}

Providing Additional Amenities Such As Approach Road, Compound Wall, Entrance Arch, And Bio Medical Waste Room To The Newly Constructed Building For 100 Bedded Critical Care Block In Government Hospital At Sholinganallurin Chennai District., sholinganallur-Tamil Nadu

Public Works Department has published Providing Additional Amenities Such As Approach Road, Compound Wall, Entrance Arch, And Bio Medical Waste Room To The Newly Constructed Building For 100 Bedded Critical Care Block In Government Hospital At Sholinganallurin Chennai District.. Submission Date for this Tender is 16-10-2025. Building Work Tenders in sholinganallur Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

51762209
Providing Additional Amenities Such As Approach Road, Compound Wall, Entrance Arch, And Bio Medical Waste Room To The Newly Constructed Building For 100 Bedded Critical Care Block In Government Hospital At Sholinganallurin Chennai District.
Tender
Indian
Tamil Nadu
Sholinganallur
16-10-2025

Tender Details

Providing additional amenities such as Approach road, Compound wall, Entrance Arch, and Bio Medical Waste room to the newly constructed Building for 100 Bedded Critical Care Block in Government Hospital at Sholinganallurin Chennai District. Earth Work Open Excavation By Manual Meansin All Soils And Sub-Soils And To Full Depth As May Be Directed Except In Rock Requiring Blasting Inclusive Of Shoring Shuttering, Bailing Out Water Wherever Necessary And Depositing The Excavated Earth With A Lead Of 10 Mts. Within The Compound In Places Shown By The Departmental Officers And Clearing And Levelling The Site, Etc., Complete Complying With Standard Specification And As Directedbythedepartmental Officers. , Earth Work Excavation For Foundationby Manual Means For Isolated, Combined And Other Type Foundationsin All Soils And Sub-Soils And To Full Depth As May Be Directed Except In Rock Requiring Blasting Inclusive Of Shoring Shuttering, Bailing Out Water Wherever Necessary And Depositing The Surplus Earth Within The Compound In Places Shown By Thedepartmental Officers With An Initial Lead Of 10 Mts And Initial Lift Of 2.00Mts. And Clearing And Levelling The Site, Etc., Complete Complying With Standard Specification And As Directedbythedepartmental Officers. , Installation Of Vertical Bored Cast In Situ Rcc Pilesin All Types Of Soils, Using Ready Mix Concrete Of M25 Grade, Withcement, Fine Aggregate, 20Mm And Down Graded Hbgs Jelly Coarse Aggregate. The Rate Includes Cost Of Reinforcing Steel, Binding Wire, Fabrication, Welding Charges, Placing Of Reinforcement Cage In Bore Hole In Correct Position, Cost Of Boring To The Required Depth With Bentonite Solution With Temprory Casing Of Required Length, Conveyance Of Rmc To Site And Pouring Concrete Using Tremine Pipes, Conveyance Of All Materials To The Site Including All Tools And Plants, Shifting The Plants And Equipments From One Point To Another, Excavation Of Mud Pits For Circulation Of Bentonite Solution, Closing The Mud Pits To Original Level And Mud Removal With Initial Lead And Lift But Including Dismandeling The Concrete Above The Cut Off Level Etc Complete As Directed By The Departmental Officers Including Socketing. The Reinforcement Cage Should Be Welded Properly For Lifting. The Concrete Cubes To Be Tested As Per Is 456-2000. Acceptance Criteria By Clause 16.1. Frequency Of Testing Should Be As Per Clause 15.2.2. The Length Of Pile For Payment Shall Be Measured Up To Natural Ground Level. The Work Should Be Carried Out As Per Is 2911. Pile Depth Should Be Decided By The Departmental Office At Site. , 300 Mm Dia Pile Having Longitudinal Main Reinforcement Of 6 Nos 12#With Helical Reinforcement At 8 # @ 150Mm C/C With Inner Rings Of 12 # @ 1000Mm C/C With Liftinghook Of12 # At Required Length. , Supplying And Filling In Foundation And Basement, Etc With Crushed Stone Sand (M-Sand) In Layers Of Not More Than 15 Cm Thick Well Watered, Rammed And Consolidated Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Supplying And Filling In Foundation, Basement, Etc With Quarry Rubbish In Layers Of Not More Than 15 Cm Thick Well Watered, Rammed And Consolidated Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers , Supplying And Filling Basement With Conveyed Earthof Earth With A Lead Of 5 Km From The Filling Should Be Made In Layers Of 15 Cm Thick Well Compacted.The Process Will Be Repeated For Another Layer Or Part There Of At The Specified Intervals As Per Specification And As Directed By The Departmental Officers Etc.,Complete. , Providing Pre Constructional Anti-Termite Treatment For The Construction Of Building Including Cost Of Chemicals Labour As Per Standard Specification. Labour For Preparing The Area For Treatment By Spreading Chemicals And Other Incidental Charges Complete. The Rate Shall Be Inclusive Of Giving Anti Termite Treatment To The Building For The Following Four Stages Including Breaking The Termite Moulds Making Holes With Crow Bars At An Interval Of 12 To A Depth Of 8 In The Periphery Of The Building Including Flooring Area And Pouring Chemicals Etc., Complete As Per Isi 6313/1981. , Cement Concrete 1:5:10 (One Cement, Five Sand And Ten Hard Broken Stone Jelly) Using 40 Mm Gauge Hard Broken Granite Stone Jelly For Foundationincluding Dewatering Wherever Necessary And Laid In Layers Of Not More Than 15 Cm Thick Well Rammed, Consolidated And Curing Etc. Complete Complying With Standard Specification , Supplying And Erecting Steel Centering Including Necessary Supports For Plane Surfaces For Reinforced Cement Concrete Works Such As Column Footings, Column Pedestals, Plinth Beams, Grade Beams, Staircase Steps, Etc. Which Require Only Nominal Strutting Using Mild Steel Sheets Of Size 90Cm X 60Cm And 10 Bg Stiffened With Welded Mild Steel Angles Of Size 25Mm X 25Mm X 3 Mm For Boarding, Laid Over Silver Oakjoists Of Size 10Cm X 6.5Cm Spaced At About 75Cm Centre To Centre Or At Suitable Intervals Etc. Complete In All Floors Complying With Standard Specifcation. (Payment For Centering Shall Be Given After The Concrete Is Laid) , Supplying And Erecting Centering For Plane Surfaces Such As Rcc Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks Etc.. With Necessary Supports And Strutting Upto 3.60M Height In All Floors With All Cross Bracings Using Ms Sheets Made Of 10 Gauge Thick Welded With Ms Angle Of Size 25Mm X 25Mm X 3Mm For Boarding Laid Over Steel Adjustable Span Of Size 2M X 2M(Expandable Upto 3.60M) And Silver Oak Joists Of Size 10 X 5 Cm Spaced At 50Cm To 60Cm C/C And Supported By Steel Adjustable Telescopic Props Of Size 2M X 2M (Expandable Upto 3.60M) Made With Outer Steel Pipe With Dia 50Mm (3.60Mm Thick) And Inner Steel Pipe With Dia 40Mm (2.90Mm Thick) Spaced At Not More Than 50 To 60Cm C/C , Etc Complete Complying With Standard Specifications. Steel Adjustable Span And Steel Adjustable Telescopic Props Shall Be Provided As Directed By The Departmental Officers. (Payment For Centering Shall Be Given After The Concrete Is Laid). , Supplying And Erecting Centering For Plane Surfaces Such As Rcc Floor Slab, Roof Slab, Loft, Landing Slabs, Etc With Necessary Supports And Strutting Upto 3.60M Height In All Floors With All Cross Bracings Using Ms Sheets Made Of 10 Gauge Thick Welded With Ms Angle Of Size 25Mm X 25Mm X 3Mm For Boarding Laid Over Steel Adjustable Span Of Size 2M X 2M (Expandable Upto 3.60M) And Supported By Steel Adjustable Telescopic Props Of Size 2M X 2M (Expandable Upto 3.60M) Made With Outer Steel Pipe With Dia 50Mm (3.60Mm Thick) And Inner Steel Pipe With Dia 40Mm (2.90Mm Thick) , Etc Complete Complying With Standard Specifications. Steel Adjustable Span And Steel Adjustable Telescopic Props Shall Be Provided As Directed By The Departmental Officers.(Payment For Centering Shall Be Given After The Concrete Is Laid). , Supplying And Erecting Steel Centering Including Necessary Supportsfor Plane Surfaces Such Asrectangular Or Square Rcc Columns Etc. Which Require Only Nominal Strutting Using Mild Steel Sheets Made Of 10 Gauge Thick Welded With Ms Angle Size 40Mm X 40Mm X 5 Mm And Supported By Steel Adjustable Telescopic Props Of Size 2M X 2M (Expandable Upto 3.60M) Made With Outer Steel Pipe With Dia 50Mm (3.60Mm Thick) And Inner Steel Pipe With Dia 40Mm (2.90Mm Thick).Etc..Complete In All Floors Complying With Standard Specifcation. Steel Adjustable Telescopic Props Shall Be Provided As Directed By The Departmental Officers. (Payment For Centering Shall Be Given After The Concrete Is Laid). , Supplying And Erecting Steel Centering Including Necessary Supports For Plane Surfaces For Reinforced Cement Concrete Works Such As Vertical Slab, Side Slabs Of Boxing, Vertical Drops, Facia, Vertical Wall, Etc. Using Mild Steel Sheets Of Size 1200Cm X 60Cm And 10 Bg Stiffened With Welded Mild Steel Angles Of Size 40Mm X 40Mm X 5 Mm For Boarding, Laid With Silver Oakjoists Of Size 10Cm X 5Cm& 7.5Cm X 5Cm As Support Runner, Top Horizontal Stiffener Spaced At About 60Cm To 90Cm Centre To Centreor At Suitable Intervals. Ms Channel Section (Ismc 100) Shall Be Provided As A Vertical Support @1.20M C/C And With Lateral Support Of Steel Adjustable Telescopic Props Of Size 2M X 2M (Expandable Upto 3.60M)& Steel Pipes Of 20Mm Dia @ Required Level/Spacing Etc. Complete Complying With Standard Specifcation And As Directed By The Departmental Officers. (Payment For Centering Shall Be Given After The Concrete Is Laid) , Providing And Laying In Position, Standardised Concrete Mix M-20 Grade In Accordance With Is 456 Using 20Mm And Down Graded Hard Broken Granite Stone Jelly For All Rcc Items Of Works With Minimum Cement Content Of 325 Kg/M3 And Maximum Water Cement Ratio Of 0.55, Including Admixture (Plasticiser / Super Plasticiser) In Recommended Proportions As Per Is:9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability With About (5 Cu.M.) 7730 Kg. Of 20Mm Machine Crushed Stone Jelly And With About (3.3 Cu.M.) 5156 Kg. Of 10-12Mm Machine Crushed Stone Jelly And With About (4.79 Cu.M) 7670 Kg. Of Crushed Stone Sand, But Excluding Cost Of Reinforcement Grill And Fabricating Charges, Centering And Shuttering And Also Including Laying, Vibrating With Mechanical Vibrators, Finishing, Curing, Etc. And Providing Fixtures Like Fan Clamps In The Rcc Floor/ Roof Slabs Wherever Necessary Without Claiming Extra, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. The Coarse And Fine Aggregates To Be Used Should Comply With The Requirements Of Is Standards. (No Separate Payment Will Be Made By The Department For The Excess Usage Of Materials). , Foundation Basement , Ground Floor , Providing And Laying In Position, Standardised Concrete Mix M-25 Grade In Accordance With Is:456-2000 Using 20Mm And Down Graded Hard Broken Granite Stone Jelly For All Rcc Items Of Works With Minimum Cementcontent Of 400 Kg/M3 And Maximum Water Cement Ratio Of 0.45, Including Admixture (Plasticiser / Superplasticiser) In Recommended Proportions As Per Is:9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability With About (5.0 Cu.M.) 7730 Kg. Of 20Mm Machine Crushed Stone Jelly And With About (3.3 Cu.M.) 5156 Kg. Of 10-12Mm Machine Crushed Stone Jelly And With About (4.79 Cu.M) 7670 Kg. Of Crushed Stone Sand, But Excluding Cost Of Reinforcement Grill And Fabricating Charges, Centering And Shuttering And Also Including Laying, Vibrating With Mechanical Vibrators, Finishing, Curing, Etc. And Providing Fixtures Like Fan Clamps In The Rcc Floor/ Roof Slabs Wherever Necessary Without Claiming Extra, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. The Coarse And Fine Aggregates To Be Used Should Comply With The Requirements Of Is Standards. (No Separate Payment Will Be Made By The Department For The Excess Usage Of Materials). , Foundation Basement , Ground Floor , Providing And Laying In Position, Standardised Concrete Mix M-30 Grade In Accordance With Is:456-2000 Using 20Mm And Down Graded Hard Broken Granite Stone Jelly For All Rcc Items Of Works With Minimum Cementcontent Of 400 Kg/M3 And Maximum Water Cement Ratio Of 0.45, Including Admixture (Plasticiser / Superplasticiser) In Recommended Proportions As Per Is:9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability With About (5.0 Cu.M.) 7730 Kg. Of 20Mm Machine Crushed Stone Jelly And With About (3.3 Cu.M.) 5156 Kg. Of 10-12Mm Machine Crushed Stone Jelly And With About (4.79 Cu.M) 7670 Kg. Of Crushed Stone Sand, But Excluding Cost Of Reinforcement Grill And Fabricating Charges, Centering And Shuttering And Also Including Laying, Vibrating With Mechanical Vibrators, Finishing, Curing, Etc. And Providing Fixtures Like Fan Clamps In The Rcc Floor/ Roof Slabs Wherever Necessary Without Claiming Extra, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. The Coarse And Fine Aggregates To Be Used Should Comply With The Requirements Of Is Standards. (No Separate Payment Will Be Made By The Department For The Excess Usage Of Materials). , Foundation Basement , Supplying, Fabricating And Placing In Position Mild Steel / Ribbed Tor Steel Grills For All Rcc Works As Per Design Given Including Cost Of Steel And G.I. Binding Wire In All Floors Etc. Complete Complying With Standard Specification.(Contractor Has To Make His Own Arrangements For The Supply Of Steel And Binding Wire) , Brick Work In Cement Mortar 1:5 (One Cement : Six Sand) Using Best Quality Fly Ash Bricks 230 X 110 X 70Mm For Superstructure Including Curing, Etc., Complete Complying With Standard Specifiction.Foundation & Basement , Brick Work In Following Cement Mortar 1:6 Using Fly Ash Bricks Of 230 X 110 X 70Mm Size Conforming To Is:12894-1989 Class Designation Not Less 50 Kg./ Sq.Cm. Average Compressive Strength In Cement Mortar 1:6 For Load Bearing Structures For Foundation And Basement And For Superstructure Including Curing, Etc., Complete Complying With Standard Specifiction. , Ground Floor , First Floor , Paving The Floor With Best Quality Vertified Tiles Of Size 600 X 600 X 8Mmof Approved Colour, Shade And Quality Laid In Cement Mortar 1:3 (One Cement And Three Crushed Stone Sand) 20Mm Thick In All Floors And The Top Pointed With The White Cement Mixed Same Colour Pigments Etc., Complete Complying With Standard Specification.(The Make And Brand Of The Tiles Should Be Got Approved By Executive Engineer Before Use On Works) , Dadooing With Granite Tiles Of Synthetic Grey, Paradise, Andsimilar Varieties Of Suitable Sizes In Cement Mortar 1:2 (One Cement And Two Crushed Stone Sand) 10Mm Thick And Pointing The Joints With White Cement Mixed With Colouring Pigments At The Rate Of 0.40 Kg. / Sq.M. Neatly In All Floors, Curing, Etc., Complying With Standard Specification And As Directed By The Departmental Officers. , Supplying And Fixing Upvc (Un-Plasticized Polyvinyl Chloride) Windows Of Casement Type (Open) From The Profile The Size Of Outer Frame 60Mm X 58Mm And Shutter Profile Are Reinforcement With Gi/1Mm 125Gsm And 100% Corrosion Free, The Profiles Are Multi Chambered Sections With Wall Thick Of 2Mm. The Epdm Rubber (Black Colour) Covered With Over All The Edges Of Frame And Shutter The Shutter Will Be Provided With Espag Multi Power Point Locks And Also It Operates As Handle.The Corners And Joints Should Be Welded And Cleaned.Radiations Free Pin Headed Plain Or Brown Colour Glass 4Mm Thick Should Be Provided To The Shutter And It Should Not Allow Leakage Of Water Even At Most Ranging Storms And Should Have Key Lockable Action, Security Protective Hinges, Strong Lockingsystems And As Per Size For Arresting Noise And Energy Loss.The Connecting Mechanism Between Sash And Outer Frame That Enables Opening Of The Window.The Window Should Be Fixed To The Wall With 100% Packing With Screws And Silicon Packing All Round The Frames.The Window Should Be Got Approved From The Executive Engineer Before Use On Work , Supplying And Fixing Upvc (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators Of From The Profilethe Size Of Outer Frame 60Mm X 58Mm And Shutter Profile Size Of 60 X 78Mm Both Profiles Arereinforcedwith Gi/1Mm 125Gsm And 100% Corrosion Free, The Profile Are Multi Chambered Sections With Wall Thick Of2mm.The Epdm Rubber (Black Colour) Covered With All Over The Edges Of Frame And Shutter.The Corners And Joints Should Be Welded And Cleaned.Radiations Pin Headed Glass 4Mm Thick Should Be Provided In The Louvers.The Window Should Be Fixed To The Wall With 100% Packing With Screws And Silicon Packing All Round The Frames. The Ventilator Should Be Got Approved From The Executive Engineer Before Use On Work , Supplying And Fixing M.S. Grills For Doors, Windows And Ventilators Of Approved Design And As Directed By The Departmental Officers Including Cost Of Ms Grills Labour Charges And Cost Of One Of Red Oxide Primer Coat Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Paving The Top Of Roof With Solar Refelective Ceramic Tiles Of Size 305 X 305 X 7Mm Thick Of Approved Quality And Colour Laid In Cement Mortar 1:3 (One Cement And Three Crushed Stone Sand) 12Mm Thick And Pointed With Tile Grout (Nitotile Grout Or Equivalent) And Cement In The Ratio Of 1:3 For Joint, Curing Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers.(The Make And Brand Of The Tiles Should Be Got Approved By The Executive Engineer Before Use On Works) , Supplying And Fixing In Position Best Approved Of Bis Quality Pvc Rain Water Down Fall Pipes Having A Pressure Of 6 Kg. / Sq.Cm Including Cost Of Necessry Pvc Shoe, Pvc Bend, Cost Iron Gratings Of Required Diameter And Special Clamps, Brass Screws, Nails, Etc., And Fixing Of Cast Iron Gratings At Junction Of Parapet And The Rcc Roof Slab Including Finishing Neatly Etc., Complete. The Rate Shall Be Inclusive Of Cost Of Removable Cast Iron Grating. The Pvc Pipe Shall Be Fixed In Wall With Special Type Of U Clamp At The Centre Of The Pipe Line In Addition To Those For More Than 3.0 Metre Pipe Length, Etc., Complete Complying With Standard Specification. , 160Mm Dia , Plain Cement Concrete 1:2:4 (One Cement, Two Crushed Stone Sand And Four Hard Broken Stone Jelly) Using 6Mm To 12 Mm Jelly For Wearing Coat Includinglaying, Compacting, Finishing And Curing, Etc., Complete As Per Standard Specificatins And As Directed By The Departmental Officers.- Mixing By Manual Means , Plastering With Cement Mortar 1:5 (One Cement And Five Plastering Sand), 12Mm Thick In All Floors Including Mortar Plasticizer At 200Ml Per 50Kg Of Cement Used, Curing Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Plastering With Cement Mortar 1:3 (One Cement And Three Plastering Sand) 12Mm Thick Mixed With Water Proofing Compound Conforming To Bis At 2% By Weight Of Cement Used Including Finsihing, Curing, Etc., Complete In All Floors Complying With Standard Specification And As Directed By The Departmental Officers. , Supplying And Applyingof Two Coats Of Putty3mm Thick Over The Exposed Rcc Surface Of Ceiling Including Finishing The Joints Smoothy With Grinding Machine And The Surface Shall Be Througly Cleaned Out Of Dust And Scrubbing The Surface Shall Than Be Allowed To Dry For Atleast 48 Hours. It Shall Be Than Sand Papered (Waterpoof Abrasive Sheet) To Give A Smooth And Even Surface. Any Uneveness Shall Be Made Good By Applying 1 St Coat Of Putty Mixed Withwater On The Entire Surface Including Filling Up The Undulations And Applying2 Nd Coat Of Putty After 6 Hours Of 1 St Coat Of Putty And Then Sand Papering ( Waterpoof Abrasive Sheet) The Same After Its Dry And Finishing Thesurface Smoothy Etc.,Complete Complying With Standard Specifiction And As Directed By The Departmental Officers.(The Rate Inclusive Of Hire Chargesfor Grinding Machine With Wheel,Cost Of Sand Paper(Waterpoof Abrasive Sheet) Cost Of Putty Blade,Labour Charges For Grinding The Joints And Sand Papering,Two Coats Putty,Scrapping The Putty Area To Level The Surface Smooth Etc., Complete). The Putty Should Be Got Approved By The Execuctive Engineer Before Use On Work. , Painting Two Coats Of Newly Plastered Wall Surface With Ready Mixed Plastic Interior Emulsion Paint Of First Class Quality And Of Approved Colour Over A Priming Coat Including Thorough Scrapping, Clean Removal Of Dirt, And Including Necessary Plaster Of Paris Putty, Wherever Required Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Painting Two Coats Of Newly Plastered Wall Surface With Ready Mixed Plastic Exterior Emulsion Paint Of First Class Quality And Of Approved Colour Over A Priming Coat Including Thorough Scrapping, Clean Removal Of Dirt, And Including Necessary Plaster Of Paris Putty, Wherever Required Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Textured Wall Painting With Exterior Weather Proof Emulsion Paint (2 Coats) Of Approved Quality And Colour Over A Priming Coat Including Through Scrapping, Clean Removal Of Dirt Etc., Complete And Including Necessary Plaster Of Paris, Putty Whereas Required As Directed By The Departmental Officers. , Supplying , Fixing And Roofing With Colour Galvalume Sheet Of 0.47Mm Thickwith All Necessary Accessories Such As J/V Bolt And Nuts Of Suitable Length With Suitable Bitumen Washers Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Supplying And Fixing Zinc Sheet Roof Usingsquare Tube And Tied With Welding The Rate Including The Cost Of Materials,Scafolding Charges,One Coat Of Primer And Two Coat Synthetic Enamel Anticorrosivepaint Etc.,Complete And Complying With Standard Specification. , 75X75x4mm Square Tube , 50X50x4mm Square Tube , 40X40x3.20Mm Square Tube , Painting New Iron Works Such As Steel Doors, Windows, Ventilators, Window Bars, Balustrades Etc., With Two Coats Of Best Approved First Quality And Colour Of Synthetic Enamel Paint Over One Coat Of Priming Coat Using Zinc Chromite Primer In All Floors Including Cost Of Priming Coat Etc., Complete Complying With Standard Specification. (The Make, Quality And Colour Of Paint Should Be Got Approved By The Executive Engineer Before Use On Works.) , Casting, Supplying And Fixing Of Die Cast Brass Letterswith Thickness Of 20Mm Hollow Type In English / Tamilof Following Sizes. The Die Cast Letters Should Be Finished Neatly And Provided With Powder Coating Finish Of Approved Colour Etc., As Directed By The Departmental Officers. The Rate Includes The Cost Of All Materials, Casting, Transportation And Fixing In Position Etc.,Complete As Per The Standard Specification. , Tamil Brass Letters , Emblem (15”) , Paving The Floor With Pre-Polished Concrete Anti-Skid Tiles (Required Shape And Design) Of 20Mm Thick Of Approved Quality And Colour Laid In Cement Mortar 1:3 (One Cement And Three Sand) 20Mm Thick And Pointed With White Cement Mixed With Colouring Pigment At The Rate Of 0.40 Kg. / Sq.M., Curing, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers.(The Make And Brand Of The Tiles Should Be Got Approved By Executive Engineer Before Use On Works). , Manufacturing, Supplying And Fixing Of Stainless Steel Hand Rails For Staircase Using 50Mm Dia 304L Grade Stainless Steel Pipe Of 1.60Mm Thick At Required Locations To A Hseventh Of 900Mm From Finished Floor Level Welded To 38Mm Dia Stainless Steel Pipe Post Of 1.00Mm Thick As Vertical At 900Mm Centre With 2 Nos. Of 25Mm Dia Intermediate Horizontal Stainless Steel Pipe Of 1.60Mm Thick In Between.The Vertical Pipe Has To Be Welded To The 100 X 100 X 6Mm Ms Base Plate Encased In The Base Concrete.The Rate Is Inclusive Of The Charges For Cutting, Bending, Welding, Grinding, Polishing, Conveyance, Electrical Charges, Etc. Complete , Supplying And Erecting Pull And Push Type Rolling Shutter With Isi Make Of Approved Size And Section Using 18 Gi Sheet.The Shutter Shall Be Painted With One Coat Of Red Oxide Primer And The Rate Is Inclusive Of Hood Covers, Transportation Charges Et , Supplying And Fixing In Position Salem Stainless Steel Door Frames 105 X 60Mm With 35Mm Single Rebate With 1.60Mm Thick Sheet Frames Including Bottom Tie, Hod Fast And Provision To Fix Aldrops, Tower Bolt, Hinges And Lock Strike Plates Confirming To Is 4231 - 1976 Including Filling The Rear Hollow Portion With Pcc 1:2:4Using One Cement, Three Sand And Six Aggregate Using 12Mm Gauge Hard Broken Granite Stone Jelly Including Cost Of Dismantling The Masonry And Concrete Wherever Necessary And Redoing The Same To To The Original Condition After Fixing Including The Scafolding Charges And Labour Charges For Fixing Furniture Fittings Etc., But Including Cost Of Furniture Fitting With Standard Specification. , Supplying And Fixing Solid Core Particle Board Flush Shutter Of Nominal Thick Of 35 Mm With Necessary T.W. Internal Lipping Conforming To Is 2302 With Teak Ply On One Side And Commercial Ply On Other Side With Teak Wook Lipping Alround35 Mm Thick Including Supplying And Fixing Cost Of Wind Appliances And Furniture Fittings Such As 1No .200X12mm Aluminium Tower Bolt 2Nos. 150X12mm Aluminium Tower Bolts 1No. 250X16mm Aluminium Aldrops, 3 Nos. 200Mm ‘D’ Type Aluminium Door Handle And Door Stopper With Bush Etc., Complete As Directed By The Departmental Officers. , Double Leaf , Supplying And Fixing 300Mm Dia Rcc Hume Pipe Including Labour Charges Etc., Complete , Provinding Laying For Expansion Joint For Road Cutting Every 3 M Interval With Using Bitumen Etc., Complete , Vaccum Dewatering For Approach Road Flooring Etc., , Providing Expansion Joint Of 12.5Mm Wide In Between Rcc Twin Columns From Top Of Pedastal To Full Height Including Filling The Inner Space With Suitable Non-Absorbent, Flexible And Well Compressible Filler Materials Of Approved Quality And Brand; Finishing The Sides Of Rcc Columns With Polysulphide Sealents For A Depth Of 7.5Mm On Either Side Covering The Inner Space Filled With Filler Materials As Above Etc., Complete Complying With Standard Specifications And As Directed By The Departmental Officers. , Providing And Laying Of Granular Sub-Base By Providing Close Graded Material, Mixing In A Mechanical Mix Plant At Omc, Carriage Of Mixed Material To Work Site, Spreading In Uniform Layers With Motor Grader On Prepared Surface And Compacting With Vibratory Power Roller To Achieve The Desired Density, Complete As Per Clause 401 , Providing And Laying, Spreading And Compacting Graded Stone Aggregates To Wet Mix Macadam 250Mm Thick Specification Including Premixing The Materials With Water At Omc In Mechnanical Mix Plant Carriage Of Mixed Material By Tipper To Site Laying In Uniform Layers With Pavers In Sub Base/Base Course On Well Prepared Surface And Compacting With Vibratory Roller To Acheive The Desired Density Including Cost Of Material, Labour Charges, Rentals For Machinery, Fuel And All Other Incidental Charges Etc., Complete As Per Clause 406 Of Morth Rev-5 , Gst At 18%

Key Value

Document Fees
Refer document
EMD
INR 335800.0 /-
Tender Value
INR 6.51 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail