Tender For Special Repair To Bldg No P-27 Of Mh Ambala Under Ge (South) Ambala Cantt.; 1 Dismantling of brick or terracing tiles of single layers on roofs including cleaning of bricks/tiles and removal of unusable bricks/tiles and removal from site, complete all as specified and directed by Engineer-in-Charge. 2 Demolition of Mud in roofs, any thickness, including plastering and leeping complete all as specified and as directed. 3 Material and labour for Plain Cement concrete1:2:4 type B-1(using 20mm mechanically graded crushed stone aggregate) as in padding to roof to maintain the required slope and finished the surface even and smooth without using extra cementincluding weathering, slightly rounded or chamfered angles and throating with and including using necessary formwork for fair finished surface complete all as specified and directed by Engineer-in-Charge. 4 Material and labour for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application, including tack coat of 85/25 of industrial bitumen completed all as specified and directed by Engineer-in-Charge. 5 Material and labour plain cement concrete 1:2:4 type B1 (using 20 mm graded aggregate) in roof kerbs of mud stops, rounded or chamfered on edges complete all as specified and directed. 6 Material and labour for 10mm thick plastering in CM 1:3 on concrete roof surfaces with water proofing compound @ 3% by weight of cement and finishing the surface even and fair without using extra cement all as specified and directed.Note :- WPC shall be measured and paid separately. 7 Material and labour for Precast plain cement concrete plain factory made tiles, 22 mm thick of size 250 mm x 250 mm, machine pressed and cut polished and set jointed and pointed in neat cement slurry andfabricated using grey cement & no pigments. over and including 15 mm thick cement mortar (1:3) beddingjoints grouted flush in cement mortar (1:3) mixed with integral liquid water proofing compound over roof surfaces complete all as specified and directed by Engineer-in-Charge. 8 Taking down cement plaster from brickorconcrete surfaces including raking out joints, hacking keys, scrubbing down with water etc. complete all as specified and as directed. 9 Material and labour for rough cast plastering including 15 mm thick rendering in Cement mortar 1:3 complete as specified in SSR Part I, clause 14.22.(Note : Rough cast finish to be as below :-After applying the under coat of cement mortar 1:3 and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel aggregate (which is generally of size between 6 to 12 mm depending on the texture required) mixed with coarse sand and cement in the ratio of 1: 1: 1 shall be applied and finished even.The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger aggregates are thoroughly covered.( Upto height 15 mtrs), complete all as specified and directed by Engineer-in-Charge. 10 Material and labour for rendering 10mm thick on fair face of brick work , concrete surfaces in cement mortar 1:6 finished even and smooth without extra cement all as specified and as directed. 11 Material and labour for rendering 15 mm thick on fair face of brick work , concrete surfaces in cement mortar 1:4 finished even and fair without extra cement mixed with WPC @ 2% by wt of cement(as per manufacturer instruction) all as specified and as directed. 12 Supply only, integral water proofing compound, complete all as specified and directed by Engineer-in-Charge. 13 Material and labour for rendering 10 mm thick on ceiling, chajja etc , in cement mortar 1:3 finished even and smooth without extra cement, complete all as specified and directed by Engineer-in-Charge. 14 Material and labour for applying two coats of anti fungal weather proof grade exterior acrylic emulsion paint of approved tint @1.80 lit / 10 sqm (undiluted) as per approved manufacturers instruction over prepared and primed surface of external wall. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and directed. 15 Material and labour for applying waterproof cement based putty @0.80kg (undiluted) per sqm of average thickness 2.50mm in two coats on prepared / newly plastered wall (external/ internal) and ceiling surfaces in following steps- (i) Filling cracks in wall using crack seal compound Asian smart care crack seal or equivalent(ii) Mix the putty @ 0.8 kg/sqm by adding 35 to 40% water by volume or as per approved manufacturers instructions & mix it with electric putty mixer with mixing capacity of min 2.5 kg putty per minute upto 5 to 10 minutes(iii) Apply the first coat of prepared mix with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minute with max pressure 3300 PSI with bottom to top configuration and allow 6-8 hrs to dry the putty surface.(iv) Apply the second coat of prepared mix with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minute with maximum pressure 3300 PSI with horizontal configuration(v) Allow 6-8 hrs to dry putty surface then prepare the surface by electronic wall sander machine to apply subsequent coats of primer complete all as specified and directed. 16 Material and labour for applying one coat of acrylic water based exterior grade / interior grade primer @ 0.90 litre (undiluted) / 10 sqm diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 lit per minute having a pressure of 3300 PSI on prepared ceiling or internal / external walls surfaces. Allow 6 - 8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed. 17 Material and labour for complete removal of old existing treatment of wall (external/ internal) and ceiling finishes using mechanical dry wall sander machine (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 grit and above having dia of 7 /9 , complete all as specified and directed. 18 Material and labour for one coat of synthetic enamel paint including preparingold decoratedwooden/steelsurfaces of any description not otherwise described over 10 cm width or girthcomplete all as specified and directed. 19 Demolition of cement concrete in ground floor and paving not exc 15 cm thickness (below or above ground level) including floor tiles,screed bed etc complete all as specified. 20 Dismantling floor, hearth or wall tiling including cementmortar bedding (but not backing), removing serviceable tiles and rubbish off the premises etc complete all as specified and directed. 21 Material and labour for Vitrified tiles 10mm thick (square / rectangular) polished, light shade , area of each tiles not exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including. 15mm thick screed bed in CM 1:4complete all as specified and directed. 22 Material and Labour for Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including15mm thick in screed bed cement mortar 1:4 base, complete all as specified and directed. 23 Material and labour forcoloured glazed ceramic tiles of size 300mm x 450mm x 7mm thick in vertical surfacesand jointed in neat cement slurry and pointed in white or coloured cement to match including rendering 10mm thick in cement mortar 1:4 complete all as specified and as directed. 24 Material and labour forcoloured glazed ceramic tiles of size 600mm x300mm x 7mm thick in vertical surfacesand jointed in neat cement slurry and pointed in white or coloured cement to match including rendering 10mm thick in cement mortar 1:4 complete all as specified and as directed. 25 Material and labour for green marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of complete all as specified and directed by Engineer-in-Charge. 26 Taking downchowkhats or frames area exc 1.50 sqm and not exc 4.00 sqm (without taking off shutters from frame) and removing to site, including cutting holes for taking out existing hold fasts and making good in CM 1:3 complete all as specified and directed by Engineer-in-Charge. 27 Taking downchowkhats or frames area not exc 1.50 sqm(without taking off shutters from frame) and removing to site, including cutting holes for taking out existing hold fasts and making good in CM 1:3 complete all asas directed. 28 Supply and fixing 125x60mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and as directed. 29 Material and Labour 2nd class hardwood factory made 30mm thick glazed skelton shutters, open rebated and prepared to receive glass, gauge etc. divided into squares edges of framing, plain, chamfered or rounded, mitred fitted with cut and mitred beads for securing glass/gauge etc. with sizes of members of shutters as specified in SSR part-I section 8 clause 8.24(a), complete all as specified and directed by Engineer-in-Charge at site. 30 Supply and fixing factory fabricated flush shutters, 30mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed 31 Supply and fixing of anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) .with powder coating of any colour (Thickness or powder coating not less than 50 micron). complete all as specified and directed 32 Supply and fixing in repair in position of anodised aluminium powder coated (minimum thickness of powder coating 50 micron) three track window ( two shutters glazed & one shutters wire gauge) with frame section of suitable size for following sections, glazed with 5 mm thick tinted glass and, wire gauge with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm including rubber bead joining cleat for fixing in position, concealed type lock for all three shutter, PVC roller etc all as specified below, including the cost of EPDM rubber /neoprene gasket required complete all as specified and directed.(a) Frame (top & side) section shall of size 92.00 x 31.75 x 1.50 mm ( Section No 20831)(b) Frame (bottom) section shall of size 92.00 x 31.75 x 1.50 mm ( Section No 20832)(c) Top & side Members of shutter Section shall be be of size 18.00 x 40.00 x 1.55 (Section No 20738)(d) Shutter Interlock Section shall be be of size 18.00 x 40.00 x 1.45 (Section No 20737)(e) Bottom Members of shutter Section shall beof size 18.00 x 40.00 x 1.55 (Section No 20736)NOTE: - Section No given above are of make Jindal, Contractor may use similar section of other make mentionedin relevent Appx 33 Supply and fixing of Factory made mild steel door shutter with frame, fabricated from of 1 mm thickMS sheetincluding provision of steel handle and locking arrangement by providing 04 leaver lock with duplicate keys handle etc, (all as per Godrej pattern and detail shown on Drawing No. FD-1032 sheet 1/1 dtd 25.9.93) including spray painting over a coat of red oxide primer and fixed the same on existing cupboard nitch with cement and sand mortar, complete all as specified and directed by Engineer-in-Charge. 34 Material and labour for 12mm thickBlock boards, grade 2 quality, interior grade, decorative type with decorative face veneer on one face, complete all as specified and directed by Engineer-in-Charge. 35 Supply and fixing galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanesed wire stapels complete all as specifed and directed. 36 Supply and fixing 3 mm thick sheet glass ordinary quality not exc 0.50 sqm each pane and fixed with oil putty or with wooden beading in square etc complete all as specified and directed. 37 Supply and fixing Figured glass 3mm thick, ordinary quality and glazing with oil putty or wooden bead in squares not exceeding 0.5 Sq. m in each pane, including hacking out the same complete all as specified. 38 Supply and fixing mild steel framed work conforming to Fe-290 (Gde E-165), as in doors or gates of angle or other section with gusset plates, rails, braces, grills, etc. complete drilled for fixing steel sheeting or other covering to be prepare for hanging including either hooks or hinges etc. complete all as specified and directed. 39 Supply and fixing solid WPC door frame size ( 100mm X 65mm SingleRebate ) made from 100% LEAD FREE(single extruded process) material with density780 kg/Cum & Manufactured by an ISO: 9001-2015 certified company, all as per specification drawings as directed . The door frame should be Water Proof , Termite Proof , Fire Retardent and having excellent screw holding capacity, complete all as specified and directed by Engineer-in-Charge. 40 Supply and fixing of 30 mm thick moulded WPC factory made 100% solid door (confirming as per IS : 4020) made from 100% lead free single extruded with 2,4 or 6 raised panel design on the front side with 10mm deep mould on single side with wood grain texture and back side plain with density not less than 600kg/cum.Manufactured by an ISO: 9001-2015 certified company.The door should be water proof,termite rpoof,fire retardant and having screw holding capacity complete all as specified and directed. 41 Supply andfixing mild steel butt hinge of 100mm length, cold rolled, medium weight, complete all as specified and directed by Engineer-in-Charge. 42 Supply and fixing 200 mm long aluminium anodised barrel tower bolts of extruded sectioncomplete all as specified and as directed. 43 Supply and fixing 150 mm long aluminium handles, cast type anodised all as specified and as directed. 44 Supply and fixing 300mm long aluminium alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. 45 Taking up or down steel tubing and connections for 20mm dia including cleaning for refixing or removal to store complete all as specified and directed by Engr-in-charge. 46 Taking up or down steel tubing and connections for 15mm dia including cleaning for refixing or removal to store complete all as specified and directed by Engr-in-charge. 47 Supply and fixing Steel water tubing of 20 mm bore, medium grade galvanized, with all fittings laids in floor with wall ,complete all as specified and directed by Engineer-in-Charge. 48 Refixing old GI tuibing 20mm bore with all fittingsd as in walls, ceilings or floors etccomplete as specified and directed by Engr in charge. 49 Supply and fixing Steel water tubing of 15 mm bore, medium grade galvanized,with all fittings laids in floor with wall and on ceiling, complete all as specifiedand directed. 50 Material and labour for cutting chases for concealed water tubing and making good, cutting not exc 10 cm girth all as specified. 51 Material and Labour for PVC water storage tank 1000 Litre capacity HDPE triple layerfixed and hoisted in position on staging or roof complete with locking arrangement, over flow pipe, air lock pipe, Ball valves, tank nipple , high pressure of PTMT with,complete all as specified.including dismantling of old tanks of of any description complete all as specified. 52 Supply and fixing (in repair) vitreous china wash down water closet pedestal pattern (EWC) , White including connection to trap and to flushing pipe with ‘P’ or ‘S’ trap, making good to floor, plastic water closet seat cover with mild steel chromium plated hinges complete all as specified. 53 Supply and fixing (in repair) 15mm fancy type, chromium plated, angle cock,/ stop cock cast copper alloy, screwed down high pressure with crutch or butterfly handle, heavy with adjustable wall flange, complete all as specified.(Note : Weight of stop cock shall not be less than 0.575 Kg) 54 Supply and fixing ( in repair)15 mmCP bib tap screwed down high pressure, long body, cast copper alloy, chromium plated`with crutch or butterfly handles screwed down suitable for 15mm bore pipe or union, complete all as specified and directed by Engineer-in-Charge. (Note : Weight of bib tap shall not be less than 0.575 Kg) 55 Supply and fixing in repair vitreous china, white coloured, counter top wash hand basin, oval type, including cutting for and pinning , waste pipe complete all as directed by Engineer-in-Charge. 56 Supply and fixing in repair for 15mm fancy type WHB mixer, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. 57 Supply andfixingfor wall mixer with brass cast copper alloy, with flanged, chromium plated long body, screwed down high for 15mm bore pipe or unioncomplete all as specified and as directed by the Engineer-in-Charge. 58 Supply & fixed in repair 10 litre capacity Flush polypropylene cistern, , white at low level complete with PVC bend/flush pipe and making all connection including taking down existing high/low level cistern with all connections and making good the disturbed surfaces in cement mortar (1:3) to match with the existing surface, complete all as specified. 59 Supply and fixing, in repairs, 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC bldg Board or commercial plywood, fixedwith aluminium angled frame and two CP MS hanging arrangements all complete. 60 Supply and fixing in repair brass chromium plated shower rose complete as specified and directed. 61 Supply and fixing pegs set of 6 Nos, power coated aluminium body fixed with chromium plated screws complete all as specified and directed. 62 Supply and fixing in repairs toilet paper holder vitreous china fixed to walls with chromium plated (CP) brass screws complete all as specified and directed by Engr in charge. 63 Supply and fixing in repairs Soap dish CP , any type, fixed to plugs with chromium plate brass screws complete all as specified and directed by Engr in charge. 64 Supply and fixing in repairs CP towel rail of 600 mm long chromium plate brass screws complete all as specified and directed by Engr in charge. 65 Supply and fixing in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engineer-in-Charge. 66 Supply and fixed (in repair) PVC connections 450mm long and 15mm diaPTMT with PVC washers on both ends, complete all as specified and directed by Engineer-in-Charge. 67 Demolition& breaking up drain pipes any size/ typeSWG, PVC, concrete pipe including fittings or taking out from trenches/wall/ floor , if required, all complete all as specified and as directed. 68 Supply and fixing PVC (SWR) 110 mm pipe single socket in any length with rubber ring joints fixed to wall or infloors complete as specified and directed by Engr in charge. 69 Supply and fixing of 110mm dia PVC (SWR)bendany radius including jointing with solvent cement all as specified and as directed. 70 Supply and fixing for 110 mm PVC (SWR) junction single, (Single T) equal or unequal fitted with access door complete all as specified and directed by Engineer-in-Charge. 71 Supply and fixing PVC (SWR) 75 mm pipe single socket in any length with rubber ring joints fixed to wall or in floor complete all as specified and directed by Engr in charge. 72 Supply and fixing PVC (SWR) bends 75 mm bore any radius including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge. 73 Supply and fixing PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete as specified and directed by Engr in charge. 74 Demolition of brick work built in cement mortar including all arches, pillars etc all as specified and as directed by Engineer-in-Charge. 75 Demolition of RCC in Roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar suspended work etc complete all as specified and directed. 76 Material and labour for Brickwork with subclass ‘B’ bricks, straight or curved on plan exceeding 6 meter mean radius built in cement mortar 1:4 complete all as specified and as directed. 77 Material and labour for Brickwork with subclass ‘B’ bricks,(Except Brick) straight or curved on plan exceeding 6 mtr mean radius of walls built in CM (1:4) complete all as specified and as directed. 78 Material and labour for plain cement concrete 1:3:6, type C-2 (using 40 mm mechanically graded crushed stone aggregate), as in 75mm thick plinth protection, finished even and smooth without using extra cement, and laid in bays jounts filled with bitumen and sand mixture applied hot complete all as specified and directed. 79 Material and labour for reinforcement cement concrete 1:2:4 type B-1(using 20 mmgraded aggregate) as inslab ,supported on walls , shelves etc complete all as specified and directed. 80 Material and labour MS TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending and bindingwith and including annealed MS wire not less than 0.90 mm dia as required and as directed by Engineer-in charge. 81 Material and labour for formwork forsoffits of suspended slab as roof slab landing and similar work not exc 200mm thick (horizontal and sloping) flat rough finished surfaces of concrete, complete all as specified and directed by Engineer-in-Charge. 82 Material and labour 20 mm thick black granite stone slab of any type with table rubbed and polished in cooking platforms and like set in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite slab complete all as specified and directed. 83 Material andLabour for preparation of exposed brick wall surface by cleaning the surface by wire brush to remove all dirt/loose materials from the bricks and from the joints between the bricks. Prepared surface should be then washed with diluted HCL acid (dilution ratio of 1:50) for three times in a day for two days. After acid wash surface should be allowed to be air dried for one day, complete all as specified and directed by Engineer-in-Charge.NOTE : - Further treatment over the surface so achieved will be carried out only after approved of the same by GE. 84 Supply and fixing of20 mm dia stainless steel D type curtain rod with latto/ brackets etccomplete all as specified and directed by Engineer-in-Charge. 85 Material and labour for effloresence treatment to unplastered wall surface comprising of the following specification including 15 mm thick renderingcomplete all as specified and as directed.(a) Prime the prepared surface with one of the following product mixed with cement in 1:1 ratio as bonding agent : -(i) Pidicrete URP of M/S Pidilite. (ii) Sika Latex of M/S Sika.(iii) Nitobond SBR Latex of M/S FOSROC.(b) Immediately after priming the surface PMM (Polymer Modified Mortar) to be applied “BY HAND” while the prime is tacky. PMM should be prepared by mixing one of the following compounds in Cement Mortar 1:3 as per manufacturer’s instrs: -(i) Pidicrete URP of M/S Pidilite.(ii) Sika Latex of M/S Sika.(iii) Nitobond SBR Latex of M/S FOSROC.(c) PMM surface should be allowed to dry for one day. After that it should painted with two coats of one of the following compound mixed with cement only in ratio of 1 (selected compound) : 1:5 (Cement) : - (i) Pidicrete URP of M/S Pidilite.(ii) Sika Latex of M/S Sika. (iii) Nitobond SBR Latex of M/S FOSROC. (d) Now apply two coats of one of the following compound over the surface. These compounds are to be used as per manufacturer’s instructions: -(i) Pidifin 2K of M/S Pidilite (ii) Brush Coat of M/S Sika.(iii) Brush Bond of M/S FOSROC. (ii) Every stage of work will be approved by GE, then only next layer will be executed by contractor. Notes: (a) The efflorescence treatment shall be carried out by the manufacturer or his authorised representative only. (B) The efflorescence treatment shall be carried out after taking down existing plaster redoing external/internal plaster under respective Items as approved by GE. 86 Material and labour for 100 mm thick plain cement concrete 1:4:8 type D-2 using 40mm mechanically crushed graded stone aggregate as in sub base complete all as specified and directed 87 Material and labour for Machine pressed precast concrete interlocking paver block any shape and size conforming to IS- 15658-2006 of 60 mm thickness M-35 grade with grey cement and pigment finished with coloured rubber finish on top finished over sand dust cushion complete all as specified and directed. 88 Material and labour Sand filling under interlocking paver block including watering and consolidation complete all as specified and directed. 89 Removing excavated surplus soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5 m above the starting point, complete all as specified and directed by Engineer-in-Charge. 90 Material andLabourfor plain cement concrete 1:3:6 type C-1(using 20 mm mechanically graded crushed stone aggregate) as in surface channel/drains , complete all as specified and directed by Engineer-in-Charge. 91 Material and labour for extra for forming fair finish be drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped complete all as specified and directed by Engineer-in-Charge. 92 Taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc, complete all as specified and directed by Engineer-in-Charge. 93 Taking down Ceiling fan any size or any type and deposited to MES store yard complete all as specified and directed. 94 Taking down Exhaustfan any size or any type and deposited to MES store yard complete all as specified and directed. 95 Taking down old Water Heater (Geyser) any type/Size/Capacity with all accessories after removing of all incoming/outgoing pipe line connection and deposited to MES Store Yard for repair complete all as specified and directed. 96 Taking down old unserviceable underground cable/Service wireof any size/type complete all as specified and directed 97 Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (FIRE Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic,medium grade PVC concealed conduit not less than 20mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxeswith GI metal flushboxes made out of 1.2mm thick of any module from 2 to 18module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paintincluding modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbedsurfaces as per existing for one light / fan point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dollywith suitable size of lugs for one light point/ fan point/bell point/exhaust point controlled by one switch complete all as specified and as directed.NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately.2. All chases will be cut by chase cutter only. 98 Description all as per item No 97.00 here in before but for socket out let point 5 Amps on same board, complete all as specified and directed by Engineer-in-Charge. 99 Description all as per item No 97.00 here in before but for socket out let point 5 Amps on independent board, complete all as specified and directed by Engineer-in-Charge. 100 All as per srl item No 97.00here in before but point wiring for one socket out let 15 & 5 Amps (independent) controlled by one switchwith using 2.5 Sq mm (nominal area) stranded copper conductor, complete all as specified and directed by Engineer-in-Charge. 101 Supply and fixing in repair modularswitch 5 Amps, flush type, single pole, one way,230 volt , AC supply, complete all as specified and directed by Engineer-in-Charge. 102 Supply and fixing in repair modular switch 15 Amps, flush type, single pole, one way,230 volt , AC supply, complete all as specified and directed by Engineer-in-Charge. 103 Supply and fixing in repair modularsocket outlet 3 pin 5 amps, 230 volts flush type ,, complete all as specified and directed. 104 Supply and fixing in repair modularsocket outlet16 amps, 230 volts flush type ,, complete all as specified and directed. 105 Supply and fixing in repair modularfan regulator step type one module/2 modules, 120W,50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified. 106 Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified. 107 Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed by Engineer-in-Charge. 108 Supply and fixing of LED light fitting 1x20W , 220V,not less than 100 lumen per watt, AC batten type with driver , holder including 20W LED tube light for connecting up with three core flexiable copper conductor cable of suitablae size from celing rose to connector complete all as specifid and directed. Note: LED cool white/warm white must get approved from engineer-in-charge. 109 Supply and fix batten type withsurface mounted LED tube light fitting with high efficient diffuser mirror light, polycarbonate housingin CRCA body suitable and including 10 watt LED tube rod high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.Note: LED cool white/warm white must get approved from engineer-in-charge. 110 Supply and fixingbracket for security light made up of 25/40mm dia suitable for security light, 0.9 metre long MS pipe,light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed. 111 Supply and fixing LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDshaving optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down oldunserviceable security light fitting of any description and in any positioncomplete all as specified and directed. 112 Material and labour for sub main wiring with two single core FRLSH PVCinsulatedunsheathed copper conductor cable 6.0 sq mm drawnin and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSHof 6.0 sqmm,green colourfor earthcontinuity conductor including taking down old unserviceable sub main wiringand making good the disturbed surface complete,all as specified and directed. 113 Supply and fixing sheet metal enclosures vertical distribution boardVTPN, (MCCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole, 125A, 25 KA as incomerand MCB sas out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangementincluding and making connection with suitable size of lugs and making good the disturbed surface matching with existing surface all as specified and directed. Note: (i)Painting shall be done with powder coated finish.(ii)PU(polyurethene) gasket shall be used in DB. 114 Supply and fixing, insatallation, testingofSPN distibution board 8 way,double door , IP 43 , as per IS 8623including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles, all as specified and directed.Note: (i)Painting shall be done with powder coated finish.(ii)PU(polyurethene) gasket shall be used in DB. 115 Supply and fixing MCB SP single pole, 240 volts, 50 Hz, breaking capacity , 6 to 32 Amps, complete all as specified and directed by Engineer-in-Charge. 116 Supply and fixing SPN 40 -63 Amps rating ,240 volts, 50 Hz, breaking capacity 10 KA completeall as specified and directed. 117 Taking out old unserviceable earthing and material & labour for earthing with Galvanised Steel earth plate electrode 60cmx 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer ofcharcoal dust and common salt filling in alternate layers and electrode connections by usingGalvanised iron wire 4 mm as earthing lead(upto terminal point) by means ofbolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 15 mm diaGI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6)type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type ofsoil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 ofSSR 1991(Part-I) complete all as specified and as directed by Engineer-in-charge. Note : The rates for earth work, GI protection pipe, funnel, wire mesh, CI cover, etc shall be deemed to beincluding in quoted rates. 118 Supply and fixing MCB SP single pole, 240 volts, 50 Hz, breaking capacity , 40-63Amps, complete all as specified and directed by Engineer-in-Charge. 119 Supply and fixing cable protection GI Tubes of bore 50 mm ,light grade ,with all fittings and fixed complete to walls and ceilings or laid in floors,complete all as specified and directed. 120 Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty Under ground XLPEcable with PVC insulated aluminium, stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed25 sq. mm 4 core nominal cross sectional Areacompleteall as specified and directed by Engineer-in-Charge. 121 Excavation in trenchesnot exceeding 1.5 Mtrs wide and not exc. 1.5 Mtr deep and getting out soft/loose soil complete all as specified and as directed by Engineer -in-Charge 122 Returning, filling in including spreading levelling , watering and well ramming in layers not exc 25cm thick after the cable have been laid testing complete all as specified and directed by Engineer -in-Charge 123 Material and Labour for unwashed dry sand cushioning for cable protection , fillingin treches complete all as specified and directed by Engineer-in-charge. 124 Material and Labour for Protection to cable with one layer of new bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks complete all as specified and directed. 125 Re-fixing Ceiling fan of any size/makeafter minor repair,servicing and greasing including painting complete all as specified and directed. 126 Re-fixing Exhaust fan of any size/makeafter minor repair,servicing and greasing including painting complete all as specified and directed. 127 Re-fixingGeyserof any capacity and make for servicing and replacement of defective parts including painting two coats of white duco painton same or other location after making and functional and making water connection ofinlet/out pipecomplete all as specified and directed. 128 NOTE:- Amount of credit ofRs. 92,963.00 for retrieved materials is mentioned in Schedule of Credit Page No 21.00 & 22.00 of tender documents in pdf form which will be deducted offline while acceptance of tender.