| 1 | Dismantling plain or corrugated steel sheeting any gauge, thickness |
| 2 | S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified. |
| 3 | S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified. |
| 4 | S&F Fibre glass reinforced translucent corrugated sheet 2 mm thickwith two corrugations side lap fixed with coach screw and washer in roof, wall etcfixed with L or J hooks complete all as specified and as directed |
| 5 | S&F Plain, black, mild steel sheeting 1.25 mm thick , in ridges,hips, valley gutters,drip and straight flashings length and girth as fixed complete all as specified and as directed |
| 6 | Demolition ofbrick work or stone masonry built in cement mortar incl all quoins arches pillars etc. |
| 7 | M&L Brick Work with Sub-Class ‘B’ Bricks (with modular size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:4, complete all as specified and as directed. |
| 8 | Demolition of Reinforced cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 9 | M&L for Pre-cast RCC 1:2:4 type B1 using 20mm graded stone aggregate as in landing, cover slabs, lintel(for manhole covers, drains etc) set in CM 1:6 complete all as specified. Note:TMT bar will be measured seperatly. |
| 10 | M&L for TMT reinforcement 10 mm dia and over cut to length bent to shape including cranking, hooking etc binding with mild steel wire not less than 0.90 mm dia (annealed) all as directed complete. |
| 11 | Dismantling floor, hearth or wall tiling incuilding cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the permises. |
| 12 | M&LNon - skidcoloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including Screed bed or bedding layer of cement mortar 1:6, 15 mm thick for laying floor finishes. |
| 13 | M&LNon - skidcoloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including Screed bed or bedding layer of cement mortar 1:6, 15 mm thick for laying floor finishes. |
| 14 | M&L for Glazed ceramic coloured tiles in vertical surfaces 450x 350x 7 mm thick set and jointed in neat cement slurry & painted in white or colour cement to match incl sreed bed 10 mm thick in CM 1:4 . |
| 15 | M&L for 20mm thick plaster in two layers on fair faces of brick work or concrete surface in cm (1:4) with wpc @2% by weight of cement face of conc work to wall surface and the surface is finished even and smooth without using extra cement.WPC paid separetely |
| 16 | M&L rendering 15mm thick on other than fair faces of brick or concrete Surfaces in cement mortar 1:6 finished even and smooth. |
| 17 | Demolition of cement Concrete in ground floors and pavingsn exc 15 cm thickness (below or above ground level) |
| 18 | M&L for 75 mm thickPCC 1:3:6 type C2 using 40mm graded aggregate as in plinth course/sub base as directed by engineer in charge. |
| 19 | M&L cement concrete with PCC type D2 1:4:8 using 40mm graded aggregate as in foundation and mass concrete. |
| 20 | S & F in repair 110 mm bore PVC (SWR) Soil, waste and vent pipes double socketed in any length with rubber ring joints fixed in walls. |
| 21 | S & F 110 mm bore PVC (SWR) bends of any radius. |
| 22 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing or removal to store |
| 23 | Taking up or down 20 mm bore steel tubing and connections, including cleaning for Refixing or removal to store |
| 24 | S&F 15mm bore GI tubing medium graded with all fitting and fixed complete to wall and ceiling or laid in floor . |
| 25 | S&F 20mm bore GI tubing medium graded with all fitting and fixed complete to wall and ceiling or laid in floor . |
| 26 | S&F in repairs15 mm bore chromium platedBib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed |
| 27 | S&F in repairs15 mm bore, chromium plated fancy type, Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed |
| 28 | S&F in repairsBrass chromium platedTubular towel rail, 20mm dia, D type, 60cm long between flanges |
| 29 | S&F in repairsBrass chromium plated shower rose 125mm size |
| 30 | S&F in repairs 600x450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromimum plated brass screws and cup washers. |
| 31 | S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long |
| 32 | Dismantling water tanks and removing to store exc 500 & not exc 1000 ltrs |
| 33 | S&F 500 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed. |
| 34 | Dismantlinig wrought iron or mild steel work of any description not otherwise proveded for. |
| 35 | S&F roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam tee, angle, channel or flat sections) including clits etc conforming to Fe-410-0 W Gde- E- 250, Quality -A. |
| 36 | S&F Rolled sections as in framing for cladding, glazing and thelike fixed with angle cleats and connecting plates, etc.conforming to Fe-410-0 W Gde- E- 250, Quality -A. |
| 37 | Taking down Chowkats or frames not exceeding 1.5 Sqm each (Without taking off shutters from the frames) |
| 38 | Taking down Chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (Without taking off shutters from the frame) |
| 39 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets. |
| 40 | S&F for Anodised aluminium/ GI snap grid power coated framed work of size main runner 39x24.70x0.80 mm, cross tee size 29.x24.70x0.80 mm, wall angle 22.2x22.2x0.65 mm and size of grid 605x605 mmfor false ceiling all as specified with 4mm thick GI suspender complete all as specified and as directed. |
| 41 | M & L for 4mm thick Non Asbestos designed Cement E board incl two coats of distempering in one side as approved by GE of size fixedin ceiling as specified and directed. |
| 42 | S&F anodised aluminium frame for doors, windows, ventilators, partitions with one or more rebates including joining cleat for fixing etc complete all as specified incl powder coating above aluminium section.(minimum thickness of powder coating 50 micron). |
| 43 | S&F anodised aluminium door shutters aluminium section weighing 0.55 kg/m including necessary joining cleats glazing clips rubber neoprene packing anodised aluminium snap beading screws, locking arrangements, hinges, suitable handle etc complete all as specified powder coating of any colour(thickness of powder coating not less than 50 micron. |
| 44 | S&F for anodised window shutters, side hung type without sash bars aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips,ruber neoprene packing,anodised aluminium snap beading screws,anodised aluminium fittings such as peg stays 150 mm long(1 no),hinges type-B-21 100 mm long( 2 no) suitable handle 1 no complete all as specified incl power coating of any colour (thickness of powder coating not less than 50 micron). |
| 45 | S & F 4 mm thick Sheet glass, ordinary quality and glazing with wooden beadsin squares not exceeding 0.5 Sq. M in each pane |
| 46 | S & F 5.5 mm thick Sheet glass, ordinary quality and glazing with wooden beadsin squaresexceeding 0.50 Sqm in each pane |
| 47 | M&Lfor 12 mm thick pre laminated particle board, interior grade prelaminated one side with decorative choice lamination &other side balancing white lamination fixed in screws to timber frame work. |
| 48 | Supply and fixedaluminium wire cloth with 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium stapple complete all as specified and directed. |
| 49 | S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet rainforced with MS square tube in opening as per specification & as directed. |
| 50 | S&F forfactory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. .frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail,; Paneling of plain colour PVC sheet to be fitted in the M.S.frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification complete all as specified and as directed. |
| 51 | S&F aluminium alloy 250mm anodised sliding door bolts with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast - aluminium alloy. |
| 52 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section |
| 53 | S&F 100mm MS butt hinges medium weight |
| 54 | S&F aluminium handle cast type anodised 150mm size |
| 55 | S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) |
| 56 | Surface Preparation: Surface Preparation by removing existing flooring with mechanical means, prepare the concrete substrate with properscarifying & diamond grinding, Shot blasting, with Vaccum cleaning to remove dirt, dust, laitance, other contaminants etc., and to form the required anchor profile on the floor substrate between the floor topping and the concrete floor |
| 57 | Floor Leveling (3mm thick):Providing and applying 2 part water dispersed epoxy resin primer Sikafloor ®-80 Epocem Primer or equivalent make like Fosroc/BASF/STP etc. followed by applying temporary moisturer barrier technology based three part, self smoothing underlay screed Sikafloor 81 Epocem or equivalent make like Fosroc/BASF/STP etc. to a thickness of 2mmhaving carbon dioxide diffusion coefficient 1782 as per Klopfer Engel fried method, Water vapour diffusion co-efficient µH2O = 177 as per DIN 52615, Water absorption co-efficientW = 0.06 kg/m2as per SN EN 1062-3,Compressive strength 55 N/ Sqmm after 28days as per ASTM C 579,Flexural strength 10 N/ Sqmm after 28days as per EN 196, When applied at minimum 3 mm thickness it can be laid over high moisture content substrate when substrate moisture is more than 4%. |
| 58 | Installation of Epoxy topping 2mm using notch trowels and Spike rollers Providing and applying 2mm thick two part, solvent free, coloured,100% solids, self smoothing, smooth glossy, epoxy resin topping Sikafloor®-264 HC or equivalent make like Fosroc/BASF/STP etc. using notch trowels and spike rollers having compressive strength of 53 N/mm2 as per EN 196-1, Flexural strength of 20N/mm2 as per 196-1, Shore D Hardness 76 As per DIN 53 505, abrasion resistance 41mg ( CS10/ 1000/ 1000) as per DIN 53109. All in complete as per the manufacturers specifications and directions of the engineer in charge. |
| 59 | Crack Treatment : Inspecting the surface for any cracks. Cracks if any have to be sealed with epoxy repair mortar after clean or removal of cover concrete and making \"V\" groove of 20mm wide and 10mm deep cover crack line along the length of the crack by elctrically operated angle grinder with diamond concrete saw blade and cleaning it by air blower as directed by Engineer-in-Charge. |
| 60 | Sealing of exposed \"V\" groove of 20mm wide and 10mm deep with Sikadur 31 or equivalent make like Fosroc/BASF/STP etc. solvent-free, moisture tolerant, thixotropic, structural adhesive and repair mortar, based on epoxy resins and special fillers, designed for use at temperatures between +10°C and +40 °C. Product should conforms to ASTM C 881-78, Type I, Grade 3, Class B+C : compressive strength > 60 N/mm2 (14 days) according to ASTM C881 : bond strength < 10 N/mm2 (7 days) according to ASTM C882 . |
| 61 | S&F in repair nylon HDPE bird proofing net of 2.5 x 2.5 cm of 1 mm thickness fixed with polypropelene rope of 6 mm dia for net and 12 mm dia for boarder with nail clips, cable zip ties & C hooks as directed by engr-in charge. Note : Rate quoted by the contractor shall deemed to inclusive of necessary scaffolding and all other fittings and binding materials as required for fixing the net complete all as directed. |
| 62 | Supply and fix for Turbo Ventilators Industrial/domestic turbo ventilator as per Manufactureres Insturction :-(i)(Turbine Dia 28 Inch (760mm), (Nech/Throat-24\"), (Height-18\"/610mm) (Vanes(Blades) - 42 Vanes, Aluminium 0.50mm Alloy 8011), Base Ring MOC(Mounting ring - Stainless steel),(Top plate MOC- Stainless steel 0.80 mm thickness).(ii) Rotation - Twin sealed 6203ZZ bearing with self lubricating duponty zytel 101L Polyamide 66 resin to ensure frictionless rotation even at lowest wind velocity Twin sealed 6201ZZ bearings with self lubricating Duponty Zytel 101L Polyamide 66 resin to ensure frictionless rotation even at lowest wind velocity.(iii) (Centre shaft : 18mm high carbon steel zinc plated) ( Inner Arms - M.S. with electro zinc plating), (Outer Arms - M.S. with electro zinc plating), (Frp base plate - 2mm thick clear 1.020 mtr wide 1.65 mtr long matching your sheet profile weight 8Kg Approx), (Centre width - 800mm+/-5mm), (Dia of Bottom Ring- 600mm+/-15mm), (Nos of Bearings -02 Nos), (Bearing Type : skf-6001ZZ & 6003ZZ) (Rivets-Aluminium Alloy wiht Washer) ,angle adjustable range- 0 to 17 deg,Exhaust capacity- 1972 - 2164 CFM, Wind velocity 8 Km/Hr, Make:- Tubro Ventilator India (Industrial Ventilating Solutions) or Equivalent as approved by GE complete all as specified and as directed. |
| 63 | Preparation of newsteel surfaces of any description, over 10 cm width or girth, not otherwise described applying twocoat of synthetic enamel paintover a coat of red oxide zinc chrome primer complete all as directed. |
| 64 | M&L for preparation of new plastered surfaces of walls and applying two coats of acrylic distemper including one coat ofchalk whiting on plastered surface to prepara-tory to distempering complete all as specified and directed over 1 mm thick wall care putty. |
| 65 | M&L for preparation of new surface of wall and applying two coats ofcement base paint over a coat of primer. |
| 66 | Preparation of old paintedsteel surfaces of any description, over 10 cm width or girth, not otherwise described applying twocoat of synthetic enamel paint complete all as directed. |
| 67 | Preparation of old paintedsteel surfaces of any description, over 10 cm width or girth, not otherwise described appling onecoat of synthetic enamel paint. |
| 68 | M&L two coats of Aliphatic two component paint suitable for marking on concrete and plaster surfaces, especially in exterior application incl preparation of surfaces and as per manufacturer instruction complete all as specified and directed.Make - STP or equivalent. |
| 69 | Supply and fixin repair MS wheels of any sizefor hanger doors incl greasing completeall as specified and directed |
| 70 | Demolition of cement Concrete of any description and in any position not otherwise specifically provided forcomplete all as specified and directed. |
| 71 | M&L for 100 mm thick cement concrete type B-2 (1:2:4) using 20 mm graded stone aggregate as in path/hardstanding/sub base complete all as specified. |
| 72 | Demolition of stone slabs tiles of any description or thickness in floors apronslaid bedded and pointed in any morter etc |
| 73 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete. |
| 74 | Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified. |
| 75 | Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified. |
| 76 | Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit includingremovalof batten/ conduit/ gutties/ wooden boards/ switches/ sockets/ regulators/ light fittings etc and seperating the serviceable items like fan regulators and light fittings for re-use under respective items and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified. |
| 77 | M&L Point Wiring with 1.5 Sqmm Copper Conductor single core PVC insulated Flame Retardant Low Smoke (FRLSH) Unsheathed 1100 Volt grade multi-stranded Cable drawn through and including stove enamelled steel conduit medium grade of suitable size and its Accessories as required at Site, fixing on surface of Wall, Roof, mounted onPVC Pressed Terminal Box of suitable sizewithTop Cover for mounting Switches, Sockets, etc. including PVC insulated and unsheathed Single Core multi-stranded Copper Conductor Cable of size 1.5 Sqmm (FRLSH) Green in Colour as Earth Continuity Conductor connected to Common Earth and Earth dolly for One Light/Fan/BellPoint controlled by One 1-Way Switch 5 Amp, duly fixed with copper lugsand flexible pipe from ceiling rose to fitting/fixtures complete all as specified and as directed. |
| 78 | Description all as per item No 77here in before but for one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 79 | Description all as per item No 77here in before but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board . |
| 80 | Description all as per item No 77here in before butusing 2.5 sq mm single core copper conductor cable of multistranded flame retardant Low smoke (FRLSH) PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point incl running of2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 81 | S & F in replacementswitch piano(white)single pole flush type 5 amps, 230 volts.complete all as specified and directed. |
| 82 | S & F in replacement socket(white)flush type multipurpose 3/5 pin 5 amps 2 in 1, 230 Volts all as specified. |
| 83 | S & F in replacement switch socket combination (white)flush type multipurpose 3/5 pin 5 amps 2 in 1230 Volts complete all as specified and directed. |
| 84 | S & F in replacement switch socket combination(white) 2 in 1 multipurpose 3/5 pin 5/15 amps flush type complete all as specified and directed. |
| 85 | S & F in replacement ceiling rose(white) three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and directed. |
| 86 | S & F sheet metal enclosure MCB DBTPN 4 way with 200 amps rated bus bar 415 volts double door with magnetic locking system complete including removal of old unsv sheet metal enclosure all as specified |
| 87 | S & F MCB TPN 415 volts suitable for fixing in MCB DB of capacity 63 amps \"B\" curve complete all as specified and directed. |
| 88 | S & F MCB SP 6 to 32 Amps C-Series 240 volts for fixing on MCB DB\"sall as specified. |
| 89 | M & L for sub main wiringwith 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 sqmm alongwith one run of FRLSH PVC insulated & unsheathed copper conductor of nominal cross sectional area 2.5 sqmm as earth continuity conductor drawn through & including stove enamelled steel conduit of suitable size in concealed connected to DB or Main Boardduly fixed copper lugs of suitable size as per site requirement complete all as specified and directed. |
| 90 | M & L for sub main wiringwith 4 runs of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10sqmm alongwith one run of FRLSH PVC insulated & unsheathed copper conductor of nominal cross sectional area 10sqmm as earth continuity conductor drawn through & including stove enamelled steel conduitof suitable size in concealed connected to DB or Main Board duly fixed copper lugs of suitable size as per site requirement complete all as specified and directed. |
| 91 | S & F in repairs Flame proofEnergy saving newNext generation, energy saving, environment friendly & robust highbay LED with PDC housing suitable for ceiling (Surface/Suspended) mounting with system efficacy not less than 150 lm/W, 6500K Cool day light ,with toughened glass highbay light fitting luminaire with high power LEDs as light source and PC Cover having TOP opening seperate driver compartment with IP 66 Protection and impact resistance of IK07 with electronic driver of capacity 150 watts with pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 2.5 Sqmm 3 coreceiling rose to fitting and iron bracket made out of Angle iron bend to required shape to be fittedcomplete all as directed by Engineer-in-Charge. |
| 92 | S & F in replacementFlame Proof Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 Flood light fitting luminaire, with system efficiency ≥110 lumen/W,AC120-300 V with high power LEDs as light source and Secondary lenses 10KV SPD included with high efficiciency electronic driver of capacity 120 watts, with pre wired andnecessary mounting arrangement and provision of 4.00 sq mm three core flexable copper conductor cable multi stranded ,connected to existing points in Hanger beam angle of any description complete all as directed by Engineer- in-charge. |
| 93 | S&F in replacementLEDs aviation light 4 WattIP65energy saving new generation environmental friendly long life versatile presure die cast aluminium housing with polycarbonate enclosure with pre wired andnecessary mounting arrangements,includingprovision of new 3 core multistrandedcopper conductor of size 23/0.193, complete all as specified and as directed. |
| 94 | M/L in replacementfor Joists of Motor, bracings, supports, clamps, straps D-clamps, back plates and MS frames fabricated from structural steel sections such as MS channel, angle iron and flats of suitable size etc including nuts, ,bolts, washers eye hooks, welding, bending cold or hot drilling holes for bolts in any shape or size including two coats of synthetic aluminium paint over a coat of red oxide primer after preparation of steel surface complete all as specified and directed. |
| 95 | S & F in replacementMCCB 4 Pole 200 Amps, thermal magnetic type DN2-250D with breaking capacity 36 KA with thermal magnetic release at 415 volts,including spreader terminal complete all as specified and directed. |
| 96 | S & F in replacement sheet metal enclosure MCBVTPN 8 wayDouble door Ready to use DBs - Provided with insulated vertical phase bus-bars |neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement spill protector | color-coded interconnecting wire set | cable ties | blanking plates and circuit identification labels With provision for4 Pole MCCB 200 A as incomer and SP/SPN MCBs as outgoing complete all as specified and directed. |
| 97 | Taking down the existing unservicable UG cable of any type/ description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified. |
| 98 | Supply & laying incl replacement of LT UG XLPE sheathed PVC insulated, screened PVC bedded, Galvanised Steel Strip of Wire armoured Electric Power Cable heavy duty with stranded Aluminium Conductor 1100 Volt grade, cross-sectional area 70 Sqmm 3.5 Core, laid in trenches/surface of Wall/in GI Pipe along with Pole for connec-tion to OH Lines including Brass Cable Glands Mild Steel Flat Iron Clamps, etc. and Testing, complete all as specified and as directed.NOTE : Earthwork, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items. |
| 99 | Excavation in trenches not exc 1.5 mtr width and not exc 1.5 mtr in depth and getting out in soft / loose soil for laying /taking out ofLT UG cable complete all as specified and directed. |
| 100 | Returning, fillingin incl spreading, leveling , wateringand well ramming in layers not exc 25 cm thick in soils complete all as specified and directed. |
| 101 | Removal of surplus soil to a distance not exc 50 mtr away and depositing where directed as a level not exc 1.5 mtr above the starting point complete all as specified and directed |
| 102 | Supply and laying well burnt Bricks , locally available best quality (sub class \"B\" bricks) laid in trenches perpandicular to U/G cable for cable protection complete all as specified. |
| 103 | Supply , spreadand filling approved sand in cable trenches for cushioning of LT UG cable complete all as specified and directed.NOTE :- Punned thickness only will be measured and paid. |
| 104 | Supply & lay GI tubinglight grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc of size 50 mm dia bore complete all as specified anddirected . |
| 105 | M&L for earthing complete with galvanised steel earth plate electrodesize 600x600x6.0mm thick buried directly in groundvertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised earth lead wire 4.0 mm dia means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh refilling with vegetable soil without bolders and stones, gravels and aggregate etc,and CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion . NOTES : The unit rate includes for protection pipe and GI strip dia from top of earth plate up to 5.00 meter above ground level. |