Tender For Providing/Fixing Of Galvalume Profile Sheet (Shed) In Mess Of Hostel 1, 8 & Aravali Hostel At Mnit Campus Jaipur.; 1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. DSR No. 2.8 2 All kinds of soilDSR No. 2.8.1 3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : DSR No. 4.1 4 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR No. 4.1.2 5 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.DSR No. 10.16 6 Hot finished welded type tubesDSR No. 10.16.1 7 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. DSR No. 12.50 8 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. DSR No. 12.50 9 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : DSR No. 13.61 10 Two or more coats on new workDSR No. 13.61.1 11 Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge DSR No. 16.68 12 Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge DSR 16.68 13 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: DSR No. 6.1 14 Cement mortar 1:6 (1 cement : 6 coarse sand)DSR No. 6.1.2 15 12 mm cement plaster of mix :DSR No. 13.1 16 1:6 (1 cement: 6 fine sand)DSR No. 13.1.2 17 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.DSR No. 1.10 18 Group B DSR No. 1.10.2 19 Supplying and drawing following sizes of FRLS/HFFRPVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit asrequired. 20 2 x 2.5 sq. mmDSR No. 1.17.11 21 Supplying and fixing following modular switch/ socketon the existing modular plate & switch box includingconnections but excluding modular plate etc. asrequired. 22 5/6 A switchDSR No. 1.24.1 23 pin 5/6 A socket outlet DSR No. 1.24.4.3 24 Supplying and fixing two module stepped typeelectronic fan regulator on the existing modular plateswitch box including connections but excludingmodular plate etc. as required.DSR No. 1.25 25 Supplying and fixing two module stepped typeelectronic fan regulator on the existing modular plateswitch box including connections but excludingmodular plate etc. as required.DSR No. 1.25 26 Supplying,installation,Testing&Commissioningof Panel light 2x2 ft., of following body material and construction as per IS : 10322 withdriver as per the requirementwith Driver efficiency >85%,Operating voltageAC140-270Volt, frequency 50/60hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95,IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver &electricalcircuitry),ofminimum50000Burning Hourswith,70%ofinitial Lumen maintained till lifeends as per LM80 extrapolation IES TM-21-11 report,CCT3000°K/4000°K/5700°K/6500°K(AsperANSIBin),SDCM(Standard DeviationColour Matching) <3,Maximum power consumption shouldnotmorethan the specified rating and Fixture shall be ofrelevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/Screenprintingonhousing.complete in all respect i/c externalconnections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductorsinglecorecableandearthingetc.as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report andalltestingrequired forLEDfixturesasperBISshallbesubmitted. Shape size and CCT shall be as approved by Engineer-in-Chargeasperrequirement.(Thermal management:heatsinkofaluminiumhousing suchthatLEDjunctiontemperatureshallnotrise above 90°C).Powdercoateddiecast/Extrudedaluminium Body (Thickness > 1.20 mm)DSR No. 8.6 27 15 watt DSR No. 8.6.1 28 Supply, Installation, Testing and Commissioning ofceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. metal( Aluminiumalloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value63 DELHI SCHEDULE OF RATES (E&M)-2025(CM/M/W) minimum as below, 350 RPM (tolerance asper IS : 374-2019), THD (Total Harmonic Distortion)less than 10%, suitable for operation with regulatorfor speed control and all remaining accessoriesincluding safety pin, nut bolts, washers, temperaturerise=75 0C (max.), insulation resistance more than 2mega ohm, suitable for 230 V, 50 Hz, single phase ACsupply, Ceiling Fan compliant to IS 374:2019 fan i/cexternal connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cableand earthing etc. as required.DSR No. 9.2 29 1050mm, service value ≥ 5.1 CM/Min/Watt, airdelivery 150 CM/Min (Minimum)DSR No. 9.2.2