Tender For Special Repair To Building No P-245 (Comn Complex) At Leimakhong Mil Stn Under Ge 869 Ews; 2 Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles and removing unserviceable materials from site of work complete all as specified and directed. 3 M&L brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and directed. 4 M&L for brick work with sub class ‘B’ brick, old size (locally available best quality) straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:6) complete all as specified and directed. 5 Taking down of cement plaster inculding wall finishes in any description on brick or stone wall etc., incl hacking out joints for key scrubbing down with water etc. all as specified and directed.Note: Rates deemed to be inclusive of scaffolding upto 12 mtr height 6 M&L for rendering 15mm thick in CM 1:4 onon fair surfaces of brick in two separate coats (10mm thick backing coat and 5mm thick top coat) using water proofing compound @2% by weight of cement as per manufacture instruction and finishing works/concrete surfaces finished even and smooth complete all asspecified and directed.Note :(i)WPC will be measured and paid separately (ii)Rates deemed to be inclusive of scaffolding upto height 12 Mtr at reqd places. No additional payment will be made on this account. 7 Supply only intergral water proofing compound complete all as specified and directed. 8 M&L for rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in CM 1:6 finishing even and smooth without using extra cement complete all as specified and directed. 9 M & L for rendering 5mm thick on fair face of brick work or concrete surface wall or ceiling in CM 1:3 finishing even and smooth without using extra cementcomplete all as specified and as directed. 10 M&L for preparation of new surface including necessary scaffolding and applying finishing walls with Acrylic Smooth exterior paint of required shadeNew work (Two ormore coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) as per manufacturers instrt complete all as specified and as directed. 11 M&L for preparation of surfaces plastered or unplastered new surface on wall and applying two coats of oil bound distemper complete all as specified and directed. 12 M&L for preparation of surface plastered or unplastered new surface on ceiling and applying three coats of white wash complete all as specified and directed. 13 M&L for complete removal of existing finish andpreparation of old plastered surface including necessary scaffolding and applying two coats of acrylic exterior paint over a coat of primer (brand apcolite Apex manufactured by Asian or Brand weather coat manufactured by Berger or equivalent as approved by GE) complete all as per manufacturers instructions and directed. 14 M&L for complete removal of existing finish, scrapping and making good surfaces on old surface of walls and applying two coat of oil bound distemperover a coat of 1mm thick wall care white putty all as specified and directed. 15 M&L for preparation of surface plastered or unplastered old surface on ceiling and applying one coat of white wash complete all as specified and directed. 16 Demolition Cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thicknessbelow or above ground levelcomplete all as specified and as directed. 17 M& L PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in benching of drain, surface channel complete all as specified and directed. 18 M&L for Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement incl forms, molds mitred / stopped ends etc complete all as specified and directed. Note:- (1) Using Dimapur sand. 19 M&L for 75mm thick cement concrete type C2 1:3:6 using 40 mm graded stone aggregate as in plinth protection including finishing cement concrete surfaces even and smooth without using extra cement complete all as specified and directed.(Using dimapur sand) 20 M&L for forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade A complete all as specified and directed. 21 Dismantling floor hearth or wall tiling including cement mortar bedding(but not backing) removing serviceable tiles to store & rubish of the permises complete all as specified and directed. 22 M&L for Non -skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exc 0.38 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shade and includig 15 mm thick screed bed in CM 1:4 complete all as specified and directed. 23 M&L for25mm thick PCC 1:2:4 type B1(using 20mm graded stone aggregate) as in levelled course finish even and fair for tilefinishes complete all as specified and directed by Engr in Charge. 24 M&L for Non -skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exc 0.11 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shade and includig 15 mm thick screed bed in CM 1:4 complete all as specified and directed. 25 M & L for Glazed Coloured Ceramic tiles in vertical surface 350x250x7mm / 450x350x7mm thick and joint in neat cement slury and pointed in white or colour cement to match over and including 10mm thick plaster in CM 1:4 as backing coat to receive tiles complete all as specified and directed. 26 M & L forNon skid coloured ceramic tiles 7 to 8mm thickof each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in Skirtingetc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and includingrendering 10 mm thick on fair faces of brick work in CM (1:4) for receving vertical dado tiling complete all as specified and directed. 27 M&L for 75 mm thick PCC 1:3:6 grade (Nominal mix) Type C2 (using 40mm graded crushed stone aggregate) as in sub base finishing cement concrete surfaces even and smooth without using extra cement complete all as specified and directed.(Using dimapur sand) 28 M&L for 30cm x30cm x25 mm thick pre-polished coloured chequred tiles made with using grey cement and pigment, smooth finish exterior grade precast heavy duty shine finish paver tiles in floor laid over 15mm thick screed in CM 1:4, set & jointed and pointed with grey cement and pigment complete all as specified and as directed. 29 Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sqm but not exc. 4 sqm eachcomplete all as specified and directed.. 30 Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m eachcomplete all as specified and directed. 31 Taking down shutter of any description exc 1sqm but not exc 2 Sqm each and removing unserviceable materials from site of work complete all as specified and directed. 32 Taking down shutters of any description exc 1 sqm and not exc 2 sqm each including easing and adjusting and also refixing builder hardware as required including renewal of unserviceable screw and necessarry materials refixing shutter in same opening complete all as specifeid and directed. 33 S&F 2nd class hardwood plain solid straight chowkhats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed. 34 S&F 30 mm thick factory made flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete all as specified and as directed. 35 Supply and fix solid PVC door frame of size 50mm x 47mm made out of 5mm single piece extruded PVC profiles reinforced with 19 x 19mm MS square tube provided with EPDM rubber gasket weather seal through out the frame and the profile mitre cut at two corners and joined by inserting 2 nos 150mm long brackets of 15 x 15mm MS square tube inside 19 x 19mm MS square tube suitably screwed complete all as specified and as directed. 36 Supply & fixfactory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes of size 15 x 15mm for top andbottom rails and 19 x 19mm for stiles, MS frame covered with 5mm thick single piece extruded PVC profile C channel having a 5mm thick PVC sheet strip of 20mm width struck inside with solvent cement, forming stiles, and 5mm thick single piece extruded PVC profile for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail; panelling of 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with PVC sheet beading, and joined together with solvent cement adhesive etc all as per manufacturers instructions and drawings as shown in SSR Part-I 2009 complete all as specified and as directed. 37 S&F floor door stopper of aluminium alloybody and tongue with hard drawn steel springwith 140mm overall length of cover plate complete all as specified and directed. 38 S&F 100mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed. 39 S&F 150mm long aluminium anodised of extruded section barrel tower bolts complete all as specified and directed. 40 S&F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolt of extruded section or cast aluminium alloy and fixed 300mm long complete all as specified and as directed. 41 S&F mild steel flat iron as in hold fast including screwing or welding complete all as specified and directed. 42 M&L providing cement concrete 1:3:6 type C1 using 20mm graded stone agg as in hold fast complete all as specified and directed. 43 S&F for Anodised aluminium frame for doors,windows, ventilators and partationwith one or more rebates including all necessary joining cleat, lugs, breading and jointing arrangement for fixing etc complete all as specified and directed. 44 M&L for Anodised aluminiumsliding window, 3 track system and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc.including all fitting complete all as specified and directed. 45 M&L for 4.8mm thick plain tinted sheet glass ordinary quality in squares exc 0.5 Sqm each pane for aluminium window, complete all as specified and directed. 46 M&L for 4.8mm thick plain tinted sheet glass ordinary quality in squares not exc 0.5 Sqm each pane for aluminium window, complete all as specified and directed. 47 S & F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. 48 S&FAnodised aluminiumof any colourdoor shutters , aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges, anodised aluminum snap beading, screws etc. including all fittings complete all as specified and directed. 49 Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed. 50 S&F exposed GI powder coated snap grid frame work for false ceiling of grid size 600 x600mm comprising of wall/cleat angle of size 25 x25 x0.35mm and main/cross tee of size 24 x38 x0.70mm with 2mm dia GI wire as suspender and including 4mm thick Plain E-Boardincluding fixing arrangement from steel truss of any type and applying two coats of oil bound distemper over one coat of chalk whiting complete all as specified and directed. 51 Dismantling wrought iron or mild steel work of any description not otherwise provided forcomplete all as specified and directed. 52 S&F rolled mild steel Fe-410w (Gde-E-250) quality A Roof trusses (framed) , trussed, purlins, crane gantries , rails and fastening and havy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces cleats etc complete all as specified. 53 Errection and fixing only rolled mild steel Fe-410w (Gde-E-250) quality A Roof trusses (framed) , trussed, purlins, crane gantries , rails and fastening and havy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces cleats etc complete all as specified.(Note :-serviceable Roof trusses (framed) , trussed, purlins, crane gantries, etc obtained from under relavant items) 54 M&L for applying two coats of synthetic enamel paint over a coat of red oxide including preparation of new or previously untreated steel surfaces of any description not other wise described over 10 cm with or girth complete all as specified and directed. 55 Demolition of stone slabs and tiles of any description or thickness in floors laid bedded and pointed in any mortar complete all as specified and directed. 56 M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including screed bed 20mm thick inCM 1:3 complete all as specified and directed. 57 M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations completed all as specified and directed. 58 S& F in reapirVitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed. 59 S&F in repair of PVC seat cover for pedestal pan, white closed pattern with flat bottom and cover and mild steel chromium plated or aluminumized hinging device complete all as directed. 60 S&F in repair Vitreous China urinal, half stall type white with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement etc complete all as sapecified and directed. 61 S&F in repair, Vitreous china wash basin, white oval shape, size 550 x 400 mm excl taps, wastechain and plug and porcelain stopper but incl brackets, waste pipe & CP waste coupling complete all as specified and as directed. 62 S&F in repairs Pillar taps, 15mm dia cast copper alloy, with capstan heads, chromium plated, but fancy type screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. 63 S&F in repair PVC flushing cistern syphonic action type,10 litters capacity, low level white with inlet ball, valve, float and handle including bracket ,PVC Connection and flush pipe complete all as specified and as directed. 64 S&F PVC (SWR)floor trap with grating with incl jointing to waste pipe fixed in cement concerete (1:2:4) diameter of outlet pipe 75mm complete all as specified and as directed. 65 S&FPVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed. 66 S & F in repairs bib taps, ISI marked cast copper alloy, chromium plated fancy typescrewed down, screwed for iron pipe or for brass ferule for 15 mm bore dia ofpipe complete all as specified and directed. 67 S&F in repairs fancy type stop valves 15mm cast copper alloy chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed. 68 S&F in repair brass chromium platedtowel rail 20 mm dia, D type600mm long between flanges with brackets fixed to walls with brass screws etc.complete all as specified and directed. 69 S&F in repair600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. 70 S&F of sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long fixed to wall with screws complete all as specified and directed. 71 Taking up or down 15mm dia of steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and directed. 72 S&F GI tubing 15mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. 73 Cutting chases, pinning in. making good to facings of brick walls where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed. 74 Taking up or down 20mm dia of steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and directed. 75 S&F GI tubing 20mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. 76 S&F in repair 75mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall or laid in floor weight of pipe not less than 0.70 Kg/Rm complete all as specified and as directed. 77 S&F in repair 110mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall or laid in floor weight of pipe not less than 0.70 Kg/Rm complete all as specified and as directed. 78 S&F 110mm dia PVC SWRbranch bends of any radius with acess door complete all as specified and as directed. 79 S&F in repair PVC (SWR), junction single, (Single T) equal or unequal 110mm dia with access door complete all as specified and directed. 80 S&F in repair PVC (SWR), junction single, (Single T) equal or unequal 75mm dia with access door complete all as specified and directed. 81 S&F in repair 75mm dia PVC SWRbranch bends of any radius with acess door complete all as specified and as directed. 82 Dismantling Water Tanks & removing from site to store of capacity of tanks 500 ltr and n exc 1000 ltr complete all as specified and directed. 83 S&F rotational moulded polyethylene water storage tank, ISI marked,1000 litres capacity of multilayered layer wall construction (Cylindrical, vertical with closed top) hoisted and fixed in position including all necessary inlet/outlet connections and including 20mm bore brass ball valvecomplete all specified as directed. 84 S&F in repair 20mm bore Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all complete as specified and as directed. 85 Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coveringscomplete all as specified and directed. 86 S&F Pre-Painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified. 87 S&F Pre-Painted galvantume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified. 88 S&F 0.63mm thickgalvanised corrugated mild steel sheeting with two corrugation side lap fixed with J type hook bolt and washer or self tapping screws in roof, wall etc.with grade of zinc coating 275 complete all as specified. 89 M&L for preparation of new zinc (or galvanised) surfaces to receive painting by coating with mordant solution including washing and cleaning etc and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed. 90 S&F for Fibre glass reinforcedtranslucent corrugated sheeting 2mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc.complete all as specified and as directed. 91 Taking down existing unserviceable treatment of any description including cement plaster any thickness from roof surfaces, cleaning of roof surfaces and preparing it for further treatment and removing rubbish from the site upto distances 50 mtrs complete all as specified and directed. 92 M & L for Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed. 93 M&L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in cement mortar(1:4) using water proofing compound @2% by weight or cement as per manufacture instruction and finishing even and smooth without using extra cement all as specified. (Note: Plastering shall be carried out using Dimapur Sand.)Note: WPC will be measured and paid separately) 94 M&L for APP based polymeric membrane minimum weighing 3.5kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 160 gms/sqm) including priming of surface with one coat of bituminous primer @ .40ltr/sqm and applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm including cleaning surfaces complete all as specified and directed. Note:- The aaplication of plolymeric membrane shall by torch 95 M&L for applyingone coatAluminium paint over APP based polymeric membrane or Surfaces of any description, over 10cm in width or girth, not otherwise describedcomplete all as specified and directed. 96 Supply and fixedaluminium (extruded section body) door closer hydraulically regulated designation No-3 universal type, suitable for door shutter of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. 97 S&F in repair three lever lock for aluminium door complete all as specifed and directed. 98 S&F in repair fancy type harrison rails of anodised aluminium alloy with fixing brackets, stops, rollers etc, of 20mm dia for window and doors with curtain rings and decorative doom holdersfixed to wall with screw complete all as specified and directed. 99 Taking down carefully unserviceable aluminum/ copper point wiring (light/ fan/ socket/ power) complete including fixture & fitting such as switches, sockets, ceiling roses regulators, lamp holder etc. but excluding light fittings & fixture and exhaust fans etc removing and making good disturbed surfaces of wall/ceiling etc completeall as specified and directed. 100 Material and labour for point wiring concealed type with two single core 1.5 Sq mm (nominal area) FRLSH PVC insulated 1100 volts grade and unsheathed, multi-stranded, copper conductor single core cable through and including concealed wiring 20 mm pvc rigid conduit with allfixing accessories and suitable including 1.6 mm thick size sunk MS pressed steel modular box including suitable size of white modular frame with cover plate for mounting modular switches,sockets and regulator etc includingmulti-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 1.5 Sq mm andconnecting to light fitting/fans etc completeall as specified and directed for following :- (Colour code to be followed) (a)One light point controlled by one, one way switch.Note :-(i) The quoted rate shall be deemed to be inclusive mild steel sunken boxes/modular cover plate and cutting chases in brick wall/ pillars etc for concealing the depth and making good the disturbed surfaces in CM 1:4 including finishing the surface to match with the portion of point wiring at for covering/ fix sunken boards/ terminals.(ii) Fiitings like switches, sockets, regulators, lamp holders, light fitting etc shall be measured and paid for separately of concern item of Sch A. 101 One ceiling/exhaust fan point controlled by one, one way switch 102 One socket outlet 5 Amps 3 pin on same board with other switch 103 One socket outlet 5 Amps 3 pin on independent board with cable of 1.5 sqmm sizecomplete all as specified and directed. 104 All as per item No. 99.00 here-in-above but with cable size 2.5 Sqmm for one 3 pin, 15 Amps socket outlet on independent board and multistrand insulator copper earth continuity conductor of size 2.5 Sqmm complete all as specified and directed. 105 All as per item No. 99.00 here-in-above but with cable size 4 Sqmm for one 3 pin, 15 Amps socket outlet on independent board and multistrand insulator copper earth continuity conductor of size 4 Sqmm complete all as specified and directed. 106 S&Fmodular switch , 6 Amps, single pole, one way complete all as specified and directed. 107 S&Fmodular switch , 16 Amps, single pole, one way complete all as specified and directed. 108 S&F modularsocket outlet 2/3 Pin 6 Amps combined 2 module complete all as specified and directed. 109 S&F modularSocket multipurpose 3 pin 16 Amps and 3 pin 6 Amps combined 2 module complete all as specified and directed. 110 S&F modular electronic fan regulator rotary stepped type 120W, 240V, single phase, two module and connecting up complete all as specified and directed. 111 S&F Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body complete all as specified and directed. 112 M&L in repair for submain wiring with two core 10 sqmm PVC FRLS insulated unsheathed cable multi stranded copper conductor drawn through and inclduing PVC casing / capping of suitable size with all fittings and fixing accessories on roof , walls, ceiling etc including 10 Sqmm PVC insulated unsheathered one core multistranded copper condutor earth wire complete all as specified and directed.(Note : Two run of single core cable and one run earth wire will be measured as one length 113 M&L in repair for submain wiring with two core 4 sqmm PVC FRLS insulated unsheathed cable multi stranded copper conductor drawn through and inclduing PVC casing / capping of suitable size with all fittings and fixing accessories on roof , walls, ceiling etc including 4 Sqmm PVC insulated unsheathered one core multistranded copper condutor earth wire complete all as specified and directed.(Note : Two run of single core cable and one run earth wire will be measured as one length 114 M&L in repair for submain wiring with two core 6 sqmm PVC FRLS insulated unsheathed cable multi stranded copper conductor drawn through and inclduing PVC casing / capping of suitable size with all fittings and fixing accessories on roof , walls, ceiling etc including 6 Sqmm PVC insulated unsheathered one core multistranded copper condutor earth wire complete all as specified and directed.(Note : Two run of single core cable and one run earth wire will be measured as one length 115 S&F in repair sheet metal enclosure DB, TPN, IP 43 protection, double door, 240 volts, Vertical Type 4 way including 200 Amp rated busbar, neutral link, din rail suitable for mounting MCBs of minimum 415 Amps rating complete all as specified and directed. 116 S&F in repair sheet metal enclosure for MCB’s distribution board, 240 Volts, 12 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door Type for breaking capacity 10 KA complete all as specified and directed. 117 S&F in repairMCB Triple pole and neutral 40 to 100 Amps, ‘C’ series 415 Volts, breaking capacity 10KA complete all as specified and directed. 118 S&F in repair MCB single pole 06 to 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. 119 S&F in repair MCB single pole and neutral 40 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. 120 S&F in repair MCB single pole and neutral 40 to 63 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. 121 Taking down ceiling/exhaust fan including dismantling all necessary electrical connections and kept in safe custody for refixing to its original position to facilitate repairs to ceiling/wall complete all as directed. 122 Refixing only ceiling fan (M D Supply) removed under item Srl No 120.00 here-in-above and connecting upincluding provision of cable from ceiling rose or connector to fan complete all as directed. 123 Refixing exhaust fan removed under item Srl No 120.00 here-in-above and connecting upincluding provision of cable from ceiling rose or connector to fan complete all as directed. 124 M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized earth wire 4mm dia by means of galvanized iron or steel bolts nuts check nuts and washers and other end connected with earthing testing point including providing suitable testing points as directed including funnel, watering pipe of 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1 cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work in hard/dense soil as required complete all as shown in electrical plate No 3 of MES Schedule Part I and testing on completion all as specified and as directed.(Note: Earth strip beyond 7.5 m length will be measured & paid separately) 125 S&F in repair LED luminaire 600 mm x 600 mm, 35/36 Watt, 220 V ACrecessed type white/warm with high efficiency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for roof ceiling including connceting up with driver three core flexible copper conductor cable of suitable size complete all as specified and directed. 126 Taking down LED luminaire 600 mm x 600 mm, 35/36 Watt, 220 V ACrecessed type white/warm light and kept in safe custudy and refixing at same placecomplete with driver, holder & LED lamp including connceting up with driver three core flexible copper conductor cable of suitable size complete all as specified and directed. 127 S&F in repair LED tube lights fitting 1x10 Watt , 2 feet, 220 V , AC decorative box type white/warm with driver , holder including LED tube light 10W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. 128 S&F in repair LED tube light fitting 1x20 Watt , 4 feet, 220 V , AC decorative box type white/warm with driver , holder including LED tube light 20W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. 129 S&F in repair building security light fitting new generation energy saving & environmental friendly long life versatile pressure die cast aluminium housing with acrylic cover as diffuser with IP-66 high power LED light 25 watt including suitable size of wall bracket and connecting complete all as specified and directed. 130 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, poles struts, laying of cable/ pipes etc n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. 131 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soft/loose soil complete all as specified and as directed. 132 Removing excavated material/soil not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 133 Supply and spread sand in trenches as sand cushioning to underground cable for protection with dry fine river sand and provide required cover after punning down 18CM will be measured and paid complete all as specified and directed. (Note: Thickness of sand cushion after punning down will be measured and paid.) 134 Supply and laying wellburntsub class‘B’ bricks( designated 75) locally available best quality, laid dryin trenches forprotection of underground cable complete all as specified and directed. 135 Supply, laying, Jointing and testing in repair of LTUG cable XLPEinsulated,PVC bedded galvanised steel strip or wirearmoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 70 sqmm 3.5 core laid in trenches/ on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed. 136 Supply, installation , testing and commissioning of LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3.0 mm thick sheet for outer and 1.6 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outoor, floor mounting type with closed bus bar , chamber and with copperbus barwith necessary insulators suitable for 3 phase, 4 wire 50 Hz AC supplyas per CPRI approved including provn of digital Am-meter 0-300A,digital Volt-meter 0-500 Volts, CTs of suitable ratio,indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following work alsoincludes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc. The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron(Main Panel)Alluminium bus bar capacity 400 Amps for Phase-R-Y-B- & neutralMCCB FP 250 Amps 35 KA- 01 Nos MCCB FP 100 Amps 16 KA- 04 NosDigital voltmeter, ammeter and indicator lamp of suitable capacity- 01 137 M&L in repair for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized earth strip of size 32 x 6 mm by means of galvanized iron or steel bolts nuts check nuts and washers and other end connected with earthing testing point including providing suitable testing points as directed including funnel, watering pipe of 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1 cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work in hard/dense soil as required complete all as shown in electrical plate No 3 of MES Schedule Part I and testing on completion complete all as specified and as directed.(Note: Earth strip beyond 7.5 m length will be measured & paid separately)