| 1 | Annual Plan-AREEKODE GP-IMPROVEMENTS TO VETINARY DISPENSARY BUILDING |
| 2 | 10.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 3 | 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 4 | OD256390/2025-2026:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coated thickness withzinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxyprimer on both side of the sheet and polyester top coat 15-18 microns. Sheet should haveprotective guard film of 25 microns minimum to avoid scratches during transportation andshould be supplied in single length up to 12 meter or as desired by Engineer-in-charge. Thesheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal,complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins,rafters and trusses and including cutting to size and shape wherever required.Details of cost for 216.14 sqm (External dimension of plinth)Area of roof 20.2x10.70m=216.14sqmSheets Used = 20Nos x 10.70m x 1.06m = 226.84 sqmadd 3% wastage = 6.81 Total = 233.65sqm |
| 5 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 6 | 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 7 | 13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). |
| 8 | OD256603/2025-2026:Providing and fixing 200 mm wide, square cut PVC 4kgf/cm2 rain water gutter pipe with ironbrackets with 25x5 mm size flat, screws and washers etc., including making necessaryProviding and fixing 200 mm wide, square cut PVC 4kgf/cm2 rain water gutter pipe with ironbrackets with 25x5 mm size flat, screws and washers etc., including makingnecessaryconnections with rain water pipes etc. complete. |
| 9 | 50.18.7.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall |
| 10 | OD256819/2025-2026:Engaging coolie for cleaning premises |