Tender For Demolition And Re-Construction Of Smc Building At Afs Yelahanka On Epc Mode; 2 GENERAL SUMMARY NOTE: Schedule ‘A’ Part II to IX are prepriced by MES under Ser No. 2 to 9. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 3 Lumpsum price worked out by the contractor for “Site Clearance as listed in Schedule ‘A’ Part - II. 4 Lumpsum price worked out by the contractor for Road/Path/Hardstanding as listed in Schedule ‘A’ Part - III. 5 Lumpsum price worked out by the contractor for Area Drainage as listed in Schedule ‘A’ Part - IV. 6 Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – V. 7 Lumpsum price worked out by the contractor for “Fencing” as listed in Schedule ‘A’ Part – VI. 8 Lumpsum price worked out by the contractor for “External Water Supply/Hot Water Supply” as listed in Schedule ‘A’ Part – VII 9 Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part –VIII 10 Lumpsum price worked out by the contractor for “Demolition of existing buildings” as listed in Schedule ‘A’ Part – IX 11 Sch A Part - I : BUILDINGS OR WORKSDESIGN & CONSTRUCTION OF TWO STOREY (G+1)SMC BUILDING, AMBULANCE PARKING SHED AND DEMONSTRATION AREA INCLUDING ALL INTERNAL SERVICES AS DETAILED IN SCOPE OF WORK AND OTHER DOCUMENTS OF THE TENDER,COMPLETE ALL AS SPECIFIED AND SHOWN ON DRAWINGS. 12 SCHEDULE A Part- X (FITTINGS AND FIXTURES & MISC ITEMS) 13 ROADMaterial and labour for preparation of new road surfaces and applying reflective thermoplastic road marking paint (White or golden yellow) of minimum 2.50 mm thick (conforming to BIS-3262), single coat as in centre line and edge line road marking of 150/ 100mm width using HOT MARK by indigenous modern propelled road marking machine as directed including all ingredients such as binder, glass beads, titanium dioxide, calcium carbonate, inter filler as specified in table 803.4of MORTH specification,thermoplastic requirement for glass beads shall be as specified in (intermix) type-I, MOST/BS 6088Aand road marking shall done as per provisions contained in IRC-35-1997 complete all as specified and as directed. 14 FENCINGSupply and fix Stainless steel 304, 12 inch size each letter for Bilingual name board (Hindi-14 Nos letters and English-21 Nos letters) embedded in Granite on both gate complete all as specified and directed. 15 EXTERNAL WATER SUPPLYMaterial and labour for cutting existing 150mm bore water mains and inserting TEE 150mm x 100mm including necessary fittings, joints etc for connection of TEE complete all as specified and as directed. 16 Supply and fix Cast iron sluice valve flanged of class 1.0 PN, 80mm complete all as specified and as directed, 17 Supply and fix 80 mm dia cast iron body with flanged ends drilled ISI marked as per IS 14846:2000, PN 1.6 with brass spindle and check nut including operating wheel etc and fixed with flanges both end and new bolt, nuts, washers and rubber insertion packing complete all as specified and as directed. 18 EXTERNAL ELECTRIC SUPPLYReturning and filling of trenches in two parts (i) using riddled soil obtained fromexcavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and (ii)refilling the trench of remaining depthwith normal excavated soil all as specified and directed.Note: - Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning. 19 Material and labour for Boring of holes under road, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure Complete all as specified and directed. 20 Supply and installation , testing and commissioning of HT 11 KV, rated voltage 12 KV,630 Amp, 21 KA / 3 Sec outdoor type extensible internal arc 21 KA for 1 sec for Tank floor mounted with internal copper busbar, SF6 insulated completely motorized 4 way RMU consisting of 01 Nos VCB 630 Amps as incomer and 03 No 630 Amp VCB as outgoingSCADA compatible, over load and earth fault protection relaywith air insulated metering module (MFM for VCB feeders) all live parts busbar ,VCB connections of RMU shall be inclusive in one SF6 tank to avoid multiple inter connections SF6 tank shall be sealed for life robotically welded non magnetic and non ferrite stainless steel grand 304 min 2.5 mm thick having IP-67 degree of protection filled with SF6 gas has insulation with leakage rate less than 0.1% per year tested as per IEC 62271 200 I No fault passage indicator (FPI) required for complete unit manual welding or heremetic ceiling of tank shall be not accepted . The unit shall have front cable entry (suitable for termination of 1 hr x 3C 95.120/ 150 Sqmm cable) for easy of installation and shall have site replaceable bushing for easy of troubleshooting during break down. RMU should be completed with all accessories such as terminal boots, VPIS , cable supports , all front cable terminations , mechanical indications vacuum circuit breakersON/OFF, Manometer as per with IEC standards 62271200, 60056, 60129, 60265, 60298, 60420, 60529 & 60694 altitude of installation upto 1000 m as per IEC 60120bushing bolted type top monitored outside the tank for connections of external busbar also the outer includes shall cover the full length of the switchgear , to ensure IP3X + IP-54 protection for cable boxes the unit shall be internal arc proof 24 KA for 1 sec with AFLR classification tested and totally safe for human being. 21 The gas release and personnel safety from internal arc shall not dropped on plinth design the release of gas to be from the top the unit . So that even if the person is operating the unit opening the cover and there are personnel near the side of the RMU / plinth top release will ensure their safety. The hot gas release in case of an internal arc, in No of case should be from any side or bottom of the unit as the same if unsafe for operating personnel / pedestrian or general public. Bidder shall provide type test report to be prove compliance to the internal arc fault IAC-AFLR as per IEC62271-200 internal arc testing shall be done with enclosure door in open conditions , with switching devise in operations mode as per specified standard RMU.(a) 01 Nos Incoming 630 AmpsVCB,motorised vacuum circuit breaker, triple pole single break 3 position (On, Off and earth having STC capacity 21 KA for 3 seconds with copper busbar and copper earth bar fitted high fixed type voltage indicator device as per IEC61958-1 fully rated with earth switch spring assisted mechanism with built in operating handle, arc proof hinged type cable cover air insulated cable boxes and boots suitable for bottom front entry termination of 3 core cable 95/120/185 sqmm. (b) 02 Nos Outgoing 630 Amps motorised vacuum circuit breaker, triple pole single break 3 position (On, Off and earth having STC capacity 21 KA for 3 seconds with copper busbar and copper earth bar fitted high fixed type voltage indicator device as per IEC61958-1 fully rated with earth switch spring assisted mechanism with built in operating handle, arc proof hinged type cable cover air insulated cable boxes and boots suitable for bottom front entry termination of 3 core cable 95/120/185 sqmm.(c) Bus connected PT unit-01 No for metering consisting of following:- (i) Type M : Air insulated metering module 12 KV, 630 A 21 KA for 3 sec.(ii) 3 voltage transformers of the ratio 11KV/1.732/110V/1.732.25VA class 1.0 with HT fuses on primary side and MCB on secondary side. 22 (iii) 3 Digital MFM with 485 port to measure Amps, Volts, Frequency, PF, KWH, KVAR.(iv) 1 LED bulb for illumination. (v) 1 Space heater with thermostat. (vi) 1 RYB Phase indicator. (vii) 1Cable support bus bar, stand for 3 Way unit, 1 Manometer & 1 Preparing Handle. (viii)1 Set bushing for external busbar connection along with bus bar cover & sleeved bus bars for coupling. (ix) 2x12 V Battery with charger of suitable burden for motor operation, input 230 V AC & output 24 V DC.(d)Capacitive Voltage indicator fixed type VPIS 9-15 KV. (e) Necessary inter locking arrangement for safety and operation. (f)One No Operating handle for manual operation. (g) PCC 1:2:4 type B1 using 20mm graded stone aggregate for foundation and bus duct of cable for RMU as per recommendation of manufactures & as directed by Engineer-in-charge. (h) Safety interlocks shall be provided as relevant IEC/IS standard and manufactures directions. (j) Above switchgears shall confirm to all relevant IEC/IS standard.(k) Manual operation of Vacuum Circuit Breaker should be possible without dismantling the motor from RMU. The motor should be fitted in such a way that it should not be required to dismantle during manual operation.(l) Coupling of RMU and metering module should be with the help of bolted type arrangement so that the coupling at site shall be easy. Plug in type bushing shall not be acceptable.(m) Minimum 3 Module should be accommodate in one tank to avoid multiple coupling at site. (n)Having following additional facilities:-1. Trip circuit supervision. 2. Disturbance recorder. 3. Event log with date and time.4. Measurement and control feature. 23 (o) Current Transformers (CTs) of dual ratio 50/25-5A of 15 VA output, accuracy class 1.0 for metering instrument and 5P10 for 15 VA accuracy for over current and earth fault protection - sets of 03 Note:-(i) Any other parts/items not specified above but have been considered essential for smooth and safe functioning of the RMU system shall be included in the items and are covered against the quoted rate.(ii)Cable compartment shall be provided at the front side with front bolted type box covers providedwith an inspection window forenabling operator to have visual inspection without operating cover in live condition for all incoming and outgoing RMU panels.(iii) Complete with internal and external connection with each other or as per ground requirement.(iv) Drawing and Design drawing shall be submitted for approval of Accepting Officer before placing Order.Following additional equipment delivered separately or mounted in respective panel.(i) Cable support bars, standard for 4-Way unit.(ii) Manometer.(iii) Operating handle. 24 Supply and fix 7 meter high hot dipped octagonal poles with 130mm bottom dia & 70mm top dia made up of 3mm thick HT Sheet alongwith base plate of size 200x200x12mm including foundation bolts & bracket of size M20x600mm EN 8 grade J type foundation bolts and numbering of poles, in white paint over black painted back ground at a height of 1.5m from bottom of pole with 5 cm large bold letters 2 (inch) wide withetc complete as required andall as specified and directed. complete accessories as required complete all as specified and as directed. 25 Supply and fix street light fitting 72 watt LED, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection including GI Bracket of suitable size required for fixing LED light on pole along with nut and clamp complete all as specified and directed.Note :- Rates quoted by contractor are deemed to be inclusive of 3 core cable pvc insulated unsheathed copper multistranded conductor ISI marked from MCB box to street light all as specified. 26 Supply and fix pole box of size 450x 300 x 200 mm fabricated out of 2 mm thick MS Sheet having 4 Nos aluminium busbar of suitable size with 1 No. MCB SP 10 Amps front openable hinged cover outdoor type weather proof suitable for mounting on steel pole including fixing MS clamp02 Nos with nuts, bolts and washers complete all as specified and as directed. 27 Earthing complete with galvanized steel earthplate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in a pit (earth pit of depth not less than 2.25 metre below ground level) with top edge of the earth platenot less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt 15cm thick each layer and electrode connected to and includinggalvanized iron earth strip, 32 x 6 mm (earth lead) by means of bolts, nuts, check nuts and washers of galvanisedsteel protection pipe light grade 40mm dia and GI pipelight grade 20mm dia bore for watering, funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sq m) and frame including all excavation and earth work all as shown in electrical plate No 3 connected to earthing test point including testing on completion complete all as specified and as directed.Note : The unit rate includes for 40mm light grade protection pipe and GI earth strip 32 x 6mm from top of earth plate upto 7.50 metre above ground level.The earth pit shall be constructed atleast 1.5m away from the top of earth electrode. 28 Earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4mm earth lead by means of bolts, nuts check nuts and washers of galvanized iron or steel with protection pipe of GI, medium grade 15mm bore, watering pipe 20mm bore of GI medium grade, earth plate surrounded by alternate layer of coal dust and common salt 15 cm thick each layer all as per electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified or indicated and testing on completion including funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sqm) and frame including all excavation and earth work etc. including testing on completion complete all as specified and as directed. Note :(i) Earth chamber shall be constructed at least 1.50m away from the top of earth electrode.The earth pit and pipe for watering shall be provided in slanting manner.The unit rate include for GI pipes, GI earth lead from top of earth plate upto 7.50m above ground level, including PCC, RCC work etc as specified in the item. 29 Supply, installation, commissioning and testing of feeder pillar board Kiosk type floor mounted, Outdoor type, fixed type, double door openable both rear and front side, weather, dust and vermin proofand compartmentalizedMain L.T Panel(CPRI approved) made out of M.S. CRCA sheet 3.15 mm & M.S. Base Frame Angle 75x40 mm duly painted with Light/ Siemens Grey Powder Coated Paint with 900 A TPN Copper Busbar (current density of Copper Busbar shall be 1mmx1mm=1.6 Amp.)Copper shall be Electric grade, Busbar supports shall be DMC epoxy Insulators.All Busbars & Incoming/Outgoing Links shall be covered/ insulated with Heat Shrinkable sleeves ofcoloured coded red, yellow, blue & black. Power & Control Wiring withCopper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.5 sq. mm for other circuits)as per specifications. Platform for the feeder pillar board with PCC 1:2:4type B-1, 15cm thick in foundation, Brick (sub class B) work in CM 1:6 rendering in cm 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in padding on top and grouting blots etc for panel. The platform shall be 450mm height above ground level and of adequate size leaving minimum 100mm all around the feeder pillar board with following :- 30 (a)ACB 415 Volts, 630 amp, rating 4 pole 50 KA rupturing capacity, microprocessor release -01 No.(I/C)(b) MCCB 415 Volts , 250 Amp 4P , 36 KA ,microprocessor release - 01 Nos (c)MCCB 415 Volts , 160 Amp 4P , 25 KA ,microprocessor release - 02 Nos(d) MCCB 415 Volts , 125 Amp 4P , 25 KA ,microprocessor release - 02 Nos(e)MCB415 Volts , 32 Amp 2P , 10 KA ,microprocessor release - 02 Nos(f)Voltmeter 0-500V digital type with selector switch 96mmx96mm square flush mounted- 01 No.(g)ampere meter digital type of size 96mmx96mm flush mounted CTs operated including CTs 0-630A with selector switch-01 No.(h) LED type/Neon type indicating lamps panel mounting type RYB-03 Nos.(i)fine wiring with single core PVC insulated conductor FLRS wire of suitable size copper conductor cable,thimble, lugs etc for instruments/indicating lamps-01Job. 31 Supply, fixing, testing & commissioning of LT panel board of size 1.1x1.1x.5 Mtr,weather proof, outdoor type powder coated, double door shutter, made out of CRCA sheet3.15 mm thickouter and 2.00 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closedAluminium bus bar chamber including necessary insulator suitable for 3 phase, 4 wire 50 Hz AC,CPRI approved including provn of digital ammeter 0-350A,digital voltmeter 0-500 Volts, CTs of suitable ratio, indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work alsoincludes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc The bottom portion of enclosure shall be minimum 100 cm above ground level of legs of angle iron ). 32 (a) Copper bus bar capacity 900 Amps for Phase-R-Y-B-3 Nos &neutral -1 No(b) ACB FP 36 KA 630 Amps- 1 Nos(I/C) (f) Digital Ammeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No and suitable CT ratio 0-630 Amps (g) Digital Voltmeter flush pattern type square dial 96 x 96 mm alongwithselector switch - 01 No 0-500 V(h) complete control panel wiring withstranded copper conductor of suitable size along with one set indicator lamp for R,Y & B for each incoming and outgoing feeder 33 Supply and fix Post top light of capacity 45Watt offering excellent uniform illumination and aesthetic in one go , made up of pressure die cast aluminium body and open PC Cover, IP 66 and IK-07 rating suitable for tall amid varied environmental conditions and for pole of dia 76mm colour temp 3000K complete all as specified and directed. 34 Supply and fix LED Bollard Light with unique concept LED in IP 66 with sustainable performance in all section of Capacity 9W, 220V, 50 Hz CCT- 3000K, 800mm Complete all as specified and as directed. 35 Supply, erection, testing and commissioning of 16M high mast shaft in two section suitable for 44m/sec wind speed along with head frame, luminaries carriage suitable for 8 luminaries in symmetrical arrangement and other accessories manufactured in factory including Supply of raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial. (Wiring material from JB to individual luminaries & MCB in base compartment are not included and are a part of installation) complete all as specified and directed by the Engr-in-Charge. 36 Supply of fix single dome LED type dome aviation obstruction light complete all specified and directed by Engr-in-Charge. Make : Bajaj Cat No : BGAV302LED or its equivalent in make specified in PS. 37 Supply and fix foundation bolts 04 Nos 24mm dia 850mm length, manufactured from special steel along with nuts, washers, anchor plate and common template complete all as specified and as directed. 38 Supply and fix LED flood light 250 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all specified and directed by Engr-in-Charge. 39 DG SETSupply installation testing and commissioning of Silent type Diesel Engine Generating set 415 volts 320 KVA, 3 phase 0.8 power factor, 50 Hz,developing 434 BHP @ 1500 RPM ,self exicited , self regulated brushless AC generator including AMF panel, suitable for ambient condition at Yelahanka and confirming to condition under CPCB 4+, ISO 8528-1, 3046, IS 10002, BS 5514/5000 with capacity of 10% overloading for one hour in every twelve hour duration andincluding the following accessories :-Make : Kirloskar / Ashok Leyland/ Ruston/Cummins 40 (A) Alternator :-Synchronous alternator rated at 320 KVA suitable for continuous operation at 1500 RPM generating 415 volts at 0.8 p. f (lag) suitable for 50 Hz, three phase, 4 wire system. The alternator shall be brushless,single bearing,self excited & self regulated with an AVR .The alternator will be suitable for tropical climate and shall generally confirm to IS: 4722 : 2001 The salient features of the alternators are :-(a)+-1% voltage regulation (max) in static conditions.(b)IP: 23 protections with class ‘H’ insulation. · (c)Permanent lubricating bearing. · (d)Permissible overload of 10% for one hour in 12 hours of operation.(B) Diesel Engine: - Adquate capacity of Diesel engineliquid cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection,cold starting 1500 RPM, as per relevant IS/BS complete with standard accessories all as specified and required for safe handling and operation. Salient features of accessories shall be as under :- i) Fly wheel with housingii) Cooling system :- Moulded radiator with fan & belts.iii) Cooling Liquid pump : - Centrifugal type belt driven.iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe medium grade, Silencer : Residential typev) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electric operated/ (as recommended by OEM) for 1% speed /frequecy regulation.,Fuel filters, Fuel hosesvi) Lub oil System :- Lubricating oil filter,Lubricating oil pumpvii) Air Intake System :- Air intake Manifold,Air cleaner dry typeviii) Governer : Electronic typeix) Starting System :- Electric Self starter , including battery charging alternator 12 Volts DC.x) Batteries :- Batteries maintenance free of capacity 12 V, 150 AH- 02 No complete with copper conductor multistranded leads of suitable length fromself starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified. 41 xi) Generator Monitoring Panel : - Comprising of all standard items as per standard manufacturing, iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, coolant temperature indicator, Battery volt display.xii) Safety Controls : - Engine low lube oil pressure,high coolant temperature and over speeding of engine.xiii) Coupling arrngement : - Flexible couplingxiv) Accessories :- AVM Pads built- in or separtely mounted to manufactrer base frames.xv) Base Frame : - Base frame is fabricated either in ISMCor in sheet metal.The base frame is rugged in construction and designed for mounting Diesel engine and alternator close coupled, with cross members mounted on AVM. The base frame shall have provision for mounting of acoustic enclosure & control panel on it and lifting hook for complete seti.e. along with canopy, engine and alternator.xvi) MS/Steel flexible pipe line to and from the fuel tank to the DG Set.xvii) Battery Charger shall be provided as per manufacturer guidelines.xviii) 2 No battery of 12 V in charged condition with its leads. C)ACOUSTIC ENCLOSURE : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Powder coating is done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam as acoustic material & Rock wool for hot zone.Adequate hinged doors shall be provided to canopy, one door shall have glass window for control panel visibility. 42 (i)Manufactured by OEM suitable for 320 KVA DG Set.(ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.(iii) The generating setbattery should be inside the enclosure.(iv) Fuel tank :-Daily service fuel tank of 8 hours of continuous operation, fabricated form 14/16 SWG sheet metal complete with drain, inlet and outlet connection and fuel gauge.(v) Construction Details/specification are as follows : - (a) Outer body :- CRCA Sheet of 1.6mm thick. (b) Doors :- CRCA sheet of 1.6 mm thick. (c) Sound Insulation :- 100 mm thick rock wool(minimum density 64kg/Cum)/ fire resistancefoam/puff as per OEM/ as per standard manufacturing to achieve desired decibel level.vi) The acoustic should be composite in construction and fully assembled integral unit.vii) The DG Set should be provided with external Emergency stop push button.viii) The enclosure should be suitably internally illuminated by LED Lamp fittings.ix) The noise level should be < 75 dB at 1m under free field conditions.x) The acoustic enclosure parts shall be of powder coated after pre treatment process.The base frame should be painted with epoxy based black shade.D) Control Panel :- Control panel shall befabricated from 16/14 SWG sheet and powder coated after seven tank treatment process:(i) Microprocessor based generator set monitoring and control system consists of LCD display and to monitor operator interface, fault history, alternator data, Engine data, porvision for service adjustement and caliberation of DG control functions, Engine controls, engine protective functions, alternator protective functions etc.(ii) Instrument fuses and control wiring. (iii) Indication lampsset for running and load on.(iv) Bus bar including suitable capacity of MCCB, including CTs, cable etc. 43 E) AMF Panel :- Automatic Mains Failure (AMF) Panel should be outdoor made of CRCA sheet 3.15 mm thick including necessary arrangement to Install, Testing and Commissioning complete all as per OEM recommendation. F) Civil Works :-All civil works including PCC (1:3:6) platform with a height of 60 cm above ground level and upto a width of 60 cm both sides of DG Set for easy operation of operator and necessary maint workand related foundationsfor panel and equipments including making good of distrubed area during installation and commissioning of genset . The depth and size of the foundation and PCC as recommended by the manufacturer.The contractor shall arrangeartificial load resistive for testing of DG Set at site and the cost is deemed to be included in the quoted rates.Note :- (i) The complete DG Set shall be procured from authorised OEM of the manufacturer of engine. A certificate in this connection shall be submitted to the GE.(ii) Circulation system toachieve desired inside temperature of acoustic enclosure, if required shall be provided as per OEM recommendation.(iii) The quoted rate shall be deemed to be inclusive of 12 hours test run at site as specified in PS and IS requirements in presence E/M Offr detailed by accepting officer, all testing arrangements/ equipments shall be made available by the contractor for tests.(iv) The quoted rate shall be deemed to be inclusive of first fill of lubricant oil, DHPP for 12 hours testing and final successful acceptance test.(v) Anything missed out above but technically required for efficient working of DG Set is deemed to be included in quoted rates.vi) Design / drawing of the AMF panel & DG SET showing the dimensions is to be obtained from DG SET/ panel board manufacturer / supplier & is to be got approved fromEngr-in-charge/GE before placing final order to the manufacturer.vii) The electrical connection of digital Multi Functional Meter in the AMF panel is to be done from load side so that monitoring of various parameters viz. Voltage, Current, KW, KVA, power factor, frequency etc can be done of both SEB mains & DG mains.viii)The quoted rate shall be deemed to be inclusive of first fill of engine oil & final successful acceptance test.ix) The quoted rate shall be deemed to be inclclusive one set of all types of filters , complete set of Maint tools & fuel refilling pump for filling fuel to DG set. 44 Earthing complete with galvanized steel earthplate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in a pit (earth pit of depth not less than 2.25 metre below ground level) with top edge of the earth platenot less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt 15cm thick each layer and electrode connected to and includinggalvanized iron earth strip, 32 x 6 mm (earth lead) by means of bolts, nuts, check nuts and washers of galvanisedsteel protection pipe light grade 40mm dia and GI pipelight grade 20mm dia bore for watering, funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sq m) and frame including all excavation and earth work all as shown in electrical plate No 3 connected to earthing test point complete all as specified and as directed including testing on completion.Note : The unit rate includes for 40mm light grade protecton pipe and GI earth strip 32 x 6mm from top of earth plate upto 7.50 metre above ground level.The earth pit shall be constructed atleast 1.5m away from the top of earth electrode. 45 REFRIGERATION & AIR CONDITIONING:-Supply, install, testing and commissioning hi wall inverter split units indoor/outdoor with invertercompressor with adjust power depending on load complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with minimum 5 star ratingAs perBEE guidelines and ISEERValue not less than 3.90 for air conditionerof capacity 1.5 TR includingall specified and directed by Engr-in-Charge. 46 Supply, install, testing and commissioning hi wall inverter split units indoor/outdoor with invertercompressor with adjust power depending on load complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with minimum 5 star rating as perBEE guidelines and ISEERValue 3.95 for air conditionerof capacity 2 TR complete all specified and directed by Engr-in-Charge 47 Supply, fixing, jointing and testing copper tubing with nominal diameter1-1/4 inch ofthickness not less than 1.2mmfor liquid line to connect with out door unit complete all as specified and directed by Engr-in-Charge. 48 Supply, fixing jointing and testing copper tubing with nominal dia meter3/8 inch of minimum thickness not less 0.9mm including expanded polythene foam insulation for external insulation of suction line for connecting with outdoor condensing unitcomplete all as specified and directed by Engr-in-Charge. 49 Material and Labour for fabrication of base stand made from MS angle iron of size 50mmx50mm, 6mm thick including necessary nuts, bolts & washers for mounting of outdoor unit of 1.5/2 TR capacity Split AC including painting with two coats of metal paint over one coat synthetic enameled black paint complete all as specified and directed by Engr-in-Charge. 50 Supply and fix PVC non-metallic flexible pipe of size 20mm dia alongwith fixing accessories such as saddles, pipe hook etc, for draining out the water from indoor unit complete all as specified and as directed by Engr-in-Charge. 51 HAND DRIER AND SOAP DISPENSERSupply and fix automatic hand drier machine suitable for single phase supply 230 Volts, 50 Hzwith ABS plastic body complete all as specified and directed. 52 Supply and fix automatic soap dispenser , 220 V , 50 Hz complete all as specified and directed. 53 UPSSupply, installation, testing and commissioning of online UPS of 30 KVA with isolation transformer and static bypass switch, Authomatic transfer switch of capacity 100 Amps 4 Pole) alongwith required sealed maintenance free batteries and batteries (12V 100 AH-32 Nos)with stand for backup of 30 min totally enclosed, free standing type, dust, damp and vermin proof, interconnections, wiring from normal sources upto UPS complete as required.I/P Voltage 360 V - 480 VNominal frequency - 50 HzFrequency range for online operation 45-50 HzI/P current range - 36A - 29AO/P voltage 415 VO/P current - 42A 54 LIGHTNING PROTECTIONSupply & fix Special standing seam fixure Clamp for Air terminal on Metal Structure -Site specific all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JICT54 or its equivalent in approved make. 55 Supply & fix Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol, 3 mtr mast all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JIAT02JIM04 or its equivalent in approved make. 56 Supply & fix 8 mm dia solid Aluminium Conductor for Down Conductor and tested as per IEC 62561- 2 conducted in the Govt. aggregated thirty party laboratory to meet the requirement of IS/ IEC 62305 all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JIDC01 or its equivalent in approved make. 57 Supply & fix Aluminium conductor holding clamp suitable for fixing 8 mm Down Conductor, Conductor holder @ 1 meter distance should be tested as per IEC-62561-2 conditioning & Ageing test, conducted in the Govt. accredited thirty party laboratory to meet the requirement of IS/ IEC 62305 all as specified and directed by Engr-in-Charge. Make JEF Cat No JIDC01 or approved by E-in-C Branch/CE Southern Command.Make : TIRUMALA/JEF Cat No JICL07 or its equivalent in approved make. 58 Supply & fix Standing Seam clamp to hold 8 mm Al conductor at every 1m dist on the top roof without any drilling on roof, Installation can be made through simple fastening system ,mainly used for seaming sheet roof application tested as per IEC-62561-2 for conditioning & Ageing test & conducted in the Govt. accredited Third party laboratory to meet the requirements of IS/IEC 62305 all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JICL49 or its equivalent in approved make. 59 Supply & fix Cross splicer should be ttested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEFCat No JISP02 or its equivalent in approved make. 60 Supply & fix Aluminium Straight Splicers for 8mm and 10 mm Conductor to meet the requirement of IS IEC 62305 tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No JISP01 or its equivalent in approved make. 61 Supply & fix Expansion Piece without connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations to be provided on conductors length over 20 meters to connect Solid Round Al. Conductor at both ends to meet the requirements of IS/IEC 62305 all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEFCat No JISP05 or its equivalent in approved make. 62 Supply & fix test link in order to disconnect the earth termination system for enabling measurements. SS Test Link To connectRound to Flatconductor all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No TL06 or its equivalent in approved make. 63 Supply & fix Earth Electrode Cu Bonded Steel Rod 14.2mm dia x 3000mm-(250Microns);Eco Friendly rust proof heavy duty weather proof Polyethylene Earth Pit Chamber with following dimensions :254 mm dia (top), 330 mm dia (bottom) & 260 mm (height).;14.2 / OD SS Clamp Both Side; Carbon based backfill compound - 25Kg all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEF Cat No R14.CB1.SS01.E06 or its equivalent in approved make. 64 Suply & fix25 X 6 mm size GI strip from AL Conductor to the earth pit station and further the same strip shall be used for interconnecting all the earth pits below ground leve Zinc coating: 500 g/m square (Approx :70 micron coating) Should be tested and use exclusively for lightning protection ,earthing system and ring equipotential bonding all as specified and directed by Engr-in-ChargeMake : TIRUMALA/JEF Cat No DW16 or its equivalent in approved make. 65 Supply & fix Holder -GI for fixing 25x 6 mm GI Strip complete all as specified and directed by Engr-in-Charge. Make : TIRUMALA/JEFNo JICL08 or its equivalent in approved make. 66 MEDICAL GAS PIPE LINE SYSTEMSupply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :12mm X 0.7 mm laser Printing on every pipe. Make : Max / Flow/Raj/ janya/ RAJ 67 Supply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :15mm X 0.9 mm laser Printing on every pipe. Make : Max / Flow/Raj/ janya/ RAJ 68 Supply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :22x0.9mmlaser Printing on every pipe ) Make : Max / Flow/Raj/ janya/ RAJ 69 Supply and installation / fixing, testing and commissioning of Copper pipe : Degreased seamless round coppertube confirming to EN13348:2008 with colour coding for :28 x0.9mmlaser Printing on every pipe ) Make : Max / Flow/Raj/ janya/ RAJ 70 Supply and fix BS Standard type GEM 10 gasoutlet withprobefor oxygen complete all as specified and as directed. 71 Supply and fix Humidfier bottle forBPC flow meter complete all as specified and as directed. 72 Supply and fix Metal body BPC flow meter (0-15 ltrs ) adult complete all as specified and as directed. 73 Supply and fix BS Standard type GEM 10 gasoutlet withprobefor vacume complete all as specified and as directed. 74 Supply and fix 600 ML VACUUMEJar complete all as specified and as directed. 75 Supply and fix Vacummer regulator complete all as specified and as directed. 76 Supply and fix Zonal valve box completeset withisolationballvalve and gauge (Aluminium framewith MSBox for2services (15mmx 22mm) complete all as specified and as directed. 77 Supply and fix Microprocessor based line pressurealarmdigitaltypefor2 gas serivce(oxygen / vacumm) complete all as specified and as directed. 78 Material and labour for perforated powder coated cable tray of size 25x100x25 mm, thickness 2mm for holding of oxygen gas pipe line all as specified and directed. Make: Daspar / Super Steel Industry / SV metals Pvt Ltd 79 DEMOLITION OF EXISTING BUILDINS (E/M ITEMS)Taking down unserviceble submain wiring any size /any cap complete all as specified and as directed. 80 Taking down unserviceble DBs any size / any cap complete all as specified and as directed. 81 Taking down unservicebleMCB SP/SPN any size /any cap complete all as specified and as directed. 82 Taking up old earthing any size/any type complete all as specified and as directed. 83 Takingdown earth strip/wire any size/any type complete all as specified and as directed. 84 Dismantling and taking out carefully GI pipe 25mmdia including earth work/RCC and complete all as specified and directed Engr -in-Charge.