Tender For Provision Of Otm Accommodation For Med Regt (Phase-I) At Jammu Under Ge Satwari.; 1 Construction of Singles living Accn for Havs/ORs (Double Storey),complete all as specified and shown on drgs 2 Construction of Cook House & Dining Hall(Single Storey) for Havs/ORscomplete all as specified and shown on drgs 3 Construction of Administration Building(Double Storey) complete all as specified and shown on drgs 4 Construction of EducationBuilding(Single Storey) complete all as specified and shown on drgs 5 Construction of Night Pickets with Guard Room (Single Storey),complete all as specified and shown on drgs. 6 Construction of Singles Living Accn for JCOs (Double Storey), complete all as specified and shown on drgs. 7 Construction ofJCOs Club/Mess (Single Storey), complete all as specified and shown on drgs. 8 Construction ofParking Shed for JCOs (Single Storey), complete all as specified and shown on drgs. 9 Construction of Singles Living Accn for Officer (Double Storey), complete all as specified and shown on drgs. 10 Construction ofServant Quarters for Officers (Double Storey), complete all as specified and shown on drgs. 11 Construction ofCar Garages for Officers (Single Storey) including Apron, complete all as specified and shown on drgs. 12 Construction of Storage Accn (Gen Store)(Single Storey) complete all as specified and shown on drgs. 13 Construction of Parking Shed (Single Storey) for ADM Bldg, complete all as specified and shown on drgs. 14 Construction of Sentry Box, complete all as specified and shown on drgs. 15 Construction ofElevated Sentry post,complete all as specified and shown on drgs. 16 Construction of Flag Staff with base complete all as specified and shown on drgs 17 Construction of Incinerator complete all as specified and shown on drgs. 18 Construction of Garbage bins/Refuse bin complete all as specified and shown on drgs. 19 Construction of Fire Points complete all as specified and shown on drgs. 20 Septic tanks with excavation in foundations in any type of soil, PCC bed, Fly Ash brick work including sludge chamber, septic tank designed to carry sewage and sullage water, vent shaft& connection etc for 20 users complete all as specified and as shown in drawings. 21 RCC Septic tank for 100 Users (With UPFLOW FILTER)designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter,.complete all as specified and as shown in drawings. 22 Soakage well, conventional type,with excavation in any type of soil, PCC 1:3:6in foundation, walls of honey combed Fly Ash brick masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Fly Ash Brick masonary in cement mortar, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats,size of soakage well 1.2mtrdia X 3mtr deep effective depth,. complete all as specified and as shown in drawings. 23 Soakage well excavation in any type of soil, foundation in PCC 1:3:6, walls of fly Ash honeycombed masonry, and slab in M-25 concrete including intercepting chambers, screen chambers, brick work in CM, RCC cover slab in M-25 filling with brick bats complete of size 1.8 mtr dia3.00m deep,.complete all as specified and as shown in drawings. 24 Lumpsum price worked out by the contractor for Internal Water Supply Works as listed in Schedule A Part-II. 25 Lumpsum price worked out by the contractor for Internal Electrification Work as listed in Schedule A Part-III. 26 Lumpsum price worked out by the contractor for Plumbing Works as listed in Schedule A Part-IV. 27 Lumpsum price worked out by the contractor for Site ClearanceWorks as listed in Schedule A Part-V. 28 Lumpsum price worked out by the contractor for Protective Works as listed in Schedule A Part-VI. 29 Lumpsum price worked out by the contractor for Area Drainage Works as listed in Schedule A Part-VII. 30 Lumpsum price worked out by the contractor for Chain Link Fencing Worksas listed in Schedule APart-VIII. 31 Lumpsum price worked out by the contractor for Sewage Disposal Works as listed in Schedule A Part-IX. 32 Lumpsum price worked out by the contractor for Road, Path & Culverts Works as listed in Schedule A Part-X. 33 Lumpsum price worked out by the contractor for Connecting Passage Works as listed in Schedule A Part-XI. 34 Lumpsum price worked out by the contractor for External Elect Supply Works as listed in Schedule A Part-XII. 35 Lumpsum price worked out by the contractor for External Water Supply Works as listed in Schedule A Part-XIII. 36 Lumpsum price worked out by the contractor for Lightening Protection Works as listed in Schedule A Part-XIV. 37 Lumpsum price worked out by the contractor for Air Conditioning & Desert Cooler Works as listed in Schedule A Part-XV. 38 Lumpsum price worked out by the contractor for Solar Water Heating Works as listed in Schedule A Part-XVI. 39 Lumpsum price worked out by the contractor for Water Cooler & RefrigerationWorksas listed in Schedule A Part-XVII. 40 Lumpsum price worked out by the contractor for Demolition& Dismantling Works as listed in Schedule A Part-XVIII. 41 INTERNAL WATER SUPPLY Chromium plated cast copper alloy shower rose square type of size 120mm x 120mm with 195mm long arm15 mm bore having 45 degree bend with brass flange,complete all as specified and as directed. 42 Chromium plated cast copper alloy sinkmixer 15 mm bore screwed down Wall mounted type, withswan neck swinging spout for mixing hot and cold water fixed to iron pipecomplete all as specified and as directed. 43 Chromium plated cast copper alloy wallmixer for mixing hot and cold water 3-in-1 quarter turn type with provision of over head shower systemscrewed downfixed to iron pipe of 15mm bore, complete all as specified and as directed. 44 Chromium plated cast copper alloy Pillar tap long body with swan neck type, screwed down high pressure capstan heads with or without lettered Hot or Cold with long screwed shanks and cups fixed to iron pipe of 15mm bore, complete all as specified and as directed. 45 INTERNAL ELECTRIFICATION DBOXX MCB protected socket with sheet steel enclosure single pole, 25 Amp with 3 pin plug top for AC connection from Socket point to stabilizer, complete all as specified and as directed.Make:- Havells Cat No-25 A MCB DBOXX COMBO or its equivalent in Anchor/L&T. 46 LED Lamp 10 Watt B-22 with holder base polycarbonate body and aluminium heat sink warm white,complete all as specified and as directed by Engineer-in-Charge.Make:- Havells Cat No-25 A MCB DBOXX COMBO or its equivalent of Anchor/L&T. 47 High performance IP-66 LED Streetlight 25 Watt, housing made of die-cast aluminium, with street optic lens, with all accessories and connecting up with and including provision of 3 core flexible copper wire of size 1.5 Sqmm from ceiling rose to 25 W LED light etc. and including 32mm bore GI light grade protection pipe upto i length suitable fixing accessorieson walls, complete all as specified and as directed by Engineer-in-Charge. 48 PLUMBING ITEMSUPVC(SWR),heel rest bend for 110 mm bore complete all as specified and as directed by Engineer-in-Charge. 49 CHAIN LINK FENCEConcertina coil fencing with punched tape concertina coil 600 mm dia, streched to 6 meter length, having 50 Nos spiral turns per 6 meter lengthy, spring core wire (2.59mm thick) of high tensile strenth of 1620 N/sqmm with tape (0.52mm thick) Hot dip galvanised upto 20 microns, weight of each coil 8.50 Kg and fixing the same exsiting Y-shaped angle iron with 6 horizontal R.B.T. (Reinforced Barbed Tape) wire, stud tied with G.I. staple sand G.I. clips to retain horizontal, clips shall be @ 5 Nos Per 2 spiral turns approximate 125 clips per coilo including necessary bolts complete all as specified and as directed. 50 ROAD, PATH & CULVERTPreparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like n. exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instructions, complete all as specified and as directed. 51 Road rummble straight 300mmx 150mm made out of hard acrylic polymers of colour yellow abd black with both side reflector for fixing with suitable bitumin and including fillingPCC 1:2:4 complete good finish surface, complete all as specified and as directed. 52 Road safety 580 mm dia convex mirror with framemade up of H2 polycarbonate reflective mirror having body ABS /fibre suitable for indoor/out door use with hood complete with mounting hardware including suitable height /dia ofMS tubular pipe with painting and grouting with PCC 1:2:4 complete good finish surface, complete all as specified and as directed. 53 Road safety 800 mm dia convex mirror with framemade up of H2 polycarbonate reflective mirror having body ABS /fibre suitable for indoor/out door use with hood complete with mounting hardware including suitable height /dia ofMS tubular pipe with painting and grouting with PCC 1:2:4 complete good finish surface, complete all as specified and as directed. 54 ELECTRIC OPERATED SECURITY BARRIERSupply, Installation, testing & Commissioning of Boom barrier BG100-L 6 Mtr, ESSL photo cell sensor Boom Barrier, ESSL manual switch SW01,with spike and operated push button including wiring and control panel, complete all as specified and as directed. 55 Solid PVC Wall panellling consisting of 5mm thick plain colur PVC sheet fixedon PVC frame, including 5mm thick PVC fillets of width 35 and 5mm palin clour PVC sheet in strips and channel, feathered at edges for fixing solid PVC Wall panelling insulated PVC wall lining ad solid PVC partitions, inclusive of solvent cement,compete all asspecified and as directed. 56 EXTERNAL ELECTRIC SUPPLYSupply, install, testing and commissioning of copper wound step down transformer, outdoor type, oil immersed, naturally cooled ONAN, rated temperature rise in oil & winding 40/45 degree centigrade complete with standard fittings of capacity 500 KVA HT 11 KV, 3 phase, LT 433V, 4 wire, 50 Hz of vector group Dyn-11 with off load tap changing device on HT side to vary secondary voltage from + 5 percent to – 10 percent in steps of 2.5% including cable box on LT side, first fill of new transformer oil having dielectric strength not less than 60KV, suitable mounting rails of appropriate gauge and other standard accessories all as per IS:1180 (Part 1): 2014. Note :- The rate quoted deemed to be inclusive of the following:- (a) Accessories such as oil level gauge, rating and diagram plate, monogram plate, explosive vent with diaphragm, thermometer pocket with thermometer, gun metal drain valve at bottom, Air release plug, inspection cover, lifting lugs, hooks, bi-directional plane rollers, oil temperature indicator, winding temperature indicator, silica gel breather & other standard accessories all as per IS:1180 (Part-1) : 2014 energy efficiency level 3 or as per latest amendment of IS 1180(2014) and losses as per clause No 7.8.1.1 of IS 1180 (Pt-I)-2014 etc. Any other item as per manufacturer recommendations for best function of transformer if required are deemed to be included in quotes rates. (b) The cost of PCC foundation required for installation of transformer shall be measured and paid separately under relevant schedule item. 57 Supply, fixing, testing and commissioning of out door type 11KV, 3 phase, 50 cycle (50HZ) totally enclosed metal clad switch gear panel board with SF6 vacum circuit breaker floor mounted with common copper bus bar, 11KV, 20KA, 630A, outdoor type 1-way (1 nos load breaker switch, 1 pcs Modules, 12 KV-28KV-1 Min, rated current bus bar 630 Amps compact, rated current cables switch discharge, 630A, short time withstand current (3 sec) cable switch disconnector 20 KA, short time withstand current (3 sec) vacum circuit breaker 20KA, rated current for Transformer T-off: 630A, impulse withstand voltage: to earth and between phases : 75 KV, insulation level power frequency 1 min 28 KV complete with following accessories.Make - ABB or equivalent 58 Incoming No. 1 (Load Breaker switch C, 11 KV 630A)a) Safe ring type C cable switch 12KV, 630A, 20KA-01No. HT Compartment-Circuit breaker T)- Breaker Modules.b) Snap action mech for manual operation -01 No.c) Cable bushing 400 series bolted 630 A,standard-01 Nosd) Capacitive voltage indication fixed type VPIS 9-15 KV -01 Noe) Fault passing indication - 01 nosOutgoing (V)11 KV, 630A T off to Transformera) Safe plus V is a vaccum circuit breaker modules with vaccum circuit breaker, three position isolator/earthing switch, bus bars, interlocking, earth bar and stored energy mechanism (A-Mech)b) Safe plus type V: Fix type vaccum circuit breaker 12KV, 630A, 21KA, stored energy Mech for man operation -01 No. 59 c) Manual operation-01 No.d) Protection relay (50-51N-51N) microprocessor self powered relay with O/C & 1E/F, Make- Ashida/Equivalent -01 No.e) Ring core current transformer for protection relayf) Ring core current transformer for meteringg) Cable bushing 400 series bolted, 630A-01 no.h) Arc proof cable cover completed incl. interlocking -01 No.j) Capacitive voltage indication fixed type VPIS 9- 15 KV Multi function meter (EM6436/equivalent) - 01 No.H-3 Metering Modules as Bus PT-Ma) Safe plus M is and air insulated metering module -01 No.b) Safe Plus type M-Air Insulated metering module 12 KV 630A, 20KA - 01 No.c) Bushing for connection external bus bar -01 Nod) 3 Voltage transformer of the ratio 11 KV/3/110V/3, 30VA, class 1.0 with HT fuses on the primary side and MCB on secondry side. e) RYB phase indications Additional equipments delivered seperately or mounted in respective panel.i) Manometer -01 Nosii) Operating handles 01 No(f) SLD of panel should be approved from GE before manufacture. 60 Providing platform for Transformer, Load breaker, APFC Panel and LT Main panel of size 8.0 x 4.0 x 1.25 Mtr high from GL including excavation in trenches 60cm, PCC 1:5:10 type D2 for foundation brick work in cm 1:6 PCC, 1:2:4 type B1 in copping plaster 10mm thick in cm 1:6 om brick /complete surface PCC 1:4:8 type B1 sub base 75mm thick as in floor PCC 1:2:4 type B1 100mm thick floor using extra cement returning filling and removal on surplus soil, chain link fencing 1.8m high made out of 4mm dia GI wire 150x100mm mesh MS work angle iron 50mmx50mmx6mm as fencing post in embeded in PCC work at 2 mtr interval each side as approved 1 No steel gate (3.5m clear) (fencing area cover 10M x 6M ) span as shown in drawing with locking arrangement made out of 15mm dia MS rod and 50x50x6mm angle iron frame . painting with 2 coat alu paint over a coat of red oxide primer and 3 coats of white washing on cement work including ISMB 100mm chanel 2 Nos for fixing transformer including making steps for Trasformer platform complete all as specified and directed by Engineer-in-charge. 61 Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mfa working pressure, complete all as specified and as directed. 62 Double compressionbrass cable gland duly nickel plated for fixing armoured cable in panel of 3½ core 240 Sqmm to 300 Sqmm size complete all as specified and as directed. 63 Double compression brass cable gland duly nickel plated for fixing armoured cable in panel of 3½core 95 Sqmm to 120 Sqmm size complete all as specified and as directed. 64 Double compressionbrass cable gland duly nickel plated for fixing armoured cable in panel of 3½ core 50Sqmm to 70 Sqmm size complete all as specified and as directed. 65 Double compression brass cable gland duly nickel plated for fixing armoured cable in panel of 3½ core 25Sqmm to 35 Sqmm size complete all as specified and as directed. 66 Double compressionbrass cable gland duly nickel plated for fixing armoured cable in panel of 4 core 6 to 16 Sqmm size complete all as specified and directed. 67 Double compressionbrass cable gland duly nickel plated for fixing armoured cable in panel of 2 core 6 to 16 Sqmm size complete all as specified and as directed. 68 Cable jointing kit for 1.1 KV grade cable for end termination joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, aluminium conductor cable of size 25 to 50 Sqmm, Indoor/Outdoor type complete all as specified and directed. 69 All as per description of Srl item No. 66 here-in-before but for cable of size 70 to 95 Sqmm. 70 All as per description of Srl item No. 66 here-in-before but for cable of size 185to 240 Sqmm. 71 Synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified. (For TFR & Load Breaker etc). 72 Cable route indicator of size 200 mm x 200 mm x 5 mm thick GI plate with insertion three on bolted welded to 35 mm x 35 mm x 6 mm angle iron 60 cm long and grouting the same in ground with PCC as required incl writing/marking arrow for LT/HT cable incl necessery earth work all as specified and directed. 73 Bracket for fixing of street light fittings bent to shape, made out of 32/40 mm dia GI pipe medium grade not less than 1.2 mtr long fixed with two sets of MS clamps made out of flat iron of size 50mmx6 mm fabricated to shape and fixed with nuts bolts and washers & two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge 74 Junction box of thermoplastics polystyrene/polycarbonate enclosure, shock proof, IP65( weather proof), rust proof, dust proof, water proof, internally embedded gasket with provision for all side cable entry through glands(IP-65) and/or grommets(IP-55). Size of enclosure: ( 250 x 180 x 110 ) mm With suitable connectors for /1Ph loop in loop out and branch out vibration proof connections and fixing on steel poles with 25x3mm thick 02 Nos of clamp with nuts and bolts and washers and proper thimbling complete all as specified and directed. 75 Supply, fabricating, installation, testing and commissioning feeder pillar box (KIOSK) out door type weather proof, dust vermine proof double door type CPRI approved LT panel made out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs), bus bar chamber enclosed complete, sheet fixed on angle iron frame/chanel of suitable size complete wiring alumnium bus bar chamber cable alley, cable glandes brass cromine plated of diffrent sizes suitable for incoming and out goingMCCBs panel paited with powder coated paint complete. (Note: SLD of panel should be approved from GE before manufacture.) 76 (a)Aluminium busbar of capacity 1200 Amps with eppoxy insulated supports 3 phase and neutral - 1 set 77 Incoming 78 (b) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 800 Amps - 01 Nos. 79 Outgoing 80 (c) MCCB 4 POLE 415 V 200- 250 A (36 KA) - 02 No (Outgoing) (P-3 & 4) 81 (d)MCCB 4 POLE 415 V 160 A (36 KA) - 02 No) (O/G) (P1 & APFC Panel) 82 (e)MCCB 4 POLE 415 V 100 A (36 KA) - 02 No) (For phase-II) (O/G) 83 (f)MCCB 4 POLE 415 V 63 A (25 KA) - 01 No) (O/G) for DG Panel 84 (g) MCB SPN, 32 Amp - 04 No. 85 (h) Digital type Ammeter including CTs and selector switch -1 No. 86 (j) Digital type Voltmeter and selector switches 0 - 500 V- 1 No 87 (k)Indicator - RYB- 1 Set, Internal Wiring of Panel, Civil Works & Labour Charges 88 Supply, installation, testing & commissioning of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 75 cms made out of 40x40x4 mm angle iron grouted on PCC platform upto 30 cms. PCC platform should be 60 cms above the Ground Level. Comprising the following:- .Note:- (i)The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii)Fabrication of feeder pillar box to be approved by CPRI.(iii)SLD of panel should be approved from GE before manufacture. 89 (a)Aluminium busbar of capacity 400 Amps with epproxy insulated supports 3 phase and neutral - 1 set 90 Incoming 91 (b) MCCB 250 A 4 Pole 35 KA - 01 No & fixed neutral link N with S/C & adj O/L releases phase indication indication lamlps with fuse 92 Outgoing feeders ; 93 c)MCCB 4 POLE 415 V 160 A (25 KA) - 01 No) (Outgoing) 94 d) MCB TPN, 40 Amp- 02 No. 95 e)MCB SPN, 32 Amp - 02 No. 96 f)Indicating lamp set LED type - 01 set. 97 g)Panel wiring with PVC insulated single core 2.5 sqmm copper cable. 98 h) PCC for fixing of LT Panel complete - 01 Job 99 All as per description of Srl item No- 74here-in-before but complete as per specification under:- 100 (a)Aluminium busbar of capacity 300 Amps with epproxy insulated supports 3 phase and neutral - 1 set 101 Incomer 102 (b) 160 A 4 Pole 25 KA MCCB- 01 No & fixed neutral link N with S/C & adj O/L releases phase indication indication lamlps with fuse 103 Outgoing feeders ; 104 (c)MCCB 4 POLE 415 V 63 A (25 KA) - 02 No) 105 (d)MCB TPN, 40 Amp - 02 No. 106 (e)MCB SPN, 32 Amp - 02 No. 107 (f) Volt meter & Amps mtr digital type 96 sqmm with CTs 400/5-3Nos and selector switch-01 set. 108 (g)Indicating lamp set LED type - 01 set. 109 (h)Panel wiring with PVC insulated single core 2.5 sqmm copper cable. 110 (j) PCC for fixing of LT Panel complete - 01 Job 111 All as per description of Srl item No- 74 here-in-before but complete as per specification under:- 112 Incomer 113 (b) 160 A 4 Pole 35 KA MCCB- 01 No & fixed neutral link N with S/C & adj O/L releases phase indication indication lamlps with fuse 114 Outgoing feeders ; 115 (c) MCCB 63 Amps TP 25 KA -04 Nos, with fixed neutral and S/C and O/L releases -05 Nos 116 (d) MCB 32 Amps 10 KA - 02 Nos for circuit control 117 (e)Volt mtr digital type 96 sqmm with selector switch -01 set. 118 (f) Amps mtr digital type 96 sqmm with CTs 400/5-3Nos and selector switch-01 set. 119 All as per description of Srl item No- 74 here-in-before but complete as per specification under:- 120 (a)Aluminium busbar of capacity 250 Amps with epproxy insulated supports 3 phase and neutral - 1 set 121 Incomer 122 (b) 63 A 4 Pole 16 KA MCCB- 01 No & fixed neutral link N with S/C & adj O/L releases phase indication indication lamlps with fuse 123 Outgoing feeders ; 124 (c) MCCB 32 Amps TP 25 KA -03 Nos, with fixed neutral and S/C and O/L releases -05 Nos 125 (d) MCB 32 Amps 10 KA - 02 Nos for circuit control 126 (e)Panel mounted Automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in panel mounted ,IP65 with the contactor,MCBs and copper circuit wiring (min.16sqmm) should enough to take: three-phase load of 12KW;contactor Rating 80Amps - 02 No 127 (f)Volt meter digital type 96 sqmm with selector switch -01 set. 128 (g) Amps meter digital type 96 sqmm with CTs 400/5-3Nos and selector switch-01 set. 129 (h)Indicating lamp set LED type - 01 set. 130 (j)Panel wiring with PVC insulated single core 2.5 sqmm copper cable. 131 (k) PCC for fixing of LT Panel complete - 01 Job 132 Disconnecting and Taking out unserviceable cables ofany size from ground, complete all as specified and as directed. 133 Supply, installation, testing & commissioning of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door typeincluding locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 75 cms made out of 40x40x4 mm angle iron grouted on brick masonary platform upto 30 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- . 134 (a) 01 set of 200 Amps TPN aluminium bus bar of suitable length and of crossection as per design with colour codding. Bus bars shall be designed to with stand a fault level of 16 KA at 415 volts. (b) Supply and fixing MCB TPN 40 Amp 10 KAMakes : Legrand /Schneider/Siemens -01 No as incoming.(c) Supply and fixing MCB TPN 32Amp 10 KA, Makes : Legrand /Schneider/Siemens -01 No as outgoing(d) MCB SP, 6 Amps 240 Volts AC 10KA - 04 Nos. Make :- Legrand/Schneider/Seimens(e) Automatic street light switch :- Make : Healer enterprises Model No SWADEEP 02EC5KW3P (f) Digital type amp meter 0-500Amp with CT’s & selector switch - 01 No. (g) LED Indicating lamp (RYB-one set) (h) Digital voltmeter 0-500 volts with selector switch 135 Supply and installations of silent Diesel Engine Generating set 415 Volts, 3 phase 4 wire, engine as per IS: 10001/10002 and alternator as per IS 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy with AMF control Panel as per CPCBIV+ norms and foundation etc of capacity25 KVA or its nearest higher size.A - DIESEL ENGINE:Liquid cooled, Electric start, four stroke, three cylinders, totally enclosed diesel engine, Terbocharged, developing 35.1 HPat 1500 RPM at NTP. The Engine is suitable for generating set application and fitted with the following standard accessories(i) Flywheel to suit coupling, (ii) Suitable coupling, (iii) Water cooling arrangement, (iv) Radiator with fan (v) Lube Oil Filter, (vi) Lube Oil Pump, (vii) Fuel Pump, (viii) Hoses to fuel tank, (ix) Air Cleaner assembly, (x) (Residential Heavy Duty Silencer (xi) Battery charger (xi) Fitted with requisite temperature and pressure gauges. 136 B - ALTERNATOR25 KVA TP CG/LS alternator at 1500 RPM, 0.8 lagging power factor, providing three Phase 415 Volts suitable for 50 Hz, H class insulated winding, Close-direct-coupled, Self-excited and self-regulated type, screen protected, mounted on rigid MS sheet channel base-frame. The alternator shall confirm to IS: 13364, IS: 4722, BS EN 60034-1, IEC: 34 and suitable for tropical condition. 137 C - CONTROL PANELFitted inside Canopy, fabricated out of CRCA Sheet of suitable thickness as per CPCB latest provision, cubical type, totally enclosed, Powder Coated, Control Panel incorporating the following:1. 1 No. Sedamac unit comprising: - Lube oil Pressure metering & Safety - High Water Temperature metering & Safety - Fuel Level Gauge in % metering & Safety - Voltage metering & Safety - Ampere metering & Safety - Frequency meter metering & Safety - Engine RPM metering & Safety & many more metering & Safeties - Power metering & Safety - Power factor metering 02. 1 Set MCB03. 1 Set of suitable Current Transformers04. 1 No. Toggle switch & Indicating lamps.05. Input & Output Terminals for incoming & outgoing E. AMF Panel- AMF Panel suitable for 25 KVA DG Set fixing of inside of canop for DG Set with fixing on suitable size of angle frame complete all as specified and directed by Engr In Charge. 138 F- ACCESSORIES01. BASE FRAME: Suitable base frame of sturdy design with necessary reinforcement and with in-built diesel tank.02. Fuel Tank:fuel tank of sheet metal, suitable enough for minimum 8 hours running of DG set complete with drain valve, air vent, inlet, outlet connections and mechanical gauge.03. BATTERY: - One No. battery of 12 volt charged of Amaron or Exide make with its leads. 139 EXTERNAL WATER SUPPLYSupplying, laying, Jointing and testing ductile iron pipe 150mm bore spigot & socket class K-7 as per IS-8329 with inside cement lined complete with push on rubber joints all as specified and directed by Engr-in-Charge.(Note:- During the laying of pipe line any damage to existing services, shall be made good/repaired by contractor as per existing system and rates are deemed to be included in quoted rate). 140 Supplying, Laying, Jointing and testing ductile iron pipe 100mm bore spigot & socket class K-7 as per IS-8329 with inside cement lined complete with push on rubber joints all as specified and directed by Engr-in-Charge.(Note:- During the laying of pipe line any damage to existing services, shall be made good/repaired by contractor as per existing system and rates are deemed to be included in quoted rate). 141 Construction of one brick thick (23 cm) masonary valve pit built in cement mortar 1:4 of size 150cm x 120cm x150cm (internal dimension) over 15cm thick PCC 1:3:6 type C-2 sub base extended alround 15cm beyond external edge of brick work including plastering 15mm thick in cement mortar 1:4 internally and flush pointing to brick wall surfaces externally as work proceeds complete with MS sheet cover 10 SWG with handle, angle iron frame 40mm x 40mm x 6mm (grouting with anchor fasteners length not less than 15cm - 04 Nos) including locking arrangement and painting, complete all as specified and directed by Engr-in-Charge.(Rate quoted by the tenderer shall deemed to be included the cost of excavation and earth work). 142 Description all as per Srl item No 83 here in before but of size 120cm x 90cm x 105cm (internal dimension). 143 Description all as per Srl item No 83 here in before but of size 90cm x 90cm x 90cm (internal dimension). 144 Pipeline route indicator of size 200 mm x 200 mm x 5 mm thick GI plate with insertion three on bolted welded to 35 mm x 35 mm x 6 mm angle iron 60 cm long and grouting the same in ground with PCC as required incl writing/marking arrow for water supply line incl necessery earth work,complete all as specified and as directed. 145 Disconnecting from pipe lines and Taking out from existing locations, sluice valves of the following sizes, complete all as specified and as directed:- 146 (a) 80mm bore 147 (b) 100mm bore 148 (c) 150 mm Bore 149 AIR CONDITIONING & DESERT COOLERAutomatic boost / bulk transformer for low & high voltage correction equipped with electronic transistorized relay suitable for correction on single phase50 c/s AC supply complete with voltmeter and designed for Input voltage 175Vto 250Vand output voltage 215V to 250V of capacity 5 KVA complete all as specified and as directed by Engineer-in-Charge. 150 Desert cooler with steel body having 450 mm fan size (heavy duty) with aluminium blade ISI marked electric driven (single phase) operating switch three step having nominal air flow capacity of 4000 CFM with wall thickness of sheet 1 mm and water tank and body pillar 1.5 mm thick including prewired electric control panel with immersed pump duly ISI marked pump and fan motor inlcuding provnof floot valve, complete all as specified and as directed by Engineer-in-Charge. 151 GEYSER & SOLAR WATER HEATING SYSTEM Stand made out of angle iron 50mm x 50mm x 6 mmand flat iron 50mm x 6 x mm,suitable forcold water tanks including painting the stand with 2 coat of synthetic enemel paint over a coat red oxide primer, complete all as specified and as directed by Engineer-in-Charge. 152 WATER COOLER & REFRIGERATIONAutomatic boost/bulk transformer for low & high voltage correction equipped with electronic transistorized relay suitable for correction on single phase 50 c/s A/C supply complete with voltmeter and designed for input voltage 175V to 250V and output voltage 215V to 250V of capacity 2.0 KVA complete all as specified and as directed by Engineer-in-Charge. 153 Supplying, installtion, testing and commissioning of refrigerator, electric driven (single phase), capacity more than 195 ltrs & upto to 210 Litres BEE 5 star rated,suitable for operation on single phase , 240 V, 50 Hz AC supply complete all as specified and as directed by Engineer-in-Charge. 154 Supply, installtion, testing and commissioning of refrigerator, electric driven (single phase), capacity more than 310 ltrs & upto to 360 Litres BEE 5 star rated,suitable for operation on single phase , 240 V, 50 Hz AC supply complete all as specified and as directed by Engineer-in-Charge. 155 ELECTRIC CHIMNEY FOR KITCHENSupply, installation, commissioning and testing Wall Mount Commercial type Electric Chimney for Kitchen including the following equipments complete in all respect 156 (a) Air Suction Capacity -1800CFM, , Voltage (V)-220-240, Power (W) - 220W, Phase-Single, Motor Power- 1 HP 157 (b) Material -SS, Mount Type- Wall Mounted, , Shape -Rectangular, duct complete. 158 (c) Material & Labour of Exhaust Hood, Shape -Rectangular complete. 159 Stainless Steel Hot Case Service Counter for cook house, Four Pan 1800mm AQUARIUS HTSC1002O7, size : 1800 x 730 x 915mm, power : 2.5kw, voltage : 220 volts. Complete all as specified and directed. 160 Stainless Steel Hot Case Service Counter for cook house, six Pan, 2300mm AQUARIUS HTSC1003O7,size : 2300 x 730 x 915mm, power : 3.0 kw, voltage : 220 volts. Complete all as specified and directed. 161 UPSSupply and fix UPS for 30 min back up single phase AC input voltage range 160 to 260 V and out put voltage 230 ± 1%,50 Hz of capacity 3 KVA,with noise level <50 db with overload and short circuit protection, efficiency>90% complete all as specified and directed. 162 UPS for 30 min back up single phase AC input voltage range 160 to 260 V and out put voltage 230 ± 1%, 50 Hz of capacity 5 KVA,with noise level <50 db with overload and short circuit protection, efficiency>90% complete all as specified and directed. 163 Schedule of Credit Works as listed in Schedule A Part-XIX has been attached in tender in PDF format amount of schedule i.e Rs. 25,21.119.80 shall be deducted from the total amount of BOQ to arive at the contract sum.