Tender For Provision Of Certain Minor And Revenue Works Under Ge Gurdaspur.; 1 M&L for point wiring PVC insulated PVC sheathed FRLSH multisreanded copper conductor cable of size 2.5 sqmm including concealed PVC conduit fitting and making good to the disturbed surfaces continous PVC insulated PVC sheathed FRLSH multisreanded earth wire of copper 2.5 Sqmm dia to common earth including provn of 3 mm thick hylem sheet of appropriate size and fixing to existing CI/MS boxes for mounting of accessories like surfaces sockets and regulators complete all as specified. 2 S&F switch piano flush type single pole 1 way 15 amp complete all as specified and directed by Engineer-in-Charge. 3 S&F Socket outlet 3 pin 15 amp flush type complete all as specified and directed by Engineer-in-Charge. 4 S&F GI pipe 15mm dia medium grade with all fittings and fixed complete to wall and ceiling or Laid in trenches including drill hole on wall for in coming and out going pipe and make good of disturbed surface including plaster and painting complete all as specified and directed by Engineer-in-Charge. 5 S&F GI pipe 20mm dia medium grade with all fittings and fixed complete to wall and ceiling or laid in trenches including drill hole on wall for in coming and out going pipe complete all as specified and directed by Engineer-in-Charge. 6 S&F bib taps cast copper alloy with crutch or butterfly handle screwed for iron pipe 15mm dia chromium plated fency type complete all as specified and directed by Engineer-in-Charge. 7 S&F stop valve cost copper alloy 15 mm dia screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge. 8 S&F electric water heater, storage type steel body with copper inner tank and heating element 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safty valve, thermostate, NRV, connection piece etc complete all as specified and directed. 9 Supply and grouting 4 Nos nut & bolts 90 mm long 12mm dia on wall for fixing one geyser and fixing with clamp complete all as specified and directed by Engineer-in-Charge. 10 S&F PVC connection 15mm diameter PTMT nut bolt of length 300 mm complete all as specified and directed by Engineer-in-Charge. 11 S&F in replacement of aluminium strip 25 x 3.15 mm with saddles and fixing screws, insulators rawal plugs etc forconductor for roof and fixed on wall upto test point complete all as specified and directed. 12 S&F replacement of galvanized iron strip 32 x 6mm fixed with saddles & fixing screws, PVC dash fastners, insulators fixed from test point to earth on walls or burried in ground / drawn into hume pipe complete all as specified and directed. 13 S&F replacement of single pointed air termination aluminium rod 12mm dia, 300 mm long complete all as specified and directed. 14 S&F test point terminal block made of gun metal or phosphorous bronge 75 x 75 x 25mm of 6mm thickness drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to wall for protection of test point completed all as specified. 15 M&L for earthing complete with galvanised steel earth plate electrode 60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. 16 M&L for aluminum scaffolding staircase of size 1.35m x 1.8 m and platform height 13.50m, tower height 14.50m, working height 15.50m including connected accessories like base plate, diagnonal brage, entry frame, guard rail, handrail, horizontal brace, stairway, top handrail, triangular stabliser, wooden hinge platform, wooden plain platform, used for changing lights of ceiling of cinema hall and dimensions as per site requirement complete all as specified and directed. (Note :- The contractors are required to read throughly before quotaing and site must be visited for fabrication of staircase for quoting the rates. The nature of work must be crystal clear before quoting complete specification and dimention will be as per use of staircase at cinema hall and will be finalised as specified and directed by Engineer-in-Charge.Final design of staircase will be approved by Engineer-in-Charge before fabrication). 17 Supply & installing water cooler electric driven (single phase) fully stainless steel storage capacityhaving approx 80 ltr and nominal cooling capacity 40 ltr per hour including plateform & suitable drainage arrangementfor waste water complete all as specified and directed. 18 Supply, installation and fix refrigerator 310 ltr net capacity, electric driven, single phase, frost free, stabilizer free operation, with automatic digital inverter technology easy clean back feature with safty cover at back for safty of internal vital components such as condenser coil, capillary tube, compressor etc with environment friendly R134a/ R600A refrigerant. The refrigerator should have two separate shelves each for freezer and general cooling area (double door) complete with all standard accessories as per manufacturers instruction. 19 S&F MCB protected industrial type plug and socket with 25 amp, 240 volts MCB made out of sheet steel encloser flush type complete all as specified and directed. 20 S&F voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volt to 250 Volt with output stablized at 230 Volt with accuracy of +2.5 % to -2.5 % and capacity 4.0 KVA complete all as specified and directed. 21 S&F air cooled split unit air conditioner of 1.5 TR , BEE 5 Star rated complete all as specified and directed 22 M&L for sub main wiring with twosingle core PVC insulated, unsheathed, stranded copper conductor cable, FRLSH of size 4 sqmm and one PVC insulated, unsheathed, copper conductor cable, FRLSH of size 2.5 sqmm as earth wirefixed in and including concealed non matalic PVC conduit of appropriate dia complete all as specified. (Note :- Three run of cable along with PVC conduit together shall be measured as single run) 23 S&F off grid solar tree system of 1.5 KW (20 x solar panel each 75 WP) with multiple branches holding solar panel with 20 Nos of LED of 5W each and weather resistant structure made from galvanized steel, mild steel or stainless steel ( pipe dia min 2.5 inch of length 6 mtr).The solar tree must have min 20 No of leafs with 75 degree of angle of elevated PV modules.Battery life PO4 of input phase 12.08 Volt of 1420 AH, module efficiency upto 17% output phase more than 305 rated power 7-8 KWH, solar tree pole LED white, multi colours with batter bank syhstem for whole night and using cable of 1.5 sqmm, 2 core for connection also and having 02 Nos of mobile charging point and 01 No of Laptop charging point complete all as specified and directed by Engineer-in-Charge.Note :- Foundation for mounting of Solar tree shall be carried out as per manufacturer design within overall cost quoted). 24 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth in soft/loose soil and getting out all as directed. 25 M&L for hardcore of broken stone or boulders of guage n. exc 63mm deposited, spread and levelled in layers .n exc. 15 cm thick, watered and rammed toa true surface complete all as specified and directed. 26 M&L for PCC 1:5:10 type E-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. 27 M&L for machine pressed precast concrete interlocking paver blockany shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 grade with gray cement, no pigment and joints filled with sand complete all as specified and directed. 28 M&L for 25mm sand filling under floors or in foundations including watering and consolidation all as specified and directed. 29 M&L for rolled mild steel Gde Fe-410-W, Gde-E-250 quality A for roof trusses (framed), trussed, purlins, crane gantries, rails joist , channel, steel tube, rails, fastenings and heavy bracket framing (Beam, tee, angle, column, gusset plates, channel, hollow square/ rectangular or flat sections) including distance pieces, cleats with riveted bolted or welded attachment etc complete all as specified and directed by Engineer-in-Charge. 30 M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint overone coat of red oxide primer complete all as specified and directed. 31 S&F pre-painted gavalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPaas in roof covering/cladding to walls, fixed with self tapping screws complete all as specified and directed. 32 M&L for brick work with fly ash old size bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed. 33 M&L for 15mm thick rendering with ready mix cement mortar on fair faces of brick work and finishing surface even and fair complete all as specified and directed. 34 M&L for preperation of new plastered surface and applying two coats of cement base paintover a coat of primer complete all as specified and directed. 35 Excavation in post holes (or similar holes) in soft/ loose soil each not exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth arround in layers not exc 25cm thick all as specified and directed. 36 M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete etc complete all as specified and directed. 37 Returning, filling in soft/loose soilincluding spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified & directed. 38 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.