| 1 | Note: (i) Please refer Schedule \"A\" Notes given on serial page No. 19 to 23 of tender documents. |
| 2 | LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS |
| 3 | Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule \"A\" Part-I brought forward from serial page No. 25. |
| 4 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule \"A\" Part-II brought forward from serial page No. 30. |
| 5 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule \"A\" Part-III brought forward from serial page No. 31. |
| 6 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule \"A\" Part-IV brought forward from serial page No. 33. |
| 7 | Lump sum price worked out by the contractor for ROAD, PATH & CULVERTS WORKS as listed in Schedule \"A\" Part-V brought forward from serial page No. 36. |
| 8 | Lump sum price worked out by the contractor for FENCING, COMPOUND WALL AND GATE WORKS as listed in Schedule \"A\" Part-VI brought forward from serial page No. 38. |
| 9 | Lump sum price worked out by the contractor for AREA DRAINAGE WORKS listed in Schedule \"A\" Part-VII brought forward from serial page No. 39. |
| 10 | Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTHWORKS as listed in Schedule \"A\" Part-VIII brought forward from serial page No. 40. |
| 11 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONWORKS as listed in Schedule \"A\" Part-IX brought forward from serial page No. 42. |
| 12 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYWORKS as listed in Schedule \"A\" Part-X brought forward from serial page No. 44. |
| 13 | Lump sum price worked out by the contractor for SOLAR WATER HEATING SYSTEM as listed in Schedule \"A\" Part-XI brought forward from serial page No. 46. |
| 14 | Lump sum price worked out by the contractor for RAIN WATER HARVESTING WORKSas listed in Schedule \"A\" Part-XII brought forward from serial page No. 47. |
| 15 | Lump sum price worked out by the contractor for SUMMER APPLIANCES WORKSas listed in Schedule \"A\" Part-XIII brought forward from serial page No. 48. |
| 16 | Lump sum price worked out by the contractor for DEMOLITION & DISMANTLING WORKSas listed in Schedule \"A\" Part-XIV brought forward from serial page No. 49. |
| 17 | INTERNAL ELECTRIFICATION WORKS |
| 18 | Supply and fixingflame proof Weatherproof Control Panel MCB DB in Cast Alluminium alloy LM6 Construction Cat No. MCDB /186. Certified by CMRS Dhanbad for Group IIA & IIB. 01 No of 6 A DP MCB as a incommer and 01 Nos of 6 A SP MCB as a outgoingwith common Neutral link, Earth bar, including fixing to wall complete all as specified and directed. |
| 19 | Supply and fixing modular metal flush box made out of GI sheet, thickness not less than 1.2mm with earthing terminal, 8 module complete all as specified and directed. |
| 20 | Supply and fixing modular metal flush box made out of GI sheet, thickness not less than 1.2mm with earthing terminal, 12 module complete all as specified and directed. |
| 21 | Supply and fixing modular white cover plate with frame ,12 module complete all as specified and directed. |
| 22 | Supply and fixing modular Dummy plate complete all as specified and directed. |
| 23 | Supply and fix TV Socket and connector complete with all necessary fitting complete all as specified and directed. |
| 24 | Supply and fix sheet metal enclosure for DB’s (Double door type) when MCB’s to be used, single pole and neutral, 6ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wallwith IP-43 and IK-09 protection complete all as specified and directed. |
| 25 | Supply and fixing VTPN DB 4 way, Double door, 415 V, IP 43, suitable size and length of CRCA sheet steel, dust protection, duly powder painted, inclusive factory fitted suitable size copper Bus bar,01 No of MCCB as a incommer and TP/TPN/SPN/SP as outgoing with common Neutral link, Earth bar, Din bar for mounting of MCBs and blanking plate including fixing to wall complete all as specified and directed. |
| 26 | Supply and fixing LED tube light fitting in Extruded Aluminium housing for all purpose surface and wall mounted with single side connection polycarbonateLED batten with polycarbonate housing and integrated electronic driver of capacity 20 W, four feetand connection with PVC insulalted twin core 23/0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed. |
| 27 | Supply and fix wall /ceiling mounting LED 9/10 Watt tube light fitting in Extruded Aluminium housing and integrated electronic driver complete withall acessories 1x9/10 Watt LED ,two feet with CCT of 6000k suitable for domestic application, 240 Volts, 50 Hz,and internally pre-wired with 1.5 Sqmm twin twisted flexible cable copper conductor and connection complete all as specified and directed. |
| 28 | Supply and fixing in replacement of LED tube light fitting for all purpose surface and wall mounted with single side connection polycarbonateLED batten in Extruded Aluminium housing and integrated electronic driver of capacity 36/40 W, four feetand connection with PVC insulalted twin core 23/0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed. |
| 29 | Supply and fix bldg street fitting made up of pressure dai cast aluminum housing with high efficiency LEDs as a lighting source and lens embedded PC Cover Having TOP opening seperate driver compartment with IP 66 protection and impact resistance of IK07, CCT 5700 K, of wattage 25 Wattincluding connection with 3 core PVC insulated overall sheathed flexible cable with multi stranded copper conductor of size not less than 1.0 sq mm from celing rose to fitting terminalall as specified and as directed. |
| 30 | Supply and FixingGI pipe bracket made out of GI pipe light grade 32 mm dia and bend to shape 1.5 mtr long MS clamps made out of MS flat iron (02 Nos) of size 32 x 4 mm thick compitable with bldg security light mentioned in item ser No. 61 with nuts & bolts, washers fixed to wall/pole at specified height complete all as specified and directed. |
| 31 | Supply and fixstudy lamp , Aluminium base body flush mount 6/7 watt LEDfixed on wall at suitable height all as specified and directed. |
| 32 | Supply and fixing LED tube light fitting Suspended mounted Linear down Light Luminaire with enclouser made of heavy gaugeExtruded Aluminium housing with PC diffuser with IP 20 including Jointing accessories and suspension kits for of capacity 20 W ,and connection with PVC insulalted twin core 23/0.0076 twisted copper cable from ceiling rose to LED light fitting complete all as specified and directed. |
| 33 | Supply and fixing LED Porch light tube light fitting Suspended mounted Linear down Light Luminaire with enclouser made of heavy gauge Extruded Aluminium housing with PC diffuser with IP 20 including Jointing accessories and suspension kits for of capacity 2x20W, and connection with PVC insulalted twin core 23/0.0076 twisted copper cable from ceiling rose to LED light fitting complete all as specified and directed. |
| 34 | Supply and fixing Heavy duty, Turboforce Exhaust fans 300 mm sweep, 1400 RPM, 1710 cub mtr/hour air delivery with of corrosion resistant body, minimal nosie operation and maintenace free design, totally enclosed, high efficient heavy duty motor with pressure die cast aluminium rotor mounted on two ball bearings, aerodynamically contoured blades, handle maximum air with minium power consumption, rigid frame with rubber mountings for silent operation conforming to IS 2313-1967 single phase, IP 55including circular hole shall be provide in the wall to suit the size of the frame which shall be fixed by means of rag bolts embedded in the wall. The hole shall be neatly plastered to the original finish of the wall and connected with and including three core 1.5 Sqmm, PVC insulated but unsheathed FRLS cable with multistranded copper conductors from ceiling rose to fan complete all as specified and directed. |
| 35 | Supply and fix Kitchan Chimney Dry Heat Auto Clean Technology Stainless with Air outlet 150 mm, Steel Finish Front Matte Black Glass panel with Digtal Display Touch Control Panel with 9 Speed Gesture motion, Heavy Duty Baffle Filters , minimium Air flow 1480 M3/h Energy Saving LED Light of suitable wattage , Copper winding BLDC Motor, 59dba max noise level and voltage 220-240 V/50 Hz including making hole in the wall and making good the distubed surface of wall incl. all accessories all as specified and directed. |
| 36 | INTERNAL WATER SUPPLY WORKS |
| 37 | Supply and fixing 15mm bore long body bip taps, cast copper alloy chromium plated with capstan head, screwed for iron pipe and fixed complete all as directed |
| 38 | Supply and fixing 15mm shower rose chromium plated fancy type, screwed down with iron pipes incl all fittings and fixed complete all as specified and directed. |
| 39 | Supply and fixing 15mm CP water jet for EWC with screwed both ends with all fittings and fixed complete all as specified and directed. |
| 40 | COMPOUND WALL |
| 41 | Material & Labour for 25mm thick bitumen filler for crumple joint in column complete all as specified and directed. |
| 42 | ROAD, PATH AND CULVERTS |
| 43 | Supply and fixing informatory board of size 0.9m x 0.6m made out of 2mm thick aluminium sheet with frame of stainless steel rectangular pipes 25 x 15mm and outer border of stainless pipe 35mm dia and each side with marking on both sides with retro reflective high intensity sheet 400 micron thick blue colour and pasted with heating process. The letters shall be 75mm to 100mm high of white colour cut to shape with special plotter and in proper manner. The board shall be fixed with 02 Nos stainless steel pipes of dia 75mm of 304 graded glossy finish with MS plate 3mm thick welded at bottom of pipes and board shall be fixed at height of 3.00 metre (Top level of board) above GL and embedded and grouted in ground in cement concrete (1:2:4) type B-1 including necessary excavation and earth work complete all as specified and directed. |
| 44 | EXTERNAL WATER SUPPLY WORKS |
| 45 | Material and labour for construction of valve pit of size 1200mm x 1200mm x 1200mm (internal dimensions) brick construction, including all necessary excavation and earth work in any type of soil, returning, filling in, disposal of surplus spoil to distance not exceeding 50m and depositing where directed, PCC in foundation of the mix (1:2:4) type B-2, brick masonry in cement mortar (1:4), 12mm thick rendering in cement mortar (1:4) internally finished even and fair and pointing flush externally as the work proceeds in the same mortar. Mild steel angle iron 40 x 40 x 6mm frame MS sheet cover 3.15mm thick with handle and locking arrangement, painting all the exposed MS work with two coats of synthetic enamel paint of the that as approved by the GE over a coat of red oxide primer and painting all the MSwork embedded in PCC with two coats of black bituminous paint complete all as specified and shown on drawing. |
| 46 | All as per description of Srl item No 7.01 above but of size 900mm x 900mm x 900mm complete all as specified and directed. |
| 47 | Material and labour for cutting old cast iron/MS/DI pipes and reducing to required length, in position, for insertion of new tees, branches etc for repair works, complete all as specified and directed by Engr-in-Charge suitable for the 150mm bore of pipes all as specified and directed. Note:- DI fittings measured in other item of schedule. |
| 48 | Material and labour for boring hole of size 200mm under the road/pavement/hard standing of any width with the help of trenchless technology using ultra sound technique and necessary machine not less thatn one metre below ground level complete all as specified and directed. |
| 49 | EXTERNAL ELECTRIC SUPPLY WORKS |
| 50 | Supply, installation, testing and commissioning of LT panel, outdoor type weather and vermin proof totally enclosed made out of 3.15mm thick CRCA sheet machine pressed of suitable size having min depth 500mm, to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear openable with locking arrangement three hinges min for each leaf, heavy sliding bolts on front and rear doors incl inner shutters for mounting switch gears etc, removable bottom gland plate of 3.15mm thickness with sufficient number of circular cable entry holes. LT panel shall have FRONT & REAR side marking on doors, DANGER sign board. All MCCBs, outgoing feeders shall be provided with extension links/ spreader linkson both sides. The connection from main bus bar to MCCB incommer side should be through bus bar only. LT panel shall be prewired complete duly powder coated with 7 tank process with angle iron iron frame of size 50 x 50 x 6mm of min height 1000mm fixed in PCC (1:2:4) complete comprising with following complete all as specified:-(a) Bus bar made of copper suitable for copper suitable for capacity 400 Amps considering current carrying capacity of 1.5 Amp/Sqmm coloured with heat shrinkable sleeves in four colours (Red/Yellow, blue and black) fixed on porcleain insulator with necessary nuts, bolts and washers etc. INCOMING:-(a) MCCB 250 Amp, 415 V, 36 KA, 4 pole with adj.thermal magnetic release ICS=100% ICU = 01 No.(b) Multifunction meter with LCD display, accuracy class 1.0 having parameters KW, KWh/KVA, KVAh/KVAr/KVArh & PF duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete - 01 No.(c) Indicator with neon lamps for RYB, 3 Phase - 01 Set.OUTGOING:-(a) MCB 40 Amp, SPN 220V, 10 KA= 06 Nos.(b) MCCB 160 Amp, 415 V, 25 KA, 4 pole with thermal magnetic release ICS=100% ICU = 01 No.(c) Spare space for 125 A, 4P MCCB - 01 Set.(d) Astronomical street light timer with MCB TPN 32 Amp, contactor 3 pole & SPN 32 A to override - 01 No.Note:- LT Panel confirming to IS-5039 of 1983 factory fabricated prewired made out of 3.15mm thick CRCA MS Sheet outdoor type having IP-65 protection. |
| 51 | Supply, installation, testing and commissioning of LT panel, outdoor type weather and vermin proof totally enclosed made out of 3.15mm thick CRCA sheet machine pressed of suitable size having min depth 500mm, to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear openable with locking arrangement three hinges min for each leaf, heavy sliding bolts on front and rear doors incl inner shutters for mounting switch gears etc, removable bottom gland plate of 3.15mm thickness with sufficient number of circular cable entry holes. LT panel shall have FRONT & REAR side marking on doors, DANGER sign board. All MCCBs, outgoing feeders shall be provided with extension links/ spreader linkson both sides. The connection from main bus bar to MCCB incommer side should be through bus bar only. LT panel shall be prewired complete duly powder coated with 7 tank process with angle iron iron frame of size 50 x 50 x 6mm of min height 1000mm fixed in PCC (1:2:4) complete comprising with following complete all as specified:-(a) Bus bar made of copper suitable for copper suitable for capacity 300 Amps considering current carrying capacity of 1.5 Amp/Sqmm coloured with heat shrinkable sleeves in four colours (Red/Yellow, blue and black) fixed on porcleain insulator with necessary nuts, bolts and washers etc. INCOMING:-(a) MCCB 160 Amp, 415 V, 25 KA, 4 pole with adj thermal magnetic release ICS=100% ICU = 01 No.(b) Multifunction meter with LCD display, accuracy class 1.0 having parameters KW, KWh/KVA, KVAh/KVAr/KVArh & PF duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete - 01 No.(c) Indicator with neon lamps for RYB - 01 Set.OUTGOING:-(a) MCCB 100 Amp, 415 v, 16 KA, 4 pole with adjustable thermal magentic release ICS=100% ICU = 01 No.(b) MCCB 63 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release ICS=100% ICU = 02 Nos.(c) MCCB SPN 40 Amp, 415 V - 04 Nos.(d) Astronomical street light timer with MCB TPN 32 Amp, contactor 3 pole & SPN 32 A to override - 01 No.Note:- LT Panel confirming to IS-5039 of 1983 factory fabricated prewired made out of 3.15mm thick CRCA MS Sheet outdoor type having IP-65 protection. |
| 52 | Supply and installation hot dip galvanized octagonal poles 7m long top Dia (A/F) 70mm approx, bottom dia (A/F) 130/135mm approx having sheet thickness 3mm base plate 200 x 200 x 12mm approx (LxBxT) including bolt size 4 x 20mm (no x dia), 200mm pitch circledia , 600mm bolt length, 100mm projected bolt length and having door opening of size 80 x 500mm above from GL and having hot dip galvanized single arm plane bracket 1000mm long made of 48.3mm outer dia for pole having top 70mm A/F, for mounting street light fitting fixed on top with nut and bolt washers including provision of cable connector for three phase supply and one no MCB SP of 0.5 A to 6 A complete along with required foundation as per OEM drawing, necessary excavation, returning, removal, earthwork, PCC, RCC with iron work all as specified and directed. Make : Bajaj Model No BOP-7030 or equivalent make of Surya, HPL, Crompton. |
| 53 | Supply and fixing of PVC insulated PVC sheathed three core copper conductor 1100 volt grade of size 1.0 Sqmm drawing through octagonal pole for connection purpose complete all as specified and directed. |
| 54 | Supply and fixing LED street light luminaire of 45 watt in epoxy/powder coated pressure die-cast aluminium housing heat resistant toughened clear glass/polycarbonate cover fixed with SS screws controlled with potted CVCC type, BIS marked electronic driver duly enclosed of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lighttening of 5 KV minimum in circuit and 10 KV outside the driver but inside the fixture with IP-66, Class-1 protection for LED and control gear compartments with higher power LED chips of rating 2.5 to 3 watt (minimum) make Osram/Nishia/Cree/Philips with colour temperature 5700 K (max) and with secondary optics modular independent lenses provided with casing and caping to minimize glare and for better distribution of light suitable for voltage band 120 votls to 277 volt, power factor 0.95 (minimum) having efficacy 100 lumens/watt complete all as specified and directed. Make : Surya/Crompton/Havells/Polycab/Osram/Philips. |
| 55 | Material and labour for boring hole under the road/pavement/hard standing of any width with the help of trenchless technology using ultra sound technique and necessary machine and including HDPE pipe 100 mm of size not less than one metre below ground level complete all as specified and directed. |
| 56 | RAIN WATER HARVESTING WORKS |
| 57 | Material and labour for trial bore in normal available strata (size 200mm and above) upto 50mtr depth complete all as specified |
| 58 | Material and labour for trial bore in normal available strata (size 200mm and above) exc 50 mtr but not exc 75mtr depth complete all as specified |
| 59 | Supply and fixing PVC (SWR) pipe 160mm dia 1st quality single socketed in any length with rubber ring joint incl all necessary fitting laid in trenches or in floors complete all as specified |
| 60 | Supply and fixing PVC (SWR) pipe 160mm dia slotted/perforated 1st quality single socketed in any length with rubber ring joint incl all necessary fitting laid in trenches or in floors complete all as specified |
| 61 | Material and labour forfilling coarse sand in trenches laid in layers, complete all as specified and directed. |
| 62 | Material and labour for gravel packing incl jute as filter media 4mm to 6mm size around the PVC pipe complete all as specified and directed. |
| 63 | Material and labour for filling of gravel in trenches of size 6mm to 10mm, complete all as specified and directed. |
| 64 | Material and labour for filling of gravel in trenches of size 2mm to 4mm, complete all as specified and directed. |
| 65 | SUMMER APPLIANCES WORKS |
| 66 | Supply and fixing EVAPORATIVE desert cooler electric driven (single phase) of capacity 4000 cum/hr having water storage capacity min 100 litre with steel body made out of sheet 18SWG for main body and 22 SWG for side covers duly super enamelled painted with two coatsof superior quality over a coat of red oxide primer complete inner and outer sides with front grill made out of steel (heavy duty) propeller coller fan (aluminum blades) 500mm sweep dia with heavy duty motor (3 speed), AC single phase 230 Volts, 50c/s, copper wound with water pump including flexible PVC connections pipe of 15mm dia float valve, connection nipple complete all as specified and directed. |
| 67 | Supply and fixing desert cooler stand made of angle iron of size 25 x 25 x 3mm after cutting, welding, painting dual coated with synthetic enamel paint over one coat of red oxide primer and duly grouted in wall complete with stud/rag bolts complete incl making good disturbed surfaces complete all as specified and directed. |
| 68 | Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 Vto 280 V with output voltage stabilized at 230 Vof capacity 12 Amp rating complete all as specified and directed. |
| 69 | AIR CONDITIONING |
| 70 | Supply, install hi wall inverter type split AC units indoor & outdoorunit complete with cooper piping having insulation sleeves any length reqd at site, copper cable, any stand reqd for outdoor unit complete with cordless remote control unit and with minimum 5 star rating capacity 2.0 TR complete all as specified and directed. |
| 71 | Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250v with output voltage stabilized at 230v of capacity 15 Amp complete all as specified and directed. |