}

Tender For Miscellaneous Electrical Works At Datia Airport., bhopal-Madhya Pradesh

Tender Notice

51840455
Tender For Miscellaneous Electrical Works At Datia Airport.
Tender
Indian
Madhya Pradesh
Bhopal
06-11-2025

Tender Details

Tender For Miscellaneous Electrical Works At Datia Airport.; 1 Design, Supply, Installation, Testing and Commissioning of FAA compliant, indoor type Micro- processor based Constant Current Regulator(CCR) suitable for remote as well as local control operations with 5 position brightness control (6.6A maximum current corresponding to 100% brightness) on input voltage 230/415 V, 50 Hz., AC supply, provision for control supply with all switchgears, CCR protections, connection/ inter-connections etc. and confirming to tenders technical specifications complete as required.a) 4 KW, 6. 6A output current. 2 Supply of single core x 6 sq. mm sizes 5 KV grade PVC insulated & PVC sheathed, antitermite & anti- rodent,multi-strandedcopperconductorsinglecoreairfieldlightingcableconfirmingtoIS 1554 (Part II) with up to date amendments complete as required. 3 Supply of 4 core x 25 Sqmm. XLPE insulated PVC sheathed armoured aluminium conductor cable of 1.1 KV Grade confirming to IS:7098 (Part 1) with upto date amendment etc. complete as required. 4 Supply of 3 core x 16 Sqmm. XLPE insulated PVC sheathed armoured aluminium conductor cable of 1.1 KV Grade confirming to IS:7098 (Part 1) with upto date amendment etc. complete as required. 5 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) 6 Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 5 KV grade of 6 sqmm size in the existing RCC/GV/ DWC HUME/ METAL pipe etc. as required. 7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 8 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Up to 35 sqmm 9 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Up to 35 sqmm 10 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Up to 35 sqmm 11 Supply of 5 KV grade plug and receptacle ,suitable for field attachment with 5 KV grade PVC insulated, PVC sheathed single core 6 sq. mm copper conductor AGL cable complete etc. as required. 12 Making connections of 5 KV grade, 6 Sq. mm Copper conductor AFL cables withplug and receptacle connector i/c crimping & fixing, applying HT tape complete as required. 13 SITC of Mini Remote Control Desk havingprovision for control of PAPI both side landing T and windsock and 1 CCR spare i/c MIMIC display etc. complete as required. 14 Supply and fixing of 24 core X 1.5 Sq. mm Copper conductor armoured 1.1 KV grade XLPE insulated PVC Sheathed control cable as per IS 7098 Part-1 1988 as amended upto date as per site requirement. 15 Supply, Erection and termination CRCA sheet 3mm powder coated control cable end termination junction box to be mounted on wall 300mm X 200 mm X 500mm 16 Earthing with G. I. pipe 4.5 m long x 40 mm dia. (Drilling of 300 mm dia, 4.5 Mtr deep by using Borewell machine) including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. includingcharcoal or coke and salt complete as required. 17 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 18 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections complete etc. as required. 19 Supplying and fixing following DB- Phase Segregated DB 12 Way Double Door 8 Incomer 4+4+4 Sub Incomer 12+12+12 Outgoing, of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted, IP54 including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 20 Supplying and fixing distribution board of 12way double door SP, steel sheet for 230 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 21 Supplying and fixing 63 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A TPN MCB 22 Supplying and fixing 32 amps rating, 240/415 volts, C curve, Double Pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 23 Supplying and fixing following rating, two pole,230 volts, residual current circuit breaker (RCCB), having a sensitivity current30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A 24 Supplying and fixing 6 amps rating, 240volts,10kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 25 Supplying and fixing 16 amps rating, 240volts,10kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 26 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 27 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 28 Wiring for circuit/ sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 29 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 1 no. 5 pin 5/6 A & 1 no. twin 6/16 A modular socket outlet and 1 no. 5/6 A & 1 no. 15/16 A modular switch, connections etc. as required. 30 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 no. 5 pin 5/6 Amodular socket outlet and 2 no. 5/6 Amodular switch, connections etc. as required. 31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 1 no. twin 6/16 A modular socket outlet and 1 no. 15/16 A modular switch, connections etc. as required. 32 Supply of energy efficient 5 star rated BLDC ceiling fan, 1200 mm sweep remote operated suitable for operation on 240V, 50Hz A.C. supply with down rod canopies etc. complete as required. (Maximum power consumption - 28W) 33 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 34 Supply of energy efficient wall fan Hiflo Wave Plus 60W KD White Wall Fan Sweep: 400 mm suitable for operation on 240V, 50Hz A.C, complete as required. (Maximum power consumption - 60W) 35 Installation, testing and commissioning of wall mount fan, including wiring with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. complete as required. 36 Supply of 230 mm sweep metallic exhaust fan suitable for operation on 240V, 50Hz A.C. supply, 1400 rpm with all accessories including louvers, shutters etc. complete as required. 37 Installation of exhaust fan of size 230 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 38 Supply of minimum 15 Watt recessed mounting LED downlight with minimum output 1500 lumens suitable for 140-270 V, AC, 50 HZ, PF>0.95, luminaire should have extruded aluminium / CRCA / Extended alloy housing. Luminaire should have proper thermal management, Min IP protection should be IP 20. Total power consumption of fitting (including driver loss) should not more than 110 % of rated capacity of LED Light fitting, complete with all accessories as required. 39 Supply of minimum 30 W LED recessed 2ft X 2ft luminaire with minimum output 3000 lumens suitable for 140-270 V, AC, 50 HZ, PF>0.95, luminaire should have extruded aluminium / CRCA / Extended alloy housing. Luminaire should have proper thermal management, Min IP protection should be IP 20. Total power consumption of fitting (including driver loss) should not more than 110 % of rated capacity of LED Light fitting, complete with all accessories as required. 40 Supply of minimun 40 W LED street light fitting with minimum output of 4400 lumens suitable for 140-270 V, AC, 50 HZ, PF>0.95, luminaire should have High pressure die cast Aluminium /Standard alloy housing. Luminaire should have Air vents in housing for proper thermal management, Min IP protection should be IP 65. Total power consumption of fitting (including driver loss) should not more than 110 % of rated capacity of LED Light fitting, complete with all accessories as required. 41 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent / LED Fittings of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 42 Supply, Installation, Testing & Commissioning of 2 Ton (5 Star) Inverter Split Air conditioning unit fittedwith rotary compressor alongwith indoor/outdoor units, gas R-410A or eco-friendly gassuitable to operate on 230V +/- 10%, 50 Hz, single phase AC power supply capable of performing the function as Dehumidification, air circulating and filtering complete with compressor, evaporators, air cooled copper condenser connected refrigerant piping (upto 10 feet) electrical wiring including MS stand suitable for outdoor unit with all accessories complete etc as required. 43 Supply, Installation, Testing & Commissioning of 1.5 Ton (5 Star) Inverter Split Air conditioning unit fittedwith rotary compressor alongwith indoor/outdoor units, gas R-410A or eco-friendly gassuitable to operate on 230V +/- 10%, 50 Hz, single phase AC power supply capable of performing the function as Dehumidification, air circulating and filtering complete with compressor, evaporators, air cooled copper condenserconnected refrigerant piping (upto 10 feet) electrical wiring including MS stand suitable for outdoor unit with all accessories complete etc as required. 44 SITC of Floor Standing RO Purifier Chiller & Dispenser having RO + UF + TDS Control with minimum Flow Rate 30L/hr and storage 20L Tank complete as required 45 SITC of 1.5kVA stand-alone solar power system having 3no. 530Wp monocrystalline solar panel,1no. 24V 1.5kVA solar inverter with MPPT feature, 2no. 150Ah solar tubular batteries, complete with DCDB box, earthing, Lightning arrestor installation and module mounting structure and associated all cabling complete etc. as required.Preferred make-TATA POWER or equivalent. 46 Supply of 3 core x 4 Sqmm. XLPE insulated PVC sheathed armoured copper conductor cable of 1.1 KV Grade confirming to IS:7098 (Part 1) with upto date amendment etc. complete as required. 47 Supply, Installation, Testing and Commissioning of following 5 H.P. 3 Phase 100 mm water cooled Borewell Submersible pump set- with associate accessories. 48 Supply, Installation, Testing and Commissioning of following 5 H.P. 3 Phase 6-10A DOL water cooled Borewell Submersible Pump Starter with associate accessories. 49 Supply, Installation, Testing and Commissioning of following sizes of CI butterfly valve conforming to API-594 with C.I. body, SS Disc, SS stem, EPDM seal, complete with companion flanges, bolts, nuts, washers & inserted rubber gasket complete as required 50 150 mm dia. 51 100 mm dia. 52 80 mm dia. 53 Supply, Installation, Testing and Commissioning of following sizes of C- class heavy duty Mild Steel pipes conforming toIS-1239/ IS-3589, including cutting, welding, nut-bolts, gasket, fitting viz. bends, tees, reducers, crosses, flanges etc. and fixing the pipes onwall / ceiling / beam / floor with suitable MS clamps / structural supports/PCC block and painting complete as required and as per enclosed specification. 54 150 mm dia. 55 100 mm dia. 56 80 mm dia. 57 Supply, Installation, Testing and Commissioning of MS structural support for Above ground piping and pump room manifold 58 Supply of fracture bed designed to provide firm, even support for patients with fractures. Bed to be made of mild steel with a powder-coated finish having features for allowing for changes in height and position and includes wheels for easy mobility within the hospital setting 59 Supply of healthcare semi fowler bedmade of mild steel with a powder-coated finish having feature to bend bed from mid. 60 Supply of suitable semi fowler 2 section mattress for healthcare bed with minimum 4inch thickness. The mattress to have non hygroscopic outer cover which is easy to clean such as artificial leather cover.

Key Value

Document Fees
INR 1120 /-
EMD
INR 171254.0 /-
Tender Value
INR 57.08 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail