Tender For Provision Of Otm Accommodation For 110 Or For Inf Bn At Gaucher (Using Peb Technology) Under Ge 871 Ews.; 1 Sch A Part-I (BUILDING WORK), To be quoted by contractor 2 Design, fabricate, supply, errect, construction and execution of OTM Accn (G+2) for 01 Hav & 10 OR including sanitary block on ground and first floor by using PEB structure technology based on given tentative line plan including seperate steel water staging complete all as specified and as directed.Remarks:-(a) Cost of steel water staging for 10x1000 ltr tank including monkey caging shall be deemed to be included in quoted rate of building. 3 Design, fabricate, supply, errect, construction and execution of OTM Accn (G+2) for 06 Hav & 15 OR by using PEB structure technology based on given tentative line plan complete all as specified and as directed. 4 Design, fabricate, supply, errect, construction and execution of OTM Accn (G+2) for 15 ORs by usingPEB structure technology based on given tentative line plan complete all as specified and as directed. 5 Design, fabricate, supply, errect, construction and execution of (single story) for common room, store and study room by using PEB structure technology based on given tentative line plan complete all as specified and as directed. 6 Total amount of sch A Part - II (SITE CLEARANCE AND DEVELOPMENT WORK) 7 Total amount of sch A Part - III (PROTECTIVE WORK) 8 Total amount of sch A Part - IV (PCC HARDSTANDING) 9 Total amount of sch A Part - V (SEWAGE DISPOSAL) 10 Total amount of sch A Part - VI (AREA DRAINAGE) 11 Total amount of sch A Part - VII A (DEMOLISHION OF BUILDING) 12 Sch A Part-VII B (DEMOLISHION OF BUILDING) 13 Taking down/ dismantaling of distribution board including removal of MCBs SP/SPN/TPN complete all as specified and as directed. 14 Taking down XLPE/PVC cable from panel to building complete of size 10 sqmm 2 core, complete all as specified and as directed. 15 Total amount of sch A Part - VIII A (EXTERNAL ELECTRIC SUPPLY) 16 Sch A Part-VIII B (EXTERNAL ELECTRIC SUPPLY) 17 Supply and fix street light fitting 45 watts 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and directed 18 Supply, install, testing and commissioning of LT weather proof feeder pillar panel (450mm x 450mm x 15mm) board outdoor type powder coated hinged door shutter made of 3.15mm CRCA sheet outer with angle iron 50 x 50 x 6mm, floor mounted type with closed bus bar chamber and with aluminium bus bar 100 Amp with insulator suitable for 3 phase, 4 wire 50 Hz ACcomplete all as specified and directed. 19 Supply and fix FRP junction box size 300x200x105 mm having 4 Nos aluminium busbar of size 25x4mm fixed on epoxy insulator with MCB SP 6 Amps front openable hinged cover outdoor type weather proof suitable for mounting on pole including fixing MS clamp 02 Nos with nuts, bolts and washers complete all as specified and directed. 20 Supply and fix bracket made out of GI tubing single piece (not wleded) bended at proper angle of size 40mm dia, light grade 1.5 mtr long including painting with aluminium paint over one coat of red oxide primer to the bracket etc complete.including 1.0sqmm 3.0 core flexible Copper cablein PVC conduit with clamp from juction box to connecter of street light fitting complete all as specified and directed. 21 M & L for laying DWC (Double Wall Corrugated) pipe conforming to IS 16098 of nominal outer dia 50mm and inner dia 38mm for laying electric cables (as per IS 16205 : electric cable use) under trenches/ under road/ wall complete all as specified and directed. 22 M & L for laying DWC (Double Wall Corrugated) pipe conforming to IS 16098 of nominal outer dia 90mm and inner dia 75mm for laying electric cables (as per IS 16205 : electric cable use) under trenches/ under road/ wall complete all as specified and directed. 23 M & L for laying DWC (Double Wall Corrugated) pipe conforming to IS 16098 of nominal outer dia 110mm and inner dia 95mm for laying electric cables (as per IS 16205 : electric cable use) under trenches/ under road/ wall complete all as specified and directed. 24 Design, Supply,install,testing and commissioning of LT weather proof Panel board (1200mm x 1200mm x 500mm) CPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having closed bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 400 Amps rating mounted on porcelain insulators, having indicator lamp RYB, selector switches and internal wiring. The panels shall be factorymade, double door, made out of 3.15 mm thick CRCA sheettotally enclosed dust, vermin and rust prooffront operated conforming to IS 8623, front and rear opening with locking arrangement fixed with MSangle iron frame of size 50X50X5 mm duly embedded in PCC foundation height not less than 0.60 mtr above ground level and 0.30 mtr below ground level. Totally type tested panel as per the latest standard IEC 61439 complete all as directed including internal wiring with multistranded copper conductor cable of suitable sizeincludinglugs and cable gland to incoming and outgoing cable. The panel should have bus bar clearance of 25mm for ph to ph and 19mm for ph to neutral. Zero stray voltage doors and panels, polyster glass support for insulation. The cable alleys should be 300mm wide and it should be fitted with hinged door that open up to and angle of 95 deg. The provision of cable entry should be from bottom. The IP protection of panel should be IP-42 for external and IP2X for internal with 3B as form of sepration. Panel should be suitable for sesimic zone V. The panel should be equiped with suitable size of CT and display meter for VAF measurement all as directed at site and comprising of the following:(a) Aluminium bus bar capacity 300 Amp for Ph. RYB - 3 Nos & Neutral - 4 Nos(b) MCCB 4 pole 250 Amps 36 kA - 01 Nos (Incoming) (c) MCCB 4 pole 160 Amps 16 kA - 02 Nos (Outgoing)(d) Digital Ammeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No. and suitable CT ratio 0-200 Amps (e) Digital Voltmeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No. 0-500 V (f) Complete control panel wiring with stranded copper conductor of suitable size along with one set indicator lamp for RYB for each incoming and outgoing feeder 25 Design, Supply,install,testing and commissioning of LT weather proof Panel board (1200mm x 1200mm x 500mm) CPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having closed bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators, having indicator lamp RYB, selector switches and internal wiring. The panels shall be factorymade, double door, made out of 3.15 mm thick CRCA sheettotally enclosed dust, vermin and rust prooffront operated conforming to IS 8623, front and rear opening with locking arrangement fixed with MSangle iron frame of size 50X50X5 mm duly embedded in PCC foundation height not less than 0.60 mtr above ground level and 0.30 mtr below ground level complete all as directed including internal wiring with multistranded copper conductor cable of suitable sizeincludinglugs and cable gland to incoming and outgoing cable. The panel should have bus bar clearance of 25mm for ph to ph and 19mm for ph to neutral. Zero stray voltage doors and panels, polyster glass support for insulation. The cable alleys should be 300mm wide and it should be fitted with hinged door that open up to and angle of 95 deg. The provision of cable entry should be from bottom. The IP protection of panel should be IP-42 for external and IP2X for internal with 3B as form of sepration. Panel should be suitable for sesimic zone V. The panel should be equiped with suitable size of CT and display meter for VAF measurement all as directed at site and comprising of the following:(a) Aluminium bus bar capacity 200 Amp for Ph. RYB - 3 Nos & Neutral - 4 Nos(b) MCCB 4 pole 160 Amps 36 kA - 01 Nos (Incoming) (c) MCCB 4 pole 63 Amps 16 kA - 01 Nos (Outgoing)(d) MCB DP 32 Amps 10 kA - 04Nos (Outgoing) (e) Digital Ammeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No. and suitable CT ratio 0-200 Amps (f) Digital Voltmeter flush pattern type square dial 96 x 96 mm alongwith selector switch - 01 No. 0-500 V (g) Complete control panel wiring with stranded copper conductor of suitable size along with one set indicator lamp for RYB for each incoming and outgoing feeder 26 Total amount of sch A Part - IX A (EXTERNAL WATER SUPPLY) 27 Sch A Part-IX B (EXTERNAL WATER SUPPLY) 28 M & L for cutting existing steel tubing in position without taking down for branch connection from pipe of size 50mm dia including necessary union, socket and nipple/ Tee as required for taking branch connection complete all as specified and directed. 29 S & F open well submersible pumpset 3 HP capacity at rated voltage, 50 Hz, head of 33 mtrs, three phase AC power supply, insulation-B class, protection IP68, voltage range 400 to 440 V AC, pump with suitable stage, including 3 core 4sqmm copper flat cable from starter to pump complete all as specified and directed. 30 S & F DOL starter, 3 phase, 415V AC 4HP (2.98 KW) (HSN code 8536), coil voltage 400-440 V AC, 50 Hz with Amp relay range 4-6.5 A including single phase preventer, over load protection, timer etc. suitable for 3 HP submercible pump set complete all as specified and directed.Make: L&T (LK)/ Polycab/ Havells/ Crompton/ Schneider 31 Total amount of sch A Part - X (INTERNAL WATER SUPPLY) 32 Total amount of sch A Part - XI A (INTERNAL ELECTRIC SUPPLY) 33 Sch A Part - XI B (INTERNAL ELECTRIC SUPPLY) 34 Supply and fix street light bracket made out of GI tubing single piece (not wleded) bended at proper angle of size 25mm dia, light grade 1.5 mtr long including painting with aluminium paint over one coat of red oxide primer to the bracket etc complete including MS clamp, nut and bolt with cup washer complete all as specified and directed. 35 Sch A Part - XII (HOT WATER SUPPLY) 36 Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 35 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, PVC connection pipe hot and cold etc. complete all as specified and directed