| Sl. No. | Item Description |
| 1 | Civil Work |
| 2 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. |
| 3 | Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete. |
| 4 | Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials,stacking the same as and where directed in the compound including scaffolding etc. complete. |
| 5 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete. |
| 6 | Dismantling the R.C.C. work 1:2:4 and sorting out the materials such as steel etc. as directedandstackingthemwithinthe specified lead as directed. |
| 7 | Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. |
| 8 | Dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts etc. complete. |
| 9 | Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc complete. |
| 10 | Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed concrete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete. |
| 11 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring andstrutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 12 | Excavation for foundation in Hard murumand boulders including removingthe excavatedmaterial upto a distance of 50 metres, beyondthe building area andstacking andspreadingasdirected, dewatering, preparing the bed for the foundation and necessarybackfilling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) By Mechanical Means |
| 13 | Excavation for foundation in Hard murumand boulders including removingthe excavatedmaterial upto a distance of 50 metres, beyondthe building area andstacking andspreadingasdirected, dewatering, preparing the bed for the foundation and necessarybackfilling, ramming, watering including shoring and strutting etc. complete. (Lift from 3.0 m to 4.50 m.) By Mechanical Means |
| 14 | Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. (a)For 2 Km. |
| 15 | Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. (e)For 5 Km. |
| 16 | a) Filling in plinth and floors with contractors approved material /murum in 15 cmto 20 cm layers including watering and compaction complete. |
| 17 | Providing soling using 80 mm size granite / quartzite / gneiss / trap metal in 15 cm. layer including hand packing filling voids with sand / grit, ramming, watering etc. complete. |
| 18 | Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) |
| 19 | Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) Ground Floor |
| 20 | First Floor |
| 21 | Second Floor |
| 22 | Third Floor |
| 23 | Fourth Floor |
| 24 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand |
| 25 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including centering, formwork,cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand. Ground Floor |
| 26 | First Floor |
| 27 | Second Floor |
| 28 | Third Floor |
| 29 | Fourth Floor |
| 30 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionandroughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fullyautomatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc).Ground Floor |
| 31 | First Floor |
| 32 | Second Floor |
| 33 | Third Floor |
| 34 | Fourth Floor |
| 35 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand /Crushed sand VSI Grade finely washed etc) |
| 36 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landingsas per detailed designs and drawings including centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand Ground Floor |
| 37 | First Floor |
| 38 | Second Floor |
| 39 | Third Floor |
| 40 | Fourth Floor |
| 41 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, formwork, steel props, laying/pumping,compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.)with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Ground Floor |
| 42 | First Floor |
| 43 | Second Floor |
| 44 | Third Floor |
| 45 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks,laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc).Ground Floor |
| 46 | First Floor |
| 47 | Second Floor |
| 48 | Third Floor |
| 49 | ProvidingandlayingCastinsitu/ReadyMixC.C.M-25oftrapmetalforRCC rectangulargridbeamwithslabasperdetaileddesignanddrawingorasdirected includingdewateringifnecessary,steelcentering,formwork,coverblocks, laying/pumping,compacting,finishingtheformsurfacewithC.M.1:3ofsufficient minimumthicknesstogivesmoothandevensurfaceor roughening them if special finish is to be provided and curing complete (Excludingreinforcement and structural steel). with fully automatic micro processor based PLC withSCADA enabled reversibleDrumTypemixer/ concreteBatch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Fourth Floor |
| 50 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. FOR TMT / HYSD STEEL BARSGround Floor |
| 51 | First Floor |
| 52 | Second Floor |
| 53 | Third Floor |
| 54 | Fourth Floor |
| 55 | Providing fly ash brick masonry with conventional / I.S. type fly ash bricksin C.M. 1:6 in foundation and plinth includingbailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.Ground Floor |
| 56 | Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. complete.Ground Floor |
| 57 | First Floor |
| 58 | Second Floor |
| 59 | Third Floor |
| 60 | Fourth Floor |
| 61 | Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc.complete.Ground Floor |
| 62 | First Floor |
| 63 | Second Floor |
| 64 | Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1kg/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kg/bag of cement groutingand finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years\" guarantee on requisite stamp paper including curing etc.complete.Ground Floor |
| 65 | First Floor |
| 66 | Second Floor |
| 67 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coatof cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm.thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mouldat the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.Second Floor |
| 68 | Third Floor |
| 69 | Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete ) Ground Floor |
| 70 | Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.Ground Floor |
| 71 | First Floor |
| 72 | Second Floor |
| 73 | Third Floor |
| 74 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.Ground Floor |
| 75 | First Floor |
| 76 | Second Floor |
| 77 | Third Floor |
| 78 | Fourth Floor |
| 79 | Providing internal cement plaster 20mm thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete.Ground Floor |
| 80 | First Floor |
| 81 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positionsincludingbasecoatof15 mmthickin cementmortar1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 daysandkeepingthe surface of the base coat rough to receive the sand faced treatment6to8mm thickin cementmortar1:4finishingthesurfacebytakingout grainsandcuringforfourteendays scaffolding etc.complete.Ground Floor |
| 82 | First Floor |
| 83 | Second Floor |
| 84 | Third Floor |
| 85 | Fourth Floor |
| 86 | Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all positionincluding preparing the surface, scaffolding etc. complete.Ground Floor |
| 87 | First Floor |
| 88 | Second Floor |
| 89 | Third Floor |
| 90 | Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffoldingif necessary preparing surface by thoroughly cleaning oil,grease,dirt and other materials as required, etc. complete.Ground Floor |
| 91 | First Floor |
| 92 | Second Floor |
| 93 | Third Floor |
| 94 | Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete.Ground Floor |
| 95 | First Floor |
| 96 | Second Floor |
| 97 | Third Floor |
| 98 | Fourth Floor |
| 99 | Providing cement patta / band of 2.50 cm width on either side of edges of plaster for doors and windows including scaffolding ,finishing, curing etc. complete.50mm |
| 100 | Providing cement patta / band of 2.50 cm width on either side of edges of plaster for doors and windows including scaffolding ,finishing, curing etc. complete.100mm |
| 101 | Providing cement patta / band of 2.50 cm width on either side of edges of plaster for doors and windows including scaffolding ,finishing, curing etc. complete.150mm |
| 102 | Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete..Ground Floor |
| 103 | First Floor |
| 104 | Second Floor |
| 105 | Third Floor |
| 106 | Fourth Floor |
| 107 | Providing andapplying one coatofsealcementprimerofapprovedmanufacture and shed includingscaffoldingpreparingthesurfacebycleaningdirtandotherforeign matters, scrapping if necessary including scaffolding etc. complete.Ground Floor |
| 108 | First Floor |
| 109 | Second Floor |
| 110 | Third Floor |
| 111 | Fourth Floor |
| 112 | Providing and applying plastic emulsion paint of approved quality, colour and shade tonew surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete..Ground Floor |
| 113 | First Floor |
| 114 | Second Floor |
| 115 | Third Floor |
| 116 | Fourth Floor |
| 117 | Providing and applying two coats Apex Ultima Puranature Anti- Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx,formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Ground Floor |
| 118 | First Floor |
| 119 | Second Floor |
| 120 | Third Floor |
| 121 | Fourth Floor |
| 122 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete..Ground Floor |
| 123 | First Floor |
| 124 | Second Floor |
| 125 | Third Floor |
| 126 | Fourth Floor |
| 127 | Providing and laying telephone black /Amba White /Cadbury brown /Rubyred /Ocean Brown granite stone of 18 to 20 mm thick for door frame /dado /window boxing etc. On C.M. 1:6 including filling joints with polymer base filler Numbering /moulding the sharp edges wherever necessary, curing, etc. complete.Ground Floor |
| 128 | First Floor |
| 129 | Second Floor |
| 130 | Third Floor |
| 131 | Providing and fixing machine cut mirror polished18mm to 20mm thick telephone black granite/AmbaWhite/Catbarybrown/RBIred/Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polishGround Floor |
| 132 | First Floor |
| 133 | Second Floor |
| 134 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red /Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.Ground Floor |
| 135 | First Floor |
| 136 | Second Floor |
| 137 | Third Floor |
| 138 | Providing and laying vitrified stone effect finish tiles having size 590 to 605 mm x 590 to 605 mm of 8 to 10 mm thickness and confirmingto IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc.complete. Ground Floor |
| 139 | Providing and laying vitrified stone effect finish tiles having size 590 to 605mm x 590 to 605mm of 8 to10mm thickness and confirming to IS.15622-2006 (Group Bla) of approved make,shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curign and cleaning etc. complete.Ground Floor |
| 140 | Providing and laying vitrified matt fininsh tileshaving size 590 mm to 605 mm x to 605 mmof 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approvedmake, shadeandpatternforflooringinrequiredpositionlaidonabed of1:4cementmorar including neat cement float, filling joints, curing and cleaning etc. complete.Ground Floor |
| 141 | First Floor |
| 142 | Second Floor |
| 143 | Third Floor |
| 144 | Providing and laying vitrified matt finish tileshaving size 590 mm to 605 mm x to 605 mmof 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approvedmake, shadeandpatternfordadoandskirtinginrequiredpositionfixed in1:4cementmortar including neat cement float, filling joints, curing and cleaning etc. complete.Ground Floor |
| 145 | First Floor |
| 146 | Second Floor |
| 147 | Third Floor |
| 148 | Providing and laying Antiskid Ceramic tiles of approved qualityof size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.Ground Floor |
| 149 | First Floor |
| 150 | Third Floor |
| 151 | Fourth Floor |
| 152 | Providing and laying polished hand cut Kotah Stone flooring 25mm to 30mm thick and 45cm to 55cm wide in plain/diamond pattern on a bed of 1:6 C.M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning complete.Ground Floor |
| 153 | Providing and fixing factory made Hydraulically pressed Mechanically vibrated and compacted precast inter locking cement concrete paving blocks 80MM thick in M-40 grade of approved size and shape for City streets, small /medium market roads,low volume roads, utility cuts on arterial roads etc. as specified and as per IS 15658:2006 including cost of all materials, manufacturing, curing, transportation of blocks to work site including loading, unloading and stacking as directed, laying paving blocks in position over prepared bed of natural sand / crushed sand of 50 mm thickness including necessary excavation in all stratas,spreading blindge of fine sand over the prepared bed, compacting blocks by plate vibrator etc. complete. |
| 154 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards,screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws.The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels.Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.Ground Floor |
| 155 | First Floor |
| 156 | Second Floor |
| 157 | Third Floor |
| 158 | Fourth Floor |
| 159 | METAL BAFFLE CEILING : Providing & fixing of horizontal level suspended ceiling comprisingofVerticalLinearBaffleCeilingmadeoutofAluminumExtrusionin Aluminum alloy grade 6063 T5. The baffle blade shall be in size of 100x25x3600mm in powder coated to Woodgrain/Plain finish (Red Oak, Cherry, Black & White).. The baffle shall be electrostatically polyester powder coated to a coating thickness of 60-80 micron. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –ATestfor1000hoursasperASTMG-154–(Cycle–1)andHumiditytestfor 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation within a manufacturing batch shall be delta E<1 using Excite/BYKGardnerinstrumentandglosslevel25±5at60˚asperASTMD523(Not applicable of Wood Grain Shade). The baffle blade shall be suspended using Slotted U- profileof20x30x3700mm(Thk-1.5mm)havingslotsinmoduleof25mmtokeep bafflesatanon-centerspacinginmultiplesof25mm.LongerlengthsofBaffletobe connected by Baffle Joiner and the ends to be fixed with End caps..SUSPENSION: Shall behangedusingbafflehangerfrom U-profilemade ofmildsteelwithpowdercoating thickness of 60-80 micron. The U – profile to comprise of alternate square & rectangular slots of 6.5x6.5mm & 28x6.5mm respectively on the web for locking the baffle hanger usingpluginclipto securethe hangerinperfectpositionandachieve uniform spacing between baffles. The overall dimension of the U – profile is 20(W) x 30(H) x 3750(L) mm and is rolled form from 1.5mm thick mild steel with a powder coating thickness of 60- 80micron.U-ProfiletobeconnectedtoeachotherusingU–ProfileSplice.TheU- profile shall be hanged from the true ceiling using threaded rod using a U- Profile hanger. TheBafflealongwithsuspensionsystem usedtogethershallcarrya10yearwarranty against manufacturing defect and manufacturer shall provide a warranty certificate. The supply shall be backed by a Manufacturing Test Certificate. INSTALLATION:Installation of U-Grid:The U profile to be suspended at every 1200mm center to center using 6mm threaded rod from the structural soffit using U-profile hanger. U-profile splice to be used to join more than one U profiles of length 3.7M. 1st U-Grid Channel must be no more than 400mm Ground Floor |
| 160 | First Floor |
| 161 | Second Floor |
| 162 | Third Floor |
| 163 | METAL FALSE CEILING WITHOUT SUSPENSION SUPPORT FROM TRUECEILING: Providing & fixing horizontal level suspended metal ceilings comprising of MetalworksF-H600Hook-oncorridorsystemmanufacturedbyArmstrongCeiling SolutionswithRectangularpanelsmadeof0.7mmthickGalvanisedSteel(GI)of 120gsm,postcoatedtoGlobalWhitecolour,suitableforInteriorapplicationsand architecturalfinishes,doublegridconcealedsystemandbuttjointpanels.Thepanel width shall be 300mm, length ranging from 1500mm to 2660mm. General Specifications:Entire system to be designed for Interior applications, and concealed Grid, Buttjointpanels.PanelSpecifications:Material:TheF-H600rectangularHook-on panels to be made of galvanized steel (GI) of minimum 120gsm hot dipped galvanization (both sides included) as per IS 277 (2003), zero or minimum spangled, in minimum base materialthicknessof0.7mmasperinIS:513(1994).Dimensions:ThepanelLength variesbetween1500mmto2660mm,panelWidthshallbe300mm.Thedimensional tolerances for length shall be ±1.0m up to 1000mm L; ±1.5mm between 1001 to 2000mm L; ±2.0mm between 2001 to 3000mm L. The dimensional tolerances for width shall be±0.5mupto300mmW.DimensionalTolerancesforpanelThickness/panelwidth/ panel length - to be measured in accordance with TAIM standards. Edge detail: the panels shall ha+A3ve Square Edge, with a 3mm(W) x 8mm(H) black foam gasket glued at the edges, typically on one long and one short side. All adjacent panels shall touch each other forming a butt joint and concealed grid visuals. Upturns: The short side of the panel shall have vertical upturns of minimum 30mm (H) and shall be bent appropriately bent as per the manufacturer’sspecificationsfor providing hook-onends.The long side shallhave inside horizontal bends of 5-15mm for rigidity and vertical upturns of 40mm (for length rangingfrom1251-2660mm).SurfaceFinish:Plain:Thepanelsshallbeinplain unperforated finish (without any acoustical backing / felt). Colour and finishes: The panel surface shall be electrostatically powder coated (post coat) on visible side after mechanicalproduction,usingRoHScompliantpowder,toachievecoatingthickness ranging from 60-80µ and architectural quality finish. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM First Floor |
| 164 | Second Floor |
| 165 | ProvidingandFixing SoftFibreAcousticalSuspendedCeilingSystemwithOptra (BevelledTegular)EdgeTilesofsize15mmExposedGrid.Thetilesshouldhave HumidityResistance(RH)of95%,NRC0.9-1.0,LightReflectance?85%,Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 66% GW and 74% RW. The tile shall be laid on precoated G.I channel 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200mmand600mmCrossTeeswithawebheightof32mmandaloadcarrying capacity of 7 Kilograms/M2 with a minimum pull out strength of 100 Kilograms. The T SectionshaveaGalvanizingof90gramsperM2andneedtobeinstalledwith SuspensionsystemTheTileandGridsystemusedtogethershouldcarrya10year warranty.products approved as per GRIHA and BS 476 etc. complete.First Floor |
| 166 | Providingandfixing15mmthickeco-friendlydensifiededgecalciumsilicatefalse ceilingof approved texture of size 595mm x 595mm in truehorizontallevel, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at@12gm/sq.mincludingbothsides) consistingofmainTrunnersuitably spaced atjointstogetrequiredlengthandsize24X38mm.madefrom0.33mm thick(minimum ) sheet, spaced 1200mm center to center and cross T of size 24X28mm made of 0.33mm thick(minimum ) sheet to be interlocked at the middle of the 1200x600 mm panel to form the grid of size 600x600mm resting on periphery walls/partitions on a perimeterwallangleprecoated steelofsize24x24x3000madeof0.4mmthick (minimum) sheet withthe help of all plugs at 450mm and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (spintone/cosmos/hexa) in the grid, including light fittings , fixtures , smoke detectors etc., wherever required. Main T runners suspendedfromceilingwithusingG.I.slottedcleatsofsize25x35x1.6mmfixedto ceilingusing12.5mmdia.And50mmlongdashfasteners,4mmG.I.adjustable rods with galvanized steel levels clips of size 85x30x0.8mm, spaced at 1200mm center to center along mainT bottom exposedwith24mm ofall T-sectionsshall be prepaintedwithpolyesterbakedpaint,forallheights,asper specifications,drawingsetc.complete.(currentlythisitem shouldbe usedonlyforVIP cabins) First Floor |
| 167 | Second Floor |
| 168 | PRIVIDINGANDFIXINGANTIMICROBIALACOUSTICALFALSECEILING:Bioguard Mineral Fibre Acoustical Suspended Ceiling System with 19mm thick Acoustics Microlook 90 Edge Tiles with15mm face exposedgrid. The tiles shall have smoothbrightlaminatedvisualwithHumidityResistance(RH)of99%,NRC0.7 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 41db as per ASTM E1414, Light Reflectance ≥87% as per ASTM E-1477, Thermal Conductivity k = 0.052 - 0.057 W/mK, Colour Global White, Fire Performance of Class 0/1 as per BS 476 Part6/7 and Class A as per ASTME84 with19mm Square Tegular/Microlook 90˚edge and8mm dropin module size of 600 x 600mm./ 600x1200mm. The scrim on the face of the tile shall be cleanable, washable up to 500 cycle as per ASTM D-4828 and resistant to disinfectants. ThetileshallbetreatedwithAntiMicrobialcoatingonthefaceofthetile toachieve cleanroom classification of class 5 (Class 100) as per ISO 14644-1 and suitable forzone 4 area having partical emission under normal conditions of ISO 5, Decontamination Class ofCP10andBacteriologicalCleanlinessClassB1forspecificstrainsasperNFS90- 35:2003 The tile shall have a rating of 8 or above (face) for tests conducted for Resistance to growth of Mold in accordance to ASTM D3273. It shall be suitable for Green Building application, with Recycled content of 35% having VOC and Formaldehyde emission rate lessthan0.1mg/m2/hr.ThetileshallhavecertificationsfromGRIHAandGreenPro therebyconfirming thatitisanenvironmentfriendlyproduct.SUSPENSION:Thetile shallbelaidon15mm wideT-sectionflangescolourglobalwhite(matching totile color)having rollformeddouble stroke rotarystitchingonallTsectionsi.e.theMain Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made ofprehardenedsteelandfixedtotheendsofthecrossteetoprovidedoublelocking between“cross tee to cross tee” and“cross tee to mainbeam”. All mainbeam to main beam andcrosstee to crosstee connectionshallhave apulloutstrengthofmore than First Floor |
| 169 | Second Floor |
| 170 | Third Floor |
| 171 | Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete.Ground Floor |
| 172 | First Floor |
| 173 | Second Floor |
| 174 | Third Floor |
| 175 | Fourth Floor |
| 176 | Providing and fixing Country cut teak wood double or single leaf second class fully panelled door shutter with 35mm thick style and rail with 25 mm thick panels with openable fan light as per detailed drawings. Excluding the door frame 60mm x 100mm stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats. (Excluding the door frame)Ground Floor |
| 177 | First Floor |
| 178 | Second Floor |
| 179 | Third Floor |
| 180 | Fourth Floor |
| 181 | Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete.Ground Floor |
| 182 | First Floor |
| 183 | Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock,chromium plated handles on both sides, and finishing with French Polish etc. complete.Ground Floor |
| 184 | First Floor |
| 185 | Providing & Supplying glass ( of saint dobain / asahi / modiguard ) showcase with & 90\" connections shall be with temperd glass 10mm -1200w x 2400 h x 500 d As per drawing with hardware glass to glass angle connector - patch fitting - 82mm (ESPF 1108:82), glass to glassconnector ( SGSF 056 ), glass to glass connection with pin glass (ESH 418 SSS ), glass to glass hinges (ESH 1002), handle knob glass dia 1inch BN finish ( EH 001 BN), cabinet double door glass lock 1007 (EML 1007) ( of Dorma / Hafflle / Enox - Assa Abloy) Including allcutout, lifts, leads, transportation Etc, complete. As directed by engineer incharge.Ground Floor |
| 186 | First Floor |
| 187 | Second Floor |
| 188 | Third Floor |
| 189 | Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 kg/Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 kg/Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Running Metre. and handle and top section 40 x 18 x 1.25 mm at weight o.417 kg/Running Metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as rollerbearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with boxGround Floor |
| 190 | First Floor |
| 191 | Second Floor |
| 192 | Third Floor |
| 193 | Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12 mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clear space of 150 mm between two sets of crossings with hold fasts, stoppers, spaces,handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). Ground Floor |
| 194 | First Floor |
| 195 | Second Floor |
| 196 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete.Ground Floor |
| 197 | First Floor |
| 198 | Second Floor |
| 199 | Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coat of metel primer of approved make and manufacture. M.S frame shall be covered with heat mouled PVC \"C\" channel made from 5 mm (+/0.25) thick prelaminated sheet of density 600 kg/cbm ,of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ; and 5 mm thick ,95 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the \" c \" channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/sealed to the styles and rails with 5 mm (+/0.25) x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 Number ) 20 mm wide Ground Floor |
| 200 | First Floor |
| 201 | Second Floor |
| 202 | Third Floor |
| 203 | Providing and fixing mild steel grill work for windows, ventilators etc.20 kg/Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.Ground Floor |
| 204 | First Floor |
| 205 | Second Floor |
| 206 | Third Floor |
| 207 | Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) Ground Floor |
| 208 | First Floor |
| 209 | Second Floor |
| 210 | Third Floor |
| 211 | Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm withironbarsat150mm C/Canddiagonalflatsasperthedetaileddrawingincluding hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kilogram/Smt. |
| 212 | Providing and fixing of factory made uPVC Sliding window & door (WhiteColour) complete,comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm(+-0.2mm),duly reinforced with G.I. section 1.5mm,wherever required. uPVCwindow&doorprofileshallbemadeinIndia &shall confoRunning MetreoBSEN12608andother standards asmentionedbelow: S.No. Name of the testTest MethodSpecified Parameter1TensileImpactStrength ISO8256-morethan 700Kj/m2 2VicatSoftening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 \"P\" Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPaAll corners of frame and sash will be fusion welded.After placing 5mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM/TPE gasket, brushshall be provided including touch lock and rollers & proper drainage system shall be provided.Ground Floor Window/Doorwillbefixedtothewallwith100mmlongand8mmdia.Fastenersand completeinallrespectasperdirectionofEngineer-In-Charge. uPVCWindowandDoor Profilesarewarrantedforaperiodof ten(10)yearsagainstnon-uniformdiscoloration, wrapping and rotting under general use. 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window)(Big Series) Window frame of size 122 x 54 mm & Sash of size 64 x 47 mm.Ground Floor |
| 213 | First Floor |
| 214 | Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete.First Floor |
| 215 | Second Floor |
| 216 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. |
| 217 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent ofclorophyrifosper square metre of surface area covering ten years guarantee on bond paper. |
| 218 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper. |
| 219 | Providing, supplying and fixing in position various type of sanitary fixture as list below of jaquar make only including all neccesary fixtures fastening as requred to complete the work testing and commissioning etc complete. Bib Tap |
| 220 | Providing, supplying and fixing in position various type of sanitary fixture as list below of jaquar make only including all neccesary fixtures fastening as requred to complete the work testing and commissioning etc complete. Angle Cock |
| 221 | Providing, supplying and fixing in position various type of sanitary fixture as list below of jaquar make only including all neccesary fixtures fastening as requred to complete the work testing and commissioning etc complete. Pillar Cock |
| 222 | Providing, supplying and fixing in position various type of sanitary fixture as list below of jaquar make only including all neccesary fixtures fastening as requred to complete the work testing and commissioning etc complete. Metroflush valve |
| 223 | Providing, supplying and fixing in position various type of sanitary fixture as list below of jaquar make only including all neccesary fixtures fastening as requred to complete the work testing and commissioning etc complete. Sink Tap |
| 224 | Providing, supplying and fixing in position various type of sanitary fixture as list below of jaquar make only including all neccesary fixtures fastening as requred to complete the work testing and commissioning etc complete. Wall Mixer Unit |
| 225 | Providing, supplying and fixing in position various type of sanitary fixture as list below of jaquar make only including all neccesary fixtures fastening as requred to complete the work testing and commissioning etc complete. Towel Rod ( Kubix Prime) |
| 226 | Providing, supplying and fixing in position various type of sanitary fixture as list below of jaquar make only including all neccesary fixtures fastening as requred to complete the work testing and commissioning etc complete. Towel Ring |
| 227 | Providing, supplying and fixing in position various type of sanitary fixture as list below of jaquar make only including all neccesary fixtures fastening as requred to complete the work testing and commissioning etc complete. Soap Dispensar |
| 228 | Providing, supplying and fixing in position various type of sanitary fixture as list below of jaquar make only including all neccesary fixtures fastening as requred to complete the work testing and commissioning etc complete. Soap Dish Holder First Floor |
| 229 | Second Floor |
| 230 | Providing, supplying and fixing in position various type of sanitary fixture as list below of jaquar make only including all neccesary fixtures fastening as requred to complete the work testing and commissioning etc complete. Grab Bar First Floor |
| 231 | Second Floor |
| 232 | Providing, supplying and fixing in position various type of sanitary fixture as list below of jaquar make only including all neccesary fixtures fastening as requred to complete the work testing and commissioning etc complete. Towel Rack |
| 233 | Providing, supplying and fixing in position various type of sanitary fixture as list below of jaquar make only including all neccesary fixtures fastening as requred to complete the work testing and commissioning etc complete. Toilet Paper Holder |
| 234 | Providing, supplying and fixing in position various type of sanitary fixture as list below of jaquar make only including all neccesary fixtures fastening as requred to complete the work testing and commissioning etc complete. Coat Hook Ground Floor |
| 235 | Second Floor |
| 236 | Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litresThird Floor |
| 237 | Providingand fixingon walls/ceiling/floor20 mmdia. uPVCpipewith necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Ground Floor |
| 238 | First Floor |
| 239 | Second Floor |
| 240 | Providingandfixingonwalls/ceiling/floor25mmdia.uPVCpipewith necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Ground Floor |
| 241 | First Floor |
| 242 | Second Floor |
| 243 | Providingandfixingonwalls/ceiling/floor32mmdia.uPVCpipewith necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWDchowky or as directed etc. complete.Ground Floor |
| 244 | First Floor |
| 245 | Second Floor |
| 246 | Providingandfixingonwalls/ceiling/floor40mmdia.uPVCpipewith necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Ground Floor |
| 247 | First Floor |
| 248 | Second Floor |
| 249 | Providing and fixing on walls/ ceiling/ floor 50 mm dia. uPVC pipe withnecessary fittings, remaking good the demolished portion etc. complete.Ground Floor |
| 250 | First Floor |
| 251 | Second Floor |
| 252 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc.complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete.Ground Floor |
| 253 | First Floor |
| 254 | Second Floor |
| 255 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete.Ground Floor |
| 256 | First Floor |
| 257 | Second Floor |
| 258 | Providing and fixing on walls/ceiling/floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete.Ground Floor |
| 259 | First Floor |
| 260 | Second Floor |
| 261 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete.Ground Floor |
| 262 | First Floor |
| 263 | Second Floor |
| 264 | Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc.complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete.Ground Floor |
| 265 | First Floor |
| 266 | Second Floor |
| 267 | Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc.complete.Ground Floor |
| 268 | First Floor |
| 269 | Second Floor |
| 270 | ProvidingandfixingC.P.BIBcockwithwallflangeofapprovedmake including necessary sockets/ union nut etc. complete.(Jaquar Make) Ground Floor |
| 271 | First Floor |
| 272 | Second Floor |
| 273 | ProvidingandfixingC.P.2WayBIBcockwithwallflange ofapproved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.Ground Floor |
| 274 | First Floor |
| 275 | Second Floor |
| 276 | Providing and fixing 20 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete.Ground Floor |
| 277 | First Floor |
| 278 | Second Floor |
| 279 | Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.Ground Floor |
| 280 | First Floor |
| 281 | Second Floor |
| 282 | Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.Ground Floor |
| 283 | First Floor |
| 284 | Second Floor |
| 285 | Providing and fixing screw down for 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.Ground Floor |
| 286 | First Floor |
| 287 | Second Floor |
| 288 | Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.Ground Floor |
| 289 | First Floor |
| 290 | Second Floor |
| 291 | Providing andfixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete.Ground Floor |
| 292 | First Floor |
| 293 | Second Floor |
| 294 | Providingandfixing100mmdiameterwatermeterwithnon-returnvalveincludingstrainer, sockets/ union nut and including water meter box making locking arrangementsandlock. [Without chamber].Ground Floor |
| 295 | First Floor |
| 296 | Second Floor |
| 297 | Providing and fixing orissa type colour glazed earthenware 625 x 450 mm. w.c. pan including trap, C.I. soil and vent pipe upto the out side face of wall including 100 mm. dia. C.I. plug, bend, 15mm. thick 10 litre PVC flushing cistern with all necessary pipe connection etc.complete.(a) With 10 litre UPVC high level flushing cistern with fittings.First Floor |
| 298 | Providing and fixing European type Colour glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 liter enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.( prior approval of sample and brand by Ex. Engineer is necessary before use) First Floor |
| 299 | Second Floor |
| 300 | Providing and fixing white glazed urinal of size 710x460x300mm with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32mm diameter P.V.C. flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete.First Floor |
| 301 | Second Floor |
| 302 | Providing and fixing white european type wall-hung pan, of size 350mm x 355mm x 570 mm concealed flush tank with floor-mounting frame installing kit and drain pipeconnection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete.Ground Floor |
| 303 | First Floor |
| 304 | Second Floor |
| 305 | Providing and fixingOval Type Under Counter Wash Hand Basin of 420 x 590 x 195mm size with pillar cock, C.P.Angular stop cock, long thread of approvedmake continental includingSSbottletrapof necessarypipeconnectionuptothe outside faceofthewall, havingTelephonicBlack/ColourGraniteof180mm thickfixed onBlackKadappa Framework, etc. Complete as directed by Engineer in charge.Ground Floor |
| 306 | First Floor |
| 307 | Second Floor |
| 308 | Providingandfixingstainlesssteelsinkofsize600x510x200mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete.Ground Floor |
| 309 | Providing and fixingsink cock with regular swinging spout (Wall / floor Mounted Model) withwallflangehavingflowrateupto 6.0Litr/MinuteofJaquar / Cera /Hindware / Perryware or equivalentmake incluidng other necessary fitting, etc. complete as directed by Engineer in charge.( Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.) Ground Floor |
| 310 | Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 cm and one no SS 304 hinged rail 76 cms & three no SS 304of (Grab Bar) 60 cms all including cutting and making good the walls and floors wherever required ,seat cover, cistern & wash basin fittings,nuts, bolts and gasket etc complete as per the direction ofEngineer-In-charge Ground Floor |
| 311 | Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use)Ground Floor |
| 312 | First Floor |
| 313 | Second Floor |
| 314 | Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. |
| 315 | Providing, layingand fixingP.V.C. pipeof 50mmdia. with fittings such as bends,tees,reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removingexistingpipe lineifnecessaryandconveyingand stackingthesameinPWD chowky or as directed etc. complete.Ground Floor |
| 316 | Providing, layingand fixingP.V.C. pipeof 75mmdia. with fittings such as bends,tees,reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removingexistingpipe lineifnecessaryandconveyingand stackingthesameinPWD chowky or as directed etc. complete.Ground Floor |
| 317 | Providing, laying andfixing P.V.C. pipe of 110mm. dia. withfittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removingexistingpipelineif necessaryandconveyingandstackingthe sameinPWD chowky or as directed etc. complete. |
| 318 | Providing , laying and fixing ,jointing Eco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc.complete.(c) 160 mm dia. Pipe |
| 319 | Providing , laying and fixing ,jointing Eco- drain 200 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc.complete. |
| 320 | Providing , laying and fixing ,jointing Eco- drain 250 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc.complete. |
| 321 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592- 1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc.complete. Ground Floor |
| 322 | First Floor |
| 323 | Second Floor |
| 324 | Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 325 | Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.Ground Floor |
| 326 | First Floor |
| 327 | Second Floor |
| 328 | Providing and fixing chromium plated towel rod 16 mm dia and 75 cm.in length including all accessories complete.Ground Floor |
| 329 | First Floor |
| 330 | Second Floor |
| 331 | Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete. |
| 332 | Providing , constructing and fixing 450 mm dia. Inspection chamber made up of Polypropylene / polyethylene material of thickness 3.5 mm and height of 388 mm with 160 or 200 mm main inlet (s) outlet and 110 and / or 160 mm branch inlets, with 450mm dia. Ultra shaft pipe of HDPE material having height of 460 mm, having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete. |
| 333 | Providing , constructing and fixing 600 mm dia. Inspection chamber made up of Polypropylene / polyethylene material Having 315 mm diameter inlet(s)/outlets and with eccentric reducers as per requirement to connect 160 mm and 200 mm pipes having thickness of 5 mm and 600 mm in height, with inbuilt shaft achieve the invert depth as per site condition of wall thickness of 5 mm having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia.Including excavation and refilling the sides of chamber by ?sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc.complete. |
| 334 | RWH - Recharge PitProviding and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCCrings with 6.5\" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annularspace) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC endcaps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge. |
| 335 | ProvidingandinstallingbiodigesterunitbasedonDRDOtechnologymadeof fibre reinforcedplastic(FRP)havingcompositionandfollowingtechnical specificationsand includingnecessary pipeandaccessoriesupto3meterlength, excludingthenecessary excavation for installing the bio digester.Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mmOutlet pipe size rigid PVC:-80mmGas outlet rigid PVC with Valve: 20mmBacteria immobilization PVC mattes (on all partition) WithDRDOTOTlicenseeandlatestbatchcertificate(month&yearofsupply) and capacity as below i) Upto 200 user size(4m x 2.0m x 1.25m),Capacity of Biodigester:-10000 liters,Area of top,bottom and side walls:-31.00 sq.m, Area of partition walls:10.00sq.m,Total weight of FRP:-462.60 Kilogram,Bacteria in oculums quantity:-3400 liters, Minimum thickness of side walls/top and bottom:7mm,One Number of inside partitions:-4,Minimum thickness of partition wall: 4mm |
| 336 | Providing and fabricating structural steel work in rolled sections, fixed with connecting plates or angle cleats in main and cross beams, hip and jack rafters, purlins connecting to truss members and the like, as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/ bolted/ welded connections and one coat of anticorrosive paint and over it two coats of oil paintingofapproved quality and shade etc. complete. |
| 337 | Providingstructuralsteelworkinhollowsectionofvariousthicknessandsizesin square, rectanular and round shape from 25mm to 450mmsection as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and paintingcomplete.Fouth Floor |
| 338 | Design supply & installation of structural glazing consisting of Jindal make colour anodized alluminium sections 50x50x1.8 mm , anchoring the main frame tosubstrate with M.S brackets , Hilti make anchors , pasting 5 mm thick tintedtoughenedglass of Saint Gobain make with Lohmann make VHB tape, striking out the joints with weather silicon Dow 789 , labour etc complete.First Floor |
| 339 | Second Floor |
| 340 | Third Floor |
| 341 | Supplyingandfixingof6mmthickExteriorCompactLaminateorHighPressure Laminate of approved colour by approving authority with UV resistant Decorative colour paperonbothsidetypicallymadeoutofmultiplelayersofcraftpapersandthen impregnatedwiththermosettingphenolicresins,ontopofitmelaminetreatedbarrier paperanddecorativepaperandwearlayeronboththesidessaturatedwithmelamine resins andthen covered withUV resistant acrylic resin layer whichmakes it extremely durableandweatherresistantcompressedtogetheron extremelyhighpressureand hardened with electron beam curing to get the total desired thickness of 6mm matching EuropeanstandardspecificationasperEN438-part6,protectedwith60Micron protective peel-off film on both side which in no case leave any adhesive mark over the panel surface after it is peeled off. Fixing of the same to be done on a supporting frame of 50 mm X 5 mm X 3 mm powder coated aluminium box section to be spaced horizontally andverticallyin600mmX600mmgridandfixedtobuildingstructureasperdesign through50mmX50mmXmm5mmMSanglebracketprefixedtomasonryslabor columns with Hilti make anchor fastener along with all related hardware and fixtures. The panelshouldthenbefixedontheAluminiumsectionwiththehelpofpurepolyester exteriorgradecolourcoatingrivetsasperarchitecturaldrawingsorasdirectedby Engineer-in-charge.Eachpanelshouldbe rivetedonsubstructure maintaining a gapof 6mmonallthesidesbetweeneachPanelforAircirculationandexpansionand contraction as per installation specifications provided by the manufacturer. The cost shall includeall expenses related to storage, material handling, lifting, freight, labour, scaffolding etc as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate)Ground Floor |
| 342 | First Floor |
| 343 | Second Floor |
| 344 | Fourth Floor |
| 345 | Providing & Fixing Beam Column Corner Guards with necessary fixture etc complete . |
| 346 | Providing & Fixing Rubber speed breakers 4 m long having bearing capcity of 2 Tonne with fixtures etc complete . |
| 347 | Providing & Fixing Convex mirror at parking area with necessary fixture etc complete. |
| 348 | ProvidingandFixingVerticalBlindsofapprovedMakeandshadeof100mmregular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work) Ground Floor |
| 349 | First Floor |
| 350 | Second Floor |
| 351 | Third Floor |
| 352 | ProvidingandFixingRollarBlindsAMIMakeorapprovedmake&shadeof38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work) Ground Floor |
| 353 | First Floor |
| 354 | Second Floor |
| 355 | Third Floor |
| 356 | Providing& Arrangemnt of High Back, Synchronized Mechanismwith Multiple Locking,AdjustableArmrest,GasliftforSeatheightadjustment,Standard5-prong P/Nylon Basewith Leatherite Upholstery First Floor |
| 357 | Second Floor |
| 358 | Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery Ground Floor |
| 359 | First Floor |
| 360 | Second Floor |
| 361 | Third Floor |
| 362 | Providing & Fixing Curviliner workstation @ 1500/1500Lx600/600Dx750HTProviding &Fixing Curviliner Workstation@ 500/1500Lx600/600Dx750HT, CurvilinearTableTop@1500/1500Lx600/600D:-TOPtobemadeof25mmthick Prelaminated particle board with PVC edge band,GABLE END to be made of 25 mm thick Prelaminated particle board with PVC edge band, KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :-Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, along with 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board,First Floor |
| 363 | Second Floor |
| 364 | Medium Height Steel Storage @ 750Lx450Dx1200HTProviding and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in0.8 mm thick & Top in 2 mm thick CRCA, 2 Shuttertobemountedwiththehelpofcuphinges,and4adjustablelevelers,enitre storage in powder coated finish with 60 to 80 microns. with 25 mm. thk. as per drawing. First Floor |
| 365 | Second Floor |
| 366 | Third Floor |
| 367 | Executive\"sTable @ 1800Lx900Dx750HTProviding & Fixing of Table @ 1800Lx900Dx750HT - TOP & GABLE END to be made ofMembrane finishwithsoftwater falledges &curvedpanel& DecoratedAnodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawing.First Floor |
| 368 | Second Floor |
| 369 | Third Floor |
| 370 | Free Standing Table @ 1200Lx600Dx750HTProvidingandfixingTableofSize1200x600x750mm.Top:madefrom25mm PrelaminatedParticleboard. Alledgesarecoveredby2mm.Thk.PVCedgebands glued by hot melt glue applied by auto edge banding machine.Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY(WITHOUTMOUSETRAY):- MetalPowderCoated-BlackColor,CPU TROLLEY:- MetalPowderCoated-BlackColor,3DRAWERPEDESTALUNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminatedparticle board,First Floor |
| 371 | Second Floor |
| 372 | Conference Table @ 3600Lx1400Dx750HTProviding&FixingofMainTable@3600Lx1400Dx750HT-madeupof18+18mm ThickMDFtopwithPVCMembranefinishandwaterfalledgeprofile.Aluminium Anodizied finish beeding of 4mm thich is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in PVC Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from inside for the provision of passing electrical and Data wiring. , MODESTY PANEL:- to be made of 18 mm thick Prelaminated particle board with PVC edge bandAccess Flap:- For Wire manager 2 Number.First Floor |
| 373 | Stool for Lab and Class-IVProvidingandfixing4leggedLabstool,Legsmadeof16Guage45MMOuter dimensionMS Pipe, Duly painted, With a 304Grade Stainlesssteel 12inchwide seat witha1inchcollar,Heightadjustmentviaascrew.asperdesignanddrawingand instructions of Engineer in charge.Ground Floor |
| 374 | First Floor |
| 375 | Second Floor |
| 376 | Sofa Set 3+1+1Providing&fixing SofaSet3+1+1BrownandCreamleatherDIMENSIONLength:182.5 (cms)Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat First Floor |
| 377 | Second Floor |
| 378 | Tea Table 900mm X 750mm X 450mm for m.s. ante chamberProvidingAndFixingOfTeaTable900mmX750mmX450mmWith12mmThick ColourEitchedTemperedGlassWithBevelledDrawingMadeOut Of18mmThick WaterproofingPly.TheOuterLacesToBeFinishedWithHighQuality4MmThik Veneer Or 1 Mm Thik Mica etc.complete. First Floor |
| 379 | Second Floor |
| 380 | Single Faced Fixed Unit for Compactor 2150mmH x 2745mmW x 457mmDProviding and fixing Single Faced Fixed Unit for Compactor 2150mmH x 2745mmW x 457mmD -BASEFRAME:BaseFrameshallbefabricatedinchannelTypefrom minimum 2.5 mm thick MS Sheet Size of Channel25mm x 100mm x 45mm.GUIDE RAILS : The guide rails shall be made out of 28mm Bright bar placed on 1.2 mm thick M.S. Plate which will be above the floor and are as per the international standard of safety.SUPERSTRUCTURE:SuperstructureoftheMobilestoragesystemwillconsistof knockdowntypepanels. Allthecomponentssuchasshelves,frontpanel,endpanel, verticalrearpanel,centralpartitionetc.WillactasanintegralmemberoftheUnit. SHELVES:Shelvesmadeof22SWGthickPrimeQualityC.R.C.A.having10 folds eachwillbeprovided eachdesignedtocarryaU.D.L.of70Kilograms.VERTICAL PANEL :Vertical panel consists of the front, Centre & rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to covertheentiredrivemechanism.CENTREPARTITION:TheCentrepartitionwill compriseofafullC.R.C.A.primequalityMildSteel22SWGSheet.LOCKING : Systemwillbeprovided withindividualracklockingaswellascentralisedlocking arrangementonthelastunitwhenallunitsarebroughttogether, centrallockwhen operatedgetslockedwiththefloor&doesnotallowaccesstotheunits.DRIVE MECHANISM:Driving Mechanismwill be provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000mm x 200mm x 60mm.DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acryliccard holders provided on the front panelfor easyidentification&retrieval.FINALFINISH:PowderCoating(8tanks process with 70 microns).Third Floor |
| 381 | Single Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 457mmDProviding and fixing Single Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 457mmD -BASEFRAME:BaseFrameshallbefabricatedinchannelTypefrom minimum 2.5 mm thick MS Sheet Size of Channel25mm x 100mm x 45mm.GUIDE RAILS : The guide rails shall be made out of 28mm Bright bar placed on 1.2 mm thick M.S. Plate which will be above the floor and are as per the international standard of safety.SUPERSTRUCTURE:SuperstructureoftheMobilestoragesystemwillconsistof knockdowntypepanels. Allthecomponentssuchasshelves,frontpanel,endpanel, verticalrearpanel,centralpartitionetc.WillactasanintegralmemberoftheUnit. SHELVES:Shelvesmadeof22SWGthickPrimeQualityC.R.C.A.having10 folds eachwillbeprovided eachdesignedtocarryaU.D.L.of70Kilograms.VERTICAL PANEL :Vertical panel consists of the front, Centre & rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to covertheentiredrivemechanism.CENTREPARTITION:TheCentrepartitionwill compriseofafullC.R.C.A.primequalityMildSteel22SWGSheet.LOCKING : Systemwillbeprovidedwithindividualracklockingaswellascentralisedlocking arrangementonthelastunitwhenallunitsarebroughttogether, centrallockwhen operatedgetslockedwiththefloor&doesnotallowaccesstotheunits.DRIVE MECHANISM:Driving Mechanismwill be provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000mm x 200mm x 60mm.DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acryliccard holders provided on the front panelfor easyidentification&retrieval.FINALFINISH:PowderCoating(8tanks process with 70 microns).Third Floor |
| 382 | Double Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 900mmDProviding and fixing Double Faced Mobile Unit for Compactor 2150mmH x 2745mmW x900mmD -BASEFRAME:BaseFrameshallbefabricatedinchannelTypefrom minimum 2.5 mm thick MS Sheet Size of Channel25mm x 100mm x 45mm.GUIDE RAILS : The guide rails shall be made out of 28mm Bright bar placed on 1.2 mm thick M.S. Plate which will be above the floor and are as per the international standard of safety.SUPERSTRUCTURE:SuperstructureoftheMobilestoragesystemwillconsistof knockdowntypepanels. Allthecomponentssuchasshelves,frontpanel,endpanel, verticalrearpanel,centralpartitionetc.WillactasanintegralmemberoftheUnit. SHELVES:Shelvesmadeof22SWGthickPrimeQualityC.R.C.A.having10 folds eachwillbeprovided eachdesignedtocarryaU.D.L.of70Kilograms.VERTICAL PANEL :Vertical panel consists of the front, Centre & rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to covertheentiredrivemechanism.CENTREPARTITION:TheCentrepartitionwill compriseofafullC.R.C.A.primequalityMildSteel22SWGSheet.LOCKING : Systemwillbeprovidedwithindividualracklockingaswellascentralisedlocking arrangementonthelastunitwhenallunitsarebroughttogether, centrallockwhen operatedgetslockedwiththefloor&doesnotallowaccesstotheunits.DRIVE MECHANISM:Driving Mechanismwill be provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000mm x 200mm x 60mm.DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acryliccard holders provided on the front panelfor easyidentification&retrieval.FINALFINISH:PowderCoating(8tanks process with 70 microns).Third Floor |
| 383 | Medium Height Partition @ 1800/1200HT TILE BASED PARTITION SYSTEMTilebasedAluminumpartitionsystemof1800/1200mmht.madeof60mmthick aluminum frames having two separate race ways for laying electrical & computer wiring. The wire management shall be through to the race way to be fitted at bottom of partition other immediately below of work top with hook on type raceway cover for easy access of wires.FramestobejoinedbyaluminumconnectorswithM6x16pan-headmachine screw and washer with aluminum post cover. Post cover snap on fashion to be connected on aluminum connector visible aluminium to be in anodized / powdercoated finish. The top exposed sides of the frame and posts should be covered with horizontal/ Vertical trim andcaps made of Aluminum in anodized / powdercoated finish in order to enhance its look.Upper tiles on the partition to be in Soft Board or Marker or prelaminated partical board tile of 9mm. thk., prelaminated partical board lower tiles in laminate finish 9mm. thk. on both the sides .Size :- 1200/1800mm (H)First Floor |
| 384 | Second Floor |
| 385 | Providing&Fixinginposition,AcousticalPanellingmadefrom Fabricwrapped Compressed polyester fibre nonwoven 9 mmpanels on, 50 x 50 mm sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 gsmsyntheticwool50mmthickwithchickenmeshonwallside,includingcostof requiredCut-Outs, decorative mouldings / finishing-items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete.First Floor |
| 386 | Second Floor |
| 387 | Directional signage Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) directional signboards of size 6 x 9\" designed as per accessibility standards and having 4mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate and having a bon glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200mm from FFL and as per the directions by the engineer incharge.First Floor |
| 388 | Second Floor |
| 389 | Supplying and installation of high back revolving chair as per detailed specifications including cost of materials, fixtures & fasteners, labour,packing, transportation and fixing/ placing as indicated in drawing etc. complete. |
| 390 | Supplying and installation of 4 Seater PU Coated Canteen table size: 1135 W x 1175 D x 750 H. as per detailed specifications including cost of materials, fixtures & fasteners, labour, packing, transportation and fixing / placing as indicated in drawing etc. complete. |
| 391 | Supplying and installation of Modular Kitchen-Colour -Berry Brunch as per detailed specifications including cost of materials, fixtures & fasteners, labour, packing, transportation and fixing / placing as indicated in drawing etc. complete. |
| 392 | Providing and fixing 12 mm thk. Clear glass with edge polishing and bevelling including all necessary Hardware, lead, lift and labour charges etc. complete.First Floor |
| 393 | Second Floor |
| 394 | S.S brushed push/pull signage with 200mmx 50mm small rectangural proportion for the door, (by vendor) as approved by the architect.Ground Floor |
| 395 | First Floor |
| 396 | Second Floor |
| 397 | Third Floor |
| 398 | Providing and fixing panelling, 19mm BWR plywood make by century ply, finish with 4mm thk veneer century lam, panelling fixed with ss. screws and nails, veneer fixed with 6mm thk press beading Patti and nails, ply joint with joint pin, including fevicoll, lead, lift and labour charges etc. complete. First Floor |
| 399 | Second Floor |
| 400 | Providing and fixing wooden pelmet make in 19mm BWR century plywood, pelmet height 18\" and with from brick wall 3\", make support in plywood in L shape fixed in top and bottom from above 6\", bottom plywood edge cover with 1-1/2\" wide plywood patta, pelmet finish with veneer, pelmet fixed with S.S. screws and nails, 6mm thk beading, and press beading patti for fixing veneer, fevicoll, including all necessary hardware, lead, lift and labour charges etc. complete. pelmet all detail refer by architectural drawing, veneer and plywood make by century.First Floor |
| 401 | Second Floor |
| 402 | Providing & fixing vinyl Clear printed graphic film with required backing material fixed using film adhesive. Vendor shall include wastage while quoting. Vendor shall provide 10 year warranty as per manufacturer\"s guidelines. Desien of the graphics to be included.FIrst Floor |
| 403 | Second Floor |
| 404 | Providing and fixing forsted film, including lead lift and labour charges etc. complete. Providing and fixing forsted film, including lead lift and labour charges etc. complete.First Floor |
| 405 | Second Floor |
| 406 | Supplying and placing of dormitory rack with size 1200x2100x400mm shall be with back panel thickness 9mm , side panel, door, self thickness 17.2 mm rack with 2 self + 1 full hanger space, 1 drawer, with handle, made of MDF, having CNC designing work , finished with paint, wardrobe colour in rust teak, product shall be according export quality standard with 12 month warrenty ( part replasment), production unit shall be ISO Approved make - Wipro,gogrej, HNI. Including all cutout, lifts, leads, transportation Etc,complete. As directed by engineer incharge. First Floor |
| 407 | Second Floor |
| 408 | Cement Pot: - Good quality, durable, well finished on edge with good strength.36” x 18” x 18” |
| 409 | Cement Pot: - Good quality, durable, well finished on edge with good strength.24” x 12” x 12” |
| 410 | Instatnt Lawn 20cm :- Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 20 cms.consolidated thickness). Supplying on site well decomposed Farm Yard Manure for excavation area of depth of 20 cms. ( consolidated thickness). Providing on site well established (free from weeds /diesease etc.) ready to fix lawn turf in slabs/ rolls of required variety as directed .Excavation for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs. for a depth of 20 cms.Filling fresh garden soil / silt & manure in excavated area of depth 20cms.Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 20 cms. for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed/ ground cover. (1/10 of semiskilled labour) Maintainance of Newly Developed lawn(Instant Lawn) Area. For First 30 days |
| 411 | Lawn Grasses:- American blue grass, Selection No.1 / Barmuda & Pasphallum Grass.( 1 kg Loose lawn covers 2 sq.ft area i.e 6 kg for 1 Sq.Mtr Area .) |
| 412 | Lawn Grasses:- Mexican or Korian Grass Turf , Selection No.1 American blue grass, / Barmuda etc ready to fix lawn turf in Slabs/ Rolls of required variety as directed Rates Including breakage,&Transportation Damage losses. |
| 413 | GARDEN SOIL:-Supplying on site garden soil well sieved 80 % to pass through I.S. sieve of 10 mm size free from stones rubbish like dried grass roots and other such materials. The soil should be fresh from quarry. The color of the soil generally is red. The soil will be measured by measuring box. (Farma) Item includes Transporting, loading -unloading etc (.Lead charges per 25 km. considered Excluding royalty.) |
| 414 | FARM YARD MANURE:-Supplying on site well decayed, well dried, well powdered, without clods and free from stones, dried grass and other rubbish material. The color of the manure generally is black. The manure will be measured by measuring box.(Farma)Item includes Transporting, loading -unloading etc (.Lead charges per 20 km. considered.) |
| 415 | Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 30 cms.( consolidated thickness).(As per P&G DSR2022-23 Items of garden work,Sr No.36a) Shrubbery (spacing - 30 x 30cm) for 1 sqm required 9 plants. |
| 416 | Supplying on site well decomposed Farm Yard Manurefor excavation area of depth of 30 cms. ( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.36b)Shrubbery (spacing - 30 x 30cm) for 1 sqm required 9 plants. |
| 417 | Excavation for planting lawn/ shrub/ flower bed/ hedges/edges/cannabedinearth,soilofall types, soft murum, including removing the excavatedmaterialuptoadistanceof50mtrs. for adepth of 30cms.(Asper P&GDSR 2022-23 Items of garden work,Sr No.3) |
| 418 | Fillingfreshgardensoil/silt&manure in excavatedareaofdepth30cms.(1/10of unskilledlabour)(AsperP&GDSR2022-23 Items of garden work,Sr No.13) |
| 419 | Mixing garden soil/silt & manurethoroughly well,wateringpreviousnight.Plantingreqired plant species, lawn grass as directed etc. complete for required depth 30 cms. for planting lawn/shrub/flowerbed/hedges/edges/canna bed/ ground cover. (1/10 of semiskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.23) |
| 420 | ProvidingonsiterequiredvarietyofShrub height is (30 cm to 45 cm ) Mogara/Jasminum-Bag Size 9\"x11\" |
| 421 | ProvidingonsiterequiredvarietyofShrub height is (30 cm to 45 cm ) Hibiscus - Bag Size 8 \" X 10\" |
| 422 | ProvidingonsiterequiredvarietyofShrub height is (30 cm to 45 cm ) Nerium- Bag Size 8\" x 10\" |
| 423 | ProvidingonsiterequiredvarietyofShrub height is (30 cm to 45 cm ) Nerium dwarf- Bag Size 8\" x 10\" |
| 424 | ProvidingonsiterequiredvarietyofShrub height is (30 cm to 45 cm ) Ixora mini Bag size 8\" x 10\" |
| 425 | ProvidingonsiterequiredvarietyofShrub height is (30 cm to 45 cm ) Bongainvillea Common Bag size 8\" x 10\" |
| 426 | ProvidingonsiterequiredvarietyofShrub height is (30 cm to 45 cm ) Ratrani/Night queen( bag size 8\" x 10\") |
| 427 | Supplying on site fresh Garden soil (i. e. 3 part soil) (free from stones rubbish like dried grass roots, other such materials) for excavated pit size area of 0.60 x 0.60 x 0.60m (consolidated thickness).Quantity of soil 0.141 cum x 800/cum=112.80/- Ornamental Plant Spacing (30.0 x 30.0cm) |
| 428 | Supplying on site well decomposed Farm Yard Manure FYM (i. e. 1 part FYM) for excavated pit size area of 0.60 x 0.60 x 0.60m (consolidated thickness). Quantity of FYM 0.044 cum x 950/cum = 41.80/- |
| 429 | Excavation pit size 0.60 x 0.60 x 0.60m for planting small & medium ornamental plants/ large flowering/ shady trees (plant height 1 to 2 cmtr.)/ palm varieties upto height 1 to 2 mtrs. in earth, soil of all types, soft murum, including removing the excavated & unwanted material up to la required distance of 50 mtrs. |
| 430 | Filling fresh garden soil / silt & manure in excavated pit size area of 0.60 x 0.60 x 0.60m. |
| 431 | Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species as directed etc. complete for required pit size 0.60 x 0.60 x 0.60m. |
| 432 | Providing on site required variety of Ornamental Plant (free from weeds /diesease etc.) Gulmohar (Bag size 18\" x 18\") (8 ft to 10 ft) |
| 433 | Providing on site required variety of Ornamental Plant (free from weeds /diesease etc.) Kadamb (Bag size 18\" x 18\") (8 ft to 10 ft) |
| 434 | Providing on site required variety of Ornamental Plant (free from weeds /diesease etc.) Sita ashok(Bag size 18\" x 18\") (8 ft to 10 ft) |
| 435 | Providing on site required variety of Ornamental Plant (free from weeds /diesease etc.) Bakul(bag size 18\" x 18\")(8 ft to 10 ft) |
| 436 | Providing on site required variety of Ornamental Plant (free from weeds /diesease etc.)Peepal (bag size 18\" x 18\") (8 ft to 10 ft) |
| 437 | Providing on site required variety of Ornamental Plant (free from weeds /diesease etc.)Wad/banyan(bag size 18\" x 18\") (8 ft to 10 ft) |
| 438 | Providing on site required variety of Ornamental Plant (free from weeds /diesease etc.) KaduNeem(bag size 13\" x 13\") (8 ft to 10 ft) |
| 439 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. withnecessary accessories in wall/floor with chiselling appropriately as perspecification No: WG-MA/CC. |
| 440 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 441 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as perspecification No: WG-MA/CC. |
| 442 | Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 443 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 444 | Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW (For Earth- green color ) |
| 445 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(for power & IP comp board circuit) |
| 446 | Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(for power & IP comp board circuit) ( Rate reference taken from Note-1) |
| 447 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 448 | Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 449 | Supplying and erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specificationNo:WG-MA/BW(NOTE-1) |
| 450 | Supplying and erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(NOTE-1) |
| 451 | Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(NOTE-1) |
| 452 | Supplying and erecting mains with 2x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 453 | Supplying and erecting mains with 1x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 454 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 455 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 456 | Supplying and erecting modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. (for AC-17) |
| 457 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 458 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 459 | Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete. |
| 460 | Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 461 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 462 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 463 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 464 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 465 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 466 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background. |
| 467 | Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit /casingn capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW |
| 468 | Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 469 | Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG PW/CW |
| 470 | Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/ CW |
| 471 | Supplying erecting ready to useRetrofitT8 LED18/20 tubelight with polycarbonatebody,heatsink,integrated Hfelectronic driver complete & compatible toT8/T12LED luminaire by disconnecting starter & ballast if necessary. |
| 472 | Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 473 | Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 474 | Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 475 | Supplying and erecting LED square / circular Max. 25 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuserhaving system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 476 | Supplying and erecting Concealed type foot/step light Max. 5W having IP67. IK10 rated Pressure die cast housing having system lumens output of Min. 500 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, SDCM<5, p.f. >0.95, operating range of 230-270V, surge protection of 2.5 kV, Life class of 25,000 Hrs. at L70B50, including driver by making necessary arrangement/recess in wall to make it flush with surface with 2 Year warranty. |
| 477 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. |
| 478 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF |
| 479 | Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. |
| 480 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 481 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 482 | Supplying, erecting & marking SPMCB 6A to 32A, D-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (NOTE-2) |
| 483 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 484 | Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 485 | Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MC |
| 486 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 487 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 488 | Supplying & erecting triple pole and neutral distribution board (TPNDB),SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness,surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 489 | Supplying & erecting triple pole and neutral distribution board (TPNDB),SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 490 | Supplying & erecting triple pole and neutral distribution board (TPNDB),SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 491 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 492 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 493 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 494 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 495 | Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specificationno. SW-SWR/MCCB |
| 496 | Supplying, fixing and commissioning 4 pole RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakageprotection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indications per specification no SW-RCCB/RCBO |
| 497 | Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 498 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 499 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 500 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 501 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 502 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specificationno. SW-SWR/MCB |
| 503 | Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specificationno. SW-SWR/MCB |
| 504 | Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 505 | Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 200A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 . |
| 506 | Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. |
| 507 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MSpipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 508 | Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard |
| 509 | Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB |
| 510 | Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs. |
| 511 | Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. |
| 512 | Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring &connections etc. |
| 513 | Supplying, installation & marking of surge arrestor/ surge protection device at the sub main distribution board after the incoming breaker of type 2 tested for Imax 40 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD |
| 514 | Supplying and erecting terminal spreaders suitable for 4 pole, up to 100A MCCB (Set of 8) |
| 515 | Supplying and erecting earth fault module for MCCB with adjustable earth fault sensitivity selection 10% to 50% of nominal current (In)and adjustable time delay 100/200 millisecond suitable for up to 200A MCCB with inbuilt CTs. |
| 516 | Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB. |
| 517 | Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 518 | Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 519 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 520 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 521 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 160 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 522 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI |
| 523 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. covercomplete with all materials, testing & recording the results as per specification no. EA-EP |
| 524 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 525 | Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. |
| 526 | Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete. |
| 527 | Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall with insulating and non-corrosive bond with required joints. As per specification no. EA-EP. |
| 528 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT |
| 529 | Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE |
| 530 | Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 531 | Supplying & erecting cast iron cable indicator plate buried along with route of cable for PVC / XLPE armoured cable as per specification No. CB-CIP |
| 532 | Supplying & erecting end pole D. P. Structure for 11/0.415 kV, 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100mm x 116 mm x 11 m Long withsuitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 400 Amps as incomer & 6 Nos.200 Amps Kitkat / MCCB for out going circuits.Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Beltetc.as per drawing (min. 124 Kg. iron work) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete. |
| 533 | Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50 ℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)ofLoad +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TRNSL. |
| 534 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI |
| 535 | Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessarycopperclampsfixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP. |
| 536 | Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. |
| 537 | Supplying,Insatallation,Comissioning & Testing of 58.5 Kva DG Set (CPCB IV+) C] Engine Electrical System Charging alternetur VDC/Amps 12V/35 A Starter motor rated voltage (DC) 12 Battery vertage (DC)/Capacity (AH) 12V/88 AHD] Fuel System Recommended fuel-6 1460, HSD Fuel tank capacity (205 (1) E] Fuel Consumption @load (LPH) (including radiator LPH 100% 11.7 LP75% 10.3Lubricating Of SystemLube oil sung capacity (7Lube oll change period (Hr500she of consumption of SFC)0.1%Lube all filter type/Qty-Spinen/01Recommended lube oil grade 15W40, A Recommended luite of GreavesMaxtherm 415 Frequency Did: 50 Current (3P) (Amps) 81.38 Type 4, rotating fizid Voltage regulator Automatic Voltage regulation 21%mulation class: H Temperature rise (Deg C) 125 Bearing (type), led Coupling Unbabenced load capability-20% of rated amps(H) Cooling System Rad) (-20 capability (Deg C50 Coolant capacity (Eng(2) Controller Controller Model (DEIF)SGC 120 M(1) DEF System Recommended fuel NA DEF Tank Capacity (NA DO DEFConsumption LPH100%NALPH 75% NAGerset Outer Dimensions Length x Width(W) x Height(H) (mm)-2500 x 1150 1560 Dry Weight (Approx) (kg)-2230 |
| 538 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 50 kVA up to 62.5 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.* |
| 539 | Making cement concrete foundation in 1:2:4 cement concrete with foundationbolts and nuts complete. (cost of wooden box is included) (for pumps). |
| 540 | Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS |
| 541 | Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, dulycharged with 24 months warranty complete. |
| 542 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL(FOR DG SET) |
| 543 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 185 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 544 | Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 545 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 546 | Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 547 | Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 Kv |
| 548 | Supplying & erecting FRP box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB |
| 549 | Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, havingsystem lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 550 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short-circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 551 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). |
| 552 | Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet,outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs.astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. |
| 553 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no.EA-EP |
| 554 | Supplying and erecting GI WIRE of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 555 | Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. |
| 556 | Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 500mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2. |
| 557 | Supplying and erecting LED Strip light 5m Length Max. 95 W IP20 class having minimum lumens output of 1600 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, p.f. >0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50 including driver with 1 year warranty. |
| 558 | Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No.FG ODF/FLS2. |
| 559 | Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast). |
| 560 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. Aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 561 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm.aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 562 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 563 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V,2 core 2.5 sq. mm. COPPER conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/CU |
| 564 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 565 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 566 | Point wiring for light/fan/bell in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification No: WG-PW/SW |
| 567 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 568 | Supplying & erecting mains with 1x1.5 sq.mm H.F.F.R. copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 569 | Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 570 | Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 571 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 572 | Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22 / E-27 base. |
| 573 | Supplying & erecting ready to use Retrofit T8 LED 18 / 20 tube light with polycarbonate body, heat sink, integrated HF electronic driver complete & compatible to T8 / T12 LED luminaire by disconnecting starter & ballast if necessary. |
| 574 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. (1 Bulkhaed in each lift shaft). |
| 575 | Supplying and erecting Exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specifcationno. FG-FN/EXF |
| 576 | Supplying, erecting & marking SPMCB 6A to 32A (B-series for Lighting) in provided distribution board as per specification No. SW-SWR/MCB |
| 577 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 578 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB (in each lift room 1 for 3-phase RCCB/ ELCB & 1 for 1-phase RCCB/ ELCB & 2 Nos. SP MCB) |
| 579 | Providing, erecting& commissioning RCCB ofelectromagnetictype with 30/100/300 mA sensitivity and having capacity of 63A. 4 polecompleteas per specification No. SW-RCCB/RCCB |
| 580 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 581 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU (form Generator to changeover switch) |
| 582 | Supplying and erecting Annealed bare copper wireof high purity of different sizesused forearthing onwall with necessarycopperclampsfixedon wall/cable/conduitwithscrews in an approved manner. |
| 583 | SITC of Electric Traction Passenger Lift with 1299498· Rated capacity :- 10 Passenger/680Kg· Floors :- G+1 floor (2 Stops/2 Landings)· Travel :- 3 to 4.2 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0mps VS· Car/Landing door clear opening of 800 mm wide x 2000 mm high· Clear Car size ofmm wide xmm deep x 2250mm high· Lift shaft available having clear size of .1900mm wide x .1900mm deep,.......... mm Pit depth, ………mm Overhead.· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift car Lift controller based on microprocessor/ PLC with VVVF Drive havingclosed loop control system, with IBMS compatible having necessary port. Thecontroller shall have necessary protections such as overcurrent, overvoltage, overspeed, overheat for all devices including lift motor and travel directionprotection, protection for phase loss at input or output etc. various operationmodes such as maintenance, change direction by attendant, full load bypass, VIPcall operation, self levelling operation, call cancel facility, auto return to homelanding, fireman evacuation operation, earthquake operation, door open/closeoperation from COP etc. The system can record information for minimum 30latest faults, with real-time clock management and handheld keypad with LCDscreen for view and setting of parameters. The control panel duly wired withproper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel havingenclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.interior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons withBraille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings. |
| 584 | Supplying, installing, testing and commissioning of 25 kWp ON-GRID Solar PVSystem / Plant consisting Solar PV Mono Crystalline Panel (580-620 Wp X 81 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate,canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB ,MCB etc. wiring up to solar Inverter in casing and capping, display board, signboard, two distinct earthing, lightning arrester, liaisoning charges, remotemonitoring system with maintaining card / chip for 5 years including net chargesfor RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract asper Specification no. ESD-RT-ONG. |
| 585 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 586 | Supplying and erecting AC three phase LT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3 x 240V, 50Hz, with backlit LCD display, optical port & RS 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. |
| 587 | Supplying and erecting static energy meter with 3 x 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh and MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power & with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company. |
| 588 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL(For 25 Kw Site) |
| 589 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 160 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 590 | Supplying and installation of Solar PV Module cleaning unit consisting of nozzles spray, necessary pipes, valves, post, electronic panel board concealed with weather proof cabinet, spreading water periodically for removal of dust, related motor pump, controller, timer and nozzles set suitable for covering 5 KW Solar PV Module. (Approx. 35 Sq. Mtr. PV Module area). |
| 591 | For item no. 4-8-8 for additional kW capacity, add Rs. 4000/- for every 5kW. |
| 592 | Supplying & erecting 2 pair telephone copper cable 0.5 mmdia.withhighdensitypolyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC,conformingto ITD specificationS/WS 113C laid in providedPVC casing capping/conduitas per specificationNo. WG-TW |
| 593 | Supplying,erecting & commissioningMDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specificationno. WG-TW |
| 594 | Supplying, installing, testing & commissioning digital (hybrid) type |
| 595 | Supplying,installing,testing&commissioning push buttontelephoneinstrumentdesk top/wallmountwith caller ID & Speaker unit as per specificationcomplete. |
| 596 | Supplying and erecting ISI marked modular type telephonesocketonegangwithsafetyshutter,duly erected on provided plate and box with wiring connections complete. |
| 597 | Supplying,installing,testing&commissioningpush button telephone instrument desk top unit as per specification complete |
| 598 | Supplying, installing, testing & commissioning IP telephone instrument as per specification complete. |
| 599 | Supplying, erecting & commissioning10 pairs FR junction box with moulded plastic enclosure as per specification no. WG- TW |
| 600 | Supplying &erecting 10pair,0.5mmdia,jellyfilled unarmouredtelephonecoppercablewithpoly-allaminate moisture barrier, laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 601 | Supplying,erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW |
| 602 | Supplyingand fixing tool-less IO (Ethernet) flush/surface typeinprovidedmodularboxasperspecificationno.WG- NAS/IO |
| 603 | Supplying, fixing, andconfiguring broadbandADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL |
| 604 | Supplyingand installingcat-6 armouredcable with ECCS tape suitablefor networkingas per specification No. WG- COC/NC |
| 605 | Supplying and erecting 25m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 606 | Supplying, erecting,Testing &Commissioningof 4MP IP Camera Dome with necessary accessories. ij Video Compression Ultra 265, H 265, MJPEG ii) Video Resolution Sub Stream 2MP (1920 x 1080) 30 fps Third stream D1 (720 x 576)30 lps iii) Frame Rate Main Stream 4MP (2592X 1520) Max 20 lps,4MP(2560x1440)Max25tps, 3MP(2048 x2520) . 25 fps, 1080P, Sub Stream 2MP (1920 x 1080) iv) Image Sensor Intrusion, crossing line, motion detection v)LensType1/3\",progressive scan4.0megapixel CMOS Vi) Lens 3.6mm @ F 2.0, Angle of view (H) : 72.0\" vii) Minimum Image SMARTBehavior Detection Intrusion,settings crossing line, motion detection, IntelligentIdentification Face detection, IP Address Filtering viii) Imagesettings RotateMode, Saturation, Brightness,Contrast,Sharpness adjustable by client software or web browser ix) Audio Two-way audio Supported STORAGE |
| 607 | Supplying, erecting,Testing&Commissioning 4MP IP Camera Bullet with necessary accessories.i)Video Compression,UItra265, H265, H264, MJPEG, ii) VideoResolutionSub Stream2MP(1920x 1080) Max 30 fpsThird stream D1 (720 x 576) 30 fps, iii) Frame Rate Main lps, 4MP (2560 x 1440) Max 25 tps,3MP(2048 x1520) Max. 25fps,1080P,Sub Stream2MP (1920 x 1080)25fps, iv) Image Sensor Intrusion, crossing line, motion detection,v)LensType 1/3\",progressivescan4.0megapixel CMOS, Vi) Lens 2.8 - 12mm @ F 1.4,vii)Minimum Image SMART Behavior Detection Intrusion,settings crossingline,motion detection,IntelligentIdentificationFacedetection,IP AddressFillering, viii)ImagesettingsRotateMode,Saturation, Brightness,Contrast, Sharpness adjustableby client software or web browser, ix) Audio Two-way audio Supported STORAGE EdgeStorageMicroSD,upto128GBNeMork Storage ANR, NAS (Network Attached Storage), x) Protocol NETWORKProtocolsIPv4, IGMP, ICMP,ARP, TCP, UDP, DHCP, PPPoE, RTP, RTSP,RTCP,DNS, DDNS,NTP, FTP, UPnP,HTTP, HTTPS, SMTP, 802.1 x, xi) Security IP Address Filtering, output, Access PoIicy,ARP Protection, RTSP Authentication,User Authentication, xii)OpratingWidetemperature range-40Cto60 C conditions( 40 F to 140 F), |
| 608 | Supplying, erecting. Testing & Commissioning Camera NVR32 Channel System Specifications 32ch with 4K Real -time Live Preview -Max 320Mbps incoming bandwidthwith H265 compression,Decoding supportupto4x4K @30, 8) (4MP@20ON VIF Version 2.4conformance VCA 8earcln and Smart Search for Playback Support 8 SAT AHDD up to sara, 2 USB, oJ 1 USB 3.0 |
| 609 | Supplyingand Installation,Testing & Commissioning of Surveillance InternalHDD( HardDiskDrive)HDD Supply, Installation, Testing&Commissioningof Surveillance Internal HDD Recording Capacity 8TB |
| 610 | Supplying,erecting,Commissioning& TestingScreen (108 Cm) /43 Inch SpecificationGeneral of Screen Size : 108 cm (43) Screen Type : LED HD Technology & Resolution : Full HD TV, 1920 x 1080 HDMI : 3, USB : 1Launch Year: 2018,ConnectivityFeatures: HDMI,2 Side : USB o 1Side Video FeaturesContrastRatio:Mega Contract(Static)Picture Engine:HyperrealView Angle: 178 DegreePanelType: A +, DigitalNoise Filter: YesLEDDisplayType:Direct,Aspect Ratio: 16:09,RefreshRate: o 60 Hz,Other Video Features o PMI300 Clarity, Color, Contract,Active Noise Reduction, Dynamic Color Enhancer o Picture Mode : 8Modes (Vivid, Standard, APS, Cinema, Cricket, Game, Expert 1, Expert 2 ) Picture : JPEG, Digital Noise Reduction,MoviesSupportin USB Mode,MPEG H 264 Decodero ResponceTme : 6.5 ms, Still Image, WideColorEnhancer(Plus), FilmMode,Cricket Mode Audio Features Number of Speakers : 2,Speaker Type : Down Firing with Bass Reflex ,Sound Technology : Dolby Digital PIus,SpeakerOutput RMS : 20 W Warranty ,Warranty Summary : 1 YearComprehensiveand Warranty,WarrantySummary: 1 Year Comprehensiveand 1 Year Additopnal on Panel. |
| 611 | Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 612 | Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification.No: WG-MA/CC. |
| 613 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG MA/CC. |
| 614 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification\ No. WG-MA/CC. |
| 615 | Supplying and installing cat-6 cable suitable for networking as per specification No: WG-COC/NC |
| 616 | Supplying and installing armoured single mode optical fibre cable 12 fiber, core dia 50/125μm. (OS1/OS2) 10/40 GBPS speed in provided underground HDPE pipe complete. |
| 617 | Supplying and fixing 1 meter length, UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 618 | Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG NAS/UTPC. |
| 619 | Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS |
| 620 | Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK |
| 621 | Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367mm) as per specification No. WG-NAS/RAK |
| 622 | Supplying and fixing 17U floor mount rack (Dimension-DxWxH – 800x600x954mm) as per specification No. WG-NAS/RAK |
| 623 | Supplying and fixing Power Distribution Unit for networking rack comprises of 6/16A (6 Nos. sockets), 25 A modular MCB, appropriate rating fuse andm indicator lamp, enclosed in black powder coated metal with necessary arrangement for fixing as per specification No. WG-NAS/RAK |
| 624 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 625 | Supplying, installation, testing and commissioning of main fire pump (MFP /EP) suitable for water discharge of 2280 to 2850 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 55kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF MFP/SSC/EP |
| 626 | Supplying, installation, testing and commissioning of jockey fire pump (JP)suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven byelectric motor 415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitablekW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP |
| 627 | Supplying, installation, testing and commissioning of main fire pump(MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at requiredworking speed suitable for manual/automatic operation and consisting offollowing :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical sealconforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for autostop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP |
| 628 | Supplying, erecting, testing & commissioning of fire pump control panel (FCP)of cubical construction, floor mounted type, fabricated from minimum 2 mmthick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specificationsthe capacity of electric motor driven pump are as followsa. Main fire pump(MFP) having capacity of 22kW 1no (1 working)b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby,alternate run per start in auto mode) comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU\"s, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitablerating.Each 1823204. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch.5. TPN SPD 100kA Type 1 +2 tested.6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps.7. System controller to control operation of main electric fire pump, jockey(pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays, timers. sensors, annunciation window for fault indication, complete as per specification. 8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications.9. Siren of required capacity to be activated when main pump starts & alliedaccessories as per requirements of local CFO or as directed by engineer in charge.10. Danger board as per IS. 11. Spare HRC fuses minimum 2nos of each individual rating with requiredbakelite fuse holder for main & jockey fire pumps MFP=(1working), JP =(1working+1standby, alternate run per start in auto mode) complete panel, as per specification no. FF-MFP/ECP |
| 629 | For main electric motor driven fire hydrant system pump of 55kW capacity & relevant capacity jockey pump add Rs… |
| 630 | For addition of standby main diesel engine driven fire pump (1 standby), add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessories, indicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode) & jockey fire pumps (1working+1standby, alternate run per start in auto mode) , add Rs....... The control for diesel engine comprises of automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low Lub. oil pressure, high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumps. |
| 631 | Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP |
| 632 | Supplying and erecting G.I. pipe ‘C’ class ERW 32 mm dia with necessary fittings complete as per specification no. FF-PP |
| 633 | Supplying and erecting G.I. pipe ‘C’ class ERW 40 mm dia with necessary fittings complete as per specification no. FF-PP |
| 634 | Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP |
| 635 | Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP |
| 636 | Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessaryfittings complete as per specification no. FF-PP |
| 637 | Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP |
| 638 | Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP |
| 639 | Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP |
| 640 | Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system. |
| 641 | Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system. |
| 642 | Supplying and erecting 80 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV |
| 643 | Supplying and erecting 100 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV |
| 644 | Supplying and erecting 150 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV |
| 645 | Supplying and erecting 80 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (openarea Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 646 | Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (openarea Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 647 | Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 648 | Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 649 | Supplying and erecting 65 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 650 | Supplying and erecting75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 651 | Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 652 | Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 653 | Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 654 | Supplying and erecting75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 655 | Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 656 | Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 657 | Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 658 | Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 659 | Supplying and installing one piece moulded HDPE / fibre water tank for negative suction only, having capacity 1000 litres fitted with necessary accessories complete as per specification no. FF-FFA/PT |
| 660 | Supplying and installing wall mounting swinging hose reel drum fitted with 19mm dia. 30m long high pressure polypropylene (Polyhose) along with necessaryaccessories complete as per specification no. FF-FFA/HV |
| 661 | Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specificationno. FF-FFA/RRL |
| 662 | Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/NZ |
| 663 | Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC |
| 664 | Supplying and erecting 20/25mm dia gun metal air release cock, withnecessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV |
| 665 | Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG |
| 666 | Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS |
| 667 | Supplying and erecting brass orifice plate having 6 mm. thickness, 160 mm outer dia with required diameter of inner hole at every double outlet hydrantvalve as per specification no. FF-FFA/OP |
| 668 | Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8\" x 6\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 669 | Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FFAFAS/SD . |
| 670 | Supplying, installing, testing and commissioning of intelligent addressable thermal/ heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from - 20°C to 38 °C for fixed-heat and rate-of-rise type detectors whereas 0°C to 90°C for high heat type detectors, in built isolation mode, suitable for industrial/ kitchen/ boiler room etc. with 3 years equipment replacement warranty, IS : 2175-1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD. |
| 671 | Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \"Break Glass\" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP. |
| 672 | Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH. |
| 673 | Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU |
| 674 | Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM |
| 675 | Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM |
| 676 | Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 2 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP. |
| 677 | Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR |
| 678 | Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC |
| 679 | Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC |
| 680 | Supplying, erecting, testing and commissioning rust free microphone floor stand of chrome plating/powder coating or S.S. material , 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete. |
| 681 | Supplying, erecting, testing and commissioning of 1.0 sq. mm speaker wire complete. |
| 682 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 683 | Carrying out core cutting of size 3\" to 5\" dia x 15\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. |
| 684 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 685 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 50 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL |
| 686 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL |
| 687 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 688 | Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware. |
| 689 | Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15mm (½\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FFSPR. |
| 690 | Supplying, erecting, testing and commissioning vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3)Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts forsecure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes. |
| 691 | Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. |
| 692 | Supplying, erecting, testing and commissioning of sprinkler flexible pipe of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Brust) with brand line (Inlet) 25 mm NPT male thread to sprinkler head (outlet) 15 mm NPT female thread with reducer, nipple, 2 side brackets center bracker stocbar of 1500 mm size (UL Listed) cmplete as required as per specification no FF-SPR/FHP(Rates taken from Estimate No.523/GND/2023-24T.S.NO.312/2023-24 Itesm No.09) |
| 693 | Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.(Reference taken from - Chandrapur ZP PHC Estimate, TS No. 82/2024 Dated 08/01/02024 |
| 694 | Supply, Installation of Emergency Autoglow Fire Exit Sinages (Rates taken from Estimate No.02/EE/YTL/2023-24, Sr. No.37) |
| 695 | Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. APWCR/WC |
| 696 | Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system. |
| 697 | Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 698 | Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply up to 7.5 H.P. |
| 699 | Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 5.625 KW/7.5 HP with 415 V 50 c/s. A.C. supply, having delivery head from 57 to 22 m and discharge from 120 to 900 litres. . per minute & pipe of Suction 75 mm/Delivery 65 mm diameter erected with necessary H type clamps as per specification No. WP-OSP |
| 700 | Supplying & erecting Water level controller 230/415 V, A.C. , Two way underground tank operation only. |
| 701 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBat position as per specification no. APAC/ WAC |
| 702 | Supplying, laying / fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 15.8 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 703 | Supplying, laying / fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 704 | Supplying, erecting& terminatingXLPE armoured cable 2 core2.5sq. mm. copper conductorcontinuous 5.48 sq. mm. (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 705 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 706 | Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45°. |
| 707 | Supply, fabrication, installation and testing of flexible canvas connections constructed between ductable unit/dampers/ducting of suitable size with fire resist flexible double canvas sleeve complete. |
| 708 | Supplying and installing of collar damper of galvanised iron material of upto 120 microns for anti corrosive resistance for supply air grill of suitable size. |
| 709 | Carrying out core cutting of size 3\" to 5\" dia x 15\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. |
| 710 | Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance |
| 711 | Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance |
| 712 | Supplying and erecting of Keruilai make cooling unit/breez air make cooling unit air flow rate-18000 cmh /water consumption-30-40 l/h weight-75 kg size 110cmx110cmx110cm with pre filtter & munters make celldek ped including ducting, Aluminium grill, fabrication, lifting, shifting, freight, labour charges etc. complete. |