}

Tender For Special Repair Of Otm Accommodation Bldg. No. Ht-28 & Ht-29 Or Line And Rewiring Ofad Regt Under Age B/R-Ii Under Ge (North) Ambala Cantt., ambala-Haryana

Tender Notice

51837410
Tender For Special Repair Of Otm Accommodation Bldg. No. Ht-28 & Ht-29 Or Line And Rewiring Ofad Regt Under Age B/R-Ii Under Ge (North) Ambala Cantt.
Tender
Indian
Haryana
Ambala
06-11-2025

Tender Details

Tender For Special Repair Of Otm Accommodation Bldg. No. Ht-28 & Ht-29 Or Line And Rewiring Ofad Regt Under Age B/R-Ii Under Ge (North) Ambala Cantt.; 1 Schedule A Part-I (B/R itmes)Dismantlingof plain or corrugated steel sheeting, any gauge, thickness, incuding nainital or similar pattern roof coverings, complete all as specified and as directed. 2 Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges, complete all as specified and as directed. 3 Dismantling of timberscantlings 40 sq cm and over in section, in any position, unframed work , complete all as specified and as directed. 4 Dismantling of brick work built in cement mortar or cement lime mortar including all quoins, arches,pillar, etc. but excluding ashlar facing, dressed stone work and precast concrete articles , complete all as specified and as directed. 5 Material and labour for brick work with sub class B old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6), complete all as specified and as directed. 6 Supply andFixingmild steel work as in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240, complete all as specified and as directed. 7 Supply andFixing pre–painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick, having zinc coating 150 gm per sqm (Az–150) of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws,complete all as specified and as directed. 8 Supply andFixing pre–painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, having zinc coating 150 gm per sqm (Az–150) as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed. 9 Dismantling of boarding or false ceilingof any description and in any position of any size, complete all as specified and as directed. 10 Supply and fixing of GIMetal Suspended ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, and as directed by Engineer-in-charge. GI Metal Ceiling laying perforated Tengular edge global white colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece. Note- Ceiling tiles and ceiling grid shall be of the same make. 11 Demolition of cement concrete (un–reinforced) in ground floors and pavings not exe 15 cm thickness (below or above ground level) , complete all as specified and as directed. 12 Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed. 13 Material and labour for 75mm thick PCC 1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate) as in sub base to floor /hardstanding etc finished even to receive floor topping etc.,complete all as specified and as directed. 14 Material and labour for vitrified ceramictiles, double charged , premium /first quality,(square/ rectangular), 09 to 10mm thick, area of each tile exceeding 0.36 sqm andnot exc 0.42 sqm as in floor, set and jointed in neat cement slurry and pointed in colouredcement to match the surface over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6for laying floor finishes, complete all as specified and as directed. 15 Material and labour for vitrified ceramic double charged tiles, premium /first quality, of same description as of floor tiles in serial item No.14abovebut 100mm to 150mm heightas in skirting, set and jointed in neat cement slurry and pointed in colouredcement to match the surface, over and including rendering 10 mm thick in cement mortar 1:4, complete, all as specified and as directed. 16 Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key scrubbing down with water, etc., complete all as specified and as directed. 17 Material and labour for rough cast plaster complete as specified in SSR Part-I, clause 14.22 shall consisting of following:- firstly apply under coat in cement mortar 1:4 not less than 10 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine stone aggregate of size between 6 to 12 mm as per the texture required mixed with coarse sand and cement in the ratio 1:1:1 shall be applied, complete all as specified and as directed. 18 Material and labour for rendering 15mm thick in cement mortar plaster (1:6) on any faces of brick work or concrete wall surfaces and finished even and smooth without using extra cement up to height of double storey bldg, including necessary scaffolding etc, complete all as specified and as directed. 19 Material and labour for preparation of newly plastered/ unplastered surfaces of walls and applying two coats of acrylic distemperwith painting roller over and including 1 to 2 mm thick wall care putty white cement based in one or two coats to achieve smooth surfaces, complete all as specified and as directed. 20 Material and labour for preparation of old decorated brick/concrete, plastered / unplastered surfaces of walls,by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots andapplying onecoat of acrylic distemperwith painting roller over prepared surfaces, complete all as specified and as directed. 21 Material and labour for preparation of old decorated brick/concrete, plastered / unplastered surfaces of ceilingby brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots andapplying one coat of cement based paint onprepared surfaces ofceilingetc. , complete all as specified and as directed. 22 Material and labour preparation of old decorated brick/concrete, plastered / unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots andapplying one coat ofcement base paint on the wall, pillars, cornices etc , complete all as specified and as directed. 23 Material and labour forpreparation of new steel surfacesof any description, not otherwise described, over10 cm width or girth and applying two coats of synthetic enamel paintover a coat of red oxide primer, complete, all as specified and as directed. 24 Taking down chowkats or frames with shutterareanot exceeding 1.50 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish, complete all as specified and as directed. 25 Taking down chowkats or frames with shutterarea exceeding 1.50 Square meter andnot exceeding 4.00 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish, complete, all as specified and as directed. 26 Material and labour for rolled mild steel framed work as in chowkats ofdoor or gates of angle or other section with gusset plates, rails braces etc. complete. drilled for fixing for steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges and hanging ,door fitting (exclusive of steel sheeting or other covering, running rails and guides) also fastening and fixingconforming to Fe-290-W (Gde E-165) quality A complete all as specified and as directed. 27 Material and labour forPCC 1:3:6 type C1 using 20mm graded crushed stone aggregate as in holdfasts etc.,complete all as specified and as directed. 28 Material and labour for factory made 2nd class hard wood 35 mm thick plain framed panelled shutter( two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both face . The size of rail and style as per IS:1003 (Part-1) kiln seasoned and chemically pressure treated ,complete, all as specified and as directed. 29 Material and labour for factory made 35 mm thick 2nd class hard wood glazed and skeletonshutters,open rebated and prepared to receive glass , gauze etc. (without sash bars) ,edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I, Section-8, clause 8.24 (a) (wood shall be kiln seasoned and chemically pressure treated) complete all as specified and as directed. 30 Material and labour for preparation of new woodensurfacesof any description, not otherwise described, over10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete, all as specified and as directed. 31 Supply andFixing double shutter steel window box type ERW hollow P section comprising of glazed and gauged skeleton shutterfabricated fromfollowing sections :-(a) ERW hollow P section frame of size 60 mm x25 mm made from 1.25 mm thick MS sheet (02 Nos i.e. 01 for glazed shutter and 01 for gauzed shutter ). Both P section shall be welded with flat iron 25x03 mm thick all around of frame on both inner and outer faces . (b) Style and rails of window shutters shall be fabricated with ERW hollow P section of size 50 mm x25 mm made from 1.00 mm thick MS sheet and comprising of 02 Nos sash bars for glazed window leafof T – section20 x 03 mm thick and one No sash bar of 20 mm x 3 mm thick section for gauzed winodw leaf .(c) Vertical mullion shall be ERW hollow T -section of size 60 x 25 mmmade from 1.25 mm thickMS sheet (d) The above steel window shall be deemed to include the following accessories/ fittings : i)Hold fast 150mm long mild steel flat iron 12x3 mm thick made to shape- 04 Nos per window ii)Handle of Z section 20mmx25mm, 100mm long – 01 No per leaf.iii) MS tower bolt stove enamelled150mm long- 2 Nos per leaf. iv) Z section 20mmx25mm, 100mm long stopper – 01 No per leaf. (v) Cleat 55 mm long of solid square 15x20x.63mm square - 01 No per leaf vi)Pintal hinges 12 x 75 mm- 2 Nos each leaf vii) 10mm square Guard bar @ 10 cm c/c welded to frame .(viii) Two coat of Synthetic enamel paint over one coat ofred oxide primer.(ix) 0.36mm nominal dia of stainless steel wire mesh and average width of aperture of 1.40mm fixed in gauzed skelton shutter ofwindow with flat iron 15 x 03 mm with steel screws .(x) 3mm thick sheet glass, ordinary quality and with oil putty in square n. exc 0.5sqm in each pane fixed in glass shutter of window.(xi) Fabrication and fixing arrangements as per specification including cutting holes and making good dismantled portion in PCC 1:2:4 type B-1 /cement plaster 1:4 as require and make finish good to the existing surface complete all as specified and directed.Notes : (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frames shall be considered as one unit.(ii) Unit rate quoted against this item shall also include the iron mongery, grill and other accessoriries as mentioned above.(iii) The window upto1.00 metre width shall consists of two leaves both for gauzed shutter and glazed shutter and all the shutters are openable.The window more than 1.00 metrewidth shall have two openable leaves onboth outer sidefor gauzed shutter and glazed shutter and middle leaf/shutter shall be fixed type. 32 Supply and fixing of 150 mm long aluminium handle, cast type, anodised, complete, all as specified and as directed. 33 Supply and fixing of 200 mm long, aluminium anodised, barrel tower boltsof extruded section , complete, all as specified and as directed. 34 Supply and fixing of 250mm long aluminium alloy, anodized, sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloys to door shutter ,complete, all as specified and as directed. 35 Supply and fixing of butt hinges 100mm long of stainless steel, medium weight, complete, all as specified and as directed. 36 Supply andFixing stainlesssteel curtain rod 25mm dia having wall thickness 1.00mmfixed with and including stainless steeldecorative brackets, two lotto for each rod length at both endetcas in repair complete, all as specified and as directed. 37 Supply and fixing ofstainless steel wire cloths0.36 mm nominal dia of wire and averagewidth of aperture 1.40 mm and fixed with stainless steel wire staple, complete, all as specified and as directed. 38 M & L providing 75 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternatebays (not exc 2 Sqm each )and finished even and smooth without using extra cement and providing jointsthroughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work, complete, all as specified and as directed. 39 Schedule A Part-II (E/M itmes)Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc.,complete, all as specified and as directed. 40 Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly(boxesshall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally) including provision of new covered plate over sunken box for housing themodular switches , modular socket outlets,modularfan regulators etc.for one light/fan/exhaust fan/bell point controlledby one way switch,complete all as specified and as directedby Engineer-in-Charge. Note :-a) All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid forseparately . 41 Description all as per serial item No.40 here-in-before but for One 3 pin, 6 Amps, socket outlet controlled by one switch on independent board,complete all as specified and as directed. 42 Description all as per serial item No.40 here-in-before but for One 3 pin 6 Amps socket outlet controlled by one switch on same board,complete all as specified and as directed. 43 Description all as per serial item No.40 here-in-before but for one socket outlet 16 Amp with 2.50 sq mm PVC insulated, unsheathedcable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.50 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade, ISI marked with multi stranded copperwire as earth continuity conductor connected to common earth dolly complete all as specified and as directed. 44 Supply and fixing of modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts, complete all as specified and as directed. 45 Supply and fixing of modular switch 1 module, single pole, one way 16 Amps flush type, 230 voltscomplete all as specified and as directed. 46 Supply and fixing of modular socket outletmultipin combined,6 Amp, one way, two module, 230 voltscomplete all as specified and as directed. 47 Supply and fixing ofmodular socket outletmultipin combined, (6pin), 16 Amps, one way, two module, 230 voltscomplete all as specified and as directed. 48 Supply and fixing ceiling rose surface type 2/3 terminalpolycarbonate, isolated body complete all as specified and as directed. 49 Supplyand fixingas in repairelectronic Fan regulator, modular 100 watts, 2 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep, complete, all as specified and as directed. 50 Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed . 51 Supply and fixing in repairLED batten fitting 20 watt, 4 feet, polycarbonate housing with electronic drivercool/warm type, connecting with copper conductor flexible cablefrom ceiling rose to connector of the light complete all as specified and as directed. Cat part No. LBLN-20-C-SQ of make Orient or equivalent in make given in Appx B. 52 Supply and fixing in repair,LED Bldg Security Light Fittings of capacity 40-45 watt made up of die castaluminiumhousing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including electronic driver and making electrical connection, complete all as specified and as directed.Cat part No.LSFS-45-CF-PC of make Orient orHLSLD-14-40-CWDL-R01 of make Halonix or equivalentin make given in Appx B. 53 S & laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI markedmulti stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and includingPVC conduit medium gradeISI marked of adequate size for housing the wires complete all as specified and as directed.Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.(ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length. 54 Supply and fixing MCB SPN 32 Amps, 240 volt,10 KA ,B curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.Cat part No 811034 of make Indoasian or equivalent make given in Appx B. 55 Supply and fixing MCB SP, 6-32 Amps, 240 volt,10 KA ,B curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge. Cat part No 811008 to 811015 of make Indoasian or equivalent make given in Appx B. 56 Supply and fix sheet metal enclosureVertical triple pole & neutral(VTPN) IP-43 suitable for MCCB 125 Amp & including MCCB 125Amp, 16 KA, 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and includinglugs/thimbles duly crimped for connectionincluding making smooth the disturbed surface including removing old unserviceable enclosure complete all as specified and as directed . Cat part No.811888 of make Indo Asian or equivalentin make given in Appx B. 57 Supply and fix sheet metal MCB DB SPN12 way with 200 Amps rated bus bar single pole and neutral withdouble door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed. Cat part No.811808 of make Indo Asian or equivalentin make given in Appx B. 58 Material & labourfor earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earthstrip 25 x 3 mm thickby means of bolts, nuts, check nuts and washers of galvanised iron.Earth stripprotected by GI pipe 32mm bore(medium grade) and connected to earthing test pointas directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/cboth ways with one handle for liftingmade out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testingas in repair complete all as directed by Engineer-in-Charge and earth testing on completion . 59 Supply and laying in trenchesservice cable 35 Sqmm 3.5 Core XLPEinsulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power 1100 Volts grade with stranded aluminium conductor complete all as specified and directed. 60 Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for foundation etc for laying of cables etc. or for shafts, wells, manholes etc. not exc 10 sqm on plan and not exc 1.5 m in depth and getting out in soft/ loose soil, complete all as specified and as directed. 61 Returning filling in including spreading, levelling, watering and wall ramming in layer n exc not exc 25 cm, any kind of soil complete all as specified and directed. 62 Removing surplus excavated materialto a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point ,complete all as specified and as directed. 63 Supply and laying well burnt brick class-B laid flat to cover the cable width equal to the length of cable and abutting each other for protection of cablecomplete all as specified and as directed. 64 Material and labour drysand cushoning to cable i.e 8 cm before laying cable in trenches and 15 cm after laying the cable and compactingcomplete all as specified and as directed. Note: punned thickness shall be measured for payment. 65 Supply andFixing as in repairlight grade GI Tubing of size 40mm dia for cable protection and fixed with clamp to pole and wall with nut, bolts, washers complete all as specified and as directed. 66 Supply and fixing GIfan rod 1 metre long and 15mm dia heavy duty withsuperior quality and nut and bolts with locking arrangement including connection from ceiling rose to ceiling fan and refixing the ceiling fan ,complete all as specified and as directed. 67 Note:-Amount of credit ofRs.1,20,640.00for retrieved materials is mentioned in Schedule of Credit Page No. 124. of tender documents in pdf form which will be deducted offline while acceptance of tender.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 39.08 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail