| 1 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineerin-icharge. |
| 2 | M&L Rendering 10 mm thick cement plaster 1:3 on fair faces of brick work or concrete surfaces of Ceiling, after brushing neat cement slurry with 3.0kg of cement per sqm , finished even and smooth (without using extra cement)including taking down. |
| 3 | M&L 3mm thick wall care putty on wallSurfaces includingprepering surfaces. Make: JK/Birla/Nerolac |
| 4 | M&L 3mm thick wall care putty on ceiling Surfaces includingprepering surfaces. Make: JK/Birla/Nerolac |
| 5 | Providing and fixing 15 mm thick false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on inter-locking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6 mm reveal profile (white/black),comprising of main-T runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. Make: Gyproc/Armstrong/USG Boral |
| 6 | Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately) |
| 7 | GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste. |
| 8 | M&L Plain fillets. square, rectangular or triangular in section, clean sawn, secured with nails or brads 2nd class soft wood exc 3 & n.exc 3 sqcm sectional area. |
| 9 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth. |
| 10 | M&L Preparing old painted ceiling surfaces and applying two coats of plastic emulsion paint. Make:-Berger/ Nerolac/ Shalimar/Asian |
| 11 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm.) |
| 12 | M&L Melamine polishing on wooden Panel and door(one or more coat) including cleaning and preparing the surface including a coat of wood filler. |