}

Tender For Maintenance Of Various Schemes Under Nazul A/C-Ii(East Zone).Sh: Repairing & Replacement Of Defective Electrical Wiring & Misc. Works At Various Community Hall In East Zone., Delhi-Delhi

Tender Notice

51828537
Corrigendum : Tender For Maintenance Of Various Schemes Under Nazul A/C-Ii(East Zone).Sh: Repairing & Replacement Of Defective Electrical Wiring & Misc. Works At Various Community Hall In East Zone.
Tender
Indian
Delhi
Delhi
30-10-2025

Tender Details

Tender For Maintenance Of Various Schemes Under Nazul A/C-Ii(East Zone).Sh: Repairing & Replacement Of Defective Electrical Wiring & Misc. Works At Various Community Hall In East Zone.; 1 1.0)Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 2 Group C 3 2.0) Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 4 2.1) 200 mm X 250 mm X 75 mm deep 5 2.2)75 mm X 75 mm X 60 mm deep 6 2.3) 200 mm X 125 mm X 60 mm deep 7 2.4)100 mm X 100 mm X 60 mm deep 8 3.0)Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 9 3.1) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 10 3.2)2 X 4 sq. mm + 1 X 4 sq. mm earth wire 11 4.0)Supply and installation of fan regulator switch in the existing electric board i/c connection, testing etc. as required. 12 5.0) Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 13 5.1)5/6 A switch 14 5.2)15/16 A switch 15 5.3) 3 pin 5/6 A socket outlet 16 5.4) 6 pin 15/16 A socket outlet 17 6.0) Supplying & fixing following way, single pole & neutral, sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing testing & commissioning etc. as required.(But without MCB/RCCB/Isolator) 18 6.1) 8way , Double door 19 6.2)12 way , Double door 20 7.0)Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. 21 7.1) 8 way (4+24), Double door 22 8.0)Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 23 8.1)Single pole 24 8.2)Double pole 25 9.0)Supplying and fixing following rating, souble pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 26 9.1)40 A 27 9.2) 63A 28 10.0) Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 29 11.0) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initialLumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trademark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm 30 11.1)18- 22 watt 31 11.2)40 watt 32 12.0) Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum 33 13.0)Replacement & Installation of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitablefor 230 V, 50 Hz,i/c Testing and Commissioning single phase AC Supply, earthing etc. complete as required. 34 14.0) Replacement & installation of exhaust fan(metallic body) ofsize 300 mm or 12 i/c connections,making good the damages ,iron angle & painting with screws,nuts & bolts with testing & commissioning etc. complete as required. 35 15.0) Replacement & installation of exhaust fan(metallic body) ofsize 450 mm or 18 i/c connections,making good the damages ,iron angle & painting with screws,nuts & bolts with testing & commissioning etc. complete as required. 36 16.0) Supplying & installation of Turbo force wall fan (metallic body) of 450 mm sweep having 1440 RPM with screws,nuts & bolts with testing & commissioning etc. complete as required.[as perlist price ofM/s Havells i.e. exclusive of GST.] 37 17.0)Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 38 17.1) 20 mm 39 17.2) 25 mm 40 18.0) Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required. 41 19.0)Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 42 20.0)Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 43 21.0) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in recessed steel/ PVC conduit as required. the existing surface 44 21.1) 1 x 1.5 sq. mm 45 21.2)3 x 1.5 sq. mm 46 21.3)6 x 1.5 sq. mm 47 22.0) Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. 48 22.1) 125 A,36KA,FPMCCB 49 22.2) 250 A,36KA,FPMCCB 50 23.0) Supplying and fixing of following sizes of steel conduit alongwith accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 51 23.1)20 mm 52 23.2) 25 mm 53 24.0)Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. 54 24.1)For8 way, Double door SPN MCBDB 55 24.2) For 14 way, Double door SPN MCBDB 56 25.0) Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. 57 26.0)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) 135 lm/Watt 1.17 DELHI SCHEDULE OF RATES (E&M) Volume-II 2025 15 output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C 58 26.1) 70 watt 59 26.2) 100 watt 60 27.0)Supply of 3C X 6 Sq.mm. size of 1.1 KV grade multicore aluminium conductor XLPE insulated and PVC sheathed armoured cable as per IS : 7098:1988 with upto date amendments. 61 28.0) Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) 62 29.0)Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 23-10-2025 Due to administrative reason Date 30-10-2025

Key Value

Document Fees
Refer document
Tender Value
INR 28.38 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail