Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | A. C/o TY-II Quarters 2 Blocks (1 Block = 6 Unit) |
| 2 | SH : I : EARTH WORK. |
| 3 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 4 | Extra for every additional lift of 1.50 m or part thereof for earth work in all soils including shingles, small size boulders upto 30 cm size but excluding saturated soil and rock. |
| 5 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 6 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 7 | Providing and laying Boulder filling |
| 8 | SH :- II:CEMENT CONCRETE WORK. |
| 9 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth |
| 10 | SH : III:R.C.C.WORK |
| 11 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;using coarse aggregate and fine aggregate derived from natural sources,portland Pozzolana/Ordinary Portland/Portland Slag cement,admixtures in recommended proprtions as per IS:9103 to accelerate/retard setting of concret,to improve durability and workability without imparing strenght:including pumping of concrete to site of laying,curing,carriage for all leads:but excluding the cost of centuring,centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge:for the following grades of concrete. |
| 12 | All work upto plint levela) Concrete of M25 grade with minimum cement content of 330kg/cum |
| 13 | All work above plinth level upto V leveld) Concrete of M25 grade with minimum cement content of 330kg/cum |
| 14 | Centring and shuttering including strutting, propping etc and removal of form work for :a)Foundation, footings, bases of columns etc. and mass concrete. |
| 15 | b)Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 16 | c)Columns, pillars, posts and struts etc. |
| 17 | d)Lintels, beams, girders, bressumers and cantilevers etc. |
| 18 | e)Suspended floors, roofs, landings shelves and their supports balconies and chajjas (3.5m height). |
| 19 | f)Stairs (excluding landing) except spiral stair cases. |
| 20 | g)Vertical and horizontal fins individually or forming box louvers bands and facias |
| 21 | Reinforcement of RCC work including bending, binding and placing in position complete.a) Tar/TMT steel |
| 22 | SH : IV: BRICK WORK. |
| 23 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
| 24 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 25 | Extra for brick work in superstructure above floor two level, per floor per Cu.m. (1% of rate of brickwork from plinth up to floor two level). |
| 26 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 27 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 28 | Extra for half brick masonary in superstructure above floor two level. |
| 29 | SH : V : WOOD WORK |
| 30 | Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position. |
| 31 | Supplying and fixing factory made panelled shutters made out of best available hard wood for doors including panelling with panels 12 mm thick commercial veneered teak wood particle boards (Phenyle Bonded) 3 layers flat pressed including applying one coat of approved wood primer.a) 40 mm thick including anodized aluminum butt hinges with necessary screws. |
| 32 | Providing and fixing factory made uPVC door shutters, decorative typeincluding door frame, with necessary screws and all fittings as per the direction of Engneer-in-charge. |
| 33 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 34 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.b) Ornamental grill. |
| 35 | Providing and fixing aluminum butt hinges anodised, transparent or dyed to required color or shade with necessary screws etc complete.a) 100 x 75 x 4 mm |
| 36 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete.a)300 x 10 mm |
| 37 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.a)125 mm |
| 38 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a)300 x 16 mm |
| 39 | SH : VI : STEEL WORK. |
| 40 | Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete. |
| 41 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.a) In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 42 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 43 | Providing and fixing 12 mm thick and 100 mm wide pelmet with 25 mm dia ss curtain rod and brackets including fixing with 25 x 3 mm MS flat 10 cm long and plugs etc complete. |
| 44 | SH:VII:ALUMINIUM WORK |
| 45 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) :For fixed portion.1.3. Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 46 | For shutters of doors, windows & ventilators including providing and fixing hinges /pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately).2.3) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron). |
| 47 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item)4.1) With float glass panes of 4.0 mm thickness. |
| 48 | SH:VIII:FLOORING |
| 49 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.a)Size of Tile 600x600 mm |
| 50 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., completea) Size of Tile 600x600 mm |
| 51 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels(a) Granite stone slab of colour black, Cherry/Ruby red 18 mm thick (slab area upto 0.50 sqm) |
| 52 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.a) Marble work |
| 53 | Providing and laying matt finished vitrified tile of size 100x100x16mm having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in out door floors such as footpath, court yard multi models etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as direction of Engineer-in-Charge.Tiles for Parking |
| 54 | SH : IX : FINISHING |
| 55 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 56 | 6 mm cement plaster to ceiling 1 : 4 (1 cement : 4 fine sand). |
| 57 | Providing two coats of acrylic water based wall putty/ wall filler of Asian Paits/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the halp of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department. |
| 58 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 59 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 60 | Painting two coats with oil type wood preservative of approved brand and manufacture on new work. |
| 61 | Applying priming coat consisting of a mixture of red lead, white lead and double boiled linseed oil in the ratio of 0.7 Kg : 0.7 Kg : 1 Litre on wood work complete. |
| 62 | Applying priming coat of a mixture of red lead raw linseed oil and turpentine oil in the ratio of 2.80 Kg : 1 Litre : 1 Litre on steel work complete. |
| 63 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
| 64 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade. |
| 65 | SH:X:DRAINAGE |
| 66 | Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete. |
| 67 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 68 | SH:XI:ROOFING |
| 69 | Providing and fixing on wall face C.I. rain water pipe including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1 : 2 ( 1 cement : 2 fine sand).d)150 mm diameter pipe |
| 70 | Lime concrete terracing on roofs, average thickness 10 cm laid to fall with 25 mm gauge brick ballast and 50% mortar consisting of 1 lime putty and 2 surki finished with gur and belgiri treatment complete and covered with flat brick tiles grouted with cement mortar 1 : 3 (1 cement : 3 fine sand) over 12 mm layer cement mortar 1 : 3 (1 cement : 3 fine sand)and finished neat. |
| 71 | SH : XII: WATER SUPPLY. |
| 72 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.a) Concealed work, including cutting chases and making good the walls etc.i) 15 mm nominal outer dia Pipes |
| 73 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).a)20mm nominal bore. |
| 74 | Providing and fixing brass bib/pillar cock of Jaquar or equivalent quality.a)15mm nominal bore. |
| 75 | Providing and fixing brass stop cock of Jaquar or equivalent quality.a)15mm nominal bore. |
| 76 | Providing and fixing 3 in 1 Wall Mixer Tap of Jaquar or equivalent quality.a)15mm nominal bore. |
| 77 | Providing and fixing PVC connection pipe with brass union 30cm length.a)15mm nominal bore. |
| 78 | Providing and fixing CP brass shower rose with 15 mm or 20 mm dia inleta)150 mm dia |
| 79 | Painting G.I. pipes and fittings with white paint over a coat of ready mixed priming coat both of approved quality for new work.a)20mm nominal bore. |
| 80 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).a) 40 mm nominal bore |
| 81 | SH:XIII:SANITARY INSTALLATION |
| 82 | Providing and fixing white vitreous china type water closet pedestal (European type WC pan) with seat and lid CP brass hinges and rubber buffers, 12.5 Litres high level CI flushing cistern with fittings RS or CI brackets, galvanized steel telescopic flush pipe with fittings and clamps, 20 GI overflow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting making good the walls and floors where required.a) WC pan with white plastic seat and lid. |
| 83 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. a) Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality. |
| 84 | Providing and fixing 100 mm sand cast iron grating for gulley, floors or nahni trap |
| 85 | Providing and fixing CP Brass Chain and rubber plug complete for sink or wash basins. |
| 86 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 87 | Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard rail complete, fixed to wooden cleadts with CP brass screws. |
| 88 | Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality).a)750 x 20 mm |
| 89 | Providing and fixing toilet paper holder.a) CP Brass |
| 90 | Providing best available local wood 50 x 50 x 50 mm wood plugs including cutting brick work and fixing in cement mortar 1:3 (1 cement : 3 fine sand). |
| 91 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.a) 100 mm dia |
| 92 | Providing and fixing sand cast iron heel rest sanitary bend.b)75mm dia. |
| 93 | Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.b) 80 x 80 x 80 mm |
| 94 | Providing and fixing sand cast iron single equal plain junction of required degreeb) 80 x 80 x 80 mm |
| 95 | Providing and fixing sand cast iron trap of self cleadnsing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors.a)100mm inlet and 100mm outlet. |
| 96 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :a) Kitchen sink with drain board. i) 510x1040 mm bowl depth 250 mm |
| 97 | Providing and fixing health faucet (set) with metal tube of Jaquar/ equivalent quality. |
| 98 | Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design.a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg). |
| 99 | SH : XIV UNDERGROUND SUMP |
| 100 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 101 | Boulder Soling in foundation and plinth ramming, consolidating and dressing complete. |
| 102 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in :a) Foundations and plinth |
| 103 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 104 | Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in :a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size) |
| 105 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 106 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 107 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 108 | Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel |
| 109 | Centring and shuttering including strutting, propping etc and removal of form work fora)Foundation, footings, bases of columns etc. and mass concrete. |
| 110 | b)Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 111 | c)Columns, pillars, posts and struts etc. |
| 112 | d)Lintels, beams, girders, bressumers and cantilevers etc. |
| 113 | e)Suspended floors, roofs, landings shelves and their supports balconies and chajjas (3.5m height). |
| 114 | 12 mm cement plaster 1 : 3 (1 cement : 3 fine sand). |
| 115 | Neat cement punning. |
| 116 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 117 | Providing, Supplying, Testing & Commissioning of 2 Hp Electric Motor Pump for lifting of water |
| 118 | SH : XV SEPTIC TANK |
| 119 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 120 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Foundations and plinth |
| 121 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 122 | Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in :a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size) |
| 123 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 124 | Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel |
| 125 | Centring and shuttering including strutting, propping etc and removal of form work fora) Foundation, footings, bases of columns etc. and mass concrete. |
| 126 | b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 127 | c)Suspended floors, roofs, landing shelve and theirsupports, balconies and chajjas (3.50m height) |
| 128 | 12 mm cement plaster 1:3( 1 cement : 3 fine sand) |
| 129 | Neat cement punning. |
| 130 | Providing and fixing C.I manhole cover. |
| 131 | Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. a) 100 mm dia SW pipes |
| 132 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15cm thick as per standard design.a) 100 mm dia SW pipes |
| 133 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. |
| 134 | Providing and fixing sand cast iron single equal plain junction of required degreea) 100 x 100 x 100 mm |
| 135 | SH : XVI SOAK PIT |
| 136 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 137 | 2nd quality local brick honey-comb half brick work in cement mortar 1:4 (1 cement : 4 fine sand). |
| 138 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 139 | Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel |
| 140 | Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. a) 200 mm dia SW pipes |
| 141 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15cm thick as per standard design.a) 200 mm dia SW pipes |
| 142 | SH : XVIIFIRE FIGHTING SYSTEM |
| 143 | Supply, installation, testing and commissioning of single stage centrifugal type factory assembled fire pumps suitable for autometic operation at synchoronous speed of 2900 rpm, TEFC conforming to IP-55 & flexible coupling gaurd mounted on a common structural base plate with 150mm dia gun metal pressure gauges with isolation cock and piping, suitable vibration elimination pads of approved design for pump foundation, motor to be suitable for 415 volts, 3 phase 50 cycles AC.8hp Pump for Fire Hydrant Network. |
| 144 | Supply, installation, testing and commissioning of horizontal single stage centrifugal pumping set with CI volute and bronze impeller with mechanical seals directly coupled to automatic Diesel Engine complete with all accessories like self starting by means of Battery powered electric starter motor, Paper Filter type air cleaner, exhaust silencer etc. complete in allrespects.The engine & the pump will be mounted on common base plate on anti-vibration mountings.Diesel Pump for Fire Hydrant Network. |
| 145 | Supply, fabrication (as per code), installation, testing and commissioning of Pressure vessels 450mm diameter and 1000mm high fabricated from 8-10mm M.S. plate with accessories inside painting with epoxy paint and outside with enamel. |
| 146 | Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 8.8 Kg/cm2 and test pressure 14 Kg/cm2 for :-100 mm dia |
| 147 | Supply, installation, testing, trial run and commissioning of hydrants all complete as required and as approved.Providing and fixing angle iron (40 mm x 40 mm x 5 mm) MS door frame 900x2100 door capable of accommodating fire hose reel, landing valve, hose pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for making 900x600x2100 Recessed type mansoary box (by civil contractor). |
| 148 | 63mm dia single outlet GM landing valve IS marked with suitable size bolts, nuts, washers and gaskets. Landing valve shall be TAC Approved Make. |
| 149 | 63mm reinforced rubber hoses (RRL) with male and female GM coupling, IS marked- 15 m long. |
| 150 | Fire Axe |
| 151 | Providing, installing, testing & commisioning of fire brigade inlet connection (fire department connection) consisting of 4 Nos. 63 mm dia instantaneous inlet arranged on a 50 mm dia header, 1 No. 150 mm diameter Butterfly valve, 1 No. 150mm dia. Non-return valve and wall mountedbox of M.S. construction with glass door to house the above mentioned components. |
| 152 | Providing, installing, testing & commisioning of fire brigade draw out connection (fire department connection) with suction pipe MS class \"C\" 100 mm dia. & 100 mm dia. foot valve & steel chain including wall mounted box M.S. construction with glass door to house the above mentionedcomponenets. |
| 153 | Providing and fixing C.I.double acting air valves of approved quality with bolts, nuts, rubber insertions etc. complete ( The tail pieces, tapers etc. if reqd. will be paid separately)100 mm dia |
| 154 | Providing & Fixing C.I.sluice valve(with cap)complete with bolts, nuts, rubber insertions etc.(the tail pieces if required will be paid separately)100 mm dia.pipe (Class II) |
| 155 | NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.100 mm dia |
| 156 | Providing laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 1239/3589 (all pipes shall be ISI marked and of makes specified in the specifications) i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in groundincluding excavation & providing cement concrete blocks as supports and anti-corrosive treatment to burried pipes by wrapping & coating with 4 mm thk. (OR 2 COATS of 2mm thick tape) anticorrosion tape along with two coat of black japan primer for under-ground pipeincluding digging and backfilling upto 1.0 mtr. below from G.L.for external work as per IS-909 (Specification for Underground Fire Hydrant . (Under ground)100 nominal bore (class C) |
| 157 | Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats ofsynthetic enamel paint of required shade complete as per specificatipns and asrequired. (Above Ground)100 mm nominal bore (class C) |
| 158 | Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindrical body, internal discharge tube, discharge nozzle, suspension bracket, conforming toIS 2878, finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 4.5 kg |
| 159 | Fabricating, supplying, testing and commissioning of electrical control panel of 600X250X700mm size, free floor resting, fix type, single front, fabricated out of 16 SWG CRCA Sheet, noncompartmentallised dust and vermin proof, powder coated approved shade after 7 tank treatment process, cable alley interconnection, having switchgears and accessories mounting and internal wiring, earth terminals, numbering etc., complete in all respects, suitable for operation on 415V, 3 phase 50 Hz., AC supplywith enclosure protection class IP-42as required. INCOMER32A 3P 10kA, C-Curve MCB, Red Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, Yellow Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, Blue Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, 8 HP HYDRANT PUMP AC3: 22A AC1: 32A 3P Power Contactor, Coil: 240V AC, Aux. Contact: 1NO, Type: MNX 22,14-23A Thermal Overload Relay, Directly Operated, Direct Mounting on MNX 09-40, Type: MN 2, Red Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, Amber Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, Red Flush Head Push Button 22.5 mmGreen Flush Head Push Button 22.5 mm, 1NO Contact Block1NC Contact Block, 6A 1P 2Way Local - Remote/ Auto-Manual Switch with Center OFF, 60 Deg. Operation, 6A 1P 10kA, C-Curve MCB, DIESEL ENGINE PUMP CONTROL FEEDER32A 2P 10kA, C-Curve MCB, 10 AMP Battery Charger-24 V DC, AC Relay, DC Relay, 6A 1P 2Way Local - Remote/ Auto-Manual Switch with Center OFF, 60 Deg. Operation, Red Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, Amber Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, Red Flush Head Push Button 22.5 mm, Green Flush Head Push Button 22.5 mm, DC Voltmeter, 1Ph, Range : 200mV - 600V with Built-in Resistance, Accuracy Class : 1, Size : 96x96, Model: AE 82142, DC Ammeter, 1Ph, Range : 20mA to 5A Direct, Above 5A: External Shunt 50/60/75mV drop, Accuracy Class : 1, Size : 96x96, Model: AE 80142 |
| 160 | Supplying and Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure withcover platehavinglockingarrangementand watering pipe etc, with charcoal/ coke and salt as required. |
| 161 | Supplying and laying 25 mm x 5 mm.G.I. strip in 40 mm dia. G.I. Pipe from earth electrode, including connection with GI nut, bolt, spring, washer excavation and re-filling etc as required. |
| 162 | Providing & fixing 25mm x 5mm G.I. strip on surface or in recess forconnections etc. as required. |
| 163 | Providing and Fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing alongwith existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 164 | Laying and fixing of One number PVC Insulated and PVC Sheathed/XLPE power cable of 1.1 kV grade of size not exceeding 35 sqmm on surface as required. |
| 165 | Laying and fixing of One number PVC Insulated and PVC Sheathed/XLPE power cable of 1.1 kV grade of folloing size on wall surface as required. Aboved 35 sq mm and upto 95 sq mm (clamed with 25x3mm MS flat clam) |
| 166 | Supplying of all materials and making terminations of 1.1 KV grade aluminium multicore cables of the following sizes.The work includes cable glanding using brass plated double compression glands, sizing the core leads, removing insulation, fixing suitable crimping type copper lugs/ thimbles by using hydraulic crimping tools with correct size of the dies, shaping the leads and neatly connecting the same to the equipment terminals. 3.5 Core 120 sq. mm. Armoured Aluminium cable. |
| 167 | 3.5 Core 35 sq. mm. Armoured Aluminium cable. |
| 168 | 3.5 Core 16 sq. mm. Armoured Aluminium cable. |
| 169 | Control Cabling (PVC insulated and PVC sheathed, armoured, Copper Conductor of 1.1 KV grade on existing cable trays).5C x 1.5 Sq. mm |
| 170 | Carriage of the Material to Site |
| 171 | Yardstick for Furnishing of Residential Quarters |
| 172 | SUB HEAD-I( WIRING) |
| 173 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.\"Group \"A\" |
| 174 | Wiring for light / power plug with 2x4 mm² FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit along with 1 No 4 mm² FR PVC insulated copper conductor single core cable for loop earthing as required |
| 175 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire |
| 176 | 2 x 4.0 mm² + 1 x 4.0 mm² earth wire |
| 177 | 2x10 sqmm +1x 6.0 sq.mm earth wire |
| 178 | SUB-HEAD-II (PVC CONDUIT, METAL BOXES, SWITCHES & ACCESSORIES) |
| 179 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 180 | 40 mm |
| 181 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) |
| 182 | 3 Module (100mmX75mm) |
| 183 | 4 Module (125mmX75mm) |
| 184 | 6 Module (200mmX75mm) |
| 185 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A Switch |
| 186 | 15/16 A switch |
| 187 | 3 pin 5/6 amp socket outlet |
| 188 | 6 pin 15/16 amp socket outlet |
| 189 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 190 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 A TP&N |
| 191 | 200 A TP&N |
| 192 | 400 A TP&N |
| 193 | Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.400 A TPN |
| 194 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door |
| 195 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way , Double door |
| 196 | 8 way , Double door |
| 197 | 12 way , Double door |
| 198 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 199 | Single pole and neutral |
| 200 | Double pole and neutral |
| 201 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A |
| 202 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 203 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 204 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 205 | Supplying, Installation, testing and commissioning of LEDlamp.\"a) 9 Watt |
| 206 | b) 20 Watt |
| 207 | c) 40 Watt |
| 208 | Supplying and Providing of CelingfanHavells or other approved brand by Engineer-in-Charge |
| 209 | Supplying and Providing of exhaustfanHavells or other approved brand by Engineer-in-Charge |
| 210 | Supplying of Al. Thimble of following sizes :-35 sqmm |
| 211 | 95 sqmm |
| 212 | SUB-HEAD -III(EARTHING) |
| 213 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 214 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 215 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required |
| 216 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 217 | B. C/o TY-III Quarters 2 Blocks (1 Block = 6 Unit) |
| 218 | SH : I : EARTH WORK. |
| 219 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 220 | Extra for every additional lift of 1.50 m or part thereof for earth work in all soils including shingles, small size boulders upto 30 cm size but excluding saturated soil and rock. |
| 221 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 222 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 223 | Providing and laying Boulder filling |
| 224 | SH :- II:CEMENT CONCRETE WORK. |
| 225 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth |
| 226 | SH : III:R.C.C.WORK |
| 227 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;using coarse aggregate and fine aggregate derived from natural sources,portland Pozzolana/Ordinary Portland/Portland Slag cement,admixtures in recommended proprtions as per IS:9103 to accelerate/retard setting of concret,to improve durability and workability without imparing strenght:including pumping of concrete to site of laying,curing,carriage for all leads:but excluding the cost of centuring,centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge:for the following grades of concrete.All work upto plint levela) Concrete of M25 grade with minimum cement content of 330kg/cum |
| 228 | All work above plinth level upto V leveld) Concrete of M25 grade with minimum cement content of 330kg/cum |
| 229 | Centring and shuttering including strutting, propping etc and removal of form work for :a)Foundation, footings, bases of columns etc. and mass concrete. |
| 230 | b)Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 231 | c)Columns, pillars, posts and struts etc. |
| 232 | d)Lintels, beams, girders, bressumers and cantilevers etc. |
| 233 | e)Suspended floors, roofs, landings shelves and their supports balconies and chajjas (3.5m height). |
| 234 | f)Stairs (excluding landing) except spiral stair cases. |
| 235 | g) Vertical and horizontal fins individually or forming box louvers bands and facias |
| 236 | Reinforcement of RCC work including bending, binding and placing in position complete.a) Tar/TMT steel |
| 237 | SH : IV: BRICK WORK. |
| 238 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
| 239 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 240 | Extra for brick work in superstructure above floor two level, per floor per Cu.m. (1% of rate of brickwork from plinth up to floor two level). |
| 241 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 242 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 243 | Extra for half brick masonary in superstructure above floor two level. |
| 244 | SH : V : WOOD WORK |
| 245 | Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position. |
| 246 | Supplying and fixing factory made panelled shutters made out of best available hard wood for doors including panelling with panels 12 mm thick commercial veneered teak wood particle boards (Phenyle Bonded) 3 layers flat pressed including applying one coat of approved wood primer.a) 40 mm thick including anodized aluminum butt hinges with necessary screws. |
| 247 | Providing and fixing factory made uPVC door shutters, decorative typeincluding door frame, with necessary screws and all fittings as per the direction of Engneer-in-charge. |
| 248 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 249 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.b) Ornamental grill. |
| 250 | Providing and fixing aluminum butt hinges anodised, transparent or dyed to required color or shade with necessary screws etc complete.a) 100 x 75 x 4 mm |
| 251 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete.a)300 x 10 mm |
| 252 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.a)125 mm |
| 253 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a)300 x 16 mm |
| 254 | SH : VI : STEEL WORK. |
| 255 | Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete. |
| 256 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.a) In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 257 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 258 | Providing and fixing 12 mm thick and 100 mm wide pelmet with 25 mm dia ss curtain rod and brackets including fixing with 25 x 3 mm MS flat 10 cm long and plugs etc complete. |
| 259 | SH:VII:ALUMINIUM WORK |
| 260 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) :For fixed portion.1.3. Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 261 | For shutters of doors, windows & ventilators including providing and fixing hinges /pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately).2.3) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron). |
| 262 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item)4.1) With float glass panes of 4.0 mm thickness. |
| 263 | SH:VIII:FLOORING |
| 264 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.a)Size of Tile 600x600 mm |
| 265 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., completea)Size of Tile 600x600 mm |
| 266 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.(a) Granite stone slab of colour black, Cherry/Ruby red 18 mm thick (slab area upto 0.50 sqm) |
| 267 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.a) Marble work |
| 268 | Providing and laying matt finished vitrified tile of size 100x100x16mm having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in out door floors such as footpath, court yard multi models etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as direction of Engineer-in-Charge.Tiles for Parking |
| 269 | SH : IX : FINISHING |
| 270 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 271 | 6 mm cement plaster to ceiling 1 : 4 (1 cement : 4 fine sand). |
| 272 | Providing two coats of acrylic water based wall putty/ wall filler of Asian Paits/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the halp of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department. |
| 273 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 274 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 275 | Painting two coats with oil type wood preservative of approved brand and manufacture on new work. |
| 276 | Applying priming coat consisting of a mixture of red lead, white lead and double boiled linseed oil in the ratio of 0.7 Kg : 0.7 Kg : 1 Litre on wood work complete. |
| 277 | Applying priming coat of a mixture of red lead raw linseed oil and turpentine oil in the ratio of 2.80 Kg : 1 Litre : 1 Litre on steel work complete. |
| 278 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
| 279 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade. |
| 280 | SH:X:DRAINAGE |
| 281 | Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete. |
| 282 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 283 | SH:XI:ROOFING |
| 284 | Providing and fixing on wall face C.I. rain water pipe including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1 : 2 ( 1 cement : 2 fine sand).d)150 mm diameter pipe |
| 285 | Lime concrete terracing on roofs, average thickness 10 cm laid to fall with 25 mm gauge brick ballast and 50% mortar consisting of 1 lime putty and 2 surki finished with gur and belgiri treatment complete and covered with flat brick tiles grouted with cement mortar 1 : 3 (1 cement : 3 fine sand) over 12 mm layer cement mortar 1 : 3 (1 cement : 3 fine sand)and finished neat. |
| 286 | SH : XII: WATER SUPPLY. |
| 287 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.a) Concealed work, including cutting chases and making good the walls etc.i) 15 mm nominal outer dia Pipes |
| 288 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).a)20mm nominal bore. |
| 289 | Providing and fixing brass bib/pillar cock of Jaquar or equivalent quality.a)15mm nominal bore. |
| 290 | Providing and fixing brass stop cock of Jaquar or equivalent quality.a)15mm nominal bore. |
| 291 | Providing and fixing 3 in 1 Wall Mixer Tap of Jaquar or equivalent quality.a)15mm nominal bore. |
| 292 | Providing and fixing PVC connection pipe with brass union 30cm length.a)15mm nominal bore. |
| 293 | Providing and fixing CP brass shower rose with 15 mm or 20 mm dia inleta)150 mm dia |
| 294 | Painting G.I. pipes and fittings with white paint over a coat of ready mixed priming coat both of approved quality for new work.a)20mm dia pipe. |
| 295 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).a) 40 mm nominal bore |
| 296 | SH:XIII:SANITARY INSTALLATION |
| 297 | Providing and fixing white vitreous china type water closet pedestal (European type WC pan) with seat and lid CP brass hinges and rubber buffers, 12.5 Litres high level CI flushing cistern with fittings RS or CI brackets, galvanized steel telescopic flush pipe with fittings and clamps, 20 GI overflow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting making good the walls and floors where required.a) WC pan with white plastic seat and lid. |
| 298 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. a) Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality. |
| 299 | Providing and fixing 100 mm sand cast iron grating for gulley, floors or nahni trap |
| 300 | Providing and fixing CP Brass Chain and rubber plug complete for sink or wash basins. |
| 301 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 302 | Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard rail complete, fixed to wooden cleadts with CP brass screws. |
| 303 | Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality).a)750 x 20 mm |
| 304 | Providing and fixing toilet paper holder.a) CP Brass |
| 305 | Providing best available local wood 50 x 50 x 50 mm wood plugs including cutting brick work and fixing in cement mortar 1:3 (1 cement : 3 fine sand). |
| 306 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.a) 100 mm dia |
| 307 | Providing and fixing sand cast iron heel rest sanitary bend.b)75mm dia. |
| 308 | Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.b) 80 x 80 x 80 mm |
| 309 | Providing and fixing sand cast iron single equal plain junction of required degreeb) 80 x 80 x 80 mm |
| 310 | Providing and fixing sand cast iron trap of self cleadnsing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors.a)100mm inlet and 100mm outlet. |
| 311 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :a) Kitchen sink with drain board. i) 510x1040 mm bowl depth 250 mm |
| 312 | Providing and fixing health faucet (set) with metal tube of Jaquar/ equivalent quality. |
| 313 | Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design.a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg). |
| 314 | SH : XIV UNDERGROUND SUMP |
| 315 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 316 | Boulder Soling in foundation and plinth ramming, consolidating and dressing complete. |
| 317 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in :a) Foundations and plinth |
| 318 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 319 | Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in :a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size) |
| 320 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 321 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 322 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 323 | Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel |
| 324 | Centring and shuttering including strutting, propping etc and removal of form work fora)Foundation, footings, bases of columns etc. and mass concrete. |
| 325 | b)Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 326 | c)Columns, pillars, posts and struts etc. |
| 327 | d)Lintels, beams, girders, bressumers and cantilevers etc. |
| 328 | e)Suspended floors, roofs, landings shelves and their supports balconies and chajjas (3.5m height). |
| 329 | 12 mm cement plaster 1 : 3 (1 cement : 3 fine sand). |
| 330 | Neat cement punning. |
| 331 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 332 | Providing, Supplying, Testing & Commissioning of 2 Hp Electric Motor Pump for lifting of water |
| 333 | SH : XV SEPTIC TANK |
| 334 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 335 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Foundations and plinth |
| 336 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 337 | Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in :a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size) |
| 338 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 339 | Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel |
| 340 | Centring and shuttering including strutting, propping etc and removal of form work fora) Foundation, footings, bases of columns etc. and mass concrete. |
| 341 | b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 342 | c)Suspended floors, roofs, landing shelve and theirsupports, balconies and chajjas (3.50m height) |
| 343 | 12 mm cement plaster 1:3( 1 cement : 3 fine sand) |
| 344 | Neat cement punning. |
| 345 | Providing and fixing C.I manhole cover. |
| 346 | Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. a) 100 mm dia SW pipes |
| 347 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15cm thick as per standard design.a) 100 mm dia SW pipes |
| 348 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. |
| 349 | Providing and fixing sand cast iron single equal plain junction of required degreea) 100 x 100 x 100 mm |
| 350 | SH : XVI SOAK PIT |
| 351 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 352 | 2nd quality local brick honey-comb half brick work in cement mortar 1:4 (1 cement : 4 fine sand). |
| 353 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 354 | Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel |
| 355 | Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. a) 200 mm dia SW pipes |
| 356 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15cm thick as per standard design.a) 200 mm dia SW pipes |
| 357 | SH : XVIIFIRE FIGHTING SYSTEM |
| 358 | Supply, installation, testing and commissioning of single stage centrifugal type factory assembled fire pumps suitable for autometic operation at synchoronous speed of 2900 rpm, TEFC conforming to IP-55 & flexible coupling gaurd mounted on a common structural base plate with 150mm dia gun metal pressure gauges with isolation cock and piping, suitable vibration elimination pads of approved design for pump foundation, motor to be suitable for 415 volts, 3 phase 50 cycles AC.8hp Pump for Fire Hydrant Network. |
| 359 | Supply, installation, testing and commissioning of horizontal single stage centrifugal pumping set with CI volute and bronze impeller with mechanical seals directly coupled to automatic Diesel Engine complete with all accessories like self starting by means of Battery powered electric starter motor, Paper Filter type air cleaner, exhaust silencer etc. complete in allrespects.The engine & the pump will be mounted on common base plate on anti-vibration mountings.Diesel Pump for Fire Hydrant Network. |
| 360 | Supply, fabrication (as per code), installation, testing and commissioning of Pressure vessels 450mm diameter and 1000mm high fabricated from 8-10mm M.S. plate with accessories inside painting with epoxy paint and outside with enamel. |
| 361 | Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 8.8 Kg/cm2 and test pressure 14 Kg/cm2 for :-100 mm dia |
| 362 | Supply, installation, testing, trial run and commissioning of hydrants all complete as required and as approved.Providing and fixing angle iron (40 mm x 40 mm x 5 mm) MS door frame 900x2100 door capable of accommodating fire hose reel, landing valve, hose pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for making 900x600x2100 Recessed type mansoary box (by civil contractor). |
| 363 | 63mm dia single outlet GM landing valve IS marked with suitable size bolts, nuts, washers and gaskets. Landing valve shall be TAC Approved Make. |
| 364 | 63mm reinforced rubber hoses (RRL) with male and female GM coupling, IS marked- 15 m long. |
| 365 | Fire Axe |
| 366 | Providing, installing, testing & commisioning of fire brigade inlet connection (fire department connection) consisting of 4 Nos. 63 mm dia instantaneous inlet arranged on a 50 mm dia header, 1 No. 150 mm diameter Butterfly valve, 1 No. 150mm dia. Non-return valve and wall mountedbox of M.S. construction with glass door to house the above mentioned components. |
| 367 | Providing, installing, testing & commisioning of fire brigade draw out connection (fire department connection) with suction pipe MS class \"C\" 100 mm dia. & 100 mm dia. foot valve & steel chain including wall mounted box M.S. construction with glass door to house the above mentionedcomponenets. |
| 368 | Providing and fixing C.I.double acting air valves of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if reqd. will be paid separately)100 mm dia |
| 369 | Providing & Fixing C.I.sluice valve(with cap)complete with bolts, nuts, rubber insertions etc.(the tail pieces if required will be paid separately)100 mm dia.pipe (Class II) |
| 370 | NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.100 mm dia |
| 371 | Providing laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 1239/3589 (all pipes shall be ISI marked and of makes specified in the specifications) i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in groundincluding excavation & providing cement concrete blocks as supports and anti-corrosive treatment to burried pipes by wrapping & coating with 4 mm thk. (OR 2 COATS of 2mm thick tape) anticorrosion tape along with two coat of black japan primer for under-ground pipeincluding digging and backfilling upto 1.0 mtr. below from G.L.for external work as per IS-909 (Specification for Underground Fire Hydrant . (Under ground)100 nominal bore (class C) |
| 372 | Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats ofsynthetic enamel paint of required shade complete as per specificatipns and asrequired. (Above Ground)100 mm nominal bore (class C) |
| 373 | Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindrical body, internal discharge tube, discharge nozzle, suspension bracket, conforming toIS 2878, finished externally with red enamel paint and fixed to wall with brackets complete with internal charges. Capacity 4.5 kg |
| 374 | Fabricating, supplying, testing and commissioning of electrical control panel of 600X250X700mm size, free floor resting, fix type, single front, fabricated out of 16 SWG CRCA Sheet, noncompartmentallised dust and vermin proof, powder coated approved shade after 7 tank treatment process, cable alley interconnection, having switchgears and accessories mounting and internal wiring, earth terminals, numbering etc., complete in all respects, suitable for operation on 415V, 3 phase 50 Hz., AC supplywith enclosure protection class IP-42as required. INCOMER32A 3P 10kA, C-Curve MCB, Red Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, Yellow Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, Blue Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC8 HP HYDRANT PUMP AC3: 22A AC1: 32A 3P Power Contactor, Coil: 240V AC, Aux. Contact: 1NO, Type: MNX 22, 14-23A Thermal Overload Relay, Directly Operated, Direct Mounting on MNX 09-40, Type: MN 2, Red Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, Amber Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, Red Flush Head Push Button 22.5 mm, Green Flush Head Push Button 22.5 mm, 1NO Contact Block, 1NC Contact Block, 6A 1P 2Way Local - Remote/ Auto-Manual Switch with Center OFF, 60 Deg. Operation, 6A 1P 10kA, C-Curve MCBDIESEL ENGINE PUMP CONTROL FEEDER32A 2P 10kA, C-Curve MCB, 10 AMP Battery Charger-24 V DC, AC Relay, DC Relay, 6A 1P 2Way Local - Remote/ Auto-Manual Switch with Center OFF, 60 Deg. Operation, Red Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, Amber Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, Red Flush Head Push Button 22.5 mm, Green Flush Head Push Button 22.5 mm, DC Voltmeter, 1Ph, Range : 200mV - 600V with Built-in Resistance, Accuracy Class : 1, Size : 96x96, Model: AE 82142, DC Ammeter, 1Ph, Range : 20mA to 5A Direct, Above 5A: External Shunt 50/60/75mV drop, Accuracy Class : 1, Size : 96x96, Model: AE 80142 |
| 375 | Supplying and Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure withcover platehavinglockingarrangementand watering pipe etc, with charcoal/ coke and salt as required. |
| 376 | Supplying and laying 25 mm x 5 mm.G.I. strip in 40 mm dia. G.I. Pipe from earth electrode, including connection with GI nut, bolt, spring, washer excavation and re-filling etc as required. |
| 377 | Providing & fixing 25mm x 5mm G.I. strip on surface or in recess forconnections etc. as required. |
| 378 | Providing and Fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing alongwith existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 379 | Laying and fixing of One number PVC Insulated and PVC Sheathed/XLPE power cable of 1.1 kV grade of size not exceeding 35 sqmm on surface as required. |
| 380 | Laying and fixing of One number PVC Insulated and PVC Sheathed/XLPE power cable of 1.1 kV grade of folloing size on wall surface as required. Aboved 35 sq mm and upto 95 sq mm (clamed with 25x3mm MS flat clam) |
| 381 | Supplying of all materials and making terminations of 1.1 KV grade aluminium multicore cables of the following sizes.The work includes cable glanding using brass plated double compression glands, sizing the core leads, removing insulation, fixing suitable crimping type copper lugs/ thimbles by using hydraulic crimping tools with correct size of the dies, shaping the leads and neatly connecting the same to the equipment terminals. 3.5 Core 120 sq. mm. Armoured Aluminium cable. |
| 382 | 3.5 Core 35 sq. mm. Armoured Aluminium cable. |
| 383 | 3.5 Core 16 sq. mm. Armoured Aluminium cable. |
| 384 | Control Cabling (PVC insulated and PVC sheathed, armoured, Copper Conductor of 1.1 KV grade on existing cable trays).5C x 1.5 Sq. mm |
| 385 | Yardstick for Furnishing of Residential Quarters |
| 386 | Carriage of the Material to Site |
| 387 | SUB HEAD-I( WIRING) |
| 388 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.\"Group \"A\" |
| 389 | Wiring for light / power plug with 2x4 mm² FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit along with 1 No 4 mm² FR PVC insulated copper conductor single core cable for loop earthing as required |
| 390 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire |
| 391 | 2 x 4.0 mm² + 1 x 4.0 mm² earth wire |
| 392 | 2x10 sqmm +1x 6.0 sq.mm earth wire |
| 393 | SUB-HEAD-II (PVC CONDUIT, METAL BOXES, SWITCHES & ACCESSORIES) |
| 394 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 395 | 40 mm |
| 396 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) |
| 397 | 3 Module (100mmX75mm) |
| 398 | 4 Module (125mmX75mm) |
| 399 | 6 Module (200mmX75mm) |
| 400 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A Switch |
| 401 | 15/16 A switch |
| 402 | 3 pin 5/6 amp socket outlet |
| 403 | 6 pin 15/16 amp socket outlet |
| 404 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 405 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 A TP&N |
| 406 | 200 A TP&N |
| 407 | 400 A TP&N |
| 408 | Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.400 A TPN |
| 409 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door |
| 410 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way , Double door |
| 411 | 8 way , Double door |
| 412 | 12 way , Double door |
| 413 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 414 | Single pole and neutral |
| 415 | Double pole and neutral |
| 416 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A |
| 417 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 418 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 419 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 420 | Supplying, Installation, testing and commissioning of LEDlamp.a) 9 Watt |
| 421 | b) 20 Watt |
| 422 | c) 40 Watt |
| 423 | Supplying and Providing of CelingfanHavells or other approved brand by Engineer-in-Charge |
| 424 | Supplying and Providing of exhaustfanHavells or other approved brand by Engineer-in-Charge |
| 425 | Supplying of Al. Thimble of following sizes :-35 sqmm |
| 426 | 95 sqmm |
| 427 | SUB-HEAD -III(EARTHING) |
| 428 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 429 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 430 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required |
| 431 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 432 | C. C/o TY-IV Quarters 1-Block (1 Block-6 Unit) |
| 433 | SH : I : EARTH WORK. |
| 434 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 435 | Extra for every additional lift of 1.50 m or part thereof for earth work in all soils including shingles, small size boulders upto 30 cm size but excluding saturated soil and rock. |
| 436 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 437 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 438 | Providing and laying Boulder filling |
| 439 | SH :- II:CEMENT CONCRETE WORK. |
| 440 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth |
| 441 | SH : III:R.C.C.WORK |
| 442 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;using coarse aggregate and fine aggregate derived from natural sources,portland Pozzolana/Ordinary Portland/Portland Slag cement,admixtures in recommended proprtions as per IS:9103 to accelerate/retard setting of concret,to improve durability and workability without imparing strenght:including pumping of concrete to site of laying,curing,carriage for all leads:but excluding the cost of centuring,centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge:for the following grades of concrete.All work upto plint levela) Concrete of M25 grade with minimum cement content of 330kg/cum |
| 443 | All work above plinth level upto V leveld) Concrete of M25 grade with minimum cement content of 330kg/cum |
| 444 | Centring and shuttering including strutting, propping etc and removal of form work for :a)Foundation, footings, bases of columns etc. and mass concrete. |
| 445 | b)Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 446 | c)Columns, pillars, posts and struts etc. |
| 447 | d)Lintels, beams, girders, bressumers and cantilevers etc. |
| 448 | e)Suspended floors, roofs, landings shelves and their supports balconies and chajjas (3.5m height). |
| 449 | f)Stairs (excluding landing) except spiral stair cases. |
| 450 | g)Vertical and horizontal fins individually or forming box louvers bands and facias |
| 451 | Reinforcement of RCC work including bending, binding and placing in position complete.a) Tar/TMT steel |
| 452 | SH : IV: BRICK WORK. |
| 453 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
| 454 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 455 | Extra for brick work in superstructure above floor two level, per floor per Cu.m. (1% of rate of brickwork from plinth up to floor two level). |
| 456 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 457 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 458 | Extra for half brick masonary in superstructure above floor two level. |
| 459 | SH : V : WOOD WORK |
| 460 | Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position. |
| 461 | Supplying and fixing factory made panelled shutters made out of best available hard wood for doors including panelling with panels 12 mm thick commercial veneered teak wood particle boards (Phenyle Bonded) 3 layers flat pressed including applying one coat of approved wood primer.a) 40 mm thick including anodized aluminum butt hinges with necessary screws. |
| 462 | Providing and fixing factory made uPVC door shutters, decorative typeincluding door frame, with necessary screws and all fittings as per the direction of Engneer-in-charge. |
| 463 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 464 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.b) Ornamental grill. |
| 465 | Providing and fixing aluminum butt hinges anodised, transparent or dyed to required color or shade with necessary screws etc complete.a) 100 x 75 x 4 mm |
| 466 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete.a)300 x 10 mm |
| 467 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.a)125 mm |
| 468 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a)300 x 16 mm |
| 469 | SH : VI : STEEL WORK. |
| 470 | Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete. |
| 471 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.a) In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 472 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 473 | Providing and fixing 12 mm thick and 100 mm wide pelmet with 25 mm dia ss curtain rod and brackets including fixing with 25 x 3 mm MS flat 10 cm long and plugs etc complete. |
| 474 | SH:VII:ALUMINIUM WORK |
| 475 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) :For fixed portion.1.3. Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 476 | For shutters of doors, windows & ventilators including providing and fixing hinges /pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately).2.3) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron). |
| 477 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item)4.1) With float glass panes of 4.0 mm thickness. |
| 478 | SH:VIII:FLOORING |
| 479 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.a)Size of Tile 600x600 mm |
| 480 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., completea)Size of Tile600x600 mm |
| 481 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.(a) Granite stone slab of colour black, Cherry/Ruby red 18 mm thick (slab area upto 0.50 sqm) |
| 482 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.a) Marble work |
| 483 | Providing and laying matt finished vitrified tile of size 100x100x16mm having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in out door floors such as footpath, court yard multi models etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as direction of Engineer-in-Charge.Tiles for Parking |
| 484 | SH : IX : FINISHING |
| 485 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 486 | 6 mm cement plaster to ceiling 1 : 4 (1 cement : 4 fine sand). |
| 487 | Providing two coats of acrylic water based wall putty/ wall filler of Asian Paits/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the halp of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department. |
| 488 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 489 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 490 | Painting two coats with oil type wood preservative of approved brand and manufacture on new work. |
| 491 | Applying priming coat consisting of a mixture of red lead, white lead and double boiled linseed oil in the ratio of 0.7 Kg : 0.7 Kg : 1 Litre on wood work complete. |
| 492 | Applying priming coat of a mixture of red lead raw linseed oil and turpentine oil in the ratio of 2.80 Kg : 1 Litre : 1 Litre on steel work complete. |
| 493 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
| 494 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade. |
| 495 | SH:X:DRAINAGE |
| 496 | Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete. |
| 497 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 498 | SH:XI:ROOFING |
| 499 | Providing and fixing on wall face C.I. rain water pipe including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1 : 2 ( 1 cement : 2 fine sand).d)150 mm diameter pipe |
| 500 | Lime concrete terracing on roofs, average thickness 10 cm laid to fall with 25 mm gauge brick ballast and 50% mortar consisting of 1 lime putty and 2 surki finished with gur and belgiri treatment complete and covered with flat brick tiles grouted with cement mortar 1 : 3 (1 cement : 3 fine sand) over 12 mm layer cement mortar 1 : 3 (1 cement : 3 fine sand)and finished neat. |
| 501 | SH : XII: WATER SUPPLY. |
| 502 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.a) Concealed work, including cutting chases and making good the walls etc.i) 15 mm nominal outer dia Pipes |
| 503 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).a)20mm nominal bore. |
| 504 | Providing and fixing brass bib/pillar cock of Jaquar or equivalent quality.a)15mm nominal bore. |
| 505 | Providing and fixing brass stop cock of Jaquar or equivalent quality.a)15mm nominal bore. |
| 506 | Providing and fixing 3 in 1 Wall Mixer Tap of Jaquar or equivalent quality.a)15mm nominal bore. |
| 507 | Providing and fixing PVC connection pipe with brass union 30cm length.a)15mm nominal bore. |
| 508 | Providing and fixing CP brass shower rose with 15 mm or 20 mm dia inleta)150 mm dia |
| 509 | Painting G.I. pipes and fittings with white paint over a coat of ready mixed priming coat both of approved quality for new work.a)20mm dia pipe. |
| 510 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).a) 40 mm nominal bore |
| 511 | SH:XIII:SANITARY INSTALLATION |
| 512 | Providing and fixing white vitreous china type water closet pedestal (European type WC pan) with seat and lid CP brass hinges and rubber buffers, 12.5 Litres high level CI flushing cistern with fittings RS or CI brackets, galvanized steel telescopic flush pipe with fittings and clamps, 20 GI overflow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting making good the walls and floors where required.a) WC pan with white plastic seat and lid. |
| 513 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. a) Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality. |
| 514 | Providing and fixing 100 mm sand cast iron grating for gulley, floors or nahni trap |
| 515 | Providing and fixing CP Brass Chain and rubber plug complete for sink or wash basins. |
| 516 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 517 | Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard rail complete, fixed to wooden cleadts with CP brass screws. |
| 518 | Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality).a)750 x 20 mm |
| 519 | Providing and fixing toilet paper holder.a) CP Brass |
| 520 | Providing best available local wood 50 x 50 x 50 mm wood plugs including cutting brick work and fixing in cement mortar 1:3 (1 cement : 3 fine sand). |
| 521 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.a) 100 mm dia |
| 522 | Providing and fixing sand cast iron heel rest sanitary bend.b)75mm dia. |
| 523 | Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.b) 80 x 80 x 80 mm |
| 524 | Providing and fixing sand cast iron single equal plain junction of required degreeb) 80 x 80 x 80 mm |
| 525 | Providing and fixing sand cast iron trap of self cleadnsing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors.a)100mm inlet and 100mm outlet. |
| 526 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :a) Kitchen sink with drain board. i) 510x1040 mm bowl depth 250 mm |
| 527 | Providing and fixing health faucet (set) with metal tube of Jaquar/ equivalent quality. |
| 528 | Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design.a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg). |
| 529 | SH : XIV UNDERGROUND SUMP |
| 530 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 531 | Boulder Soling in foundation and plinth ramming, consolidating and dressing complete. |
| 532 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in :a) Foundations and plinth |
| 533 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 534 | Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in :a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size) |
| 535 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 536 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 537 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 538 | Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel |
| 539 | Centring and shuttering including strutting, propping etc and removal of form work fora)Foundation, footings, bases of columns etc. and mass concrete. |
| 540 | b)Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 541 | c)Columns, pillars, posts and struts etc. |
| 542 | d)Lintels, beams, girders, bressumers and cantilevers etc. |
| 543 | e)Suspended floors, roofs, landings shelves and their supports balconies and chajjas (3.5m height). |
| 544 | 12 mm cement plaster 1 : 3 (1 cement : 3 fine sand). |
| 545 | Neat cement punning. |
| 546 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 547 | Providing, Supplying, Testing & Commissioning of 2 Hp Electric Motor Pump for lifting of water |
| 548 | SH : XV SEPTIC TANK |
| 549 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 550 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Foundations and plinth |
| 551 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 552 | Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in :a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size) |
| 553 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 554 | Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel |
| 555 | Centring and shuttering including strutting, propping etc and removal of form work fora) Foundation, footings, bases of columns etc. and mass concrete. |
| 556 | b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 557 | c)Suspended floors, roofs, landing shelve and theirsupports, balconies and chajjas (3.50m height) |
| 558 | 12 mm cement plaster 1:3( 1 cement : 3 fine sand) |
| 559 | Neat cement punning. |
| 560 | Providing and fixing C.I manhole cover. |
| 561 | Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. a) 100 mm dia SW pipes |
| 562 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15cm thick as per standard design.a) 100 mm dia SW pipes |
| 563 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. |
| 564 | Providing and fixing sand cast iron single equal plain junction of required degreea) 100 x 100 x 100 mm |
| 565 | SH : XVI SOAK PIT |
| 566 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 567 | 2nd quality local brick honey-comb half brick work in cement mortar 1:4 (1 cement : 4 fine sand). |
| 568 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 569 | Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel |
| 570 | Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. a) 200 mm dia SW pipes |
| 571 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15cm thick as per standard design.a) 200 mm dia SW pipes |
| 572 | SH : XVIIFIRE FIGHTING SYSTEM |
| 573 | Supply, installation, testing and commissioning of single stage centrifugal type factory assembled fire pumps suitable for autometic operation at synchoronous speed of 2900 rpm, TEFC conforming to IP-55 & flexible coupling gaurd mounted on a common structural base plate with 150mm dia gun metal pressure gauges with isolation cock and piping, suitable vibration elimination pads of approved design for pump foundation, motor to be suitable for 415 volts, 3 phase 50 cycles AC.8hp Pump for Fire Hydrant Network. |
| 574 | Supply, installation, testing and commissioning of horizontal single stage centrifugal pumping set with CI volute and bronze impeller with mechanical seals directly coupled to automatic Diesel Engine complete with all accessories like self starting by means of Battery powered electric starter motor, Paper Filter type air cleaner, exhaust silencer etc. complete in allrespects.The engine & the pump will be mounted on common base plate on anti-vibration mountings.Diesel Pump for Fire Hydrant Network. |
| 575 | Supply, fabrication (as per code), installation, testing and commissioning of Pressure vessels 450mm diameter and 1000mm high fabricated from 8-10mm M.S. plate with accessories inside painting with epoxy paint and outside with enamel. |
| 576 | Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 8.8 Kg/cm2 and test pressure 14 Kg/cm2 for :-100 mm dia |
| 577 | Supply, installation, testing, trial run and commissioning of hydrants all complete as required and as approved.Providing and fixing angle iron (40 mm x 40 mm x 5 mm) MS door frame 900x2100 door capable of accommodating fire hose reel, landing valve, hose pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for making 900x600x2100 Recessed type mansoary box (by civil contractor). |
| 578 | 63mm dia single outlet GM landing valve IS marked with suitable size bolts, nuts, washers and gaskets. Landing valve shall be TAC Approved Make. |
| 579 | 63mm reinforced rubber hoses (RRL) with male and female GM coupling, IS marked- 15 m long. |
| 580 | Fire Axe |
| 581 | Providing, installing, testing & commisioning of fire brigade inlet connection (fire department connection) consisting of 4 Nos. 63 mm dia instantaneous inlet arranged on a 50 mm dia header, 1 No. 150 mm diameter Butterfly valve, 1 No. 150mm dia. Non-return valve and wall mountedbox of M.S. construction with glass door to house the above mentioned components. |
| 582 | Providing, installing, testing & commisioning of fire brigade draw out connection (fire department connection) with suction pipe MS class \"C\" 100 mm dia. & 100 mm dia. foot valve & steel chain including wall mounted box M.S. construction with glass door to house the above mentionedcomponenets. |
| 583 | Providing and fixing C.I.double acting air valves of approved quality with bolts, nuts, rubber insertions etc. complete ( The tail pieces, tapers etc. if reqd. will be paid separately) 100 mm dia |
| 584 | Providing & Fixing C.I.sluice valve(with cap)complete with bolts, nuts, rubber insertions etc.(the tail pieces if required will be paid separately)100 mm dia.pipe (Class II) |
| 585 | NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.100 mm dia |
| 586 | Providing laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 1239/3589 (all pipes shall be ISI marked and of makes specified in the specifications) i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in groundincluding excavation & providing cement concrete blocks as supports and anti-corrosive treatment to burried pipes by wrapping & coating with 4 mm thk. (OR 2 COATS of 2mm thick tape) anticorrosion tape along with two coat of black japan primer for under-ground pipeincluding digging and backfilling upto 1.0 mtr. below from G.L.for external work as per IS-909 (Specification for Underground Fire Hydrant . (Under ground)100 nominal bore (class C) |
| 587 | Providing, laying, testing & commissioning of “C” class heavy duty MS pipe conforming to IS 3589 and 1239 (all pipes shall be ISI marked and shall be one of approved makes) including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats ofsynthetic enamel paint of required shade complete as per specificatipns and asrequired. (Above Ground)100 mm nominal bore (class C) |
| 588 | Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindrical body, internal discharge tube, discharge nozzle, suspension bracket, conforming toIS 2878, finished externally with red enamel paint and fixed to wall with brackets complete with internal charges. Capacity 4.5 kg |
| 589 | Fabricating, supplying, testing and commissioning of electrical control panel of 600X250X700mm size, free floor resting, fix type, single front, fabricated out of 16 SWG CRCA Sheet, noncompartmentallised dust and vermin proof, powder coated approved shade after 7 tank treatment process, cable alley interconnection, having switchgears and accessories mounting and internal wiring, earth terminals, numbering etc., complete in all respects, suitable for operation on 415V, 3 phase 50 Hz., AC supplywith enclosure protection class IP-42as required. INCOMER32A 3P 10kA, C-Curve MCB, Red Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, Yellow Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, Blue Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC8 HP HYDRANT PUMP AC3: 22A AC1: 32A 3P Power Contactor, Coil: 240V AC, Aux. Contact: 1NO, Type: MNX 22, 14-23A Thermal Overload Relay, Directly Operated, Direct Mounting on MNX 09-40, Type: MN 2, Red Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, Amber Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, Red Flush Head Push Button 22.5 mm, Green Flush Head Push Button 22.5 mm, 1NO Contact Block, 1NC Contact Block, 6A 1P 2Way Local - Remote/ Auto-Manual Switch with Center OFF, 60 Deg. Operation, 6A 1P 10kA, C-Curve MCBDIESEL ENGINE PUMP CONTROL FEEDER32A 2P 10kA, C-Curve MCB, 10 AMP Battery Charger-24 V DC, AC Relay, DC Relay, 6A 1P 2Way Local - Remote/ Auto-Manual Switch with Center OFF, 60 Deg. Operation, Red Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, Amber Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC, Red Flush Head Push Button 22.5 mm, Green Flush Head Push Button 22.5 mm, DC Voltmeter, 1Ph, Range : 200mV - 600V with Built-in Resistance, Accuracy Class : 1, Size : 96x96, Model: AE 82142, DC Ammeter, 1Ph, Range : 20mA to 5A Direct, Above 5A: External Shunt 50/60/75mV drop, Accuracy Class : 1, Size : 96x96, Model: AE 80142 |
| 590 | Supplying and Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure withcover platehavinglockingarrangementand watering pipe etc, with charcoal/ coke and salt as required. |
| 591 | Supplying and laying 25 mm x 5 mm.G.I. strip in 40 mm dia. G.I. Pipe from earth electrode, including connection with GI nut, bolt, spring, washer excavation and re-filling etc as required. |
| 592 | Providing & fixing 25mm x 5mm G.I. strip on surface or in recess forconnections etc. as required. |
| 593 | Providing and Fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing alongwith existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 594 | Laying and fixing of One number PVC Insulated and PVC Sheathed/XLPE power cable of 1.1 kV grade of size not exceeding 35 sqmm on surface as required. |
| 595 | Laying and fixing of One number PVC Insulated and PVC Sheathed/XLPE power cable of 1.1 kV grade of folloing size on wall surface as required. Aboved 35 sq mm and upto 95 sq mm (clamed with 25x3mm MS flat clam) |
| 596 | Supplying of all materials and making terminations of 1.1 KV grade aluminium multicore cables of the following sizes.The work includes cable glanding using brass plated double compression glands, sizing the core leads, removing insulation, fixing suitable crimping type copper lugs/ thimbles by using hydraulic crimping tools with correct size of the dies, shaping the leads and neatly connecting the same to the equipment terminals. 3.5 Core 120 sq. mm. Armoured Aluminium cable. |
| 597 | 3.5 Core 35 sq. mm. Armoured Aluminium cable. |
| 598 | 3.5 Core 16 sq. mm. Armoured Aluminium cable. |
| 599 | Control Cabling (PVC insulated and PVC sheathed, armoured, Copper Conductor of 1.1 KV grade on existing cable trays).5C x 1.5 Sq. mm |
| 600 | Yardstick for Furnishing of Residential Quarters |
| 601 | Carriage of the Material to Site |
| 602 | Passenger Lift (Capcity 8 Person) |
| 603 | SUB HEAD-I( WIRING) |
| 604 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.\"Group \"A\" |
| 605 | Wiring for light / power plug with 2x4 mm² FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit along with 1 No 4 mm² FR PVC insulated copper conductor single core cable for loop earthing as required |
| 606 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire |
| 607 | 2 x 4.0 mm² + 1 x 4.0 mm² earth wire |
| 608 | 2x10 sqmm +1x 6.0 sq.mm earth wire |
| 609 | SUB-HEAD-II (PVC CONDUIT, METAL BOXES, SWITCHES & ACCESSORIES) |
| 610 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 611 | 40 mm |
| 612 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) |
| 613 | 3 Module (100mmX75mm) |
| 614 | 4 Module (125mmX75mm) |
| 615 | 6 Module (200mmX75mm) |
| 616 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A Switch |
| 617 | 15/16 A switch |
| 618 | 3 pin 5/6 amp socket outlet |
| 619 | 6 pin 15/16 amp socket outlet |
| 620 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 621 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 A TP&N |
| 622 | 200 A TP&N |
| 623 | 400 A TP&N |
| 624 | Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.400 A TPN |
| 625 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door |
| 626 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way , Double door |
| 627 | 8 way , Double door |
| 628 | 12 way , Double door |
| 629 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 630 | Single pole and neutral |
| 631 | Double pole and neutral |
| 632 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A |
| 633 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 634 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 635 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 636 | Supplying, Installation, testing and commissioning of LEDlamp.a) 9 Watt |
| 637 | b) 20 Watt |
| 638 | c) 40 Watt |
| 639 | Supplying and Providing of CelingfanHavells or other approved brand by Engineer-in-Charge |
| 640 | Supplying and Providing of exhaustfanHavells or other approved brand by Engineer-in-Charge |
| 641 | Supplying of Al. Thimble of following sizes :-35 sqmm |
| 642 | 95 sqmm |
| 643 | SUB-HEAD -III(EARTHING) |
| 644 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 645 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 646 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required |
| 647 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 648 | D. Development Work |
| 649 | SH: I Approach Road (Formation Cutting) |
| 650 | Excavation in Ordinary Rockusing Hydraulic ExcavatorCK-90 and Tippers with disposal upto 1000 metres. (Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site within all lifts and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections.) |
| 651 | SH: II Approach Road with WMM and Bituminous Top |
| 652 | Preparation of sub grade by excavating earth to an average depth of 22.50 cm, dressing to camber and consolidating with road roller, making good the undulations etc. and disposal of surplus earth, lead upto 50 m. |
| 653 | Consolidation of sub-grade with road roller of 8 to 12 tonne capacity including making good the undulations etc. with earth or quarry spoils etc. and rerolling the sub grade. |
| 654 | Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.) |
| 655 | Open - Graded Premix Surfacing (Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or cut-back or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades.)Case - I: Mechanical method using Penetration grade Bitumen and HMP of appropriate capacity not less than 75 tonnes/hour . |
| 656 | Prime coat (Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60 kg/sqm using mechanical means.) |
| 657 | Seal Coat (Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats)Case - I : Type A |
| 658 | SH: III Internal Road (CC Pavement) |
| 659 | Construction cost for 3.75m width & 10.00m length |
| 660 | Preparation of sub grade by excavating earth to an average depth of 22.50 cm, dressing to camber and consolidating with road roller, making good the undulations etc. and disposal of surplus earth, lead upto 50 m. |
| 661 | Consolidation of sub-grade with road roller of 8 to 12 tonne capacity including making good the undulations etc. with earth or quarry spoils etc. and rerolling the sub grade. |
| 662 | Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.) |
| 663 | Cement Concrete Pavement:- Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing) |
| 664 | Add for Carriage of materials |
| 665 | SH: IV Footpath |
| 666 | Construction cost for 1.2 m width & 10 m length |
| 667 | Excavation in Soil by Manual Means. (Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto1000 mtrs.) |
| 668 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 669 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Foundations and plinth |
| 670 | Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineerin- Charge. |
| 671 | Add for Carriage of materials |
| 672 | SH: V CC Parking for Guest |
| 673 | Construction cost for 100 Sqm |
| 674 | Earth work in excavation in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) including banking in 20 cm layers and breaking clods, ramming and dressing up for the purpose of making embankments or filling up ground depressions, lead upto 50 m and lift upto 1.50 m. |
| 675 | (Dry rubble Flooring) Boulder Soling in foundation and plinth ramming, consolidating and dressing complete. |
| 676 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 677 | Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in :a) Foundations and plinth |
| 678 | Add for Carriage of materials |
| 679 | SH: VI Trenches for Services |
| 680 | Cable Duct Across the Road (Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997 and approved drawings.)(ii) Double Row for two utility services |
| 681 | SH: VII External Sewerage |
| 682 | Cost for Construction of 10 mtr |
| 683 | Earth work in excavation in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) including banking in 20 cm layers and breaking clods, ramming and dressing up for the purpose of making embankments or filling up ground depressions, lead upto 50 m and lift upto 1.50 m. |
| 684 | (Dry rubble Flooring) Boulder Soling in foundation and plinth ramming, consolidating and dressing complete. |
| 685 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 686 | Providing and Layng light duty non-pressure NP2 Class RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 Cement : 2 fine sand) including testing joints etc completed) 300 mm dia RCC Pipes (NP2) |
| 687 | Add carriage of materials |
| 688 | SH: VIII CC Strom Water Drains (0.3 m x 0.5 m) |
| 689 | Construction cost for 10 m length |
| 690 | Earth work in excavation in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) including banking in 20 cm layers and breaking clods, ramming and dressing up for the purpose of making embankments or filling up ground depressions, lead upto 50 m and lift upto 1.50 m. |
| 691 | Boulder Soling in foundation and plinth ramming, consolidating and dressing complete. |
| 692 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 693 | Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : :b) Walls including attached buttresses, pilasters and their caps and bases and string courses etc. up to floor two level. |
| 694 | Centring and shuttering including strutting, propping etc and removal of form work for :b) Walls including attached buttresses, pilasters etc. |
| 695 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 696 | Neat cement punning. |
| 697 | Add carriage of materials |
| 698 | SH: IX Boundary/ Compound Wall |
| 699 | Cost of construction for 10 running Mtr |
| 700 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 701 | Dry Rubble Flooring (Boulder Soling in foundation and plinth ramming, consolidating and dressing complete). |
| 702 | Re-filling excavated earth in plinth including watering, ramming, consolidating and dressing complete. |
| 703 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth |
| 704 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 705 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 706 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 707 | Centring and shuttering including strutting, propping etc and removal of form work for :a)Foundation, footings, bases of columns etc. and mass concrete. |
| 708 | b)Columns, pillars, posts and struts etc. |
| 709 | c)Lintels, beams, girders, bressumers and cantilevers etc. |
| 710 | Reinforcement of RCC work including bending, binding and placing in position complete. a) Tar/TMT steel |
| 711 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
| 712 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 713 | 12 mm cement plaster 1 : 3 (1 cement : 3 fine sand). |
| 714 | White washing with whiting on new work (three or more coats) to give even shade. |
| 715 | Carriage of the Material |
| 716 | SH: X Horticulture/ Avenue Plantation |
| 717 | Making Lawns including Ploughing and Dragging with \"Swagha\" Breaking of Clod (Making lawns including ploughing and breaking of clod, removal of rubbish, dressing and supplying doobs grass roots and planting at 15 cm apart, including supplying and spreading of farm yard manure at rate of 0.18 cum per 100 sqm) |
| 718 | Turfing Lawns with Fine Grassing including Ploughing, Dressing (Turfing lawns with fine grassing including ploughing, dressing including breaking of clods, removal of rubbish, dressing and supplying doobs grass roots at 10 cm apart, including supplying and spreading of farm yard manure at rate of0.6 cum per 100 sqm) |
| 719 | Grassing with \" Doobs\" Grass (Grassing with \"Doobs\" grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed)(ii) In rows 7.5 cm apart in either direction |
| 720 | Planting Permanent Hedges including Digging of Trenches (Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100 metres and supplying and planting hedge plants at 30 cm apart) |
| 721 | Planting of Trees and their Maintenance for one Year (Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge mannure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year) |
| 722 | Tree Guard with MS Angle Iron and Steel Wire (Providing and fixing tree guard 0.60 metre square, 2.00 metre high fabricated with MS angle iron 30 x 30 x 3 mm, MS iron 25 x 3 mm and steel wire3 mm dia welded and fabricated as per design in two halves bolted together) |
| 723 | SH: XI Site Clearance |
| 724 | Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit.)(i) Girth from 300 mm to 600 mm |
| 725 | (ii) Girth from 600 mm to 900 mm |
| 726 | (iii) Girth from 900 mm to 1800 mm |
| 727 | Clearing Grass and Removal of Rubbish |
| 728 | Clearing and Grubbing Road Land (Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 mtrs including removal and disposal of top organic soil not exceeding 150 mm in thickness.)(i) By Manual Means:-B. In area of thorny jungle |
| 729 | SH: XII Levelling Works (Cutting & Filling) |
| 730 | Excavation in Soil using Hydraulic Excavator CK 90 and Tippers with disposal upto 1000 mtrs. (Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m) |
| 731 | SH: XIII Paving around building with Paver Block |
| 732 | Construction cost for 100 sqm Area |
| 733 | Earth work in excavation in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) including banking in 20 cm layers and breaking clods, ramming and dressing up for the purpose of making embankments or filling up ground depressions, lead upto 50 m and lift upto 1.50 m. |
| 734 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in- Charge. (i) 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 735 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth |
| 736 | Add for carriage of materials |
| 737 | SH: XIV RCC Retaining Wall (3.00 m Height) |
| 738 | Construction Cost for 10 Mtr Length |
| 739 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 740 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 741 | Providing and laying Boulder filling (Dry rubble Flooring) |
| 742 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth |
| 743 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 744 | Reinforced cement concrete in retaining wall (any thickness) including attached pillasters, buttresses, plinth and string courses, fillets etc from top of foundation up to floor two level excluding cost of centring,shuttering and reinforcement in :b) M20 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 745 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 746 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 747 | Centring and shuttering including strutting, propping etc and removal of form work for :a)Foundation, footings, bases of columns etc. and mass concrete. |
| 748 | b) Walls including attached buttresses, pilasters etc |
| 749 | c)Columns, pillars, posts and struts etc. |
| 750 | Reinforcement of RCC work including bending, binding and placing in position complete. a) Tar/TMT steel |
| 751 | Add for carriage of materials |
| 752 | SH: XV Iron Gate |
| 753 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 754 | Boulder Soling in foundation and plinth ramming, consolidating and dressing complete. (Dry rubble Flooring) |
| 755 | Re-filling excavated earth in plinth including watering, ramming, consolidating and dressing complete. |
| 756 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth |
| 757 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 758 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 759 | Centring and shuttering including strutting, propping etc and removal of form work for :a)Foundation, footings, bases of columns etc. and mass concrete. |
| 760 | b)Columns, pillars, posts and struts etc. |
| 761 | Reinforcement of RCC work including bending, binding and placing in position complete. a) Tar/TMT steel |
| 762 | 12 mm cement plaster 1 : 3 (1 cement : 3 fine sand). |
| 763 | White washing with whiting on new work (three or more coats) to give even shade. |
| 764 | Add for carriage of materials |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy