Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 04-11-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 11-11-2025 |
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar rendering , bedding , and making good wall/ floor surface for laying backing coat/ PCC ,removing serviceable tiles to store and disposal of rubbish at location complete all as specified and directed by Engineer Incharge.(Note :- The cost of making good damaged sufaces of wall/ floor and removal of material to be included in quoted rate and nothing shall be admissible on this account) |
| 2 | Demolition of cement concrete unreinforced of any description and in any position not otherwise specially provided and disposal of rubbish at location complete all as specified and directed by Engineer Incharge.(Note :- The cost of Removal of material outside of MD land deemed to be included in quoted rate and nothing shall be admissible on this account) |
| 3 | M&L for 40mm thick plain cementconcretetype B-1, 1:2:4 (20mm graded stone aggregate) as in sub base of floors complete all as specified and directed by Engineer Incharge. |
| 4 | M&L for Full body Glazed Vitrified tiles 9 to 10 mm thick light shade (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 Sqm (600mm x 1200mm) , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed by Engineer Incharge.Note :- 8 to 10mm thick gypsum powder slurry will be laid over tiles to avoid scratch, damage, paint marks etc during construction work. The cost of laying gypsum powder slurry deemed to be included in quoted rate and nothing shall be admissible on this account. |
| 5 | M&L for Full bodyGlazed Vitrified tiles 9 to 10 mm thick shade/ colour as approved by Garrison Engineer (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 Sqm (600mm x 1200mm) , as in dado/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat in cement mortar (1:4)complete all as specified and directed by Engineer Incharge. |
| 6 | M&L for Plugging to brick walls complete for second class hard wood fillets, grounds, moulding, boarding etc at distance n.exc 1 m in brick walls/stone wall/PCC block walling complete all as specified and directed by Engineer Incharge. |
| 7 | M&L for IInd class hardwoodplain fillets section exc 13 Sqcm but not exc 25 Sqcm ,square,rectungular or tringular in section ,clean sawn ,secured with nails or brads for unframed work complete all as specified and directed by Engineer Incharge. |
| 8 | M&L for 12 mm thickply wood grade BWR, 7 ply, type BB fixed with screws to timber frame work with screws to timber frame work complete all as specified and directed by Engineer Incharge. |
| 9 | M&L for 3mm thick veneered 3 plydecorative ply wood, grade-I (with BWR resin) with decorative face veneers on one face fixed with fevicol to plywood work complete all as specified and directed by Engineer Incharge. |
| 10 | M&L for first class hardwood moulding, cornices plain fillets section exc 6 Sqcm but not exc 13 Sqcm ,square,rectungular or triangular in section ,clean sawn ,secured with nails or brads for unframed work fixed with screws (mouldings not exc 75mm girth with carving work including) complete all as specified and directed by Engineer Incharge. |
| 11 | M&L for applying two coats of Melamine polish over and including two coats of melamine sealer and one coat of wood stain on new wall panelling surfaces/ wooden surfaces using spray gun etc till fine glossy filnish is obtained including filling cracks and holes with filler material as required complete all as specified and directed by Engineer Incharge.Application procedure – (a) Staining – For staining, apply wood stain and allow it dry for 30 minutes. Do not sand the stained coat. (b) Sealing – Mix melamine sealer base and hardener in the ratio 90:10 by volume and thin it with 20-40% of thinner for spraying. Allow a maturation time 30 minutes and use within 8 hours. Spray 2 coats of sealer. For spraying, give an intercoat interval of 5-6 hours. Sand with emery paper 320 or 400 between coats. (c) Top Coat – Mix the melamine base and hardener in the ratio 90:10 by volume and thin it with 20-40% of thinner for spraying. Allow a maturation time 30 minutes and use within 8 hours. Spray 2 coats of melamine glossy. For spraying, give an intercoat interval of 5-6 hours. Sand with emery paper 320 or 400 between coats. |
| 12 | M&Lfor providing and fixing Gypsum board 12mm thick in ceiling ncluding all architectural design/work like mouldings ,cornices, coves, domes, cups as per detailed drawings or as directed by Engineer in charge fixed to Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including thin layer of putty with gypsum binder, sanding the sufrace till smooth surface is obtained and applying two coats of acrylic emulsion distemper over and including a coat of primer complete all as specified and directed by Engineer Incharge. |
| 13 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons, steps , risers etc laid beddedpointed in any mortar, making good wall/ floor surface for laying backing coat/ PCC ,removing serviceable Slab/tiles to store and disposal of rubbish at location complete all as specified and directed by Engineer Incharge.(Note :- The cost of making good damaged sufaces of wall/ floor and removal of material to be included in quoted rate and nothing shall be admissible on this account. |
| 14 | M&L for Light/ Dark shade Granite 18 to 20mm thick colour in leather finish for top surface of steps tread, skid surface etc with three grooved lines. machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 20 mm thick screed bed in cement mortar (1:6)complete all as specified and directed by Engineer Incharge. |
| 15 | M&L for Light/ Dark shade Granite 18 to 20mm thick colourmachine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 10 mm thick backing coat in cement mortar (1:4)complete all as specified and directed by Engineer Incharge. |
| 16 | M&L Aluminium Compostie panel in metalic/glossy finish as approved by Garrison Engineer, cut to shape required made out of 3mm thick aluminium composite panel material comprising of 2.5 mm thick FR grade mineral core sandwiched between two aluminium sheets (each 0.25 mm thick) using stainless steelscrews , nuts , bolts, washers, cleats, weather silicon sealant, backer rods etc all as specified and as directed. |
| 17 | S&F Anodised aluminium frame work for ACP panel and like with one or more rebates, screw, anchor bolt, joining cleat etc. complete all as specified and as directed. |
| 18 | M&L for20 mm average thickness of screed layer on RCC slab in cement mortar ( 1:4) including liquid water proofing(Note :- Water proofing compound will be measured and paid separately) |
| 19 | M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces with using water liquid proofing compound and finishing the surface even & smooth without using extra cementcomplete all as specified and directed by Engineer Incharge.Note:- The water proofing compound will be measured and paid separately. |
| 20 | M&L for water proofing treatment to RCC roof slab, walls, chajjas etc, including taking down of existing un-serviceable water proofing treatment of any description/ bituminous membrane and taking down existing plaser on roof and parapet of any roof height including preparation of surfaces carefully by cutting chiseling, cleaning the surface by scrapping, brooming brushing etc, to receive the new plaster as discribed below and removing and removing the rubbish from site shall be carried out as specified below andcomplete all as specified and directed by Engineer Incharge including following:-(a) Proving 10mm average thickness of screed layer on RCC roof slab in cement mortar (1:3) mixed with WPC or as recommended by manufacturer and the same shall be measured and paid in the unit rate quoted under this item. (b) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bitumous primer @0.4 Ltr/ Sqm of area complete all as specified. (c) Providing APP based polymeric modified approved membrane of min 3mm thick, non woven, polyster, weighing not less than 3.5kg/ sqm with laps & overlaps as specified & joints sealed and applied complete by torch application method all as specified & directed by Engr-in-charge. carrying out test by flooding water for 24 hrs for leakage & seepages and rectifying the same to the entire satisfaction of GE.(d) Finally applying two coats of solar reflective bituminous aluminium paint @ 0.10 ltr/sqm on the top of membrane surface complete all as specified and as directed by engineer incharge. |
| 21 | Supply only intergal water proofing compound |
| 22 | S&F 110 mm bore PVC (SWR) type B pipes single socketed, in any length with rubber ring joints, fixed to wall or laid in trenches complete all as specified and directed by Engineer Incharge. |
| 23 | S&F 110mm bore PVC (SWR) bendscomplete all as specified and directed by Engineer Incharge. |
| 24 | M&L for complete removal of existing treatment by mechanical means on plastered surfaces of walls and Providing and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litreand UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over plastered surfaces complete all as specified and directed by Engineer Incharge. |
| 25 | M&L for complete removal of existing treatment by mechanical means on plastered surfaces of walls and Providing and applying wall care putty of total 1.5mm thick in two layers over plastered surface to prepare the surface even and smooth, and applying two coats of acrylic emulsion distemper over and including a coat of primer complete all as specified and directed by Engineer Incharge. |
| 26 | M&L for complete removal of existing treatment by mechanical means on plastered surfaces of ceiling Providing and applying wall care puttyof total 1.5 mm thick in two layers over plastered surface to prepare the surface even and smooth, and applyingtwo coats of acrylic emulsion distemper over and including a coat of primer complete all as specified and directed by Engineer Incharge. |
| 27 | Surface excavation n.exc 30cm deep & averaging 15 cm deep and getting out in Hard / dense soilcomplete all as specified and directed by Engineer Incharge. |
| 28 | M&L for hard core broken stone or boulders n exc 63mm deposited spread and levelled in layers n exc 15cm thick watered and rammed to a true surface complete all as specified and directed by Engineer Incharge. |
| 29 | M&L for 75 mm thick Plain Cement concrete1:4:8type D- 2,(using 40mm graded stone aggregate) as in sub base complete all as specified and directed by Engineer Incharge. |
| 30 | M&L for rough dressed shahabad stone slab flooring(30 mm thick) including bedded and jointed in 10mm thick CM (1:6) and pointed in CM (1:3) complete all as specified and directed by Engineer Incharge. |
| 31 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer Incharge. |
| 32 | M&L for point wiring (Concealed wiring) of any length using approved colour coding as per IS and IE rule , withmulti stranded copper conductor 1.5 Sqmm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS-H cable,1100 volts grade, conf to IS:694, ISI markedin and includingPVC rigid conduits heavy duty, medium grade,ISI marked (Min 20mm dia )with valid CMLNo. totally concealed in wall/ floor and providing casing caping, ISI marked, not less than 20 mm diato be fix on roof/ ceiling including all accessories as requiredat site complete including GI Metal Flush box (sunken box of min 1.0 mm thick) with modular frame/cover plateof suitable sizefor mountingmodular switches/sockets etc and PVC insulatedmuti strandedFRLSH copper conductor 1.5 Sq.mm single core cable (Green colour) as earth conductor and connecting to common earth dolly complete all as specified and directed by Engineer in Charge for the following:- |
| 33 | One light point controlled by one switch one way type |
| 34 | One Exhaust fan point controlled by one switch one way type |
| 35 | One 3 pin 5 Amps socket outlet point on Same board |
| 36 | One 3 pin 5 Amps socket outlet point on independent board (including wall fan-10 Nos) |
| 37 | All as per item No 33 above but with 2.5 sq mm copper conductor FRLSH (multistrand), 1100 volts grade PVC insulated, ISI marked unsheathed cable in and including concealed PVC conduit heavy duty ,ISI marked, medium grade with valid CML No not less than 20 mm dia with all fitting & accessories as required and including PVC insulated ISI marked, unseathed, FRLSH copper conductor cable of size 2.5 s q mm (Green Colour) as earth wire to common earth dollyfor one three pin socket outlet 15 Amps complete all as specified and directed by Engineer Incharge. |
| 38 | Note for Item Sr No 33.01 to 33.04, 34i) The contractor shall providecircuit wiring with 3 x 2.5 Sqmmcopper wirefrom DB to switch board and rate for the same is deemed to be included in quoted rate of item.(ii) The cost of cutting in chases and pointing in brick wall/Stone Wall deemed to be included in quoted rate and nothing extra cost.on this account is admissible.(ii) Making good of distrubed surfaces matching with existing finishes shall be done by contractor without any extra cost.(iii) Contractor shall make the surface good after flushing the sunken box as existing without any extra cost(iv) The length of point wiring for light points/ fan points (ceiling/ exhaust / wall) shall be of suitable length as per site requirement and location of fittings and their switches as directed by Engr-in-charge. The cost of same shall deemed to be included in quoted rates. (v) The contractor shall provide wire mesh before plastering work on chase cutting to avoid cracks developed on surface.(vi) GI Sunken box and modular switch socket shall be of same make and sunken box shall be suitable for mounting modular switch and socket approved by GE.(vii) Wiring above false ceiling in hall where Provn of false ceiling made wiring to be done in surface PVC conduitand conduit to be fixed on wall by providing shaddles and clamps.(viii) The cost of provide blanking plate in modular switch board as per site requirement is deemed to be included in quoted rate and nothing extra on this account is admissible. |
| 39 | M&L for point wiring (Concealed wiring in existing concealed conduit) of any length using approved colour coding as per IS and IE rule , withmulti stranded copper conductor 1.5 Sqmm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS-H cable,1100 volts grade, conf to IS:694, ISI marked including GI Metal Flush box (sunken box of min 1.0mm thick) with modular frame/cover plateof suitable sizefor mountingmodular switches/sockets etc and PVC insulatedmuti strandedFRLSH copper conductor 1.5 Sq.mm single core cable (Green colour) as earth conductor and connecting to common earth dolly complete all as specified and directed by E in Charge for the following:- |
| 40 | (a) One light point controlled by one switch one way type |
| 41 | (b) One Ceiling fan/Exhaust fan point controlled by one switch one way type |
| 42 | (c)One 3 pin 5 Amps socket outlet point on Same board |
| 43 | (d) One 3 pin 5 Amps socket outlet point on independent board |
| 44 | All as per itemNo35 above butwith 2.5 sq mm copper conductor FRLSH (multistrand), 1100 volts grade PVC insulated, ISI marked, conf to IS 694,unsheathed cable in (existing concealed PVC conduit of any size) including GI Metal Flush box (sunken box of min 1.0mm thick) with modular frame/cover plateof suitable sizefor mountingmodular switches/sockets etc and PVC insulatedmuti strandedFRLSH copper conductor 2.5 Sq.mm single core cable (Green colour) as earth conductor and connecting to common earth dolly complete all as specified and directed by Engineer in Charge , for one three pin socket outlet 15 Amps. |
| 45 | Note for Item Sr No 35.01 to 35.04, 36(i) The cost ofprovidingcircuit wiring with 3 x 2.5 Sqmmcopper wirefrom DB to switch board is deemed to be included in quoted rateand nothing extra on this account is admissible.(ii) The cost of cutting in chases and pointing in brick wall/Stone Wall is deemed to be included in quoted rateand nothing extra on this account is admissible.(ii) Making good of distrubed surfaces matching with existing finishes is deemed to be included in quoted rateand nothing extra on this account is admissible.(iii) The cost of making the surface good after flushing the sunken box as existing is deemed to be included in quoted rateand nothing extra on this account is admissible.(iv) The length of point Wiring for light points/ fan points (ceiling/ exhaust / wall) shall be of suitable length as per site requirement and location of fittings and their switches as directed by Engr-in-charge. The cost of same shall deemed to be included in quoted rates. (v) The cost ofproviding blanking plate in modular switch board as per site requirement is deemed to be included in quoted rateand nothing extra on this account is admissible. |
| 46 | S&F modular switch, one way, 6 Amps, 230V, AC, one module, white colour complete all as specified and directed by Engineer Incharge. Make:- Anchor Roma plus series or techno commercial equivalent of make mentioned under appendix \"C\" to tender documents. |
| 47 | S&F modular socket 6 Amps 2/3 pin, 240 V, AC, two module, white colour complete all as specified and directed by Engineer Incharge.Make:- Anchor Roma plus series or techno commercial equivalent of make mentioned under appendix \"C\" to tender documents. |
| 48 | S&F modular switch, one way, 16 Amps, 230 V, AC,one module, white color complete all as specified and directed by Engineer Incharge.Make:- Anchor Roma plus series or techno commercial equivalent of make mentioned under appendix \"C\" to tender documents. |
| 49 | S&F modular socket 6 Amps /16 Amps 2/3 pin, 240 V, AC,two modulewhite color complete all as specified and directed by Engineer Incharge.Make:- Anchor Roma plus series or techno commercial equivalent of make mentioned under appendix \"C\" to tender documents. |
| 50 | S&F ceiling rose, 3 terminals / PVC / Polycarbonate, isolated body complete all as specified and directed by Engineer Incharge. |
| 51 | S&F LED Bulk head fitting 15 Watt, energy efficient wall mounted LED Bulk head luminaire madeof PDC Aluminium with Opal diffuser, IP 65 complete prewired, connecting light fitting to light source (ceiling rose) with sheathed three core flexible copper wire of sutiable size in PVC flexible pipe of 15 mm dia complete all as specified and directed by Engineer Incharge. |
| 52 | S&F LED Tube light fitting 10 Watt,Surface / wall mounted LED batten housing made of aluminium extrusion with high efficient LED`s, opel diffuser, IP 20, with system efficacy of 100 lm/W , colour temp 6500 K, 50 Hz, 240 V complete including all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable ofsuitable size from ceiling rose to connector of light fittings, incl 2 x PVC mounting box for fixing of light complete all as specified and directed by Engineer Incharge. |
| 53 | S & F LED Tube light fitting 22 watt, surface / wall mounted LED batten housing made of aluminium extrusion with high efficient LED`s, opel diffuser, IP 20, with system efficacy of 100 lm/W , colour temp 6500 K, 50 Hz, 240 V complete including all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable ofsuitable size from ceiling rose to connector of light fittings, incl 2 x PVC mounting box for fixing of light complete all as specified and directed by Engineer Incharge. |
| 54 | S&F Round recess (Al) down light 30 W, recess mounted pressure die-cast Aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation of 30W LED downlighter of(Warm white/Neutral white as per site requirement) , high efficient LED and Glare free opal diffuser, IP 20, system efficacy - 100lm/w etc prewired and including all accessories and connection of light fitting in false ceiling complete all as specified and directed by Engineer Incharge. |
| 55 | S&F Round recess (Al) down light 15W, recess mounted pressure die-cast Aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation of 15W LED downlighter of(Warm white/Neutral white as per site requirement) , high efficient LED and Glare free opal diffuser, IP 20, system efficacy - 100lm/w etc prewired and including all accessories and connection of light fitting in false ceiling complete all as specified and directed by Engineer Incharge. |
| 56 | S&F LED Security light fittings 35/36 Watt with PDC aluminium housing with energy efficient LEDs, Direct modular IP Lens, IP 66 with potted driver and with system efficacy of 125 lm/watt top opening separate driver compartment, IK 07 complete with all accessories such as MS flat iron clamp - 02 Nos , nut, bolts,light grade GI pipe mounting bracket min 32 mm dia of length upto 1.5 mtretc, prewired, connecting light fitting to light source (ceiling rose) with sheathed three core flexible copper wire of suitable size in PVC flexible pipe of 15 mm dia complete all as specified and directed by Engineer Incharge. |
| 57 | S&F surface mounted LED Panel light 30 W LED of size 300mm x 300mm x 35mm fabricated in CRCA sheet steel housing, duly powder coated with high efficent LEDs, glare freefull opal diffuser , 240 Volts, 50 HZ, colour temp 6500 K ,system efficacy - 100 lm/w suitable for ceiling, environmental friendly, new generation, energy saving, and separate replaceable electronic driver including connecting with three core wire, all acessories as required for fixing the light fitting and matching to the adjacent ceiling surfaces complete all as specified and directed by Engineer Incharge. |
| 58 | S&FLED Flood light, 50W, White,Energy saving , enviorment friendly, long life, made up of pressure die cast aluminium housing with toughened glass and high power LED`s and secondary lenses withIP 66 protection ,having system efficacy > 100 Lumen Per Watt inclusive of driver, 10 KV SPD and all acessories, Light fitting suitable for highlightingarchitectural facade and general purpose lightingsincludingproviding all fixing arrangements, studs , nut bolts, washers and flat iron clamp for fixing of light on PCC plateform / wall/ roofall as required at sitetohighlightingarchitectural facade/ trophycomplete all as specified and directed by Engineer Incharge. |
| 59 | S&F LED Flood light, 150W, White,Energy saving , enviorment friendly, long life, made up of pressure die cast aluminium housing with toughened glass and high power LED`s and secondary lenses withIP 66 protection ,having system efficacy > 100 Lumen Per Watt inclusive of driver, 10 KV SPD with 5 Years warranty and all acessories, Light fitting suitable for highlightingarchitectural facade and general purpose lightingsincludingproviding all fixing arrangements, studs , nut bolts, washers and flat iron clamp for fixing of light on PCC plateform/ wall or at any place as directedall as required at sitetohighlightingarchitectural facade/ trophycomplete all as specified and directed by Engineer Incharge. |
| 60 | S&FPicture light 07 Watt, LED Wall Picture Light 07 Watt, warm-white light, colortemp 3000k, individual LED lenses, bronze /golden coloured flexible neck for adjusting beam complete all as specified and directed by Engineer Incharge.Make:- Muziris Picture Light 7W (WW)or techno commercial equivalent of make mentioned under appendix \"C\" to tender documents. |
| 61 | S&F LED Strip Cove Lights (cut to required customisedlength, any length as per site requirement) and connecting with driver ,prewired and all accessories including fixing arrangements in false ceiling or any other celing / on picture frameor at any other locationcomplete all as specified and directed by Engineer Incharge.Make:- Havells Cat No LHEHDLP7UN1W024 or techno commercial equivalent of make mentioned under appendix \"C\" to tender documents.Note : The contractor shall provide LED strip light and driver of same make. |
| 62 | S&F LED Strip Cove Lights driver suitable for operating voltage 220-240 V AC with Output Voltage 24 V DC, Output Current 2.0 Amps, driver efficiency more than 75 %, ABS Plastic enclosure, FR Grade, surface mounting, over voltage protection, 2.5 kV surge protection, IP 20 rating, complete all as specified and directed by Engineer Incharge.Note : The contractor shall provide LED strip light and driver of same make. |
| 63 | S&F exhaust fan300 mm sweep, wall mounted, Grey colour, metal body with metal body louvers, 3 blade,heavy duty single phase suitable for 230 volts, 50 HZ,1400 RPM andair deilvery 1750 CMH,and connecting up complete including making electric connectionby providing 1.0 Sqmm x3 core flexible sheathed copper cable from ceiling rose to connector of fanin flexible PVC pipe of min 15 mm dia incl all acessories and including all fixing arrangement to fix onwall by making circular hole of suitable size incl all civil work, make good of surface as adjoining and providing all material required at site for installation of exhaust fan in toilet complete all as specified and directed by Engineer Incharge.Note : The contractor shall make all necessary arrangementfor fixing fan on wallby making opening including all civil work,make good of surface as adjoining and provide all material required on site (like Ply board/PVC board of min 6 mm thickas base etc for installation of exhaust fan and cost of the same is deemed to be included in quoted rate and nothing extra on this account is admissible. |
| 64 | S&F wall fan400 mm sweep, wall mounted, white colour,Jerk free & Smooth oscillation ,rust proof body, single phase suitable for 230 volts, 50 HZ,1350 RPM andair deilvery 65 CMM,and connecting up complete including making electric connectionand providing all material required at site for installation of Wall fan complete all as specified and directed by Engineer Incharge.Make:- Bajaj Model No-250552, Esteem 400mm or techno commercial equivalent of make mentioned under appendix \"C\" to tender documents. |
| 65 | Dismantling, disonnecting and taking down theexisting wall mounted fan carefully and depositing to MES Store complete all as specified and directed by Engineer Incharge. |
| 66 | S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated copper busbar, 8 way Double door enclosure made up of CRCA sheet steel, powder coated, IP 43,IK-09 as per IEC 61439-3, suitable for flush mounting and surface mounting, with neutral bar, earth bar and cable ties for cable management, fully shrouded neutral bar, prefitted masking sheet, reversible door including blanking plates and and fixing the DB box flush in wall of any type and making good the distrubed surface to match with the adjoining/ existing surfaces complete all as specified and directed by Engineer Incharge. |
| 67 | S&F MCB SPN 32 Amps, 240V,10 KA , C curve including complete with connection testing and commissioning complete all as specified and directed by Engineer Incharge. |
| 68 | S&F MCB SP 6 to 32 Amps 240V,10 KA, C curve, including complete with connection testing and commissioning complete all as specified and directed by Engineer Incharge. |
| 69 | S&F DB Box, in sheet metal enclosure DB VTPN, double door with MCCB as incomer(Suitable for mounting 100 Amp MCCB) and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with 250 Amp fully insulated copper bus bar for each phase, with 2 Neutral bar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, reversible door provision, blanking plates of and circuit identification labels, including flushing and fixing DB box neatly in wall / solid block wall including copper lugs/thimbles duly crimped for connection complete all as specified and directed by Engineer Incharge.Note: (i) MCCB and DB box shall be of same make. (ii) MCCB shall be measured & paid seperately |
| 70 | S&F MCCB with Thermal - magnetic release of 63 Amps, 4 Pole, 415V, 25 kA, Ics=100%lcu with adjustable over load setting and adjustable short circuit setting as per IS-13947 & IEC 60947-2 including all accessories like spreader terminals and Phase barriers including making all electrical connections by providing lugs of suitable size complete all as specified and directed by Engineer Incharge.Note: (i) MCCB and DB box shall be of same make. |
| 71 | M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 4.0 Sqmm size with multistranded copper conductor, FRLSH cable drawn in but including concealedconduit, including mediumm grade PVC conduit,heavy duty, ISI marked not less than 25 mm dia , with valid CML No,in any type of wall/floor, etc, with all connected fittings, including PVC insulated unsheathed 4.0 Sq mm FRLSH cable with multistranded copper conductor of green colour as continuous earth conductor cable connected to earth dolly and make good to match with the existing surfaces after completion complete all as specified and directed by Engineer Incharge.Note-(i) Two runs of 04 Sqmm cable with 01 run of 4 Sqmm earth wire along with PVC conduitshall be measured as one unit length. |
| 72 | M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 4.0 Sqmm size with multistranded copper conductor, FRLSH cable drawn in but including through surfaceconduit, including medium grade PVC conduit,heavy duty, ISI marked not less than 25 mm dia , with valid CML No. in any type of wall/floor, etc, with all connected fittings, including PVC insulated unsheathed 4.0 Sq mm FRLSH cable with multistranded copper conductor of green colour as continuous earth conductor cable connected to earth dolly and make good to match with the existing surfaces after completion complete all as specified and directed by Engineer Incharge.Note-(i) Two runs of 04 Sqmm cable with 01 run of 4 Sqmm earth wire along with PVC conduitshall be measured as one unit length. |
| 73 | M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm size with multistranded copper conductor, FRLSH cable drawn in but including through concealed conduit, including PVC medium grade conduit,heavy duty, ISI marked not less than 25 mm dia , with valid CML No. in any type of wall/floor, etc, with all connected fittings, including PVC insulated unsheathed 6.0 Sq mm FRLSH cable with multistranded copper conductor of green colour as continuous earth conductor cable connected to earth dolly and make good to match with the existing surfaces after completion complete all as specified and directed by Engineer Incharge.Note-(i) Two runs of 06 Sqmm cable with 01 run of 6 Sqmm earth wire along with PVC conduitshall be measured as one unit length. |
| 74 | S& FPVC insulated, PVC sheathed copper cable of size 1.5 sqmmx 3 core conforming to relevent IS,ISI mark complete all as specified and directed by Engineer Incharge.Note:- The cost of providing flexible PVC pipe for protection of flexible cable as per requirement is deemed to be included in quoted rate and nothing extra on this account is admissible. |
| 75 | S&F 240 V, Single pole and neutral enclosure with a two pin and earth plug and socket complete with one 20 amp single pole MCB C curve, 10 KA, including metal plug top (2P+E) complete all as specified and directed by Engineer Incharge. |
| 76 | M&L for fabrication of Glow Sign Board made up of white colour acrylic sheet albhabate letters with LED lights, each letter having600 mm height x 25 mm depth and- Total letters 15 Nos written as (TRISHAKTI MUSEUM) and NDA Logo - 02 Nos to be fixed on both ends and of same height as that of letters, all letters and NDA logo to be fixed onsuitable size rectangular shape ACP Sheet of Burgundry colour (NDA colour). ACP sheetto be fixed onsquare section hollow MS tube (of min size 25 mm) base frame duly painted with two coat of syenthtic enamel paint over one coat ofred oxide primer including nut, bolts, washer , stuts and all fixing arrangements to fix the board on Trishakti open museum bldg and making all electrical connection for LED light fittings, 1.0 sqmm x 3 core sheathedcopper cable from source to glow sign boardcomplete all as specified and directed by engineer in charge. Note : The contractor shall visit the office of AGE E/M (P) for the sample boardbefore quoting the rates. |
| 77 | S&F anti glare cob light18W LED light fitting adjustable spot/Focus light ( tilt angle upto 60 Deg ) recessed mounted in ceilings beams made of extruded Aluminium powder coating, High power high lumen LED, compact robust non corrosive aluminium body min 100 Im/W efficacy, 230 V, ACincluding all acessories as required and connection cable complete all as specified and directed by engineer in charge. Make:- Luker-Corvus Cob 60 Dog Model No-LAGCOB18N or techno commercial equivalent of make mentioned under appendix \"C\" to tender documents. |
| 78 | M&L for earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and incl GI wire 4 mm dia ,GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts - 03 Nos etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl RCC cover and , watering arrangement with GI pipe 20 mm diamedium grade and MS funnel, concrete pit including excavation and earth work in any type of strata and testing on completion etc complete all as specified and directed by engineer in charge.Note:- The GI earth wire and protection pipe beyond 7.5m will be measured and paid separately. |
| 79 | Supply, laying,testing and commissionnig of LT cables of size 35 Sqmm x 3.5 core, 1100 volt grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, conf to relevant IS,heavy duty including cable glands, cable lugs to suit the cable and for connecting cable in bus bar in LT panel with brass nut bolts double washers incl all material as required at site. Cables to belaid in trenches/ducts/under plinth floors passing through pipes etc or fixed on wallby providing GI clamps etc complete all as specified and directed by engineer in charge. |
| 80 | Supply, laying,testing and commissionnig of LT cables of size 6 x 2 core, 1100 volt grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, conf to relevant IS,heavy duty including cable glands, cable lugs to suit the cable and for connecting cable in bus bar in LT panel with brass nut bolts double washers incl all material as required at site. Cables to belaid in trenches/ducts/under plinth floors passing through pipes etc or fixed on wallby providing GI clamps etc complete all as specified and directed by engineer in charge. |
| 81 | Notefor item 71 & 72 : The contractor shall excavated the trench manually for laying of cable without damaging exisiting cables and water pipe line in route. The resposibility of repair in case of damages of existing cable or any type of water pipe line during excavation of trench is rest up on the contractor and nothing extra on this account is admissible and the repair work shall be carried out on same day by deploying skilled manpower. If the contractor fails to repair the damaged cable/pipe line panality of Rs 500/- per hour will be charged to contractor. |
| 82 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying of cable in underground etc. n exc 10 sq m on plan and n exc1.5 m in depth and getting out in any type of soil complete all as specified and directed by Engineer Incharge. |
| 83 | Returning, filling in, including spreading, levelling, watering and well ramming in layers by mechanical rammer with excavated soil complete all as specified and directed by Engineer Incharge. |
| 84 | Removing soil to a distance n.exc50m and depositing where directed at level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer Incharge. |
| 85 | M&L for cutting of road / hard standing/ path for laying of cables in underground through protection pipe of size of trench width 45 x depth 45 CM and making good with PCC (1:2:4) type B 1 using 20 mm graded stone aggregate complete all as specified and directed by Engineer Incharge. |
| 86 | Supply and laying of40mm outer dia, double walled corrugated DWC pipe conforming to IS- 16205 Part 24 with antirodent and non flame propogating properties of approved colour with fittings for cable protection complete all as specified and directed by Engineer Incharge. |
| 87 | M&L for laying 40 mm bore GI pipe, light grade, ISI marked, conf to relevant ISwith all fittings, in crossing road/path and in pole/wall up to junction box including necessary clamping etc. complete all as specified and as directed by Engineer-in-Charge. |
| 88 | S&F FRP junction box suitable for pole mounting and necessary connector for loop in loop out cable connection andsuitable size glands of size 250x 200x 100mm complete all as specified and directed by Engineer Incharge. |
| 89 | S&F LED Gate light (Post Top Lantern) outdoor type, IP 54, 18 Watt, Warm Whiteincluding fixing arrangements, gate light base and all acessoriesall as required at site complete all as specified and directed by Engineer Incharge.Make:- Luker Product code No- Zeus Post top LED LGL18 or techno commercial equivalent of make mentioned under appendix \"C\" to tender documents. |
| 90 | Supply of Customized CNC / Laser Cut Heavy duty LED Bollard specially designed with \"NDA\" word and \"NDA Logo\" as per Image . Bollard height 800 mm with MS Body with min 2.2 mm Thickness , Luminaire System Wattage should be 12 -15W , with PF > 0.95 CRI > = 70 andITHD % < 20at full load. Input Supply Voltage Range:150 -270 V, Frequency :50-60 HZ;Internal Surge Protection: 2.5 KV LED driver , Reverse Polarity, Open & Short Circuit . Luminaire CCT to be 2700K + 200 K. Product should be IP65. Luminaire base 150mmX150mm and height 800mm complete all as specified and directed by Engineer Incharge.Make:- Halonix or techno commercial equivalent of make mentioned under appendix \"C\" to tender documents. |
| 91 | Supply and installation weather, dust and vermin proof Feeder Pillar box (Cubical Panel box) factory made, outdoor type of 3.15 thickness of min size 450 x 400 x 300 mm, with luvors for ventilation , concial top,to accommodate MCCB 3/4 pole upto 100 Amps rating - 01 No (including MCCB63Amps, TPN, 415V, 50Hz 16 KA - 01 No), IP 54, front openable type, with locking arrangement, powder coated mounted on MS angle iron frame of size 40 x 40 x 6 mm welded in shape, painted with two coats of synthetic enamel paint over a coat of red oxide primer including necessary grouting in PCC 1:3:6 type C- 1 using 20 mm graded coarse stone aggregate complete with leg 45 cm grouted in PCC and 40 cm above ground including making all electrical connection with glands etc. complete all as specified and directed by Engineer Incharge.(For taking supply fromExisting LT Panel ) |
| 92 | M&L for Gl earth strip 25 x 4 mm as main earth lead on insulator or buried in ground/Wall/ ceiling etc, complete all as specified and directed by Engineer Incharge. |
| 93 | Supply Installation/fixing,testing and commissioning ofSplitAir conditioner unit of 2 TR capacity , energy efficient, inverter type (split type unit comprising of indoor and outdoor unit) electric driven (signal phase 230 Volt, 50 Hz) and with inbuilt air ionise, plasma filter (Anti MOLD pre filter and Electrostatic anit allergy enzyme filter, Micro partical catching filter & high density filter to eliminate PM 2.5 ) for better indoor air quality having latest model of AC with5 Star BEE rating,having ISEERvalue not less than 5.0 Wh, Split AC havingDC rotary compressor,have magnetic flux vector sine wave drive, vector wave eco invertor,copper tube condensor, Blue fin condensorwith dual barrier coating ( having hydrophobic and hydrphillic coating forbetter protection of condenser from corrosion) with R-32 refrigerant (non CFC gas),acoustic jaket on compressor,having Cooling operation range(21 to 52 degree celcius)out door ambient temperature , operationvoltage range (160 - 264 Volt) with protection for PCB , having long air flow ( indoor air delivery up to 12 mtrs, air volume on highest speed shall be min 777 CFM, having featur ofauto vane control up and down, right & left including necassary fixing arrangement complete (indoor unit at suitable place and hight inside the room and outdoor unit at suitable place outside the room) including metallicbrackets for mounting of indoor and MS powder coated `L` shapebracket for out door unitwith fixing bolts, insulatedcopper piping (liquid line of dia6.35 mm (1/4 inches) and gas line of dia 15.88mm (5/8) of suitable length from outdoor to indoor unit as per site requirement , electrical sheathed copper cable (power cable and control cable) ,cordless LED backlight with luminous button remote with display for operation. etc including all acessories as per OEM and as required at sitecomplete all as specified and directed by Engineer Incharge. |
| 94 | Notefor item No.84Above : (i) Air conditioner shall be initial filled/charged with refrigerant of specified quantity. (ii) Additional refrigerant pipes including filling of additional qty of refrigerant as required on site from outer unit to indoor unit beyond as supplied by manufacturersis deemeed to be included in AC unit rate.(iii) Suitable piping shall be provided of adequate length of size 5/8\" for draining of condensate water from indoor unit.(iv) Split type AC unit to supplied with cordless remote control for operation incl first fill of battery.(v) The condenser unit shall be copper tube with dual barrier coating ( having hydrophobic and hydrphillic coating) forbetter protection of condenser from corrosion(vi) The refrigerant to be used shall be R 32 (Non CFC compliance) as per latest technology.(vii) The spilt AC unit shall be latest model having valid 5 Star BEE rating as on date of installation. |
| 95 | Cont --- (viii)The contractor shall submit the brochure of AC with detail technical specification and take approval of GE before procurement.(ix) The contractor shall submit the Purchase voucher, Test certificate and warrranty certificate of AC. Contractor shallobtain the Warranty certificate from manufacture and to be submitted to department. (x) All the necessary accessories and T&P required on site for installation of indoor and out door unit shall be provided by contractor.(xi) Installation of AC to be done by manufacture authorised repesentative.(xii) The compresssor of unit shall be of min 8 yrs manufacture warranty and PCB having 5 yrs warranty. The contractor shall submit the warranty certificate to department.(xiii) Noise level (operation sound) of unit shall not be above 51 dB at SHi speed.(xiv) All civil work for core cutting /drilling the hole in any type of wall of any thickness on site for laying the refrigerant pipe line, and electrical cable from out door unit to indoor unitof AC and to make goodto match the surface as existing to be done by contractor with out any extra cost.(xv) Power supply electric cable to be provided with 15 Amp metal clad Pin topand to connect with source of supply by the contractorwithout any cost. (xvi) Ac electric DC compressor shall haveheat caulking method to minimizes cylinder distrotion .(xvii) The AC shall have horizontal, vertical , and auto vane control ( left & right , Up & Down) , auto fan speed mode, fast cooling mode, sleep mode, 24 hour on/ off programmable timer, auto restart, error code display on remote controller features. |
| 96 | Supply, install and testing 5 KVA wall mounted Voltage stabilizer for automatic operation, conf to IS 8448 Latest, single phase, naturally air cooled, indoor type & designed for input variation between 130 V to 280 V with output voltage stabilized at 220 with accuracy ± 1% and speed of correction 8 Volts per second, with LED display for digital voltmeter, having copper wound transformer, inbuit thermal overload protection, automatic high and low voltage cut off, time delay system,auto voltage regulator, surge protection complete all as specified and directed by Engineer Incharge. |
| 97 | S&F 20 mm bore CPVC pipes SDR 11including fittings , pipe to be fixed to walls / ceiling or laid in floors / trenches including GI shaddle/ clamp for fixing the pipe on wall on every 70 cm complete all as specified and directed. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy