| 1 | Building |
| 2 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.(a) In ground floor including roof. |
| 3 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. |
| 4 | Earth work in excavation from foundation trenches in any kind and depositing the spoils within av. Lead & lift in/c. all etc.complete |
| 5 | Filling in foundation or plinth by silver sand in layer not exceeding 150mm as directed and cosolidating same by through saturation with water ramming etc complete including the cost of sand ( payment to be made on measurement of finished quantity |
| 6 | Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. |
| 7 | (I) Cement concrete with graded stone ballast (40 mm. size) excluding shuttering. (A) In ground floor (a) 6:3:1 proportion |
| 8 | Ordinary Cement Concrete (mix 3:1.5:1) with graded stone chips (20 mm.down) excluding shuttering and reinforcement, if any, in ground floor. as per IS 456- 2000 |
| 9 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.(JSW/JSPL/SHYAM/SRMB/BMASL/ELECTRO STEEL/ SSL) Lead- 45km (a) For works in foundation, basement and upto roof of ground floor / upto 4m. (i) Tor steel/Mild steel |
| 10 | Hire and labour charges for shuttering with centering and necessary staging up to 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs beams columns lintals curved or straight in/c fitting fixing &stricking out after completion of works (up to roof of ground floor |
| 11 | With Staging |
| 12 | Brick work with 1st class bricks in cement mortar (6:1)(a) In foundation and plinth |
| 13 | (b) In superstructure, ground floor |
| 14 | Plastering (to wall, floor,celling etc.) with sand cement morter including rounding off or chamffering corners as directed and racking out joints or roughening of concrete surface including throating, nosing and drip course where necessary.In ground floor .A) Ceilling other conc. surface plaster 10 mm thick a) With ( 4:1) sand cement morter |
| 15 | B) Inside surface wall plaster 20mm thick a) With( 6:1) sand cement morter |
| 16 | C) Outside surface wall plaster 15mm thick a) With (6:1) sand cement morter.Out side wall of Building |
| 17 | Neat cement punning about 1.50mm thick in wall,dado window sill etc all complete |
| 18 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement |
| 19 | A) Supplying fitting and fixing door frame with M.S. angle as per drawing &direction of required section.The holes for counter sunk machine screw & nutswill be such as to fit 8 to 10 mm Iron screw. The counter sunk nut to be welded .The nuts are to be welded after careful checking with screw.All welding spotsshould be properly filed or rounded smooth including cost of welding hinges forhinge cleats , lugs for hasp bolt, socket bolt etc. and necessary M.S. clamps of25mm x 6mm flat 225mm long as per direction welded to the frame fitted andfixed in position excluding cost of concrete. 7.85 gm/Cu.cm |
| 20 | . Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both aces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost ofall labour and materials. |
| 21 | M.S. or W.I. ornamental grill of approved design joints continuously welded with M.S or W.I flats and bars of window , railing, etc fitted and fixed with necesssary screws and lugs in gr floor. |
| 22 | Page no -212 item no-21(i). Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. (i) 75 mm. Dia. |
| 23 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).(d) Sal : Local |
| 24 | Z-batten shutters of door and window as per design havings tongued and groovehalf lap jointed as per direction of the Engineer-in-Charge including fitting and fixing shutter in position, but excluding the cost of hinges and other fittings in ground floor. (A) Shutter with 25mm thick planks, 19mm thick battens.(iv) Other Local Wood |
| 25 | Applying White Wash of approved quality after preparing the surface including scrapping the same thoroughly (plastered or concrete surface) as per Direction of E -in C In ground floor. (Stone lime: shell lime= 5:1) For Two coat,Area =( Total inside plastered area-Net Cement Area) Same as inside plaster.(c) Three coats (on new works only). |
| 26 | .Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer\"s specification. Same as out side plaster.(iii) Two coats. |
| 27 | Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised dhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top Surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer\"s specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor)With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment(A) Deep Colour & White |
| 28 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. WALL With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.mArea of each tile upto 0.09 Sq.m |
| 29 | ADD FOR GST @ 18% |
| 30 | ADD FOR CESS @ 1% Please Enable Macros to View BoQ information |