| 1 | Dismantling wall and ceiling boards (Fibre pulp,insulation boards/slab/blankets, any thickness incl cover fillets complete all as specified and directed. |
| 2 | S&F for Solid PVC Wall Lining consisting of 5 mm thick prelam PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed. |
| 3 | S & F 5 mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to RCC/Brick wall to make PVC Frame complete all as specified and directed. |
| 4 | Demolition of Concrete unreinforcement in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 5 | M&L for Cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete all as specified and directed. |
| 6 | M & L for cement concrete type D-21:4:8(using 40 mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 7 | Taking down door shutter with chowket of size exc 1.5 Sqm but not exc 4 Sqm each without taking off shutter from the framecomplete all as specified and directed. |
| 8 | S&F for 3 mm thick MS plates chequred or plain squared cut and attachment grade A Fe-410-W Gde E-250 complete all as specified and directed. |
| 9 | S&F for Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steelsheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 10 | Taking downcement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 11 | M&L 10 mm thickplasterin CM 1:4 on brick wall finished even & smooth without using extra cement in patches complete all as specified and directed. |
| 12 | Complete removal to existing wall treatment and material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 13 | Complete removal of existing water proofing treatment of any description and in any position including PCC padding any thickness and cleaning, wire brushing, watering & removal of debris outside MOD complete all as specified and directed.NOTE :- Unit rate quoted shall also include for removal of PVC water storage tank wherever existing carefully and refixing at the same or other position after completion of roof repair work |
| 14 | M&L PCC 1:2:4 type B1 using 40 mm graded stone aggregate as in concrete padding laid to required slope incl finishing the concrete surface fair and even without using extra cement complete all as specified and directed. |
| 15 | M & L for 10 mm thick screed bed or bedding layer of mortar in cement mortar (1:4) for laying roof finish as padding finished with WPC 3% by weight of total cement, complete all as specified and directed NOTE :- Integral WPC shall be measured and paid separately. |
| 16 | Supply only water Integral proofing compound complete all as specified and directed. |
| 17 | M&L APP polymeric membrane min weighting 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric(wt not less than 150 gms/sqm laid on primed surfaces by torch application on method including primer coats over APP complete all as specified and directed. |
| 18 | M&L for preparation of new surfaces of any description not otherwise described over 10cm width or girth and applying two coats of solar reflective aluminium paint @ 0.10 kg/sqm on membrane surfaces complete all as specified and directed. |
| 19 | Supply and fixing cost for MS reducer, bail plug and MS strip for centering and providing support for fixing stranded steel rope complete all as specified and directed. |
| 20 | Trial Boring/Drilling pilot bore of200mmto 300mm dia (suitable for 200mm casing upto 20m depth and 150 mm casing from 20m to bore level) IS: 2800 (part I), upto 140m to 180m depth ( if encountered hard rock whichcannot be encounteredat certain depth then pilot boring size can be reduced to an extent of 250 mm dia on direction of Engineer in Charge ) below ground level & lowering ofMS pipe by any suitable method (by DTH-cum-rotary or reverse rig method) to depth below ground level in any type of strata/soil/rock with sand or loose boulder including disposal of materials obtained (soil, rock,etc) from boring to distance not exceeding 40 meter with & including deploying required rig, machinery, T & P equipments, etc complete all as specified and directed. |
| 21 | Supply, assembling, lowering and levelling 200 mm nominal bore MS ERW ISI marked casing blank pipe having wall thickness 6.0 mm as perIS 1239 (Part 1)/ IS-3589 and IS 4270:2001/ (as per relavant latest IS) and jointing with electric arc welding, screwed and socketed in random length of 3 to 6 mtr, including necessary fittings i.e sockets, coupling, jointing and painting with two coats of bituminous paint of exterinal surfaces of pipe upto depth of 200 mtr below ground level complete all as specified and directed. |
| 22 | Supply, assembling,lowering and levelling 150 mm nominal bore MS ERW ISI marked casing blank pipe having wall thickness 6.0 mm as per IS 1239 (Part 1) and IS 4270:2001/ (as per relavant IS) and jointing with electric arc welding, screwed and socketed in random length of 3 to 6 mtr, including necessary fittings i.e steel sockets, coupling, jointing and painting with two coats of bituminous paint of external surfaces of pipe upto depth of 200 mtr below ground level complete all as specified and directed. |
| 23 | Supply, assembling,lowering and levelling 150 mm nominal bore MS slotted ERW ISI marked casing blank pipe having wall thickness 6.0 mm as per IS 8110 (2000) /(as per relavant latest IS) and jointing with electric arc welding, screwed and socketed in random length of 3 to 6 mtr, including necessary fittings i.e steel sockets, coupling, jointing and painting with two coats of bituminous paint of external surfaces of pipe upto depth of 200 mtr below ground level complete all as specified and directed. |
| 24 | M & L for foundation ofsize 100x 100 x100 cm at ground level for holding tube well made of plain cement concrete 1:2:4 type B-2 (using 40mm graded crushed stoneaggregates) as directed by Engr-in charge (including necessary Earth work, excavation, returning filling,removal etc ) complete all as specified and directed. |
| 25 | Supply, lowering and fixing Heavy Grade GI column pipe, ISI marked both end flanged 80 mm dia bore in 3 mtr length having wall thickness as per relavant IS as per IS-1239 complete including rubber gasket, slot cutting in flanges for passing of submersible cable and nut bolts etc complete all as specified and directed. |
| 26 | Supply, installation & testing ofMain Submersible pump set completewhich are suitable for 415 Volts, 3 Phase system, 5 HP (as suitable after carrying out yield test of bore well 50 LPM to 150LPMCapacity, 50 Hz,Head20 m - 100 m ,min 8 staging with delivery size of 50 mm, outer dia 100 mm bore complete all as specified and directed by Engr-In-Charge.Make -Kirloskar/KSB/CROMPTON or Equivalent approved by GE. Note:- Rates are incl. of suitable site of steel rope required to support the pump set. |
| 27 | Supply & Fixing of Submersible cable 3 core, 4 Sqmm, PVC sheathed 1100V grade with copper conductor complete all as specified and directed. |
| 28 | Yield test for the bore well by continuously pumping up to 24 hours as per requirement to determine safe pumping yield complete all as specifed and directed. |
| 29 | Supply and Fixing in position mild steel cap made of MS plate5mm thick with an internal threading and locking arrangement having opening for column pipe and submersible cable, for housing pipe of 200 mm dia complete all as specifed and directed. |
| 30 | Sample strata box made out of 20mm thick veneered particle board and 12mm thick plywood with 25mm x 25mm aluminium angle 2mm thick base overall length min 1500 mm x 750 mm x 100mm or as per reqmtwith front glass sheet sliding type cover with aluminium frame all around with 2 Nos Key holes plates of size 40mm x 25mm and 3mm thick complete showing name of tube well location andstrata chart of ground data showing different types of strata and selection of casing pipecomplete all as specified and directed by Engg in charge including painting of synthetic enameledpaint over to a coat of wood primer complete all as specifed and directed. |
| 31 | Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \"V\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, including hire & labour charges of air compressor, tools & accessories etc. all as per requirement and direction of complete all as specified and directed. |
| 32 | Supply & fixing ofDOL starter , 3 phase, 6-10 A, suitable for 5 HP submersible pump set including making all connections complete all as specified and directed. |
| 33 | Supply andfixing 80 mm bore Non ReturnValveas perrelavant IS, PN rating 1.0 ISI marked complete all as specified and directed. |
| 34 | M&L for making foundation thrust blocks/support pillars for holding pipe line/clamp support etc by PCC 1:2:4 type B1 (using 20mm graded aggregate size) and using extra cement making good to surfaces complete all as specified and directed. |
| 35 | Supply and Install of motorized Chemical Dosing suitable to inject solution upto 04 LPH comprising dosing pump coupled with singlephase electric motor of suitable capacity, assembly with agitator, dosing and agitator in single motor, agitator with SS sweep blade duly FRP coated, FRP tank 50- 100 ltrLtrs capacity with agitator of suitable capacitycomplete unit mounted on heavy duty MS fabricated frame duly anti corrosive paint with all accessories including UPVC pipe with valves and supportings complete all as specified and directed. |
| 36 | Supply only Chlorine test kit with coloured ample complete with all testing fitments and OT solution in Rexene finished box complete all as specified and directed. |
| 37 | Material and labour for Electrologging test for borewell for finding out fluid content,porosity and permeability complete all as specified and directed. |
| 38 | Testing of water sample and submission of reports for chemical and bacteriological analysis from the Government college /NABL cerified lab /State Govt Lab complete all as specified and directed. |
| 39 | Supply and filling Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in enquired grading & sizes as per actual requirement, complete all as specified and directed. |
| 40 | S&F well cap 200 mm dia, internally threaded & welded handed fabricated from MS sheet 3.15 mm thick and complete all as directed. |
| 41 | Deduct schedule of credit amount Rs. 670.00 to be deducted during AOC |