Tender For Provision Of Otm Accommodation For Mdc, Malad Under Ge(N) Santacruz; 1 SCH A PART-I To XII:Note: These schedules are pre-priced by MES and the Contractor shall works out his lump sum costunder Col 6. 2 Total amount of Sch ‘A’ Part I (Building & Structures) 3 Total amount of Sch ‘A’ Part II (Internal Water Supply) 4 Total amount of Sch ‘A’ Part III (Internal Electric Supply) 5 Total amount of Sch ‘A’ Part IV(Road, Path and Culverts) 6 Total amount of Sch ‘A’ Part V(Area Drainage) 7 Total amount of Sch ‘A’ Part VI (Sewage Disposal) 8 Total amount of Sch ‘A’ Part VII (Chain Link, Fencing and Gate) 9 Total amount of Sch A Part-VIII(External Water Supply) 10 Total amount of Sch A Part-IX (External Electric Supply) 11 Total amount of Sch A Part-X(Water Cooler and Air Conditioning) 12 Total amount of Sch A Part-XI(Lightning Protection) 13 Total amount of Sch A Part-XII(Site Clearance,Excavation and Earthwork) 14 NOTE: Schedule ‘A’ Part IIto XII items, which are notPrepriced by MES are given hereunder, Bidders shall insert their rate in Column-6 only and the Estimated rate indicated as 0.00 are for that purpose. 15 S&F tripple pole and neutral, powder coated, CRCA steel sheet MCB distribution board (VTPN) constructed as per IS 8623 suitable for MCCB incomer upto 160 amp, 4 way, 415 volts, degree of protection IP 43 - IK- 09 with metal door,recess mounted, having 200 amp insulated tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces etc as required complete all as specified and as directed by Engr-in-charge. 16 M&L for earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate no 3 connected to earthing test point all as specified or indicated including testing on completion with and including 15 mm bore light grade G.I. protection pipe (upto 7.5 metre beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 with RCC 1:2:4type B-1 40 mm thick cover reinforced with 6 mm dia M.S bars 3 nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work complete all as specified and directed. 17 S&F concealed stop cock, Regular body adjustable wall flange, size 25mm dia, Make- Jaquar Model No CQT-23089 or equivalent in Crab Tree/Kohler brand complete all as specified and directed by Engineer-in-Charge. 18 S&F Angular stop cock 15mm dia, quarter turn Make- Jaquar Model No CQT- 23059 or equivalent in Crab Tree/Kohler brand complete all as specified and directed by Engineer-in-Charge. 19 S&F two way bib cock 15mm dia. Make- Jaquar Model No CQT-23041 or equivalent in Crab Tree/Kohler brand complete all as specified and directed by Engineer-in-Charge. 20 S&F 15mm dia Elbow operated long head Bib cock /clinical type with 200mm lever handle cast copper alloy fancy type with chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. Make: Jaquar Model No. CQT-23347 or equivalent model of Crab Tree / Kohler 21 Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for inpur variation between 170 volts to 250 volts with out put voltage stablized at 230 voltswith accuracy of + 2.5% and capacity 5 KVA suitable for A/C complete all as specified and directed by Engr-in-Charge. 22 Supply and fix refrigerator, frost freedouble door adaptive intelligence technology, Inverter compressor, convertible freezer LED Light, deodorizer, Full size freezer on top, incl glass shelves, vegetable & fruit drawer, lock & key electric driven(single phase), capacity 165 Ltrs .BEE 5 star rated 2.5 Sqmm strained copper cable cord 3 core with 15 Amps plug top with inbuilt stablized power, complete all as specified and directed. 23 Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for inpur variation between 170 volts to 250 volts with out put voltage stablized at 230 voltswith accuracy of + 2.5% and capacity 2 KVA suitable for Deep freezer, complete all as specified and as directed. 24 M&L Earth work in excavation by manual means or Mechanical means (Hydraulic Excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out for all kind of soil and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge. 25 M&L for Excavation trenches in any kind of soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth by manual means or mechanical means (hydraulic excavator) all as directed and getting for laying of cable, foundation etc and all as per the direction. 26 M&L for Excavation trenches in any kind of soil exceeding 1.5 m and not exceeding 3.0 m by manual means or mechanical means (hydraulic excavator) all as directed and getting for laying of cable, foundation etc and all as per the direction. 27 M&L Excavation by manual means or Mechanical means (Hydraulic Excavator)/ in Foundation Trenches or drains (not exceeding 1.5 m in width or 10 sqm in on plan), including dressing of sides and ramming of bottoms , lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, depth not exceeding 1.5m, complete all as specified and directed. 28 M&L Excavation by manual means or Mechanical means (Hydraulic Excavator)/ in Foundation Trenches or drains (not exceeding 1.5 m in width or 10 sqm in on plan), including dressing of sides and ramming of bottoms , lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, depth exceeding 1.5m but not exceeding 3m, complete all as specified and directed. 29 Supplying, laying, jointing and testing ductile iron (DI) pipes of 100 mmsize incl fittings ie bends, tee etcwith spigot ends for jointing with the existing pipes, duly welded with pipes/TEEs/bends properly to both the plain ends, centrifugally cast, class K-9, in any length laidin trenchescomplete all as directed by Engineer-in-Charge. NOTE:- The unit quoted rate shall include:- (a) Short pieces of any length as required at Site.(b) Pipes shall be laid in trenches/over RCC pillars/under bridges/culverts/roads etc. (d) Earth work/PCC shall be measured and paid separately. (e) the pipeto be laid in such a way that it should below fragile zone. 30 M&L for Junction box pole mounted of size 230 x 170 x 110mm made out of engineering plastic Cabinet, IP 65, IK 08 with hinges and locking arrangement comprising 60 Amps, 4 pole aluminium bus bar mounted on DMC insulator, 1 No SP MCB 6 Amps, 10 KA, junction box should be mounted on pole with MS flat iron of sizes 40mm x 6mm including nuts, bolts and washers complete all as specified and directed. 31 M&L for threecore PVC insulatedsheathed strandedcopper conductor cable drawn into steel pole of size 1.5 sq mm for connection or security/street light fitting from junction box complete all as directed and specified and directed by Engr-in-charge. 32 M&L Street light bracket made out of 25 mm bore GI pipe Medium grade 1.5 mtr long incl. fixing clamps and nuts & boltscomplete all as directed and specified and directed by Engr-in-charge. 33 Supply and fix LED Post Top Gate light 30 watt for indirect lightning, cast aluminium housing, toughned glass, IP 65 complete with all accessories weatherproof, with clear acrylic diffuser complete all as specified and directed by Engr-in-charge.. 34 M&L for Anticorrosive painting to steel work with two coats of synthetic enamel after priming with red oxide zinc chrome,surfaces of any description, over 10cm in width or girth,not otherwise described complete all as specified and directed by E-in-C. 35 Supply only PVC Coated Chain link MS galvanisd fencing, any size or type (as approved by GE) complete all as specified and directed.Note: Fixing shall be measured and paid separately under relevant items of Schedule A Part VII. 36 Supply and lay double wall corrugated (DWC) HDPE pipe of 50/38 mm bore, as per IS-16205 including necessary couplers and bend for cable protection laid in trenches etc, complete all as specified and directed.