| 1 | CIVILWORKS |
| 2 | 50.10.2Steel work for purlin/single section with G I pipes including cutting, hoisting, fixingin position and applying a priming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete |
| 3 | OD114214/2025-2026Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade,5-7 microns epoxy primer on both side. of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoidscratches during transportation and should be supplied in single length upto 12 metreor as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/selftapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch inhorizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters andtrusses and including cutting to size and shape wherever required. |
| 4 | 13.61.1Painting with synthetic enamel paint of approved brand and manufacture to give aneven shade:Two or more coats on new work |
| 5 | 21.1.1.2Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron) |
| 6 | 21.1.2.2For shutters of doors, windows & ventilators including providing and fixing hinges /pivots and making provision for fixing of fittings wherever required including thecost of EPDM rubber/ neoprene gasket required (Fittings shall be paid forseparately)Powder coated aluminium (minimum thickness of powder coating 50micron) |
| 7 | 21.3.1Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness (weight not less than 10kg/sqm) |
| 8 | 11.41.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints w |
| 9 | OD114409/2025-2026Providing and fixing wall paneling and false ceiling with 10 mm thick TKT PVCboard of approved quality including frame work with necessary screws etc. complete. |
| 10 | 13.98.1Wall painting with plastic emulsion paint of approved brand and manufacture to givean even shade:One or more coats on old work |
| 11 | 4.1.5Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 12 | OD156811/2025-2026Supply providing and fixing ACP with necessary fittings etc complete |
| 13 | OD114581/2025-2026Engaging Man Labour; Plumber |
| 14 | OD114587/2025-2026Supply and fixing PVC Door of standard size including conveyance , fixing, finishingetc. complete |
| 15 | 11.37Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to bespecified by the manufacturer) of 1st quality conforming to IS : 15622 of approvedmake in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thickcement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @3.3 kg/sqm including pointing the joints with white cement and matching pigmentetc., complete |
| 16 | 8.31Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer-inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete. |
| 17 | 22.5Providing and laying water proofing treatment in sunken portion of WCs, bathroometc., by applying cement slurry mixed with water proofing cement compoundconsisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed withwater proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to aircure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed withwater proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to aircure for 4 hours followed with water curing for 48 hours. The rate includespreparation of surface, treatment and sealing of all joints, corners, junctions of pipesand masonry with polymer mixed slurry |
| 18 | 11.48.2Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 600x600 mm |
| 19 | 9.101.2Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised(anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to |
| 20 | 21.13Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pairof handles ( best make of approved quality ) for aluminum doors including necessarycutting and making good etc. complete |
| 21 | 21.3.2Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 5.50mm thickness (weight not less than 12.50 kg/sqm) |
| 22 | 9.100.2Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:100 mm |
| 23 | 9.83Providing and fixing aluminium die cast body tubular type universal hydraulic doorcloser (having brand logo with ISI, IS : 3564, embossed on the body, door weightupto 35 kg and door width upto 700 mm), with necessary accessories and screws etc.complete. |
| 24 | 15.23.1Dismantling tile work in floors and roofs laid in cement mortar including stackingmaterial within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 25 | 21.2.2Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panellingfixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre- laminated particle board with decorative lamination onboth sides |
| 26 | OD159670/2025-2026Engaging Man Labour ; Coolie |
| 27 | WATER SUPPLY AND SANITARY WORK |
| 28 | 17.18.1Providing and fixing P.V.C. low level flushing cistern with manually controlleddevice (handle lever) conforming to IS: 7231, with all fittings and fixturescomplete.10 litre capacity - White |
| 29 | 17.20.1Providing and fixing solid plastic Seat with lid for pedestal type W.C. pancomplete:White solid plastic seat with lid |
| 30 | 50.18.8.3.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 25 mm pipe10kgf /cm2 |
| 31 | 50.17.1.4Supplying and fixing CP Health faucet good quality including cost of materials andlabour charges etc. complete as per the direction of site engineer-in-charge. |
| 32 | 50.18.8.9.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 |
| 33 | 50.18.7.6.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing . This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 6 Kgf/cm2 - Internal work- Exposed on wall |
| 34 | OD157571/2025-2026Providing and fixing C.P. brass long body bib cock (Jaguar or equivalent )ofapproved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 35 | OD157574/2025-2026Providing and fixing Overhead Brass type Shower arm having size 305mm oravailable nearby size with wall flange using brandCera,Hindware,jaguar,parryware,somany for aluminum doors including necessary cutting and making good etc. complete |
| 36 | OD157575/2025-2026Providing and fixing Overhead Rain Shower Square (ABS) having size 150*150mmor available nearby size using brand Cera,Hindware,jaguar,parryware,somany |
| 37 | Electrical Works |
| 38 | 1.10.1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A |
| 39 | 1.10.2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B |
| 40 | 1.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 41 | 1.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm |
| 42 | 1.21.2Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.25 mm |
| 43 | 1.17.1Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x1.5 sq. mm |
| 44 | 1.17.2Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x1.5 sq. mm |
| 45 | 1.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X1.5 sq.mm |
| 46 | 1.17.12Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x2.5 sq. mm |
| 47 | 1.17.21Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x4 sq. mm |
| 48 | 1.24.1Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.5/6amps switch |
| 49 | 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.3pin 5/6 amp socket outlet |
| 50 | 90.10.3.15Supply and Fixing the following modular switches & accessories in the existing frontplates and giving necessary connections as required (RoHS compliant )32A DPswitch with indicator |
| 51 | 90.10.3.33Supply and Fixing the following modular switches & accessories in the existing frontplates and giving necessary connections as required (RoHS compliant )25A 3pinShuttered socket |
| 52 | 1.25Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box including connections but excluding modular plate etc. asrequired. |
| 53 | 1.26Supplying and fixing modular blanking plate on the existing modular plate & switchbox excluding modular plate as required. |
| 54 | 1.32Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modularsocket outlet and 15/16 amps modular switch, connection etc. as required. |
| 55 | 1.56Supplying and fixing suitable size Gl box with modular plate and cover in front onsurface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socketoutlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For lightplugs to be used in non residential buildings). |
| 56 | 1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.1 or 2 Module(75mmX75mm) |
| 57 | 1.27.4Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 58 | 1.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ woodenblock including connection etc as required. |
| 59 | 1.58Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 60 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \"\"C\"\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 61 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 62 | 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 ampsN |
| 63 | 2.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 64 | 1.53.1Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existingsurface/recessed steel/PVC conduit as required1 run of Cable |
| 65 | OD144030/2025-2026Supply, Installation, testing and commissioning of Keystone for Network point in theexistingcover plate |
| 66 | 90.4.2Supply and installation of suitable size MS belt type fan clamp fabricated from flatiron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly paintedwith 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required. |
| 67 | 90.4.5.4Supply, Installation, testing and commissioning of ceiling fan of following sizesincluding wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mmFRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cubmeter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper windingsuitable for 230V/240V single phase AC supply |
| 68 | OD144031/2025-2026 Supply and providing 9W LED Bulb of department approved make in the existing batten holder |
| 69 | OD144032/2025-2026Supply, Installation , Testing and Commissioning of Surface mounting LED 20WLED Batten with out put 2000 lumen for use on 250V AC supply |
| 70 | OD144033/2025-2026Supply, installation, testing and commissioning of 400mm sweep wall fan withenergy efficient motor ,giving connection etc complete as required |
| 71 | OD144034/2025-2026Labour charges for Electrician |