}

Tender For Provision Of Deficient Md Accommodation For Dsc At Borgad Under Ge (Af) Ojhar., Nashik-Maharashtra

Tender Notice

51837227
Tender For Provision Of Deficient Md Accommodation For Dsc At Borgad Under Ge (Af) Ojhar.
Tender
Indian
Maharashtra
Nashik
21-11-2025

Tender Details

Tender For Provision Of Deficient Md Accommodation For Dsc At Borgad Under Ge (Af) Ojhar.; 10 SCH A PART XI (MISC B/R & E/M ITEMS) Note:- Excavation and earthwork to the extent required for execution of relevant item under this schedule unless otherwise specified shall be measured and paid under relevant items of Schedule A Part-II. 11 INTERNAL WATER SUPPLY 12 Supply and fixing Health Faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia fixing in pipe with 1.25 meter long flexible tube and ABS wall hook including making connection and fixed to 15 mm bore complete all as specified and as directed. 13 Supply and fixingangle valve of cast coper alloy chromium plated fancy type screwed down high pressure with crutchor butterfly handle screwed both ends for cpvc pipe or for unions and fixed to 15 mm diabore (concealed) complete all as specified and directed. 14 Supply and fixing 15mm dia. size Two way Bib taps, fancy type,,cast copper alloy with crutch or butterfly handle screwed down for CPVC pipe or for brass ferrule and fixed complete all as specified and as directed. 15 Supply and fixingBrass CP Mixer for mixing hot & cold water screwed down for CPVC Pipe of 15 mm dia bore and fixed all as specified and as directed. 16 INTERNAL ELECTRIFICATION 17 Supply and fixing switch modular type,2 module, 20 A DP Switch with indicator230 volts one way complete all as specified and directed.( For Acs) 18 Supply and fixenergy efficient LED lamp 5 watt capacity complete all as specified and directed 19 Supply and fixing energy efficient 20 watt (4.0 feet)LEDintegrated batten type luminairessuitable for wall or ceiling mounting with built in LED Chip & integral LED driver 20 watt,Aluminiumchannel housing & Polycarbonate diffuser of length 1200 mm (approx.),Color temperature 6500 K or as directed, CRI between 80-85,Low THD,PF-0.90(mimium),efficacy not less than 100 lumen/watt or total lumen output not less than 2000 lumen per 20 watt, operating range 200-270V ,surge protection of 2 kV,over voltage protection and other safety tests as per IS 15885 Part-2/Part-3,estimated life span of 25,000 hrs with all accessories, complete with fixing arrangement, fitting shall be internally prewired and conforming to LM 79 & LM 80 standard, making all connection using 1.5 sqmm copper conductor multistrand PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through PVC flexible conduit complete fixed in position & connecting complete all as specified and directed by Engr–in-charge.Note: (i) LED fitting shall be provided for 3 years warranty. (ii) Location for Installation of LED fitting shall be as per approved drawing) 20 Supply and fixing energy efficient 10/12 watt (2.0 feet)LEDintegrated batten type luminairessuitable for wall or ceiling mounting with built in LED Chip & integral LED driver 10/12 watt,Aluminiumchannel housing & Polycarbonate diffuser of length 600 mm (approx.),Color temperature 6500 K or as directed,efficacy not less than 100 lumen/watt or total lumen output not less than 1000 lumen per 10 watt, operating range 200-270V ,surge protection of 2 kV,estimated life span of 25,000 hrs with all accessories, complete with fixing arrangement, fitting shall be internally prewired and conforming to LM 79 & LM 80 standard, making all connection using 1.5 sqmm copper conductor multistrand PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through PVC flexible conduit complete fixed in position & connecting complete all as specified and directed by Engr–in-charge. Note:(i) LED fitting shall be provided for 3 years warranty. (ii) Location for Installation of LED fitting shall be as per approved drawing. 21 Supply and fixing LED Bulk Headtype with high out put , 10 watt ,220 V AC,Color temperature 6500 K or as directed,or as directed,efficacy not less than 100 lumen/watt or total lumen output not less than 1000 lumen/10 watt, estimated life span of 50,000 hrs with all accessories, complete with fixing arrangement, fitting shall be internally prewired and conforming to LM 79 & LM 80 standard ,IP 65 protection dust and water resistant ,surge protection up to 2.5kV, PC opal high efficiency diffuser , die cast aluminium housing with complete assembly, suitable for surface/wall mountedwith driver holder including connecting up using 1.5 sqmm copper conductor multistarnd PVC insulated with three core flexible copper conductor cable of suitable sizecomplete all as specified and directed. 22 Supply and Fix distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with appropriate Amps rated copper busbar, neutral bar,internalearth bar and cable ties for cable management,reversible door forIP 43 & IP 54,IK 09 impact resistance, single pole and neutral 250 Volts, flush to wall including chasescutting in wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.DB shall be designed with provision for MCB SPN as incomer &MCB SP as outgoing as per requirement. Cost of the DBs will be without MCBs complete all as specified and as directed .Note - Rates are inclusive for flush(Concealed ) mounting of DB SPN . 23 Supply and fixVerticalTPN distribution board (DB), double door type, as per as per IS 8623- 1 & 3 / IEC 61439- 1 & 3. made out of sheet metal enclosure (CRCA sheet) dust and vermin proof , TPN 4 way with inbuiltMCCB 125 amp 4 pole as incomer,suitableAmps rated copper busbar, 415 Volts suitable for TPN MCB/ 4 pole Isolator, 2 neutral bar and 2earth bar and blanking plates, IP 54 protection, IK 09 impact resistance, with detachable gland plate, terminal connectors and other required hardware & fasteners cable ties for cable management(Fully insulated busbar and shrouded neutral bars),reversible door for IP 43 & IP 54 ,flush mounted to wall complete.DB shall be designed with provision for MCCB as incomer & SP / SPN MCB as outgoing as per requirement. Cost of the DBs will be with MCCB complete all as specified and as directed.Note : Rates are inclusive for flush(Concealed ) mounting of Vertical DB TPN . 24 Supply and fixing 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod/down rod as per height available at site , 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.0,Air delivery minimum 210 CMM,350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm,suitable for 230 V, 50 Hz, single phase AC Supply etc , complete with fixing arrangement anchor tpe fastener hook including connection with 1.5 sqmm mutistrand copper conductor flexiblewire from ceiling rose to fan drawn through PVC flexible conduit complete including taking down old and deposited to MES store yard all as specified and directed. 25 Supply and Fix Exhaust Fanmade of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250mm( for toilet),06 nos blades,with guard,opaque finish Aerodynamically designed & Blanced Blades,860 m³/h air delivery,Noise level less than 44db complete with outside louvers withnecessary fixing arrangment and making good to disturbed surface complete all as specified and directed . 26 Supply and Fix Exhaust Fanmade of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 300mm( for kitchen),06 nos blades,with guard,opaque finish Aerodynamically designed & Blanced Blades,860 m³/h air delivery,Noise level less than 44db complete with outside louvers withnecessary fixing arrangment and making good to disturbed surface complete all as specified and directed . 27 Supply and fixing LED building security Light fitting 60 watt, for opearting voltage between 140V to 270V system luminious efficacy not less than 100 lumen / watt ,PF-0.95 minimum, IP65/66 & IK 08 class ofprotection, 5700CCT(K),CRI between 80-85,confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012,for estimated life span ofminimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits SMPS based constant current supplywith phase to phase protection,over voltage protection , surge protection and other safety tests as per IS 15885 Part-2/Sec13, Low THD, PMMA grade high quality Transmittance lens, LED street optics LENS for uniform light distribution,weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in pressure die cast aluminium housing with SS screws with IP 65/66 protection, complete all as specified and asdirected by Engr-in-charge.Note: (i) LED fitting shall be provided for 3 years warranty. (ii) Location for Installation of LED fitting shall be as per approved drawing) 28 Supply,installation ,testing and commissioning of storage typeelectric water heater 25 Ltrs capacity , AC 240 volt, 50 Hz, 5 star rated, vertical wall mounting type made out of CRCA outer body, stainless steel storage tank, titanium enamelled heating element, thermostate, thermal cutout, glass wool incl 15mm, 450 mm long (cold water pipe) with copper cuch and 15mm 450 mm long armourd pipe (hot water pipe ) etc. complete including making necessary electrical and water connections with 2.5 sqmm 3 core copper (multistranded) cable with top indicator plug top 15 amp from geyser connnection to socket incl hold fast for fixing of new geyser and writing the MES No etc complete as specified and directed by Engr in charge. Note: (i) Cutting of wall and making good of disturbed surface in wall/roof shall be deemed to be included in the quoted rates. (ii) Wiringshall be independent from main DB to power socket located near the geyser whereas the controlled switch shall be placed outside the bath room shall be deemed to be included in quoted rates. 29 EXTERNAL WATER SUPPLY 30 Material and labour for construction of valve chamber of size 600x600mm deep dimensions (Over all internal dimension) with PCC Foundation,random rubble uncoarsed brick masonry walls, Plastering, PCC coping, white washing, mild steel chamber cover, painting to chamber cover including excavation and earthwork in any type of soil complete all as specified below : -Valve chamber shall be provided with the following specifications :-(i) Cement concrete for foundation (1:4:8) type D2 using 40 mm graded stone aggregate 150mm thick extnded up to 150mm beyond the outer face of brick masonry.(ii) Walls of valve chamber 23mm thick with precast cement concrete (1:5:8) (using 20mm graded stone aggregate) using brick masonry setting in CM 1:6 complete.(iii) Internal and exposed surfaces of valve chamber both concrete and brick masonry surface shall be plastered with CM(1:4), 15mm thick finished even and smooth. (iv) 50mm thick coping in PCC 1:3:6 type C1 over brick masonry wall.(v) Entire plastered surfaces shall be treated with 3 coat of white wash. (vi) Chamber cover shall be of 3.15mm thick MS sheet with 40x40x6mm size angle iron frame with hold fast and locking arrangement.Steel surface shall be painted with two coats of synthetic paint of fist quality over one coat of red oxide primer complete all a specified and as directed by Engr-in-Charge. 31 EXTERNAL ELECTRIC SUPPLY 32 Material and Labour for boring of holes under road, pavement, runway, taxi track, hard standing by trenches technology using ultrasound technique and necessary machine including HDPE pipe of 150 mm nominal dia PE 80 grade 0.4 Mpa working pressure for cable protection complete all as directed. Note : HDPE pipe shall be laid min 90 cm below the surface. 33 Material and Labour for Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron strip of size 32 x 6 mm as earth lead up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates,40mm thick precast RCC cover in 1:2:4 reinforced with expanded metal(weight not less than 4 kg/sqm), and frame of angle iron 25x25x6mm with lugs 02 nos with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel andwire mesh and medium grade GI earth wire protection pipe 40mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I , connected to earthing testing point and testing on completion complete all as specified anddirected by Engr-in-charge. Note: (i) The unit rate includes GI pipe up to 7.5m for protection of earth lead. For any additional length the same shall be adjusted through deviation order.(ii) The unit rate includesmain earthing lead/strip from earth electrode to test point up to 7.5 meter. (iii) In case measured value of earth resistance is recorded more than 1.0 ohms then the earthing shall be re done by the contractor without any extra cost to the department. 34 Supply,installation,testing and commissioning of LT Feeder pillar outdoor type confirming of IS 5039, CPRI approved, totally enclosed vermin proof suitably ventilated for 3 phase,wire 415 Volts, 50 Hz, AC supply, outer sheet shall be made out of 3.15mm thick CRCA sheet & MS angle section of suitable size for frames, factory fabricated, compartmentalized inner shell shall be made of out of 2.0 mm thick CRCA sheet for controlgear. Front and back door operating with locking arrangement at front. Panel shall be provided with proper ventilation arrangement from both sides including ventilation fan etc. Protection of enclosure IP 54 with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottem of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. The panel shall be provided with manufacturer name plate, heavy duty SS cable glands of adequate size for incoming and outgoing cable. EPDM gasket of appropriate shape and size provided at all joints, door and covers including uitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lug,4x legs 40 cm grouted in PCC 1:2:4 and making good disturbed surface complete and comprising of the following :- 35 (A) (i) TPN Aluminium electroytic grade bus bar of capacity 150 Amps for phases & 200 Amps for neutral and auxillary bus bar to support main bus bar duly suported on SMC/DMC, bus bar supports and insulated with colour coded heat shrinkable sleeve (ii) Digital muitifiunction meter (V,A,KW,KWH), 415 AC alongwith C.Ts of suitable ratio (set of three) complete (iii) Indication lamps LED type (RBY)= 01 set of three(iv) Internal wiring with suitable size of FRLS copper conductor cable. (B) Incomer(i) MCCB 100 Amps 4 pole confirming shall confirm to IS : 13947 (Part 3, 1993) and IEC- 60947 (Part-2), 36 KA, thermal magnetic release, adjustable overload release 64-100% of nominal current and adjustable short ckt release 3.5 to 10 in setting complete with phase separetor -01 nos.(C) Outgoing(i) MCCB 75 Amp 4 pole confirming shall conform to IS: 1394/(Part3, 1993) and IEC- 60947 (Part-2), 36 KA, thermal magnetic release, adjustable overload release 64-100% of nominal current and adjustable short ckt release 3.5 to 10 in setting complete with phase separetor -01 nos. (ii) MCB SPN 32 Amp -02 Nos. D)platform for feder pillar/LT Panel shall be of suitble size as directed, 450 mm height above ground level, the foundation shall be usingPCC 1:2:4 type B-1 , 15 cm thick, brick (sub class B) work in CM 1: 6on exposed surfaces and100 mm thick PCC 1:3: 6 type C1using20 mm graded stone aggregate as in padding on top and grouting legs of panel.Note- (i) Contractor shall subit the following Test report i.e. IP Test Report and verification of short circuit withstand test report issued by CPRI in respect of LT Panel (ii) contractor shall submit drawing for approval prior to place order. 36 Supply, installation and erection in true vertical position or to be planted a strut steel tubular swaged welded poles complete with MS base plate of 6mm thick of size 300mmx300mm at bottom duly welded and MS pole cap at top,pole shall made out of ERW MS tubing confirming to IS-1161 Part-II, type 410 SP-31 (9.0 m long) including drilling of holes of required size and nos for fixing of cross arms/clamps, pole shall be painted internally throughout using anto corrosive black bituminous paint conforming to IS: 158-1968 and externally painted with two coat of red oxide primer and two coats of aluminium paint for expose surface and two coats of black biuminous paint for portion embedded in concrete, painting three black/white bands at lower portion of pole each of 300mm height at 300mm spacing, writing pole no. with black paint in yellow paint circle 10cm dia at suitable height complete all as specified and directed by Engr-in-charge. Note : Earthwork, PCC 1:4:8 and PCC 1:2:4 shall be measured and paid seperately. 37 Supply and fixing hot pressed moulded glass reinforced polyester sheet moulding compound (SMC) junction box of dimensions 225mmx295mmx120mm, SMC confirming to IS- 13410:1992 Grade S1,IP 55, thickness of SMC sheet not less than 1.5mm, outdoor type, single door hinged with front side opening, weather proof, suitable locking arrangment at front, arrangement for incoming and outgoing cable entry at the bottom, earthing arrangement using one No. of earthing bolt of MS with 2 nuts and 2 washers provided on RH side of box,Earthing sign ha to be provided near to earthing blt complete all as pecified and comprising of the followings items as under :(a) Single phase and neutral bus bar uly colour coded of capacity 30 amps using aluminium strips of size 15mmx2mm mounted on epoxy resin base insulators, drilled holes for cable connection on bus bar including provision of PVC cable of suitable size and length from bus bar to MCB,nos cable glands. (b) MCB SP 06 Amps - 01 No.(c) Provision of clamp for monting on pole/wall,clamp made from 20mmx1.5mm flat iron of suitable shape and length duly fixed with nuts & bolts on the rear side of box. 38 Supply and fix LED street light fittings 60 watt for operating voltage between 140V to 270V system luminious efficacy not less than 110 lumen/watt, PF -0.95 minimum, IP66 protection, 5700CCT(K),CRI between 80-85 confirming to LM79 and LM 80 standards or as per IS:16104:2012 and IS:16106:2012 for estimated life span of minimum 50000 hrs consisting of high/low voltage cutt off,maintenance free isolated Electronic driver circuits SMPS based constant current supply with phase to phase protection , over voltage protection,surge protection and other safety tests as per IS:15885 Part-2/Sec13, Low THD, PMMA grade high quality transmittance lens, LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment. Heat resistance toughened UV stabilized glas fitted in pressure die cast aluminium housing with SS screws with IP 65/66 protection, complete all as specified and as directed by Engr-in-Charge 39 SEWAGE DISPOSAL 40 Supply, laying in trenches and jointing of 200 mm dia bore double wall corrugated polyethelene (HDPE) pipe of stiffness class designation SN8 including all necessary jointing material and fittings such as couplers, connectors,bends, elbows ,Tees and end caps etc complete all as specified and as directed. 41 Total amount of Schedule A Part X carried over to General Summary 42 Blank 43 Blank 44 Blank 45 GENERAL SUMMARY 46 Lumpsum price worked out by the contractorfor “BUILDINGS & STRUCTURES” as listed inSchedule ‘A Part I representingabove / below the lumpsum price as inserted by MES for Schedule ‘A’ Part I on Srl Page No. 24 47 Lumpsum price worked out by the contractorfor “EXCAVATION,EARTHWORK & SITE CLEARANCE (FOR SCHEDULES OTHER THAN SCHEDULE A PART-I)” as listed inSchedule ‘A Part II representingabove / below the lumpsum price as inserted by MES for Schedule ‘A’ Part II on Srl Page No. 26 48 Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A Part III representingabove / below the lumpsum price as inserted by MES for Schedule ‘A’ Part III on Srl Page No. 28 49 Lumpsum price worked out by the contractor for “INTERNAL ELECTRIFICATION ” as listed in Schedule ‘A Part IV representingabove / below the lumpsum price as inserted by MES for Schedule ‘A’ Part IV on Srl Page No. 34 50 Lumpsum price worked out by the contractor for “ROAD/ PATH/ CULVERT” as listed in Schedule ‘APart V representingabove / below the lumpsum price as inserted by MES for Schedule ‘A’ Part V on Srl Page No. 35 51 Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A Part VI representingabove / below the lumpsum price as inserted by MES for Schedule ‘A’ Part VI on Srl Page No. 37 52 Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A Part VII above/below the lumpsum price as inserted by MES for Schedule ‘A’ Part VII on Srl Page No. 39 53 Lumpsum price worked out by the contractor for “SEWAGE DISPOSAL ” as listed in Schedule ‘A Part VIII above/below the lumpsum price as inserted by MES for Schedule ‘A’ Part VIII on Srl Page No. 41 54 Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Schedule ‘A Part IX representingabove / below the lumpsum price as inserted by MES for Schedule ‘A’ Part IX on Srl Page No. 43 55 Total amount of SCHEDULE A PART X (MISC ITEMS) (B/R & E/M ITEMS) brought forwarded from Serial Page No. 55

Key Value

Document Fees
INR 1000 /-
EMD
INR 254000.0 /-
Tender Value
INR 1.79 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail