}

Tender For Special Repair To Bldg No. P-111, P-222, P-384 At Various Locations At Mil Stn Gandhinagar (Revised), gandhinagar-Gujarat

Tender Notice

51835730
Tender For Special Repair To Bldg No. P-111, P-222, P-384 At Various Locations At Mil Stn Gandhinagar (Revised)
Tender
Indian
Gujarat
Gandhinagar
05-11-2025

Tender Details

Tender For Special Repair To Bldg No. P-111, P-222, P-384 At Various Locations At Mil Stn Gandhinagar (Revised); 1 Demolition of brick/stone masonry built in cement/lime mortar of any mix including all quoins pillar ashlars masonryand removal complete all as specified& directed by Engr-in-Charge. 2 M&L for brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and directed 3 M & L brick work with old size sub-class ‘B’ bricks,(OLD SIZE BRICKS) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and directed. 4 M&L for brick work with old size sub-class B brick, (except bricks) bricks obtained vide item No. 1 shall be reused straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and directed. 5 M&L for PCC 1:2:4 type B1 (using 20 mm gradded stone agg )as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, drain channels, copings,parapetscopings,water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed. 6 Dismantling floor hearth or wall tiling including cement mortar incl existing plaster bedding but not backing removing serviceable tiles to store and rubbish of the premises complete all as specified and directed. 7 M&L for colour Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in dado , skirtingetc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10mm thick rendering in cement & sand mortar 1:4 complete all as specified and as directed. 8 Material and labourcolourNon - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed. 9 M&L for colour Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed. 10 M&L for vitrified colour tiles 8 to 9mm thick area of each tile 600mm x 100mm/150mm in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10mm thick rendering in cement & sand mortar 1:4 complete all as specified and as directed. 11 M&L for vitrified colour tiles 8 to 9 mmthick area of each tile of size 600mm X 600mm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed. 12 M&L for glazed ceramic coloured tiles any coloured / shedof size 300mm x 450/600mm x 6 to 7mm on vertical surface such as skirting, dados, risers to steps etc set &jointed in neat cementslurry and pointed inwhite or coloured cementto match the colour oftiles, laidover and includingrendering10mm thick in cement mortar (1:4), complete all as specified and directed. 13 M&L Vetrified Ceramic tiles(1st quality) 10mm thick double charged (square/rectangular) polished, area of each tilesexceeding 0.42 sqm, but not 1.00 sqm, in vertical surfaces as skirting and dados etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match and over 10mm thick rendering in CM 1:4 Complete all as specified and directed by Engr-in-Charge. 14 Demolition ofStone slabs and tiles of any description or thickness in floors, aprons etc. and Laidbeddedandpointedin any mortar complete all as specified and directed 15 M&L for 16 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over screed bed 15mm thick in cement mortar 1:6 complete all as specified& directed by Engr-in-Charge. 16 M&L kota stone slab 15-18 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over rendering back of tile 10 mm CM 1:4 complete all as specified& directed by Engr-in-Charge. 17 M&L machine cut kota stone slab flooring 18-20mm thick and area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishingover and including screed bed 15mm thick 1:6 cement mortar complete all as specified& directed by Engr-in-Charge. 18 M&Lfor rounding to edges of stone/granite slabs one edgesuch as in steps cooking platform , window cilland other situations complete all as specified & directed 19 Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level.) & removing unserviceable materials in low laying area, complete, all as directed by Engr-in-Charge. 20 M&L for 25 thick cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as inlevelling coarse for tiles complete all as specified and directed. 21 M&L Vetrified Ceramic tiles(1st quality) 10mm thick double charged (square/rectangular) polished, area of each tilesexceeding 0.42 sqm, but not 1.00 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match and over 15mm thick cement screeding in CM 1:6 Complete all as specified and directed by Engr-in-Charge. 22 M&Lfor 75 mm thick PCC 1:4:8 type D -2 using 40 mm graded stone aggregate as in sub basecomplete all as specified& directed by Engr-in-Charge. 23 M&LPrepolished rubber moulded Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry over 15mm thick cement screed bed in cm 1:6 with grey cementand pigments in floors complete all as specified and directed by Engr-in-Charge 24 M&Lfor 100 mm thick PCC 1:4:8 type D -2 using 40 mm graded stone aggregate as in sub basecomplete all as specified& directed by Engr-in-Charge. 25 M&L for60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sandcompelete all as specified and directed 26 M&L for80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sandcompelete all as specified and directed 27 M&L for 75 mm thick PCC 1:3:6 type C1 using 40 mm graded stone aggregate as inplinth protection surface finished fair and even complete all as specified and directed. 28 Taking downchowkhats(without taking off shutters from the frames) chowkattsn exc 1.5 sqm each complete all as specified & directed by Engr-in-Charge. 29 Taking down chowkattswith shutter (without taking off shutters from the frames) chowkatts exc 1.5 sq. m but n exc 4 sq m each complete all as specified & directed by Engr-in-Charge. 30 Taking down shutter of any decription exc.1Sqm and n.Exc 2 Sqm complete all as specified & directed by Engr-in-Charge. 31 Resecuring or easing & adusting withouttaking down of shutters exc 1.0sqm and n.exc 2.0 Sqm and adjusting with out taking down complete all as specified and directed. 32 S&F 140mm overall length floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in floor complete all as specified and directed. 33 S&F Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for three/two tracks shutters/ frames/grill for doors, windows, ventilators and partitions (Fixed portions), slinding windows, incl rollers, with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDMrubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. 34 M&L foraluminium door shutters, aluminium section weighing 0.55 kg/m, with power coating (minimumthickness 50 micron)including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodized aluminum snap beading screws etc. complete all as specified & as directed. 35 S&F door closer hydraulically regulated, designation No. 2, aluminium (Die cast) body, universal type (ISI marked) suitable for door shutters of 701 to 850mm in width aand weight between 36 to 60 Kg and fixedcomplete all as specified & as directed. 36 Supply only 4 mm thick glass sheet any shade tintglass, ordinary quality and glazing with rubber bedding in square not exc 1 sqm in each panecomplete all as specified & directed by Engr-in-Charge. 37 Supply only 3mm thick glass sheet froasted glass, ordinary quality and glazing with rubber bedding in square n exc 0.5 sq.m in each panecomplete all as specified & directed by Engr-in-Charge. 38 S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. 39 Dismantlingtimber scantlings unframed 40 sq. cm and over in section, in any position complete all as specified and directed. 40 M&L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 complete all as specified and directed. 41 Excavating in post holes in soft/ loose soils(or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified. 42 M&L for PCC Type C2 1:3:6 (40 mm graded aggregate) Cement concrete in foundations, filling and mass-concrete complete all as specified & directed by Engr-in-Charge. 43 M&L for Cutting chases, pinning in, for brick walls, making good to facings for concealed water tubing etc. cutting exceeding 10cm but not exceeding 20cm girth complete all as specified and directed. 44 M&L forStairs (framed), gate including stringers , treads, landing , balusters, hand rails etc , cooler stand , iron gate with plate sheet including cleats brackets, etc completewith gusset plate , rails braces etc. completeusing Fe- 290 (Gde E-165) quality A complete all as directed by Engr-in-charge. 45 M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steelsheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete & making good the floors/wallsin PCC 1:2:4 type B-0 & Fe -410 W-Gde -E-250 to match the existing floors/walls. 46 S&F for Pre-painted galvalumealuminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. 47 Dismantling of cement concrete (un-reinforced) kerb stone and the like of any description of and in any position not otherwise specially provided for complete all as specified and directed. 48 DismantlingPlain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. 49 M&L Pre- painted galvatume aluminum zinc coating GI based Semi-corrugated/khaprail/bending roofsteel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/Roof, fixed with self tapping screws etc complete all as directed by Engr-in-charge. 50 M&L painting to new or previously untreated steel surfaces of any description over 10cm in width or girth with two coats of synthetic enamel paint over a coat of zinc chromic primer including preparation of surfaces complete all as specified and directed. 51 M&L preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified. 52 M&L for complete scrapping existing surface andpreparation of steel surface and iron surfaces of any description over 10 cm in width or girth and applying two coat of synthetic enamel paint over one coatof red oxide , zinc chrome primerof synthetic enamel paint all as specified. 53 Writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high complete all as specified and directed. 54 Taking down cement plaster on brick or stone wall etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. 55 M&L Rendring 10mm thick on fair faces of brick work or concrete surfaces on walls, finished even and smooth without using extra cementin CM 1:6complete all as specified and directed by Engr-in-Charge. 56 M&L for rendering cement plaster 10mm thick in cement mortar 1:3 on fair faces of concrete in ceilings, chajjas, fins facia etc. finished even and smooth without using extra cement complete all as specified and directed. 57 M&L for rendering 12mm thick in CM 1:4 on stone wall surfacesfair faces of brick work & finished even and smooth without using extra cementwith water proof compound ( water proof compound paid seperatly) complete all as specified and directed. 58 Material and labour forpreparation of newly plastered/unplasteredsurfaces of ceilings & applying three coats of white wash complete all as specified and directed. 59 M&L for complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means and preparation for next treatment complete all as specified and directed. 60 M&L for 1mm thick wall care puttyon walls surface incl prepare to surface for next treatment complete all as specified and directed. 61 M&L forprepration of old surfaces of ceillingand applyingtwo coat of white wash complete all as specified and directed. 62 Material and labour for existing prepared surface of walls & applying two coats of cement base paint over a coat of primer complete all as specified. 63 Material and Labour for applying Two coats of 100% Premium Apex /equivalent exterior acrylic emulsion paint (Any shade) on new/old wall surfaces latex based having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm. complete all as spcified and directed. 64 M&L for two coats of destemper with acrylic distemper of required shade and colour as per manufactgurers specification on existing prepared wall/ceilings surfaces complete all as specified and directed. 65 S&F factory made 35 mm thick plain framed, paneled shutter (Two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces, size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using second class Hard Wood rail and styles,fixed to chowkat, complete all as specified and directed. 66 S&F factory made 35mm thick glazed and skeleton shutters made of second class hard wood, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in clause 8.24 of Section 8 in SSR Part-I, kiln seasoned and chemically pressure treated, fixed to chowkat, complete all as specified and directed. 67 M&L Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing 68 S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. 69 Supply and fixing stainless steelhinges 100mm long medium weightto pressed steel/angle iron frames by welding/screws complete all as specified and directed. 70 S&F aluminium anodised barrel tower bolt 150mm size extruded section, ISI marked & fixed complete all as specified and directed. 71 S&F extruded aluminium alloy handles 150mm size fabricated type anodised. ISI marked complete all as specified and directed. 72 S&F250 mm long mild steel sliding door boltsclip type, stove enameled black, with bright bolt not less than 12mm dia and including a minimum of 06 bolts and nuts, four on bolt plate and two on staple plate and fixed, ISI marked complete all as specified. 73 S&F mild steel helical door spring 300mm ordinary rat tail rod pattern spring including roller and roller plate complete all as specified and directed. 74 M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified and directed. 75 M&L preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. 76 Taking up or down 15mm steel tubing and connections, complete all as specified& directed by Engr-in-Charge. 77 S&F steel tubing medium grade 15mm bore with all fittings fixed complete to wall and or laid in floorcomplete all as specified & directed by Engr-in-Charge. 78 Supplying and laying of 20mm outer dia CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings in trenches complete all as specified. 79 S&F for CPVC PIPE OUTER DIA 20MM Brass Elbow (3/4 X ½) complete all as specified and directed 80 Taking up or down 20mm steel tubing and connections, complete all as specified & directed by Engr-in-Charge. 81 S&F 20mm GI tubing Medium grade fix to wall/floorcomplete all as specified & directed by Engr-in-Charge. 82 Taking up or down 25mm steel tubing and connections, complete all as specified & directed by Engr-in-Charge. 83 S&F 25mm GI tubing Medium grade fix to wall/floorcomplete all as specified & directed by Engr-in-Charge. 84 S&F Rotational moulded polyethylene water storage tanksof 500 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I includng dismantling of of old tank complete all as specified & directed by Engr-in-Charge. 85 S&F ball valves brass high pressure with polythelene float and fly net complete, screwed , iron pipes 20 mm diacomplete all as specified & directed by Engr-in-Charge 86 S&F in repairfor 20mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. 87 S&F in repairfor 25mmStop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. 88 Dismantling of cast iron, PVC or reinforced concrete drain pipes jointed in cement mortar upto 110mm and75mm bore of pipe from wall/floors etc complete all as specified and directed. 89 S&F, 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls including stack Z clamp complete all as specified and directed. 90 S&F, 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls including Z clamp complete all as specified and directed. 91 S&F 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. 92 S&F 110 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. 93 S&F, 75mm bore PVC (SWR) bend, any radius complete all as specified and directed. 94 S&F, 75mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. 95 S&F, 110mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. 96 S&F, 110mm bore PVC (SWR) bend, any radius complete all as specified and directed. 97 S&F, 110mm bore PVC vent cowl complete all as specified and directed. 98 M&L, in repair, PVC (SWR) Gully trap 125/100mm ssetting and jointing with cement mortar (1:1) complete all as specified and directed. 99 S&F, in repair, PVC (SWR) floor trap, with SS grating including jointing with solvent cement, dia of outlet 75mm complete all as specified and directed. 100 S & F in repair Soap dish, stainless steel, standard size 160x160x90mm Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed. 101 S&F in repair 19/20mm thickness factory made PVC solid board both side prelaminated approved texture as in kitchen cabinet/cupboard ( with shelves and partions) includingframe , beadingand necessary fittings & fixture likehinges, handle, magnet catch, lock etc as per manufacturers instructions andquality and make , made from rigid foam sheets having density 600 Kg/Cum and laminated sheet /PVC foil lamination . the exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter/frame shall be fire retardent having necessary scrwed holding capacity etc complete all as specified and as directed.Note :Hinges, handle, magnet catch, lock etc measured and paid supply only seperately in respective items 102 Supply only butt hingepower coatedW hinge 75mm long and 2.1/2.5mm thick to pressed to cupboard/cabinetcomplete all as specified and as directed. 103 Supply onlyfancy type stainless steel handle of size 125mm long suiatable for cupboard/cabinetcomplete all as specified and as directed. 104 Supply onlyFAST DM01SS Stainless Steel Furniture Door Catcher Magnet Size No. 2 forWadrobe, Cupboard and Almirah Door. (SS MAT)with Mounting Screwcomplete all as specified and as directed. 105 Supply onlystainless steel curvo Wardrobe/cupboard Lock 25mm thickcomplete all as specified and as directed. 106 M&L for water proofing of sunken portion consisting under mentioned items :-(i) 15 mm thick plastering in C:M 1:3 with liquid WPC at all around and base of sunken floor with proper slope.(ii) Applying a coat of bitminous primer @ 0.30 litre/sqm and conforming to IS-3384, laying APP based polyster modified membrane reinforced non wooven polyster of 3.50 Kg/Sqm (minimum), sealed by torching including demolition and removal of old concreteand provn of new lean cement concrete 1:5:10 type E 2 using 40 mm graded stone aggregate specified complete all as specified and directed. 107 S&F in repair stainless steel curtainrod of 25 mm dia(in lengths as directed) heavy duty with decorative ball type side brackets supporting hook etc , both ends and pairwith PVC rawl plug & steel screws on walls/beam complete all as specified and directed. 108 S&F in repair for PVCcorner shelves set of 3 and size ( 7 inch , 9 inch, 11 inch )complete all as specified and directed 109 Taking down carefullyaluminium windows/ventilators frame including glazed shutters & builder’s hardware complete of any size and any description and refixing in the same opening after carrying out necessary repair & replacement of unserviceable components / hardware to make it fully functional complete all as specified & as directed.Notes :- (i) Quoted rate shall deemed to include supply & fixing of new joining cleat, aluminium beading, glazing clips, rubber packing, stays including cutting of old styles etc & adjusting the same appropriately as directed.(ii) Glazing, new aluminium sections for frame/shutters, builder’s hardware such as handles, hinges shall be measured & paid for separately.(iii) Loose corner joints of frame & shutters shall be tightened by providing suitable cleats made out of aluminium angle of appropriate size fixed with nut & bolts to make the joints at 90º. 110 S&F in repair stainless steelwire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm and fixed tinned tacks or GI wire stampe and including woodencomplete all as specified and as directed. 111 Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 20mm bore of pipe complete all as specified and directed. 112 Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 25/32mm bore of pipe complete all as specified and directed. 113 S&F, in repair, 40mm bore, low density polyethelene pipe (LDPE) of pressure rating 6kgf/sq.cm fixed to walls, ceilings or in floors etc. complete all as specified and directed. 114 S&F in repair fancy type bib 15mm boretaps, chromium plated alloy with crtuch or butterfly handle,screwed down, screwed for iron pipe or for brass ferrule and fixed omplete all as specified & directed by Engr-in-Charge. 115 S&F in repair fancy type long body15mm bore bib taps, chromium plated alloy with crtuch or butterfly handle,screwed down, screwed for iron pipe or for brass ferrule and fixed omplete all as specified & directed by Engr-in-Charge. 116 S&F in repair angle valves/stop valve ,fancy type, chromium plated alloy screwed down high presure, screwed both ends for iron pipe or for unions of 15 mm dia complete all as specified & directed by Engr-in-Charge. 117 S&F in repair vitreous China squatting pan Orissa pattern size 580x440 mm, white with integral foot rest including P or S trap front or back inlet excluding flushing cistern and flush pipe including connection to trap and flushing pipe etc and making good to floor complete all as specified and directed. 118 S&F in repairPVC valveless, syphonic action type, flushing cistern of 10 ltrs capacitylow level, white, with intel, ball valve, float and handle including bracketscomplete all as specified & directed by Engr-in-Charge. 119 S&F in repair PVC connection of 15mm bore with2 Nos. PTMT nuts, 60cm long fixed with one end to pillar tap & the other end to stop cock or iron pipe all as directed by Engineer-in-charge. 120 S&F in repair fancy typePillar tap,swan neckcast copper alloy with capstan heads, chromium plated, screwed down high pressure with or withoutlettered Hot or Cold with long screwed shanks & fly nuts, screwed for iron pipes of 15mm bore all as specified 121 S&F in repairlooking mirror 5 mm thick selected quality of any size including necessarymoulding , stainless steel cup and washer etc complete all as specified. 122 S&F in repairkitchen sink without draining board bowl size 18x16x8 inch of made out of stainless steel heavy dutywith plugs, washers and waste pipe includingwaste coupling and waste pipe complete all as specified & directed by Engr-in-Charge. 123 S&F in repairtubular towel rail, stainless steel, 20mm dia, ‘D’ type, 60cm long between flanges fixed to wall complete all as specified and directed. 124 M&L for formwork to soffits of suspended slabs such as wash hand basin ,roof slabs, floor slabs, landings and similar work, not exc 200mm thick (horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and directed. 125 M&L for reinforced cement concrete nominal mix1:2:4 ,using 20mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like.Note :- Reinforcement & formwork shall be measured and paid for separately. 126 M&L for mild steel TMT bars 10mm dia & over cut to length bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and bending with and including MS wire (annealed) not less than 0.9 mm dia completeall as specified and directed. 127 Demolition Mud in roofs, any thicknes, including plastering , existing tretement and cleaning (whether full thickness removed or only or part there of)etcin all respect and preparing it for further treatment and taking out and disposal of debris & rubbish to a distance exc 1 Km but not exc 1.5 Km complete all as specified & directed by Engr-in-Charge. 128 M&L for providing cement concrete intype B0 1:2:4 (using 12.5 mm graded crushed stone aggregate) as in roof padding,laid to(consolidated thickness 65mm or less) as leveling course, laid and compacted inmin slope 1:30 over roof complete all as specified& directed by Engr-in-Charge. 129 M&L for 10 mm thick renderingin CM 1:4 as in roofover green concrete surface finished even and smoothusing Lequid WPCcomplete all as specified. Note :-Lequid WPC will be measured and paid seperately) 130 Supply only integral liquid water proofing compound (ISI marked) complete all as specified and directed. 131 S&F, in repair, vitreous china wash basin, white, flat back of size 450mm x300mm including brackets grouted in cement mortar 1:2 in wall complete all as specified and directed. Note :- Supply only pillar taps, waste fittings, PVC connection, PVC waste pipe shall be measured and paid separately. 132 Disconnecting, setting aside (or lowering if required) andCleaning & removing all scale and dirt etc from HDPE water tanks of 500 litres capacity (Tanks placed on top of roof)and from mouths of circulating pipes etc including washing the tank with bleaching powder and hoisting, reconnecting and re-fixing in position including writing the date of cleaning of tank with synthetic enamel (black/white) paint of size not less than 10cm of each letter complete, all as specified and directed. 133 M&L for roof treatment using APP based polymeric membrane minimum weighing not less than 3kg/sqm black finish reinforced with non woven polyster matt with thermo finish (wt. not less than 150 gms/sqm) laid over compatible bitumen primer @0 .30 liters per sqm and bitumen 85/25 @ 1.20 Kg per Sqm with help of torching with a proplyne or a butane gas using torch with minimum overlap of 75mm at side and 100mm at ends and sealing including applying a coat of bitumen primer & bitumen 85/25 applied hot all as per manufacturer instructuions. For parapet in a groove (No separate payment will be made and measurement will be done for horizontal surfaces) including applying a coat of heat repallant bitumen aluminium paint @ 0 .1 liter per Sqm on top of treated surface of roof complete all as specified and directed. 134 S&F,in repair, wall mixer chromium plated (2 in -1) with arrangement for overhead shower with 220 mm max long bend pipe including 125mm x125mm over head shower complete all as specified & directed. 135 S&Fin repair sink cock faucet wall mountedchromium platedand suitable screwed for iron pipes of 15mm bore GI pipeall as specified complete all as specified & directed. 136 S&F, in repair, stainless steel Kitchen plate rack of overall minimum size 750mm x 750mm and 230mm deep, with partitions for small/large plates etc made out of stainless steel 24 Gauge, fixed with rawl plug and CP steel screws all as directed. Note : Weight of rack shall not be less than 4.00 Kg. 137 Dismantling/Demolition/Chipping carefully loose/distressed portions of reinforced cement concreteto a depth or thickness varying from 10 mm to 100mm (reinforcement cut as required to facilitate demolition) work by means of sharp chisel, low impact hamer without damaging existing strong concrete upto the suitabale depth of unsound concrete in beams, roofs, chajjas, columns, staircase, landing, parapets, soffits of slabs and similar suspended worketc incl disposal of broken material/malba to the distance of 50m complete all as specified and directed.Notes :-(i) Work to be carried out in patches.(ii) The rates for scaffolding system to be used upto 15 mtr workable height shall be deemed including in the above rates and no extra shall be paid over & above the quoted rates. 138 Removal of damaged concrete and surface preparation: M&L for Surface preparation including removal of all loose particles, plaster, tiles, laitance, dust, curing compounds, floors hardeners, oil, grease, fat, bitumen and paint, other fixtures etc. Removal of existing affected, distressed, loose cover concrete including loose damaged concrete from slab up to beyond the corroded steel reinforcements to a depth of 10 mm minimum behind the reinforcement only at affected concrete (Good & sound concrete should not be chipped / damaged) by chipping / hacking with chisel and hammer or by mechanical means like light weight chisel hammer, pneumatic chippers, making saw cut at periphery to avoid feather edge and removal and disposal of debris at designated location within plant premises including labour, tools,electricity, plant and machineries etc. complete as directed by Engg.in charge. Depth of chipping may vary upto 100 mm. Cleaning of rust/ scales/corrosion from reinforcement bars using high pressure water jetting etc. complete.(i) Work to be carried out in patches.(ii) The rates for scaffolding system to be used upto 15 mtr workable height shall be deemed including in the above rates and no extra shall be paid over & above the quoted rates. 139 Reinforcement Rust Removal & Corrosion Protection:M&L for Cleaning as directed & specified all corrosion / rust / scales from reinforcement bars using rust remover ShaliRust Off from STP Ltd or Equivqlent leaving to dry for 30 mins & washing surface with fresh water as required to exposed reinforcement bars complete as specified also providing & applying inhibtion coats/system to exposed reinforcement bars after drying & also new bars after cleaning & removing scales and rust completely as specified. Two component inhibitor coating ShaliPrime Zn primer of STP Ltd or equivqlent. make as approved by engineer shall be used as per manufacturers specification in two coats including all labour tools tackles, necesary surface preparation complete all as specified and directed(i) Work to be carried out in patches.(ii) The rates for scaffolding system to be used upto 15 mtr workable height shall be deemed including in the above rates and no extra shall be paid over & above the quoted rates. 140 Additional Reinforcement:M&L forcutting, fabricating new reinforcement for providing additional steel reinforcement to compensate corroded reinforcement in existing member etc. and fixing with old existingreinforcement which was reduced by 20% or more of its original diameter as required as provided in original structure and additional steels as directed by EIC as required welding or tying with 16 gauge annealed binding wire complete as per specifications and as directed by EIC.(i) Work to be carried out in patches.(ii) The rates for scaffolding system to be used upto 15 mtr workable height shall be deemed including in the above rates and no extra shall be paid over & above the quoted rates. 141 Epoxy bond coat on old concrete:M&L for Providing and applying one bond coat on the prepared surface to receive new polymer mortar/polymer modified concrete, with two components epoxy based bonding coat ShaliBond Concrete of STP Ltd. in one full coat. Laying of reinstatement polymer mortar or micro concrete shall be completed within the overlay time of bonding coat. This bond coat act as bonding agent between old and new concrete. Item rate is inclusive of the meterials all labour, supervision, tools and tackles and transportation etc. complete as per specification and as directed.(i) Work to be carried out in patches.(ii) The rates for scaffolding system to be used upto 15 mtr workable height shall be deemed including in the above rates and no extra shall be paid over & above the quoted rates. 142 External Cement plaster:Providing and applying 15mm thickplaster using CM (1:3) for 1st coat and (1:2) for second coat including waterproofing admixture such as ShaliPlast IW of STP Ltd or equivalent @ 150 ml per 50 kg of cement etc. complete.(i) Work to be carried out in patches.(ii) The rates for scaffolding system to be used upto 15 mtr workable height shall be deemed including in the above rates and no extra shall be paid over & above the quoted rates. 143 Protective coatings for Enviornmentally exposed external surfaces:Providing and applying an elastomeric membrane forming system with anti-carbonation and breathing properties, the system, ShaliKote AC WB with Primer, of STP Ltd or equivalent, based on water based acrylic/acrylate polymers. The system consists of one coat primer (ShaliPrime AC WB) over prepared surface and polymer coating (ShaliKote AC WB) to give film thickness of 200 – 225 microns for two coats depending on method of application and smoothness of concrete surface. Surface Preparation should include grinding or wire brushing and removal of all loose particles, dust, oil and other contaminants. For smooth surface finishes, final preparation should include filling of all bugholes / uneven surfaces in the concrete, using suitable putty or equivalent. Polymer coating should be in suitable approved shades, including suitable surface preparation as described above, cost of materials and labour for applying the above coating, etc.(i) Work to be carried out in patches.(ii) The rates for scaffolding system to be used upto 15 mtr workable height shall be deemed including in the above rates and no extra shall be paid over & above the quoted rates. 144 M & L pre stressed pre cast RCC (M-25 grade) column cross section 150 mm x 150 mmwith contineous vertical grooves of size 60 mm x 35 mm at two sides of column to receive the precast panels including reinforced with 7 nos wires of 3 mm dia high tensile corbonized steel surfaces finished even and smooth including errecting in position all as specified and as directed incl taking down of old column from sub base PCC complete all as specified and directed. 145 M&L pre stressed pre cast RCC (M-25 grade) panels of cross section of panel (300X45 mm) reinforced with 4 nos wires of 3 mm dia high tensile corbonized steel, including fixing in position in between column grooves and jointing and flush pointing of all horizontal and vertical joints of panels with cement mortar 1:3 complete all as specified and as directed incl taking down of old Panel complete all as specified and directed. 146 M&L for non asbestos fibre reinforced designer cement boardfalse ceiling made out of E-board classic of size 600 x 600 x 4 mm thick, GI frame consisting of main Tee of size 38.50 x 24.00 mm and cross Tee of size 28.50 x 24.00 mm thick made out of PGI sheet 0.30 mm thick doubled at web and single at flange, flange covered with powder coated sheet 0.25 mm thick and angle 24.00 x 24.00 x0.4 mm thick powder coated suspended with GI wire 3 mm dia and up to 2 Mtrs long complete including plugging fixing of angle to brick walls with steel rawl plugs @ 450 mm c/call as per manufactures instructions etccomplete all as specified and as directed 147 M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. 148 Dismantling Wall and ceiling boards including framework (PVC penelling incl fillet, fibre, pulp, insulation, etc.) or insulationboards/slabs/blankets, any thickness, including cover fillets complete all as specifiedand directed 149 M&L for mirror polishing on granite/ Kota stone work where ever required to give high glosss finish complete all as specified and direted. 150 M&L for cutting holes into or through brick walls built in cement mortarandmaking good in cement mortar 1:3 or cement concrete 1:2:4, type B-l as required, superficial area exceeding 150 sq. cm but not exc 400 Sq CMincluding necessary scaffolding, if required complete all as specified and directed. 151 M&L for sand filling under floor or in foundation including spreading & ramming and levelling in layer not exc 25cm thickcomplete all as specified. 152 Labour only rifixingforexcept interlocking paver block any shape and sizeof 60 mm thicknesscomplete all as specified. 153 Labour only rifixing forexcept interlocking paver block any shape and sizeof 80 mm thicknesscomplete all as specified. 154 Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed 155 Material & Labour for providing and fixing stainless steel (Grade 304) railing/gate made of hollow/solids tubes/bars channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement compete all as specified and directed by Engr-in Charge. 156 M & L Pre cast RCClouvres and jallies, type B0 1:2:4 ,12.5mm graded stone aggregate ,25-30mm thick set in cement mortar 1:4(measuredsolid) , including all mouldings completeand design /pattern decided by Engr-in-Charge. 157 S&F for Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed. 158 M&L for wiring with and including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH cable 1100 Volts grade, ISI marked with valied CML number drawn in PVC Conduit concealed wiring and including medium grade PVC Conduit25mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including modular sunken box/ Galvanized box with 4,6,8,12 & 16 nos modular plate for fixing for One multi purposesocket 5 Amps 3 pin socket, on the same board complete all as specified and directed for the following :- 159 M&L for wiring with and including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH cable 1100 Volts grade, ISI marked with valied CML number drawn in PVC Conduit concealed wiring and including medium grade PVC Conduit25mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including modular sunken box/ Galvanized box with 4,6,8,12 & 16 nos modular plate for fixing for One multi purposesocket 5 Amps socket 3 pin outlet indpendent but below the switch board of light points in the same vertical planes with cables complete all as specified and directed for the following :- 160 Taking down steelrolling shutter push pull or manual type/gear types including top hood cover anchoring rod, hasp and staple etcand refixing same in position afternecessary repairs such as cleaning,replacement of rusted nuts and bolts with required / welding grinding andall moving parts,guide rail including greasing the guide rail gear worm, gearbox ,adjusting anchoring rod ,straining tensile spring etc as required to make rolling shutter fuctional and making good any damage to the existing shutters to the following opening:- (a) Area of Shuttersexc 5 Sqm but n exc 15 Sqm each. 161 Taking down existing unserviceable rolling shutter/steel gate/collapsible steel gatecomplete of any size and any type andremoving from site complete 162 Taking down carefully copper/aluminum point wiring (light, fan,socket or power) complete,including fixture and fitting such asas switches, ceiling roses, pendants, regulators, sockets,etc excluing light fittings etc,removing materials to store for keeping in safe custudy or for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surface of walls, ceiling, floor etc to match with the existing surface. 163 M&L for wiring with and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH cable 1100 Volts grade, ISI marked with valied CML number drawn in PVC Conduit concealed wiring and including medium grade PVC Conduit25mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including modular sunken box/ Galvanized box with 4,6,8,12 & 16 nos modular plate for fixing for modular switches, sockets and fan regulators etc. complete all as specified and directed for the following :- 164 (a)One light/fan/Exhaust fan point controlled by oneswitch complete all as specified and directed. 165 (b)One light point controlled by two wayswitch complete all as specified and directed. 166 (c) One bell buzzer point controlledby one push button independent complete all as specified and directed. 167 M&L for wiring with and including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH cable 1100 Volts grade, ISI marked with valied CML number drawn in PVC Conduit concealed wiring and including medium grade PVC Conduit25mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including modular sunken box/ Galvanized box with 4,6,8,12 & 16 nos modular plate for fixing for onemulti purpose socket 5 Amps 3 Pin, Independent board complete all as specified and directed for the following :- 168 M&L for wiring with and includingmulti stranded copper conductor 4 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with valid CML number, drawing throughin and including medium grade, rigid non metallic, PVC concealed conduit of 20mm bore and including cutting chases for conduits and sunken for boxes, its accessories & including with multi stranded copper conductor 4 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLSH cable, green colour,1100 volts grade, ISI marked with valid CML number ascontinuity earth wire terminating with provision ofsunken concealed terminal boxescomplete all as specified and directed. 169 S & F Switch Modular (piano) flush button single pole one way 6 amps 1 module with suitable plate and cover complete all as specified and directed. 170 S & F Socket outlet flush modular (piano) type 3 pin 6 Ampswith suitable plate and cover complete all as specified and directed. 171 Supply and fixingmodular 16 Amps socket 2/3 pincomplete all as specified and as directed by Engr-in-Charge. 172 S & F Switch Modular (piano) flush button single pole one way 16 ampswith suitable plate and cover complete all as specified and directed. 173 S&F in switch modular piano, flush button single pole, two way 5 Amps complete all as specified and directed. 174 S&F in modular bell push,flush type, 5 amps complete all as specified and directed. 175 S&Fin repair Ceiling rose, PVC/poly carbonate,isolated bodythree terminals,complete all as specified and directed 176 M&L for bell electric, Dingdong type A.C. 230 Volts, single pole complete all as specified and Directed 177 M&L formodular ceiling fan regulators, Electronic step type type, AC, 230 Voltscomplete all as specified and directed. 178 S&F, lamp holder,insulated body with back plate for batten fittings complete all as specified and directed. 179 M&L and labour for taking out LT cable, after taking electrical shutdown complete cable XLPE Insulated, galvanized steel strip or wire armoured, heavy duty LT electri power cables 1100 Volts grade with stranded aluminium conductor of size 4 Core x 16 Sqmm complete all as specified and directed. 180 M&L and labour for taking out LT cable, after taking electrical shutdown complete cable XLPE Insulated, galvanized steel strip or wire armoured, heavy duty LT electri power cables 1100 Volts grade with stranded aluminium conductor of size 4 Core x 10 Sqmm complete all as specified and directed. 181 M&L and labour for taking out LT cable, after taking electrical shutdown complete cable XLPE Insulated, galvanized steel strip or wire armoured, heavy duty LT electri power cables 1100 Volts grade with stranded aluminium conductor of size 2 Core x 4 Sqmm complete all as specified and directed. 182 S&F GI tubing light grade galvanised /Medium Grade PVC with all fittings like Bend Elbow Tee etc& fixed complete wall/pole for 40mm bore complete all as specified and directed. 183 S&F GI tubing light grade galvanised/Medium Grade PVC with all fittings & fixed complete wall/pole for 50 mm bore complete all as specified and directed. 184 M&L for horizontal drilling, in any type of soil, using trenchless technology suitable for insertion of GI pipe /Medium Grade PVCandLT cablesalong the pipe complete all as specified and directed of 50mm dia of pipe complete all as specified and directed. 185 Material and Labour for Double Compression cable Gland weatherproof suitable for cable 10 to16 Sqmm complete all as specified and directed. 186 Supply, installation, commissioning and testing, in repair, Time switch panel, LT (415 Volts, 50 Hz , 3-phase, 4 wire supply), CPRI approved, plinth mounted, factory made, outdoor type of size (1500 x600 x 1000) mm weather and vermin proof (Protection Class IP-54) made out of 50mm x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.2 mtr in ground and 0.5 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:-(a) Incoming supply:- (i) Mains incomer, 63 A, 25 kA, 4-pole MCCB with adjustable thermal-magnetic release - 01 No(ii) Indicating lamp Neon type for R-Y-B - 3 Nos (vi)Extended rotary handle & spreader terminals for above MCCB-01 Nos (vii) 6 A TP MCB-01 Nos MAIN BUSBAR SIZE- 25 X 10 mm. EC grade aluminium busbarsMAIN BUSBAR SIZE (For neutral)-25 X10 mm. EC grade aluminium busbarsEARTHING BUS 25 x 10 mm. EC grade aluminium busbarsPANEL MOUNTING-Floor mountedCABLE ENTRY-Bottom for both incoming and outgoingPANEL FABRICATION-From 11G CRCA sheet steelFINISHING-Powder coating (min. 80 micron) after 7-tank process to shade RAL-7035PANEL DIMENSIONS- App. 750 mm. (H) X 700 mm. (W) X 450 mm. (D) 187 Supply, installation, commissoning and testing, factory made CPRI approved, LT Metal Box size 120cmx 90cm x 30cm, wall mounted board made out of CRCA sheet of 2 mm thick indoor type totally enclosed weather, dust and vermin proof with front opening hinged door and locking arrangement mounted on MS flat iron (40x6 mm and 6 long) 04 No clamp welded to 40mm x 40mm x 5mm size angle iron frame alround panel body duly grouted on wall, 415 volts 3 phase, 4 wire AC 50 HZ having aluminium bus bar insulated with PVC sleeves, space for fixing single phase KWH electric meter of suitable capacity 04 Nos, copper lugs, spacers, mounting channels, rubber gasket, locking knobs, hylam sheet pieces, PVC shrinkable sleeves, nuts and bolts, washers etc and suitable size single core copper wire connections, suitable compartments and epoxy powder spray paint with primer complete all as specified including the following accessories including taking down old unserviceable distribution board, taking down and refixing serviceable electric KWH meter in new panel (all as per sample) complete comprising the followings :- (a) Incoming supply:- (i) MCCB, 415 Volts, 4 Pole, 25 KA breaking capacity of 63 Amps - 01 No. (ii)R-Y-B phase, LED indicating lamp - 03 Nos (iii) 200 Amp TPN main aluminium bus bar (b)Outgoing supply:- (i) MCB, SPN, 40 Amp, 10 KA = 04 Nos (ii) Space for mounting single phase energy meter - 04 Nos (iii)Copper cable 6 Sqmm wire and open terminals for all feeders. 188 M&L for Repair of CableBy Insertion of Straight trought Joint Cold Shrink Typefor LT Cable 10 Sq mm 2 Corewith all accessories all as spd and directed 189 S&F, aluminum / Tinned lugs for cable size 2.5 to 16 sqmm complete all as specified and directed. 190 Material and labour for taking out any type of light fittings completeall as specified and directed 191 S&F, MCB’s single pole,6 to 32 Amps 240 volts with ‘C’ curve,10KA, fixed in sheet metal board complete including connecting completeall as specified and directed 192 S&F, MCB’s SPN 40 Amps 240 volts with ‘C’ curve, fixed in sheet metal board complete including connecting. 193 S&F, LED light fitting, 1x20W, 220 V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed 194 S&F, LED light decorative ultra slim round profile LED lighting with extured polycarbonate enviromental friendly energy effecient ready to use pack2 feet,9 wattwatt 220 V ACincluding connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 195 Taking down existing Geyser and keeping in safe custudy and re- installation the same after completion of work completed all as per specified and directed. Cost of renstallation of geysers included in quoted rate. Any cost of reinstallation of geyser not to be given. 196 Taking down existing Ceiling fan and keeping in safe custudy and re- installation the same after completion of work completed all as per specified and directed.Cost of renstallation of geysers included in quoted rate. Any cost of reinstallation of geyser not to be given. 197 Taking down existing Electric meter and keeping in safe custudy and re- installation the same after completion of work completed all as per specified and directed. Cost of renstallation of geysers included in quoted rate. Any cost of reinstallation of geyser not to be given. 198 S&F, Distribution Board SPN 8 way, 240 volts, factory made powder coated, double door with neutral and earth link, suitable for fixing MCB,s complete including connecting all as specified and directed. 199 Excavation in trenches, n.exc 1.5 Mtr wide& n.exc1.5 Mtr depth for foundation, etc, or for shafts, wells, casspits, manholes, pierholes etc. n. exc 10 sqm on plan & n. exc 1.50m in depth and getting out in soft and loose soil complete all as specified & directed. 200 M&L for returning, filling in, including spreading, levelling, watering and well ramming the approved soil in layers n.exc 25cmthick complete all as specified & directed. 201 Removal of surplus excavated soil to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above starting point complete all as specified & directed. 202 M&L for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Note : Depth after punning shall be measured and paid. 203 Supply and Laying Class LV, Type I, flat, size 250mm x 150mm x 40 mm laid flat in trenches as protection to LT cable complete all as specified and as directed. 204 Supply and fix LED light fitting 1 x 10 W bulk head luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size 205 M&L sub-main wiring with 2 single core 6 Sqmm PVC insulated, unsheathed, 1100Volts grade, copper multi stranded conductor drawn in PVC casing and capping ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 6.0 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire drawn through and connected to main switch/ DB and testing on completion.Note: (i). 2 run of main conductor and one run of earth conductor shall be measured as one length. 206 M & L for earthingcomplete with galvanized steel earth plate electrode60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead galvanised iron 4mm dia wire by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of2009.Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmmin lieu of CI cover. 207 M&L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth lead 25x4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using earth strip of 25x4mm as earth lead all as specified and testing on completion includingprovisionof earth lead protected by 40 mm dia light grade GI pipe & watering pipe shall be 15 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions:-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 15 mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 20 mm bore light grade 7.5m. 208 M/L for PCC (1:4:8) type D-2 using 40mm graded aggregate as in foundation/surface repair for pole / Platformmakely base for mounting of light fittings including grouting of both of appropriate size,cost of bolts,nuts etc shall be deemed yo included in quoted rateetc complete all as specified and directed. 209 M/L for PCC (1:3:6) typeC-1 using 20mm graded aggregate as in foundation/surface repair for pole / Platform,makely base for mounting of light fittings including grouting of both of appropriate size,cost of bolts,nuts etc shall be deemed yo included in quoted rateetc complete all as specified and directed. 210 Supply and fix exhaust fan, steel body AC single Phase 230V of size 300mm sweep, 1500 RPM with, blades and frame and louvers, shutters complete all as specified and directed by Engineer-in-Charge.Note : Including all mosonary cutting and also making good dismantled portion in qoted rate. 211 Supply & FixLED 30 Watt (5700K) Bldg Security light fitting, and including with GI light grade Pipe 32 mm dia bracket with connected with 3 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting in position at site all as specified and directed.Make : Wipro/Philips/CG 212 S&F, in repair, LED luminaire 600mm x 600mm, 35/36 watt, 220 V AC Surface mounted type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size all as specified and directed. 213 S&F PVC insulated and PVC sheathed copper conductor cable of size 1.5 Sqmm, 3 core, 1100 volts grade, multistranded, passing throuth pipe, on pole/wall from juntion box to street light fitting complete all as specified and directed. 214 Supply and fixing LED Out doorunder Water Proof Fountain Light Fittings complete IP-68, 220 Volt Ac50 Hzof RGBColour 36 Watt (12 x 3 ) complete all as specified and directed. 215 Supply and Fixing3 terminalCeiling Rose Modular type complete all as specified and directed.

Key Value

Document Fees
INR 500 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail