Tender For Additional / Alternator Of Bldg No. T-98 At Hq Cif(R) Under Age(I) Cif(R); 1 Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed. 2 S&F Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified. 3 S&F Prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified. 4 S & F rolled mild steel work in tubular trusses, vertical posts, rafters, purlins etc. including special shaped etc complete using ERW or induction butt welded tubes conforming to Gde St-240 and painted one shop coat of zinc chromate primer paint (including preparation of surface) at contractors workshop before fabricationcomplete all as specified and directed. 5 S & F mild steel work as in wind ties for roof including all necessary drilling, bolting or riveting, etc.,and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed. 6 Preparation of new steel surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel painting over a coat of red oxide primer complete all as specified and as directed by Engr-in-charge. 7 Excavation in post holes (or similar holes) in any type of soil, each not exc 0.50 cum, getting out, removing surplus spoil to distance not exceeding 50 mtr and making good surface complete all as specified and as directed. 8 Cutting holes into or through brick walls in cement mortar superficial area not exceeding 150 Sqcm but not exc 400 Sq.cm and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 using 20mm graded aggregate as required complete, all as specified . 9 Demolition of cement concrete ( unreinforced) in ground floors and pavings n exe 15 cm thickness. ( below or above ground level) all as specified. 10 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as directed. 11 25mm thick PCC (1:2:4) type B-0(using 12.5mm graded stone aggregate) as in sub base for laying floor finishes complete all as specified and directed. 12 M&L for screed bed or bedding layer of mortar 15mm thick in cement mortar 1:4 laying floor finishes complete all as specified. 13 M&L for light shade Vitrified tiles 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of existing surfaces.(Note:The contractor shall have no claim on difference what so ever on shade /colour of tile) 14 All as per item No.13 here-in-before but on vertical surfaces as in skirting including 8-10 mm thick rendering as backing coat to receive the tiles on fair faces of brick /concrete surfacesin cement mortar 1:3 and finishedeven and rough complete all as specified and directed. 15 M&L for makrana white marble 20 mm thick machine cut, bedded jointed and pointed with white cement slurry including cutting and polishing types complete all as specified. 16 Green/Black granite on shelves 18 to 20 mm thick set jointed with 3.00 kg per sqm neat cement slurry and pointed with coloured cement to match the surface complete all as specified and directed. 17 M&L for screed bed or bedding layer of mortar 20mm thick in cement mortar 1:4 laying floor finishes complete all as specified. 18 PCC 50 mm thick type C-1 1:3:6 (using 20 mm graded crushed stone aggregate) as in plinth protection laid in alternate pannels finished even and smooth without using extra cement complete all as specified and directed. 19 M&L PCC 1:2:4 type B-1 using 20mm graded aggregate as in coping/benching complete all as specified and directed. 20 Glazed ceramic tiles in vertical surface 450 x 300 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface rendering as backing coat to receive the tiles on fair faces of brick /concrete surfacesin 10 mm thick cement mortar 1:3 and finishedeven and rough complete all as specified and directed. 21 Taking down cement plaster on brick wallor concretesurfaces of ceilling etc incl racking out joints hacking for key scrubbing down with water etc. complete allas specified & directed. 22 M&L for Rendering 15mm thick (in two layer 10+5)on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement including mixing integral water proofing compound in the proportion as mentioned in manufacturers instructions. (Water proofing compound to be measured and paid for separately). 23 M&L for Rendering 10mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete allas specified & directed. 24 Supply only integral water proofing compound complete all as specified. 25 Preparation of new plastered surfaces of wall and applying two coat of Oil bound distemper including primer over a coat of 1mm thick birla white putty complete all as specified. 26 M&L forpreparation ofnewl surfaces for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. 27 M & L brick work with sub class B bricks, straight or curved on plan exc. 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed. 28 M & L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as foundation filling and mass concreate, complete all as specified and directed. 29 Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the samethe necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & inless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. 30 M & L 10 mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required. 31 Excavation in trenches, in any type of soil not exc 1.5 mtr wide and not exc 1.5 m in depth for foundation, etc or not exceeding 10sqm on plan and not exceeding 1.5m in depth for pole, shafts, cesspits, manholes, pier holes, etc. and getting out of any type ofsoil for laying UG cables of various sizes complete all as specified and directed. 32 Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm in any type of soil complete all as specified and directed. 33 Removing surplus spoil to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.50m from the starting point., all as specified . 34 M & L for PCC 1:3:6, Type- C-2 (using 40mm graded crushed stone aggregate) as in surface channels & drains including necessary moulds/form work, complete all as specified and directed. 35 M&L for Point wiring complete with 1.5 Sqmm single core multi stranded copper conductor cable PVC insulated unsheathed cable 1100 volt grade enclosed and including PVC casing and capping with fittings and accessories fixed to walls/ceiling by means of PVC rowl plugs fasteners with cadmium plated screws all as per IS including hard wood board and 3mm thick laminated sheet top covers including 1 Sqmm copper PVC insulated unsheathed continuous earth wire and connected to common earth dolly for the following:- 36 (a) One light/fan/5 Amp socket independent/bell controlled by one, one way switch. 37 (b)For one three pin socket outlet 5 Amps independent board complete 38 (c) One 3 pin 5 Amp socket out let on the same board with other switches. 39 All as per item No. 35 above but with 2.5 Sqmm copper cable for 3 pin 15 Amps socket outlet on independent board, including 2.5 Sqmm PVC insulated unsheathed continuous earth wire and connecting to common earth dolly. 40 Supply and fixing of modular switch single pole one way6 Amps 1 module complete all as specified and directed 41 Supply and fixing ofmodularsocket 6 A-2/3 pin combined 2 module complete all as specified and directed. 42 Supply and fixing of modular switch single pole one way 16 Amps 1 module complete all as specified and directed 43 Supply and fixing of modularsocket 6 A/16 amp -2/3 pin combined 2 module complete all as specified and directed. 44 Supply and fixing of ceiling rose 65X50 mm two to three terminals complete all as specified. 45 Supply and Fixing of Fan step regulator, 120W - 2 module complete all as specified and as directed. 46 Supply and fixing round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete complete all as specified and directed. 47 Supply and fixing of sheet metal enclosureMCB distribution board SPN 12 way240 V, 50 Hz double doorwith neutral, Earthing bar and din rail, complete all as specified and directed. 48 Supply and fixing of sheet metal enclosureMCB distribution board SPN 8 way240 V, 50 Hz double doorwith neutral, Earthing bar and din rail, complete all as specified and directed. 49 Supply and fixing of MCB single pole 6 to 30 Amps, 10KA, 230 volts C series, complete all as specified and directed. 50 Supply and fixing of MCB SPN 40 to 63 Amps, 10KA, 230 volts C series, complete all as specified and directed. 51 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq mm 2 core. complete all as specified and directed. 52 M&L for two single core sub main wiring6.0 Sqmm multi-strand PVC insulated copper conductor FRLSH cable including PVC insulated copper conductor cable of size 6.0 Sqmm as cotinuous earth wireconnecting to common earth including in 20mm PVC rigid conduitincluding connections of cable with MCBs or bus barscomplete all as specified and directed. (Note:2x6 + 1x6.00 sqmm copper coductor with PVC Conduit shall be measured as one unit) 53 M&L for two single core sub main wiring2.5 Sqmm multi-strand PVC insulated copper conductor FRLSH cable including PVC insulated copper conductor cable of size 2.5 Sqmm as cotinuous earth wireconnecting to common earth including in 20mm PVC rigid conduitincluding connections of cable with MCBs or bus barscomplete all as specified and directed. (Note:2x2.5 + 1x 2.5.00 sqmm copper coductor with PVC Conduit shall be measured as one unit) 54 Supply and fixingof 1.5 Sqmm three core multi stranded copper conductor (FRLSH) cable PVC insulated unsheathed cable 1100 volt grade conformingto IS-694:2010 complete all as specified and directed. 55 Supply and fixing LED light fitting with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lampincluding connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 56 S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 57 Supply & Fix LED bollard light 10 Watt, warm white, single phase, 220 Volts made of ceramic body material, base plate type mounted on PCC Square duly screwed all as specified and directed. Make -Orient, Note :- Cost of PCC work 1:3:6 (20 mm) in square shape (.303x.303x.303 mtr ) for mounting of Lights incl with Item cost. 58 Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant ncomplete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. 59 M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4.0 mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frame 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipeincluding excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I.complete all as specified and directed. 60 M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed. 61 Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge. 62 M&L for GI pipe 40 mm dia light grade ISI marked, laid in trenches/ on floors/on, pole/road for cable protection including necessary joints / fittings complete all as specified and directed . 63 Deduction to be made from BOQ for schedule of credit (Sch A Part - II) Amount of ₹ 24,800.00during AOCNote:- Tenderers shall not quote for this Schedule