Tender For Additional / Alternator Of Bldg No Np-28, Np-23 And Np-22 Of Engr Regt Under Ge (North) Udhampur, udhampur-Jammu And Kashmir

Tender Notice

51834637
Tender For Additional / Alternator Of Bldg No Np-28, Np-23 And Np-22 Of Engr Regt Under Ge (North) Udhampur
Tender
Indian
Jammu And Kashmir
Udhampur
13-11-2025

Tender Details

Tender For Additional / Alternator Of Bldg No Np-28, Np-23 And Np-22 Of Engr Regt Under Ge (North) Udhampur; 1 Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed. 2 10 mm thick rendering on surfaces other than fair faces of brick work or concrete surfaces, finished even and fairon walls in cement mortar 1:6 complete all as specified. 3 5mm thick rendering on fair faces of concrete surfaces, finished even and smooth,as in ceiling in cement mortar 1:4 complete all as specified. 4 15 mm thick renderingon fair faces of brick work or concrete surfaces, finished even and fairon walls in cement mortar 1:4 complete all as specified. WPC should be mixed as per manufacturer instructions and paid separately. 5 Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm including 15mm thick screeding in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately). Applying RCC roof slab top by wire brushingand cleaning thedust and forign materail etc completeand applying a coat of hot blown bitumen 85/25 grade @ 1.20kg/Sqm over a coat of bitumen primer @ 0.40 ltrs/Sqm and there after laying of a layer of APP based polymeric 3mm thick membrane (five layered with centre core as 100 microns high molecular high density polyethylene film)weighing not less than 3.5 kg/Sqm andreinforced with polyster non woven fabric (wt. not less than 150 gms/Sqm) laid on bituminous surface by press applicationmethod with 75mm side overlap and 100mm end overlap. The membrane has to be laid with LPG torch application and overlaps sealed and finished neat, after that applying one coat of bitumen 85/25 grade on top surface @ 1.20 kg/Sqm and blinded with premier dry sand@ 0.5 kg/Sqm dusted over bitumen coat, complete all as specified and as directed. 6 Supply only liquid water proofing compound,complete all as specified & directed. 7 Taking up or down steel tubing of 15 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed. 8 Taking up or down steel tubing of 20 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed. 9 15mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls andor laid under floors etccomplete all as specified and as directed. 10 Fixing only steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 15 mm, all as specified. 11 20mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls andor laid under floors etccomplete all as specified and as directed. 12 Fixing only steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 20 mm, all as specified. 13 Cutting chases, pinning in making good to facings in brick walls where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as specified and as directed. 14 Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 1000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm (Minimum weight210 gram) etc),incl dismantling existing water tanks, complete all as specified and as directed. 15 18 mm thick prelaminated particle boards, interior grade, prelaminated one side with decorative choice lamination and other side balancingwhite lamination fixed with screws as in shelves , cup board shutters etc, complete all as specifiedand directed. 16 Extra over rates for teak wood lipping, 6mm thick fixed with nails complete all as specifiedand directed. 17 Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc.complete,of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer,including filling voids with PCC 1:3:6 type C-0 complete all as specified and as directed. 18 Description all as per item No 17 above but frame size 105 x 60 mm. 19 Factory Made Solid PVC Moulded Door Shutter wall nut colour, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelaminated PVC Sheet on the front face & 2mmcolour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specification & drawing as per specification & drawing, complete all as specified and as directed. 20 Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing, complete all as specified and as directed. 21 35mm thick, factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters shall be as per IS:1003; supplied and fitted to chowkats complete, all as specified and directed. 22 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified & directed by Engr-in-Charge. 23 Steel windows & ventilators/box type comprised of tubular frame and shutters made out of 1.58mm thick MS steel tube factory made with double side shutters wire gauged shutter & glass glazed shutter (Grill,wire Mesh and glass panes shall be measured and paid separately) with side hung shutters with steel handle and steel peg stay dovetailed of welded incl 2 Nos tower bolts 150mm long for each leaf incl other fittings, hinges, handles tarred hold fasts etc. all as shown on drg No CEUZ TD-1517/15 sheet1/3 to 3/3 incl a coat of red oxide primer complete all as specified and directed. 24 Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed. 25 Stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed. 26 Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and as directed. 27 Preparation of new steeland iron surfacesexceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide/zink chrome primer, complete all as specified and as directed. 28 Factory made prepolished rubber moulded vibromatic Chequred cement concrete tiles 30cmx30cmx22-25mm thick, set jointed and pointed in neat cement slurry with grey cement and colour pigment to matc over and including 15mm thick screed bedding layer in CM (1:6) complete all as specified. 29 Treatment of sunken floor surfaces with 0.488 kg/Sqm first layer of slurry of cement mixed with acrylic based polymer modified cementitious composite compound @0.253 Kg/Sqm. This layer shall be allowed to be cured for 4 hours and then applying in second layer slurry of cement @ 0.242 Kg /Sqm mixed with acrylic based polymer based modified cementitiousc omposite compound @0.126 Kg/Sqm. This layer shall be allowed to be cured for 4 hours incl fixing of 32 mm dia GI spout pipe 450mm long complete all as specified and as directed. 30 Dismantling cast iron work of any description etc. complete all as specified and directed. 31 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent, fixed in repairs, complete all as specified and directed. 32 PVC (SWR) P’ trap fixed in repair , complete all as specified and directed. 33 Stack clamps made out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100/110mm bore pipe fixed in repairs, complete all as specified and directed. 34 Stack clamps made out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75mm bore pipe fixed in repair, complete all as specified and directed. 35 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. 36 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. 37 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with excess door fixed in repairs, complete all as specified and directed. 38 75mm bore PVC (SWR) junction single, (Single T) equal or unequal with excess door fixed in repairs, complete all as specified and directed. 39 110mm PVC (SWR) bends any radius fixed in repairs, complete all as specified and directed, 40 75mm PVC (SWR) bends any radius fixed in repairs, complete all as specified and directed. 41 Machine cut kota stone mirror polishing slab flooring 20-25mm thick over 20 mm thick cement screed in CM 1:4 base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. 42 Machine cut kota stone 20-25mm thick as in riser of steps, skirting, dado and pillar laid over cement screed base and jointed with white cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, over and including 10 mm thick rendering in cement mortar 1:3 as in backing coat for laying wall tiles, complete all as specified and as directed. 43 Granite 20mm thick in single piece (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking plat forms, risers and like in over 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rounding of edge, complete all as specified and as directed. 44 Double charged coloured vitrifiedtiles 10 mm thick (square/ractangular) polished area of each tiles exceeding 0.42 Sqm but not exceeding 1 Sqm as in floors, set and jointed in neat cement slurry and pointed in colouredcement to match the surface laid over & incl 10 mm thk screed bed in CM 1:4 complete all as specified and directed. 45 Ditto all as per item above but as in skirting over vertical surfaces& including 10 mm thick cement mortar 1:4 rendering, set and jointed with grey cement slurry and pointed in grout of matching shade of tiles complete all as specified. 46 450mm x 300mm x 7 mm thick first quality colouredglazedceramic tiles as in skirting/dadoincluding 10 mm thick cement mortar 1:4 screed, set and jointed in neat cement slurry and pointed incoloured cement to match the surface complete all as specified and directed. 47 Non skid colouredceramic tiles area of each tile exc. 0.11 sqm but n.exc. 0.18 sqm 7mm to 8mm mm thick as in floor finishesset and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM(1:4) incl skirting complete all as per specified. 48 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 49 Brass chromium plated towelring round 200mm dia, fixed in repairs, complete all as specified and as directed. 50 20mm dia brass chromium plated tubular towel rails, D type,60 cm long between flanges, fixed in repair, complete all as specified and as directed. 51 Glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and as directed. 52 Single lever wall mixer 3 in 1, with provn of over head shower & hand shower, telephonic type, brass, chromium plated,fancy type, with capstan head handles with lettered hot and cold, screwed down high pressure, including CP brass wall flanges and necessary extension nipples screwed for 15mm bore pipe connection, with provision for both hand shower and over head shower, fixed in repair, complete all as specified and directed. 53 Centre hole mixer for mixing hot & cold water for wash hand basin, cast copper alloy, with dual capstan heads, chromium plated, screwed down high pressure, with lettered Hot & Cold with long screwed shanks and fly-nuts, screwed for iron pipe suitable for 15mm bore, fixed in repair complete all as specified and directed. 54 Shower rose, brass, chromium plated, with CP arm 120mm dia with or without swivel joint, with & including CP brass arm and wall flange, fixing to steel pipe or union as in repair complete all as specified and directed. 55 Angle valve, brass, chromium plated, fancy type,with capstan head handle screwed down high pressure, including CP brass wall flanges; screwed for 15mm bore pipe connection fixed in repairs complete all as specified and directed. 56 Bib taps, brass, chromium plated, fancy type,long nose, with capstan head handle screwed down high pressure, including CP brass wall flanges; screwed for 15mm bore pipe connection fixed in repairs complete all as specified and directed. 57 Stop valves, but fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repairs complete all as specified and directed. 58 600mmx450mm beveled edge mirror 5.5mm thick of selected quality glass, mounted on 6mm thickcommercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, fixing in repairs, complete all as specified and directed. 59 PVC flexible connections 450mm long 15mm dia with brass flange nuts & washers complete all as specified & directed. 60 PVC flexible connections 600mm long 15mm dia with brass flange nuts & washers complete all as specified & directed. 61 Soap dish, brass, chromium plated, heavy duty, fixed to wall with plugs with brass cromium plated screws, fixed in repair complete all as specified and directed. 62 CP brass grating 100mm dia, centre hole, fixed in repairs complete all as specified and asdirected. 63 CP brass grating 100mm dia, fixed in repair scomplete all as specified and asdirected. 64 10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, fixed in repairs, complete all as specified and as directed. 65 Vitreous china water closet, Orissa pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including connection to trap, anti syphonage pipe etc. complete fixed in repairs, complete all as specified and as directed. 66 Wash down water closet (Pedestal pattern), complete with Pedestal pan and P trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc.including PVC Seat and cover for pedestal pan and CP Jet alongwith flexible tube/pipe complete all as specified and directed. 67 Vitreous china wash hand basin white flat back size 580x450mm including waste chain and plug and porcelain stopper but inclbracket CP waste coupling & waste pipe fixed in repairs complete all as specified and directed. 68 Vitreous China urinals, half style type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)fixed in repairs including all the accessories required for urinal complete all as specified and directed. 69 75mm th PCC 1:3:6 type C-2 as in plinth protection with 6 x 10mm groove in every 3m and filled with bitumen mastic filling, finished even and fair complete all as specified and directed. 70 25mm thick cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in floor and finished even and rough to receive tiles without using extra cement complete all as specified and directed. 71 4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed. 72 4 mm thick figured glass, pin head type and glazing with oil putty in squares in exc 0.5 sq.m in each pane complete all as specified and directed. 73 Preparation of new plastered surfaces of wall by applying 1 to 1.2mm thick Altek/Birla white putty to obtain smooth/even finish using sand paper and applying two coats of distemper oil emulsioncomplete all as specified and directed. 74 M & L two coat of cement base paint over a coat of alkali resistant primer paint including preparation of newly plastered surfaces of wall upto 7m height from ground level and at all locations as directed including scaffolding, cleaning and curing etc. complete all as specified and directed. 75 Complete removal of existing treatmentof old plastered surfaces of wall andapplying 1 to 1.2mm thick Altek/Birla white putty to obtain smooth/even finish using sand paper and applying two coats of distemper oil emulsioncomplete all as specified and directed. 76 Two coat of cement base paint over a coat of alkali resistant primer paint including complete removal of existing treatment of old plastered surfaces of wall upto 7m height from ground level and at all locations as directed including scaffolding, cleaning and curing etc. complete as directed. 77 Preparation of new plastered surfaces of ceiling and applying three coat of white wash, complete all as specified and directed. 78 200mm long, aluminium anodised, barrel tower bolts (ISI Marked) of extruded section and fixed, complete all as specified and directed. 79 300 mm long aluminium alloy, anodised, sliding door bolt (ISI Marked) with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed. 80 150 mm aluminium handles, cast type anodised complete all as specified and directed.(ISI Mark) 81 300 mm long mild steel ordinary rat tail rod pattern door spring including roller and roller plate, fixed to frame, complete all as specified and as directed. 82 Floor door stopper of aluminium power coated alloy long body(as per sample kept in GEs office) and tongue, anodised, with hard drawn steel spring, fixed in floor, 140mm overall length of cover plate complete all as specified and directed.(ISI Mark) 83 100mm long, stainless steel butt hinges for PVC door, complete all as specified and directed. 84 Continuous (piano) hinges width of flaps 30 mm when opened, mild steel, bright finish or electrogalvanised complete all as specified and as directed. 85 Hasp and staple, 125 mm size safety type aluminium anodised with mild steel hinges pin, including bolt to hinge plate and fixed with screws, complete all as specified and as directed. 86 100 mm aluminium handles, cast type anodised complete all as specified and directed.(ISI Mark) 87 Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) asin surface channels and drains, complete, complete all as specified and as directed. 88 Plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in steps, seismic and other similar bands, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, cills, lintels upto 1.50 metre clear span, copings etc. and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form works, complete, all as specified and directed. 89 25 mm dia stainless steel curtain rod, decorative, including brackets, decorative finials at both ends fixed in repairs, completeall as speccified and directed. 90 Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings incl ridges, all as directed complete all as specified and directed. 91 Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed. 92 Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed. 93 Chromium plated , water jets to EWCswith flexible pipe, suitable for 15mm bore of pipe and making connections, fixed in repair complete all as specified and directed. 94 PVC (SWR) pipes single socketed in any length with rubber ring, joints, fixed to walls in repairs 110mm borecomplete all as per specified and directed. 95 PVC (SWR) bends in any radius 110mm bore in repairs complete all as spd and directed. 96 PCC 1:5:10 type E2 (40mm graded stone aggregate) in mass concrete for lean concrete of WC/ Bath complete all as per specified and directed. 97 Vitreous china wash down water closet pan `P` or `S` trap ( pedestal pattern ) white including fixing bolts,including connection to drain pipe ( or out going pipe) and to flushing pipe,antisyphonage pipe etc fixed in repairs complete all as per specified and directed. 98 Dismantling wall and ceiling boards, fibre pulp insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets, stuctural steel frame, etc all as specified. 99 Providing & fixing tiled false ceiling ofDesigner tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizental level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos T of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main T at 600 mm c/c toform a grid of 1200x600mm and secondary cross T of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mmand laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200mm c/c along main T, bottom exposed width of 15mm of all T sections of 3mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, all complete at all heights as per direction of Engineer-in-Charge. 100 Taking down chowkats or frameswith shutters(without taking offshutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt. ) , all as specified and directed. 101 Description all as per item No. 100 above but area exceeding 1.50 square metre and not exceeding 4 square metre each. 102 Demolition of cement concrete of any description and in anypositionnot otherwise specifically provided for complete all as specified and directed. 103 PCC 1:3:6 type C-2 using 40mm graded aggregate 100mm thick as in path complete all as specified and directed. 104 Rolled mild steel in roof trusses (framed) , trussed , purlins,crane gantries , rails and fastening and heavy bracket framing ( beam, tee, angle, channel or flat section) including distance pieces conforming to Fe 410-W, Gde E-250 Quality A, complete all as specified and as directed. 105 Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all asspecified and directed. 106 Brick work with old size sub class B bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, complete all as specified and as directed. 107 Description all as per item No. 106 above but except brick. 108 Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortor 1:4 complete all as specified and as directed. 109 Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out in any type of soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface, complete all as specified and as directed. 110 Providing cement concrete in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, 1:2:4 mix type B-0 complete all as specified and as directed. 111 Mild steel work for vehicle sheds framed brackets of angles, tees or channels with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates,rivetting, etc.,conforming to FE 410-0 or FE 310-0 complete all as specified and as directed. 112 Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling,floors etc to match the existing, complete all as specified and as directed. 113 Dismantling and taking down fluorescent tube light single/double of any wattage or size street light fittings for repair or replacement of burnt/worn out accessories or carrying to MES store (Accessories or components to be provided free for replacement by department) complete all as specified and as directed. 114 Taking downunservicable/ servicable MCB DBs/AC box to deposite instore for keeping in safe custody for re-use or for taking in schedule of credit of any size/rating, complete all as specified and directed. 115 Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductorwiring in and including PVC concealed conduit (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light / fan controlled by one switch with 1.25mm thick pressed GI terminal boxes (modular type) of required modules concealed on walls including inner and outer sheet for fixing of modular switches/socket/regulator etc along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, completeall as specified & directed. 116 Description all as per item No 115 above but for exhaust fan point controlled by one way switch. 117 Description all as per itemNo 115 above but 05 Amp socket outlet controlled by one switch on independent board . 118 Description all as per itemNo 115 above but 05 Amp socket outlet controlled by one switch on same board with other switch. 119 Description all as per item No 115 above but for light point controlled by 2-two way switch. 120 Point wiring with 1.5 Sq. mm PVC Insulated unsheathed FRLS multistranded copper conductor, medium grade ISI marked drawn into and including PVC concealed conduit with all accessories from terminal box to junction of ceiling and wall and rest of circuit conductor wire drawn in to and including suraface PVC rigid non metalic conduit for one ceiling fan point controlled by one switch with and also including 1.5 sqmm continious earth wire connected to common earth dolly complete all as specified and directed. 121 M&L for point wring for power point controlled by one switch with 2.5 sqmm (nominal area) PVC insulated and PVC unsheathed multi stranded copper conductor cable FRLS in and including concealed PVC conduit 25 mm dia medium duty ISI marked, including sutiable new steel sunken boxes,modular frame and cover plate for fixing of modular switches as per required point in thatsame board, flush to surface for one light point, fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 2.5 sqmm copper conductor cable FRLS connected to common earth dolly complete all as specified and directed. 122 Supply and fixing in replacement of modular switch single pole one way 10Amps 1 module complete all as specified and directed. 123 Supply and fixing inreplacement0f modular switch single pole one way 16 Amps 1 module complete all as specified and directed. 124 M&L for modular Switch, single pole, two way, 10 Amp 240 Volts with polycarbonate body, complete all as specified and as directed. 125 Supply and fixing in replacement of modular socket 6 amp-2/3 pin combined 2module complete all as specified and directed. 126 Supply and fixing in replacement of modular socket 6 /16 Amps 2/3 pinCombined2 module complete all as Specified and directed 127 Ceilling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed. 128 Stepped type fan regulator 120W, 230V 50 C/S, 2 module, Deluxe Modular type electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically,fixed in repair,complete all as specified and as directed. 129 Fixing only Slim linear LED lighting fixture 20/10/5W watt LED batten for mirror light complete all as per the direction. 130 S&F in replacement of Slim linear LED lighting fixture 20 watt LED batten, with full base of extruded aluminium body section acting as a heat sink with closed back, isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVCinsulated 2 core flexible cable with flexible PVC pipefrom ceiling rose to fittings complete all as per the directed. 131 S&F in replacement of E-Lite LED Curve lighting fixture2 feet,10 watt LED batten, with full base of extruded polycarbonate body environmental friendly, energy efficient ready to use pack with isolated driver,complete making all connection using 1.5 sqmm copper conductor multistrandard PVCinsulated 2 core flexible cable with flexible PVC pipefrom ceiling rose to fittings complete all as specified and as directed. 132 S&F in replacement of E-Lite LED Curve lighting fixture 05 watt LED batten(mirror light+table light), with full base of extruded polycarbonate body environmental friendly, energy efficient ready to use pack with isolated driver,complete making all connection using 1.5 sqmm copper conductor multistrandard PVCinsulated 2 core flexible cable with flexible PVC pipefrom ceiling rose to fittings complete all as specified and as directed. 133 S&F in replacement of security (street) light fitting 35 watt,230 volts new generation energy saving & environmental friendly long life versatile pressure die costaluminium IP 66 with acylic, powder coated, pressure die cast aluminium compact high power LED street light with heat resistant toughed glass, corrosion resistant, isolated driver,including provision of GI tubing bracket of suitable size and fixed on wall including clamps, nut, bolts and washer for fixing of security (street) light complete all as specified and as directed. 134 S&F in replacement of 2 X 2 ceiling mounting LED warm/white light fitting Vector series tiles allow you to create beautiful pattern on your ceiling. Seamless integration with ceiling, easy maintenance,high system efficacy makes it a hassle free choice for office spaces.alonwith 3 CCT options & convert your ceiling into a beautiful piece of art. Product image with illustration of 4 is shown for reference suitable for Armstrong /grid /ceiling all as specified and directed. 135 Sub main wiring with tworuns of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLSPVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid conduit 25mm dia ISI marked with all conduit accessories mounting on suface of walls /roofs / ceilingetc with one run of 6 Sqmm (1x6sqmm ) single core FRLS PVC insulated unsheathedcopper conductor cable as earth wire, fixed in repair, complete all as specified and directed. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit. 136 Sub main wiring with tworuns of 4 Sqmm ( 2x4 sqmm ) 1100 volts grade single core FRLSPVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25mm dia ISI marked with all conduit accessories mounting on suface of walls /roofs / ceilingetc with one run of 4 Sqmm (1x4sqmm ) single core FRLS PVC insulated unsheathedcopper conductor cable as earth wire, complete all as specified and directed. Note:- 2 runs of 4 Sqmm (2x4sqmm ) ,one run of 4 Sqmm (1x4 sqmm ) cable and one metre of conduit will be measured as one unit. 137 Sub main wiring with fourruns of 6 Sqmm ( 4x6 sqmm ) 1100 volts grade single core FRLSPVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid conduit 25mm dia ISI marked with all conduit accessories mounting on suface of walls /roofs / ceilingetc with one run of 6 Sqmm (1x6sqmm ) single core FRLS PVC insulated unsheathedcopper conductor cable as earth wire, fixed in repair, complete all as specified and directed. Note:- 4 runs of 6 Sqmm (4x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit. 138 Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, connected to and including4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :-(a) Excavation and earth work for drilling hole for electrodein any type of soil.(b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC coverwith suitablehandle 40 mm thickinPCC1:2:4type B-1,reinforced with welded steel wirefabric weighing notless than 1.87 Kg/Sqm.(d) Funnel with watering pipe of GI20 mm nominal bore medium grade and copper lugs etc all as specified. 139 Srl item No 138 Contd …(e) 15 mm nominal bore light grade GI protection pipe 7.5 mtrlongforprotectionof earthing lead from mechanical injury or tempering.(f) Requisite quantity of common salt and charcoal.(g) Testing of earthing.Note : On testing after completionof earthing, ifthe desired earth resistanceisnotobtained,theearthingwill bere-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. 140 Supply and fixing in replacement of Exhaust fans steel body,AC ingle phasee 230 volts of size 300 mm sweep with blades and frame and louver complete all as specified and directed. 141 Supply & fixingin replacement of ceiling fanscomplete withblades,down rods electronic regulators andaccessories 230 V,1200 mm sweep.Min air delivery 210CFM with service value 6.00 BEE 5 star rated withbrush less direct current motor(BLDC) complete all as specified and directed. 142 Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar,double door typeincluding cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed. 143 S&F in replacement of C series miniaturee circuit breaker (MCB) of following pole and current carrying capacity in the DB complete with connection testing and commissioning.SPN MCB 40 to 63 Amps 240V ,50Hz,10kA lighting and other domestic loads incl all termnials, fitting etc. complete all as specified and as directed. 144 S&F in replacement of miniaturee circuit breaker (MCB) of following pole and current carrying capacity in the DB complete with connection testing and commissioning.SP MCB06 to 32 Amps 240V ,50Hz,10kA, C siriessuitable for lighting and other domestic loads incl all termnials, fitting etc. complete all as specified and as directed. 145 S & Fin replacement of sheetmetal VTPN DB - DPX3 160 MCCB DBs 04way (Optimum + 12) with metaldoor415voltsgrade IP 43 Protection Grade fixed flush to wall complete including connections should be provide with necessary reducer lugs complete all as specified and as directed. 146 Taking down ceiling fan/exhaust fan,sealing cable end etc and shifting to store complete and rehanging the same after overhauling and painting with white synthetic enamel paint (two coat) with the help of spray gun and connecting with three core flexible copper conductor cable 1.0 sq mm complete all as specified and as directed. 147 Supply and fix sheet metal enclosure Single pole & neutral with 2 pin and earth plug and socket 20Amps,240V complete with one single pole MCB of any cap from 5 to 32 Amps of breaking capacity 10KA, complete all as specified and as directed. 148 S & Fin replacement of DPX3 thermal magnetic MCCB 4 pole160 Amps415 Volts 16 ka INCLUDING MAKING NECESSARY ARRANGEMENT all as specified and directed by engineer in charge for MCCB DB. 149 S & F in replacement of DPX3 thermal magnetic MCCB 4 pole100 Amps415 Volts 16 ka INCLUDING MAKING NECESSARY ARRANGEMENT all as specified and directed by engineer in charge for MCCB DB. 150 Sheet metal enclosures for distribution board when MCB to be used SPN 8 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar,double door typeincluding cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed. 151 Supply and fix electric water heater, storage type steel body with steel inner tank and heating element up to 2 KW capacity 25 litters, BEE 5 star rated complete with all accessories such as safety valve,thermostate, NRV,connection piece etc. complete all as specified and as directed. 152 Taking down the existing geyser of any capacity carefully and shifting to the MES store yard and re-fixing the same after completion of B/R works including all connected accessories directed. 153 Supply, laying and testing of XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 35 sqmm 4 core including taking up/down old unserviceable cables. complete all as specified and as directed. 154 GI tubing light grade with all fitting and fixed in wall and floor or fixed to pole of size 40mm dia complete all as specified and as directed. 155 M&L for on load change over switch 100 Amps 4 pole 415 V in sheet metal enclosure 4 polecomplete all as specified and as directed. 156 GI tubing light grade 40mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles,complete all as specified and as directed. 157 Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth in any type of soil and getting out soil, complete all as specified and as directed. 158 Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness shall be measured for payment purpose. 159 Sub class ‘B’ old sizewell burnt bricks, laid flat in trenches as protection to cable complete all as specified and as directed. 160 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed. 161 Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil,complete all as specified and as directed.

Key Value

Document Fees
INR 1000 /-
EMD
INR 174000.0 /-
Tender Value
INR 99.33 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB