| 1 | Dismantling old/damaged plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground with in 50 meters lead including providing scaffolding as and where required with all required material,hardwares and consumables to complete the job. |
| 2 | Providing and applying rust inhibition coating/system to exposed reinforcement bars,after thoroughly removing all loose scales and rust, in accordance with standard specifications.Providing and applying a suitable bond coat to all exposed concrete surfaces and reinforcement bars prior to the application of repair mortar, as per the specified standards.Providing and applying a single-component, fiber-reinforced, thixotropic structural repair mortar of average thickness 50 mm and above, using BASF (MasterEmaco 348 S) or equivalent, in multiple layers as per manufacturer’s specifications.Curing the repaired surface after 72 hours of application using wet gunny bags or other standard curing methods. |
| 3 | Providing and laying internal plaster in C.M.(1:3)12mm thick minimum to concrete surface in any location and at all levels including cleaning and watering the surfaces,filling out hollows or out of plumb surfaces with mortar and finishing to correct line and plumb etc. including providing scaffolding as and where required with all required materal,hardwares and consumables to complet the work as directed by EIC |
| 4 | Providing and applying painting work using oil-bound washable distemper of approved brand such as Asian Paints, Dulux, or equivalent, of first/premium quality in the required shade and color, to achieve a smooth and even finish on any surface.The work shall include the application of two or more coats of distemper at a coverage rate of 2.20 kg per 10 sq.m, over a primer coat applied at 0.80 litre per 10 sq.m, including the cost of primer.The work shall be executed at any location in executive cabins of EMF Buildingand all levels, including:Surface preparation, Scaffolding andAll other necessary arrangements to complete the work in a professional manner.All work is to be carried out as per manufacturer\"s specifications and as directed by the Engineer-in-Charge (EIC). |
| 5 | False Ceiling Grid System:Size: 600 mm x 600 mm modular gridFrame: 24 mm wide GI (Galvanized Iron) T-grid membersGalvanization: Hot-dip galvanised with minimum 90 GSM zinc coatingMetal Ceiling Panels:Size: 600 mm x 600 mmThickness: 0.45 mm to 0.5 mmMaterial: Factory-fabricated pre-coated metal panelsFinish:Top surface: Minimum 20-micron polyester paint coatingBack surface: Minimum 8-micron epoxy coatingInstallation Details:Installation to be done with necessary suspension system including GI Wire 4-5 mm, Hot-dip galvanized with minimum 90 GSM zinc coating to ensure rust and corrosion resistance To hook and suspend the false ceiling grid system (600 mm x 600 mm T-grid system).Wire to be fixed at uniform equidistant points to maintain level, alignment, and load distribution as per ceiling layout with anchors, intermediate channels, etc.All required hardware, fasteners, brackets, and consumables shall be included.Work shall be carried out in line, level, and plumb as per manufacturer’s instructions and EIC direction.Completion Criteria:The ceiling should be installed neatly with all joints aligned.Entire area to be covered completely as per design layout.The job shall be considered complete only after approval from EIC. |
| 6 | Providing and fixing 12 mm thick pre-laminated particle board, flat pressed, three-layer or graded wood particle board conforming to IS: 12823, Grade I, Type II, in paneling, fixed within aluminium partition frames using C.P. brass / stainless steel screws, etc.The pre-laminated particle board shall have decorative lamination on both sides.All work shall be completed in accordance with the specifications and as per the direction of the Engineer-in-Charge. |
| 7 | Providing and fixing 12 mm thick pre-laminated particle board, flat pressed, three-layer or graded wood particle board conforming to IS: 12823, Grade I, Type II, in paneling, fixed within aluminium partition frames using C.P. brass / stainless steel screws, etc.The pre-laminated particle board shall have decorative lamination on both sides.All work shall be completed in accordance with the specifications and as per the direction of the Engineer-in-Charge. |
| 8 | Providing and fixing aluminium work for partitions using extruded, built-up standard tubular sections / appropriate Z-sections and other sections of approved make, conforming to IS: 733 and IS: 1285. The sections shall be fixed with dash fasteners of required diameter and size.The work shall include:Filling all gaps at junctions (top, bottom, and sides) using suitable EPDM rubber / neoprene gasketsEnsuring aluminium sections are smooth, rust-free, straight, mitred, and mechanically jointed wherever required Provision of cleat angles, aluminium snap beading for glazing/panelling, and use of C.P. brass / stainless steel screws as necessary.The entire job shall be completed in all respects as per the direction of the Engineer-in-Charge. |
| 9 | I HAVE FULLY UNDERSTOOD THE SCOPE OF WORK & AGREE TO ABIDE BY GENERAL CONDITION OF CONTRACTNAME, SIGNATURE & ADDRESS OF THE CONTRACTOR WITH SEAL |