15 | Providing and laying in situ cement concrete of M-20 grade of trap / granite/quartzite/gneiss metal for R.C.C. work like raft, grillages, strips, foundations and footings of R.C.C. Finx and steel stanchions including bailing-out water manually, including centering formwork of plywood / steel, compaction, covering newly laid concrete by gunny bag, plastic or tarpaulin, finishing the formed surface with cement morter 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc complete. (Excluding reinforcement) The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. (Wooden planks / shuttering will not be allowed) Spec.No.:Bd.F.2 Page No. 298 /IS 456 (1978)) Warehouse- 1.74 |
| 16 | Providing and casting in situ cement concrete of M-25 grade of trap granite / quartzite / gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings or as directed including fixing plastic cover block of requird size at 27 Nos in per 10 Sqm to reinforcement to give a clear cover of 15mm in RCC slabs, fixing fan hook box of 100mm diameter PVC or MS material with required depth with holes or notches as required, bottom with 12mm diameter M.S. bar bend to shape with hooked ends for fan hook and painting to exposed surface, centering, formwork of steel, compaction, covering newly laid concrete by gunny bag, plastic or tarpaulin, finishing the formed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed). Bd.F.8 Page No. 302 / IS 456:2000 (PWD S.S.R. 22-23 Item Serial No.856 & Item No.25.70) warehouse- 1.28 |
| 17 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (PWD S.S.R. 22-23 Item Serial No.876 & Item No.26.33)Warehouse-3Shed- 4.19 |
| 18 | Providing dry rubble stone pitching 23cm (about 9) thick including all material, quarry spalls, labour etc.complete. (PWD S.S.R. 22-23 Item Serial No.109 & Item No.2.34) Warehouse-28.45 |
| 19 | Providing Brick masonry in cement mortal 1.6 using second Class Burnt Bricks in foundation and plinth of inner walls/ in plinth of external walls including bailing out water manually, striking joints on unexposed faces ,watering and scaffolding complete Bd. G. 1, Page No.313, (PWD S.S.R. 22-23 Item Serial No.894 & Item No.27.01) Warehouse-6.76 Shed-6.50 |
| 20 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete. (PWD S.S.R. 22-23 Item Serial No.897 & Item No.27.05) Warehouse-55.56 Shed-29.22 |
| 21 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (PWD S.S.R. 22-23 Item Serial No.968 & Item No.32.11) Warehouse-818.26 Shed-253.02 |
| 22 | Providing and fixing steel ventilat or fully glazed partly fixed as per detailed drawing with hot dip zinc coating including fabricating glazing with plain/ obscured glass pans 5mm thick and approved type quality and iron oxidized fixtures and fastening with guards quare bars 12mm 10cmc /cand oil painting 2coats etc. complete. (PWD S.S.R. 22-23 Item Serial No.1228 & Item No. 39.30) Warehouse-23.62 |
| 23 | Providing and applying white-wash in one coat on old/ new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. (PWD S.S.R. 22-23 Item Serial No.1102 & Item No. 36.02) Warehouse-818.26 Shed-253.02 |
| 24 | Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat) etc. complete. (PWD S.S.R. 22-23 Item Serial No.1112 & Item No. 36.12) Warehouse-818.26 Shed-253.02 |
| 25 | Providing internal cement plaster 20mm thick in two coats in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing complete.(PWD S.S.R. 22- 23 Item Serial No.967 & Item No.32.08) Shed- 174.27 |
| 26 | Providing neeru finish to plastered surfaces in all position s including scaffolding and curing etc. complete.(PWD S.S.R. 22-23 Item Serial No.971 & Item No.32.15) Shed - 174.27 |
| 27 | Providing and applying primer coat for internal wall surfaces and ceilings including scaffolding etc. complete.(PWD S.S.R. 22-23 Item Serial No.1095 & Item No.35.21) Shed - 174.27 |
| 28 | Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. (PWD S.S.R. 22-23 Item Serial No.1111 & Item No.36.11)Shed - 174.27 |
| 29 | Providing and fixing rolling shutter fabricated from steell at hsofminimum thickness 0.9mm with lock plate of 3.15 mm thickness reinforced with 35x35x5mm angle section fitted with sliding bolts and handles for both sides, deep M.S.channel section of depth and thickness not less than 65mm and 3.15mm respectively with hold fastarr angements, M.S.Bracket plate 300x300x3.15mm minimum size and shape with square bar, suspension shaft of minimum 32mm diameter, hood cover of M.S. sheet not less than 0.9mm thickness and of any size attopand safety device sincluding mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade castir on or mild steel and one coat of redlead primer etc. complete.(I.S.62481979) (Without mechanical gear) (PWD S.S.R. 22- 23 Item Serial No.1222 & Item No. 39.24) Shed- 15 |
| 30 | Providingandfixingsteelwindowofvarioussizesasperdetaileddrawingwithouthotdipzinccoating,withoutventilators,includingfabricating/glazingwithplain/obscuredglasspanelsofapprovedtypeandquality,ironoxidisedfixturesandfastenings,finishingwithoilpaintingtwocoatscomplete(withguardbars12mmsquareat10cmc/c.) (PWD S.S.R. 22-23 Item Serial No.1218 & Item No.39.20) Shed- 10.80 |
| 31 | Providing and fixing rolling shutter fabricated from steell at hsofminimum thickness 0.9mm with lock plate of 3.15 mm thickness reinforced with 35x35x5mm angle section fitted with sliding bolts and handles for both sides, deep M.S.channel section of depth and thickness not less than 65mm and 3.15mm respectively with hold fastarr angements, M.S.Bracket plate 300x300x3.15mm minimum size and shape with square bar, suspension shaft of minimum 32mm diameter, hood cover of M.S. sheet not less than 0.9mm thickness and of any size attopand safety device sincluding mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade castir on or mild steel and one coat of redlead primer etc. complete.(I.S.62481979) (Without mechanical gear) (PWD S.S.R. 22-23 Item Serial No.1222 & Item No. 39.24) Warehouse- 10.50 |
| 32 | Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete. (PWD S.S.R. 22-23 Item Serial No.1022 & Item No. 33.30) Warehouse-233.18 Shed-332.72 |
| 33 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anti corrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. (PWD S.S.R. 22-23 Item Serial No.824 & Item No. 23.04) Warehouse-3.52 |
| 34 | Providing and fixing colour coated Zincalume (R) AZ 150 (min150 gms /sq.mt. total on each side) profiled sheets for roofing. The feed materialis manufactured out of nominal 0.45mm Base Metal Thickness (BMT) (0.5mm TCT), Hi- strength steel with min. 550 MP a yield strength, metallic hot dip coated with Aluminium- Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLOR BOND (R) steel quality super durable polyester paint coat (with in organic pigment). The paint shall have a total coating thickness of nominal 35um, comprising of nominal 25 um exterior coat on top surface and nominal 10um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtles quare flutingin the five panat nominal 180-250 mm center-to-center. The endrib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25um Zinc-Tinalloy coated, Hexhead, self-drilling screw etc. complete. (weight of profile 4.52Kilogram / Square Metre ). (PWD S.S.R. 22-23 Item Serial No.1179 & Item No. 38.34) Warehouse-292.04 |
| 35 | Providing and fixing UPVC Roof made up of 3 layers roofing material of thickness 2mm having width of 1130mm and of required Length having Tensile strength not less than 330Kilo gram/ cm2, including fastening with self drilling screw having washers made of stainless steel etc. complete. (PWD S.S.R. 22-23 Item Serial No.1182 & Item No. 38.37) Warehouse-13.80 |
| 36 | Shed PEB Work |
| 37 | Supplying, fabricating, erecting and fixing in position of steel structures at all elevations using fusion welding quality steel E-350 (Fe490) conforming to IS:2062 - 2006. Rate shall include cost of cutting, welding, splice plates and packing plates, transporting, straightening, cleaning,fabricating anderecting inposition welded/bolted Structural steelwork in columns, beams, trusses, purlins, platforms, ladders, monorails, staircases ,supports, strengthening of steel members etc. at site to line and level, supply of approved bolts/nuts/washers etc. complete as per drawings including painting as per G4/G5/G6 before erection and all materials and labour charges etc., complete and including Sand blasting & painted with 1 coats of enamel paint (Berger EPILUX SG – HHI 664002) of 35-50 micron each coat with air less spray gun over a coat of zinc chromate primer - 35-50 micron etc., complete as shown in drawings, as per specifications and as directed by the Engineer-in-Charge / Construction Manager. (The rate quoted shall include cost of bolts, nuts, washers, welding and electrodes required for the complete work). (Mecanical SSR 2022-23) Shed- 10.90 |
| 38 | Supplying, fabricating and erecting of Cold Formed Light Gauge structural steel members conforming to IS:801/ IS:811 hot-dip galvanised to IS:4759 - 96 including cutting, welding or bolting, splice plates and packing plates, transporting, straightening, cleaning, fabricating and erecting in position. (Mecanical SSR 2022-23) Shed- 4.87 |
| 39 | Supply & Fixing of PPGI sheets of 0.5 mm thick as shown in drawing orasdirectedbyengineerinchargewithallnecessary accessories.(Essar) Make) (Mecanical SSR 2022-23) Shed- 714.48 |
| 40 | Supply & Fixing of 0.5 mm thk PPGL roof accessories as per drawing or as directed by engineer in charge. (Mecanical SSR 2022-23) Shed-73.20 |
| 41 | Supplying, fabricating and erecting in position PPGI Eaves Gutter of required size with stop ends,all fixing accessories, drop ends, etc., at all elevations levels & heights including aligning, leveling, providing and fixing bolts, nuts, washers etc., conforming to latest specification including straightening, cutting, welding, bending to shape, bolting etc., complete and as directed as per engineer incharge (Mecanical SSR 2022-23) |
| 42 | Providing and fixing of the rain water down take pipes of PPGI, the sectional area of rain water down take pipes provided shall be generally at the rate of 1 square cm per 70 to 80 square decimetre of roof area drained. No spout shall be less than 80 mm in diameter. The spacing of spouts shall be arranged to suit the position of openings in the wall including necessary accessories for fixing the pipe and including all materials and labour charges etc., complete as shown in drawings, as per specifications and as directed by the Engineer-in-Charge (Mecanical SSR 2022-23) Shed- 43.80 |
| 43 | Supply & Fixing of turbo ventilator with 610 mm throat, having base ring & top plate in stainless steel of 0.8 mm thick, rotated using twin bearings of SKF - 600122 & 600322 permanently lubricated & sealed. Fixed in FRP base plate of 2mm thk clear 1.020 mtr wide & 1.7 mtr long. (Mecanical SSR 2022-23) Shed- |
| 44 | Supply & Fixing of 2mm thk polycarbonate sheets as per drawing & as directed by engineer in-charge. (Mecanical SSR 2022-23) |
| 45 | Internal Bituminous roads |
| 46 | Clearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the area. (PWD S.S.R. 22-23 Item Serial No.85 & Item No.2.07) |
| 47 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mm Aggregate) (PWD S.S.R. 22-23 Item Serial No.129 & Item No.3.18) |
| 48 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II (Using Screening Type B (11.2 mm) Aggregate) (PWD S.S.R. 22-23 Item Serial No.131 & Item No. 3.20) |
| 49 | Providing and constructing 75 mm. thick Modified Penetration Macadam (MPM) road surface including all materials, preparing the existing road surface, spreading 40 mm. stone metal layers 100% crusher broken metal with conical crusher plant heating and spraying the bitumen of specified grade @ 2ilogram/Square Metre, spreading 12 mm.size chips compacting with three wheel static roller having weight 8 to 10 MT. to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete. (VG-30 bulk bitumen ) (PWD S.S.R. 22-23 Item Serial No.146 & Item No.3.35a) |
| 50 | Open Graded Premix Surfacing- Providing and Laying OGC 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates premixed with bituminous binder @1.56 Kg/Sqm transported to site with VTS, laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction but excluding prime / tack and Seal coat. For Bitumen of specified grade--USING drum mix type hot mix plant, Paver and Vibratory roller ( Over MPM Surface) (VG-30 bulk Grade 60/70) (PWD S.S.R. 22-23 Item Serial No.168 & Item No.4.12) |
| 51 | 9 MM SEAL COAT: Providing and laying of Type A 9 mm premix seal coat with HMP of Sqm apropriate capacity crushed stone chiping 6.7 mm size and penetration bitumen of specified grade @ 1.2 kg/Sq.m, preparing existing road surface by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 MT etc. complete. (VG-30 bulk Grade 60/70) (PWD S.S.R. 22-23 Item Serial No.161 & Item No.4.01) |
| 52 | Supplying hard murum/ kankar at the road site, including conveying and stacking complete. (PWD S.S.R. 22-23 Item Serial No.103 & Item No.2.29a) |
| 53 | Spreading hard murum/ soft murrum/ gravel or kankar for side width complete. (PWD S.S.R. 22-23 Item Serial No.105 & Item No.2.30) |
| 54 | Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete. (PWD S.S.R. 22-23 Item Serial No.106 & Item No.2.31) |
| 55 | Electrification |
| 56 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 7-1-9 |
| 57 | Making trench in soft soil having 0.75 m depth and minimum0.3 m width for laying provided cables up to voltage level of1.1kV complete As per specification No. CW-EXN-CTR 16- 1-1 |
| 58 | Making trench in Hard murum/Tar road having 0.75 m depth and minimum 0.3mtr width as per IS for laying provided cables up to voltage level 1.1Kv cable complete as per specification No. CW-EXN-CTR 16-1-2 |
| 59 | Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 1-3-6 |
| 60 | Supplying & erecting CRCA sheet metal enclosures of1.2mm thickness with 10A, 2 pin plug & earth socket and 10A, 3 pin plug top with 10A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame. 5-4-10 |
| 61 | Point wiring for light/fan/bell in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification No: WG-PW/SW 1-7-3 |
| 62 | Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 /E-27 base. 2-8-11 |
| 63 | Supplying and erecting integrated LED street light fitting 18 to 22W IP65 & IK08 class having single piece pressure die- cast aluminium housing,having system lumens output of Min. 1800 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140- 270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FGODF/ FLS2. 2-4- |
| 64 | Supplying and erecting Street light bracket made from 40mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC 2-7-2 |
| 65 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP 9-1-1 |
| 66 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP 9-1-4 |
| 67 | Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW- SWR/MCB5-3-6 |
| 68 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW- SWR/MCB 5-3-3 |
| 69 | Supplying and erecting GI sheet 1.6 mm (16 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. 6-1-6 |
| 70 | Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010 6- 1-14 |
| 71 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no.SW-SWR/MCBDB1 5-4-15 |
| 72 | Supplying & erecting G.I. pipe ‘A’ class 25 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE 7-6-1 |
| 73 | Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE 7-6-2 |
| 74 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 7-6-10 |
| 75 | Supplying & erecting single compression type brass cable glands for 3 to 4 core 6 sq mm /2 to 4 core 10 sq mm for XLPE armoured cable as per specification No.CB-GL 7-7-2 |
| 76 | Supplying and erecting Ceiling rose / Batten holder / Slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box. 1- 5-7 |
| 77 | Point wiring for independent plug in 20 mm metal conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW 1-7-2 |
| 78 | Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/ CW 1- 7-26 |
| 79 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW 1-3-2 |
| 80 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW 1-3-3 |
| 81 | Supplying and erecting modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. 1-6-8 |
| 82 | Supplying, erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc.in provided distribution board. 5-3-14 |
| 83 | Supplying & erecting 3W, 230V integral type LED Lamp suitable for B-22 / E- 27 base. 2-8-9 |
| 84 | Supplying and erecting IP65 and IK08 rated UV shielded polycarbonate waterproof and dustproof industrial grade LED fitting (4 feet) max. 36W with high transitivity diffuser with system lumens output of min. 4300 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50 , IP20 rated, including driver with auto cutoff & auto restart feature at 325V with end caps on PVC lock/wooden board with 3 years warranty. 2-2-1 |
| 85 | Supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. FG-FN/CF 2-10-2 |
| 86 | Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230VA.C. supply erected on olished double wooden block/sunmica block of suitable size. 2-3-13 |
| 87 | Supplying and erecting Street light bracket made from 25mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC 2-7-1 |
| 88 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. 5-4-13 |
| 89 | Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 40A in provided distribution board. 5-3-18 |
| 90 | W.H.BuildingROYALTY CHARGES |
| 91 | Sand ( Warehouse- 89.49 + Shed- 8.35) |
| 92 | Royalty Charges Rubble & HM ( Warehouse- 163.62 + Shed- 347.30 + Road-177.45) |
| 93 | TESTING Charges |
| 94 | Comp. Strength- Cube M10, M20, M25 each |
| 95 | Crush Metal-Basic Test Gradation |
| 96 | Cement-Fineness,consistency.Setting time,Compressive strength,Specific GravityMix design M-20 |
| 97 | Sand-Fineness Modulus,Silt Content |
| 98 | Water Absorption (Set of 5 Bricks), Compressive Strength( Set of 5 Bricks),Efflorescence (Set of 5 Bricks). |
| 99 | Murum In Plinth Plasticity Index |
| 100 | RUBBLECrushing Value/Compressive Strength, Water Absorption & Specific Gravity |
| 101 | STEELTensile strength Yield stress, ultimate tensile stress. %elongation, weight per running meter,Bend/Rebend test. (Set of 3 Bars) UP to16mm |
| 102 | Concrete Mix Design (With all Tests on basic materials) M25, M20 |
| 103 | Penetration, Softening Point, Flash & Fire Point, Specific Gravity |
| 104 | Extraction Test.(Bituminous mix) |
| 105 | Management Strategies and Implementation Plan (MSIP) to manage the Environmental, Social, Health and Safety (ESHS) risks and ESHS Code of Conduct |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy