| 1 | 1). Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 2 | a). Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 3 | 2). Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 4 | 3). Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 5 | 4). Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 6 | a). 250x16 mm |
| 7 | 5). Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 8 | a). 250x10 mm |
| 9 | 6). Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 10 | a). In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete. |
| 11 | 7). Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. a). Double charge vitrified tile polished finish of size |
| 12 | i). Size of Tile 600 x 600 mm |
| 13 | 8). Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3kg/sqm |
| 14 | 9). Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. |
| 15 | 10). 12 mm cement plaster of mix : |
| 16 | a). 1:6 (1 cement: 6 fine sand) |
| 17 | 11). 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 18 | a). 1:6 (1 cement: 6 fine sand) |
| 19 | 12). Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 20 | a). New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 21 | 13). Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 22 | a). Two coats. |
| 23 | 14). Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 24 | 15). Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. |
| 25 | a). With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. |
| 26 | 16). Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 27 | 17). Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 28 | a). Of area 3 sq. metres and below |
| 29 | 18). Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 30 | 19). Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 31 | a). For fixed portioni). Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 32 | b). For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). i). Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 33 | 20). Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 34 | a). Pre-laminated particle board with decorative lamination on both sides. |
| 35 | 21). Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 36 | a). With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) |
| 37 | b). With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 38 | 22). Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 39 | a). Upto 5mm depth and 5 mm width |
| 40 | 23). Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 41 | 24). Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in-charge |
| 42 | a). Polyester powder coated minimum thickness 50 micron aluminium. |
| 43 | 25). Dismantling of hard board/gypsum partition/ wall panelling of any type with framework of any typeincluding dismembering, stacking and placing all the serviceable material at the designated locationat site of work and disposal off unserviceable materialall complete as directed by the Engineer-in-charge. (Area of hard board/gypsum partition/ wall panelling being dismantledshall be measured for payment) |