Term Contract For The Rehabilitation, Maintenance And Construction Of Cable Duct System For One Year (2025-26) In Vileparle. Vakola, Andheri, Jogeshwari, Versova, Te Area (2Nd Call); 1.1.18 Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. cum 494.10 Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. 494.10 One cum2.8 Earth work in excavation by mechanical means (Hydraulicexcavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal ofsurplus excavated soil asdirected, within a lead of 50 m. 2.8.1 All Kinds of Soil 260.30 onecum2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 196.00 onecum4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All workup to plinth level: 4.1.5 1:3:6 (1 Cement: 3 coarse sand (Zone-I) derived from natural sources: 6 graded stone aggregate 20 mm nominalsize derived from natural sources) 7294.70 onecum4.1.10 1:5:10 (1 cement: 5 coarse sand (Zone-I) derived from natural sources: 10 graded stone aggregate 40 mm nominal size derived from natural sources) 6518.60 onecum4.7 Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement: 3 coarse sand), cost of required centering, shuttering complete: 4.7.1 1:1½:3 (1 Cement: 1½ coarse sand(Zone-I) derived fromnatural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). 17889.25 onecum5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 5.1.2 1:1.5:3 (1 cement: 1.5 coarse sand (Zone-I) derived from natural sources: 3 graded stone aggregate 20 mm nominal size de rived from natural sources) 9045.75 onecum 5.1.3 1:2:4 (1 cement: 2 coarse sand (Zone-I) derived from naturalsources: 4 graded stone aggregate 20 mm nominal size de rived from natural sources) 8583.40 onecum5.9 Centering and shuttering including strutting, propping etc.and removal of form work for: 5.9.1 Foundations, footings, bases of columns, etc. for massconcrete 392.15 onesqm5.9.2 Walls (any thickness) including attached pilasters,buttresses, plinth and string courses etc. 842.50 onesqm5.9.3 Suspended floors, roofs, landings, balconies andaccess platform 927.25 onesqm5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all completeupto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500Dormore. 107.85 onekg 10.1 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 117.35 onekg 10.25 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.1 In stringers, treads, landings etc. of staircases, including use of chequered plate wherever required, allcomplete 123.60 onekg 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works 172.60 onekg 13.1 12m thick cement plaster 13.1.2 1:6 (1 cement: 6 fine sand) 333.35 one sqm13.16 6mm thick cement plaster of mix: 13.16.1 1:3 (1 cement :3 fine sand) 300.45 one sqm13.18 Neat cement punning 79.95 one sqm15.2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres leadas per direction of Engineer - in - charge. 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 2434.25 one cum15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalentdesign mix) 1503.60 one cum15.3 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceablematerial within 50 meter lead as per direction of Engineer - in- charge. 3551.25 one cum15.43 Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meter lead as per direction of Engineer- in-charge: 15.43.2 Bituminous Road 428.50 one sqm TCD-01 Providing & laying 2.5 mm thick 110mm dia (O/D) PVC pipes with 4mm thick PP rope of approved quality & make with ABSthermoplastic spacers of approved quality & make @ 2m c/c spacing wherever required including the cost of PVC cap wherever required etc. complete as directed by Engineer in Charge. 297.00 onemetreTCD-02 Modifying the existing MH/PC/HH which shall include 1) Excavation & proper barricading of work site by taking all precautionary measures such as caution boards, steel barricades, red flags, red lamps etc. asrequired. 2) Cleaning surfaces 3) Road cutting, removing of frames, covers, I - beam etc.& keeping them in safe place with watch & ward. 4) Dismantling existing RCC & PCC, 5) Cutting & straightening the existing reinforcement ifrequired any. 6) Placing, bending & binding the additional reinforcement. 7) Applying neat cement slurry for bondage with oldconcrete, 8) Shuttering ¢ering, 9) Providing/laying RCC1:1.5:3 (1-cement 1.5-coarsesand 3- graded stone aggregate 20mm nominal size) 10) PCC 1:5:10 (1 cement:5 coarse sand:10 graded stone aggregate 20mm nominal size), 11) Plastering on new surface in cement mortar 1:3 (1cement: 3 fine sands) & repairing at broken places. 12) Back filling, 13) Removal of barricading, 14) Refixing old frame, cover & I beam, 15) Fixing new frame, cover & I beam, if necessary, 16) Other item, if necessary, as directed by Engineer- in-charge. 17) Necessary curing, 18) Cleaning the site. The completed job shown against Sl. No. 4, 6,16& 19 shall be paid as under, & other job shall be paid based on quantityunder the relevant items; in Section A. 4715.00 EachTCD-03 Raising/lowering the necks of MH/PC/HH to match with theroad level, the works includes as follows: 1) Proper barricading of work site by taking all precautionary measures such as caution boards, steelbarricades, red flags red lamps etc. 2) Necessary excavation, 3) Road cutting, 4) Removing of frames, covers, beam etc.& keepingthem in safety place with watch & ward, 5) Apply neat cement slurry for bondage with oldconcrete. 6) Providing additionalsteelreinforcement ifrequired, 7) Repairing of broken plaster on old as well as new surface in cement mortar 1:3 (1 cement :3 fine sand) 8) Necessary curing, 9) Back filling, 10) Cleaning of site. 11) Removal of barricading. Complete as directed by Engineer-in-Charge (the completedjob shall be paid under this except PCC, RCC, reinforcement,cement plaster &new covers & frames which shall be paid under relevant order) TCD-03-1 Raising/lowering the neck which includes Barricading removing of frame & cover of MHs, refixing the same, etc. 2477.00 EachTCD-03-2 Raising/lowering the neck which includes Barricading removing of frame/ covers/ I-beam of PCs etc. & re- fixing thesame TCD-03-2-1 PC of size 1.8m X 1.8m X 1m or equivalent volume. 2991.00 EachTCD-03-2-2 PC of size 3m X 1.8m X 1.8m or equivalent volume. 5656.00 EachTCD-03-2-3 PC of size 4m X 1.8m X 1.8m or equivalent volume. 7133.00 EachTCD-03-3 Raising/lowering which includes barricading removal offrames covers/ I beams of HHs & re-fixing the same. TCD-03-3-1 H/H type I of size 1.2m X 0.7m x1.0m or equivalentvolume. 1808.00 EachTCD-03-3-2 H/H type II of size 1.8m X 0.8m x1.0m or equivalentvolume. 2211.00 EachTCD-03-3-3 H/H of volume more than 1.44 cum or equivalent volume. 2371.00 EachTCD-04 Providing & fixing 110mm dia. (O/D) PVC poke out pipe in MH,PC & HH towards foot path necessary excavation, holes in RCCwalls, for the pipes & making good the same with cement concrete of 1:1.5:3(1 cement:1.5coarse sand:3 graded stone aggregate 10mm nominal size) mixed with water proofing compound, flushing the pipe with internal surface, repairing the broken plaster(inside location) with 6mm plaster in cement mortar 1:3(1 cement: 3 fine sand ) encasing the pipes in cement concrete of 1:3:6(1 cement:3coarse sand:6 graded stone aggregate 20mm nominal size) fixing PVC cap to outer end of duct pipe, backfilling disposal of surplus earth/material as per local bye laws, required dewatering etc. complete as directed by Engineer- in - Charge.(The completed item shall be paid under this item except PVC pipes which shall be paid under relevant item) 782.00 EachholeTCD-05 Providing and fixing in position cast iron covers, frames, cable bearers, neck grills, sump grills of approved make quality, size& weight in MH, PC & HH in place of defective, broken or missing one, making good wherever required with matching RCC, PCC cement plaster & stacking the serviceable materials as directed etc. completed as directed by Engineer-In-Charge (The complete item shall be paid under this item except RCC, PCC, plaster which shall be paid under relevantitems. TCD-05-1 a) C.I. covers, grills and frames, fixing with materials forMH/HH. 113.00 onekg TCD-05-2 b) Labour charges for fixing of C.I. covers, grills, & framesincluding transportation (for the material supplied by deptt) 7.00 onekg TCD-06 Providing & fixing in position SFRC covers of approved quality, size & make in MH, PC & HH in place of defective broken or missing covers complete as directed by Engineer- in-Charge. TCD-06-1 S.F.R.C. covers size 780mm dia.& 94mm thickness 5646.00 EachTCD-06-2 S.F.R.C. covers size 780mm dia.& 94mm thickness without fiber 3299.00 EachTCD-06-3 S.F.R.C. covers size 825 X 625 X 94mm 5725.00 EachTCD-06-4 S.F.R.C. covers size 825 X 625 X 94mm without fiber 3334.00 Each TCD-06-5 S.F.R.C. covers size 925 X 625X 94mm 6079.00 EachTCD-06-6 S.F.R.C. covers size 925 X 625X 94mm without fiber 3505.00 EachTCD-06-7 S.F.R.C. covers size 925 X 775 X 94mm 6905.00 EachTCD-06-8 S.F.R.C. covers size 925 X 775 X 94mm without fiber 3904.00 EachTCD-07 Cleaning of existing PVC/GI/UPVC duct pipes; removal of obstruction if any, caused by deposition of rubbish, silt, filth or similar material, by watering jet &brushing etc. failing which by digging the location of the obstruction, breaking the duct matching the pipes; providing & laying 4mm dia PP rope; passing 92mm dia mandrel/cable piece of required length: etc. complete as directed by Engineer in Charge. (The complete item shall be paid as under only except cutting road/footpath, excavation, dismantling concrete, new PVC pipes, PCC under relevant items). TCD-07-1 Cleaning of PVC/GI/UPVC pipes & passing mandrel or pieceof cable of 92mm dia.& 1m length. (110mm dia. O/D) 10.00 one metreTCD-07-2 Providing & inserting Poly propylene rope 4mm dia, in existing pipes all complete as directed by Engineer-in–Charge 10.00 one metreTCD-08 Providing & fixing 300 mm long threaded entry pipes assembly TEPA to the110 mm entry duct pipes in MHs/PCs/HHs etc. complete as directed by Engineer in Charge. (Cost includes dismantling of existing concrete & making good after complete work) 833.00 EachTCD-09 Providing & fixing double Gasket PVC expansion plugs to 110mm duct pipes. 237.00 EachTCD-10 Credit for taking over recovered damaged unserviceable material TCD-10-1 C.I. Items 35.00 onekg TCD-10-2 G.I./MS items 35.00 onekg TCD-10-3 Mild/Torsteel 35.00 onekg TCD-10-4 SFRC coves of MH/HH 200.00 EachTCD-10-5 Unserviceable PVC pipe-110 mm (1 kg/metre) 25.00 one Kg TCD-11 Providing & laying SUB-DUCTING in 110mm/150mm O/D PVCpipes with 40 mm outer dia & 3mm wall thickness HDPE pipe (Conforming to IS 4984-1985) one pipe & inserting 4mm dia pp rope in sub-duct pipes (cost includes for all materials & labour required for subducting items with insertion of pp rope, inside subduct. & Dewatering.) TCD-11-1 40 mm dia. one No. HDPE pipes. 70.00 one metreTCD-11-2 40 mm dia. Two Nos. HDPE pipes. 137.00 one metreTCD-11-3 40 mm dia. Three Nos. HDPE pipes. 204.00 one metreTCD-12 Providing & laying SUB/Inner duct in 110/150mm O/D PVC pipes with MaxCell EM 5621-3 or equivalent, suitable for laying three cables of size upto 21 mm manufactured from Polyster and Nylon .Each cell shall be of 30mm dia consisting a pull tap of 12 mm with rope. 237..00 one metre TCD-13 Providing & laying HDPE pipe of 110 mm O/D class III, thickness not less than 5.0 mm as per IS :4984, with 4mm thick PP rope approved quality & other fittings wherever required etc all complete as per direction of Engineer-in– charge. 344.00 one metreTCD-14 Providing & laying HDPE pipe of 125 mm O/D class III, thickness not less than 5.0 mm as per IS :4984 (Black/ Orange colour only), with 4mm thick PP rope approved quality & other fittings wherever required etc. all completes as per direction of Engineer- in-charge 455.00 one metreTCD-15 Providing &applying watertightsealing (3M type/DUX- 100 orequivalent) of the duct pipes containing cables in MH/PC complete as per the manufacturers specifications & the direction of Engineer-in- Charge. The empty kit shall be returned to the department after use for release of payment. 746.00 EachTCD-16 P/F G.I. Pipes complete with G.I. Fitting including requiredtrenching & refilling etc. external work (B class) TCD-16-1 100mm nominal bore 2006.00 one metreTCD-16-2 125mm nominal bore 2537.00 one metreTCD-17 Providing ABS thermoplastic spacers of approved make for PVC pipe duct at required spacing as directed by Engineer- in-charge. TCD-17-1 One side spacers of required size & shape TCD-17-1-1 (i) 2-way spacer 81.00 EachTCD-17-1-2 (ii) 4-way spacer 158.00 EachTCD-17-2 Both side spacers of required size & shape TCD-17-2-1 (i) 2-way spacer 95.00 EachTCD-17-2-2 (ii) 4-way spacer 187.00 EachTCD-18 Providing & laying 40/33 PLB HDPE pipe for laying in trenches or 110mm/150mm O/D PVC pipes with 40 mm outer dia PLB pipe one no & inserting 4mm dia pp rope (cost includes for all materials & labour required for PLB HDPE pipe with insertionof pp rope inside PLB pipe & dewatering wherever required.) TCD-18-1 40/33 mm dia. PLB HDPE pipe one no. 81.00 one metreTCD-18-2 40/33 mm dia. PLB HDPE pipe Two nos. 148.00 one metreTCD-18-3 40/33 mm dia. PLB HDPE pipe Three nos. 223.00 one metre