| 1 | Demolition of brickwork built in cement mortar includingtaking out roots vegetation if any at any position and removal from site, complete all as directed. |
| 2 | Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) removing rubbish off the premises etc. complete all as directed |
| 3 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for, removing rubbish off the premises etc. complete all as directed. |
| 4 | Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 5 | Dismantling timber scantlings 40 sq. cm and over in section, in any position of Framed work, complete all as specified and directed. |
| 6 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 7 | Dismantling Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings any thickness, complete all as specified and directed. |
| 8 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards/slabs of any thickness including cover fillets complete all as directed. |
| 9 | Demolition and breaking up 150/160mm dia of drain pipes(salt glazed were or AC or reinforced cement concrete) set in cement mortar, including cement concrete bedding and removal of debries / rubbles etc to a distance not exceeding 50mcomplete all as specified and as directed.Note: Necessary excavation and earth work shall be measured and paid separately. |
| 10 | Demolition and breaking up 200/225 mm dia of drain pipes(salt glazed were or AC or reinforced cement concrete) set in cement mortar, including cement concrete bedding and removal of debries / rubbles etc to a distance not exceeding 50mcomplete all as specified and as directed.Note: Necessary excavation and earth work shall be measured and paid separately. |
| 11 | Dismantling floor hearth or wall tiling and stone slabs including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises etc complete all as specified and as directed. |
| 12 | Taking down cement plaster or lime plaster on walls /ceiling of any description from concrete or brick wall etc. including raking out joints, hacking for key, scrubbing down with water and disposing off the retrieved debris as directed including necessary scaffoldings etc complete all as specified and as directed. |
| 13 | Materials and Labour for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 14 | Materials and Labour for hardcore of broken bricks of gauge exceeding 63 mm butnot exceeding 100 mm, deposited, spread and leveled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 15 | Materials and Labour for plain cement concrete (1:4:8) type D-2,using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed. |
| 16 | Materials and labour PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregated) as in surfaces channels and drains incl necessary formwork complete all as specified and directed. |
| 17 | Materials and labour plain cement concrete Type B0 1:2:4 (using 12.5mm graded stone aggregates) as in lintels upto1.5m clear span,cills,steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, benching, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering,slightly rounded or chamfered angles and throating, as directed inclusive of necessary form work complete all as specified and directed. |
| 18 | Materials and labour precastreinforced cement concrete, type B1, 1:2:4 (20 mm graded aggregate)as in cover slabs (for Manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and similar work incl necessary formwork set in cement mortar 1:4 complete all as specified and directed. (Note: Steel reinforcement shall be measured & paid separately) . |
| 19 | M&L for reinforced cement concrete(1:2:4) type B-0 (Nominal Mix) (using 12.50 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified anddirected.Note : Reinforcement shall be measured and paid separately under relevant item. |
| 20 | Materials and Labour for reinforcedcement concrete (1:2:4) type B-0 (using 12.5 mm graded crushed stoneaggregate) as in chajja, kitchen platform etc.complete all as specified and as directed. |
| 21 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitered/stopped ends etc. complete all as specified and directed. |
| 22 | M&L for brick work with sub class \"B\" burnt clay bricks straight or curved on plan exc 6 meter mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 23 | M&L for brick work with sub class \"B\" burnt clay bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed. |
| 24 | M&L for Brick work with sub class \"B\" brick in one brick thick honey comb work built in cement mortar (1:4) complete all as specified. |
| 25 | Use and waste form work to sides of foundation, footings, bases of columns, plinth beams flat rough finished surfaces of concrete complete all as specified and as directed. |
| 26 | Use and waste formwork to soffits of suspended slabs such as roof slab, floor slabs, landings and similar works,for rough finished flat surfaces of concrete, thickness of slab not exc 200 mm,complete all as specified and directed. |
| 27 | M&L for second class hardwood, scantlings, wrought, in timber framed and fixedwork complete all as specified and directed. |
| 28 | Materials and Labour for TMT bars 10 mm dia and over, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 29 | Materials and Labour for TMT bars 5mm dia over upto and including 10mm dia in stirrups, spacers and binders, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 30 | Supply and fixing rolled mild steel in roof trusses (framed),trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. steel conforming to Fe 410-W (Gde-E-250)quality A,complete all as specified and directed by Engineer-in-Charge.. |
| 31 | Materials and Labour for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and as directed. |
| 32 | S&F for aluminium anodised snap grid frame work of size 600mm x 600mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestos E-board (plain), HSPC fixed to frameincluding providing two coats of white wash complete all as specified and as directed.Make of E-Board : Everest / Lafarge / Armstrong/ Visaka Industries Ltd. |
| 33 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of profile as approved, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 34 | S&F for pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and as directed.Note : Colour of ridge shall be same colour as that of sheet used for roof. |
| 35 | Materials and labour for75mm thick PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as sub base of flooringcomplete all as specified and directed. |
| 36 | Materials and labour for coloured 450x300x7-8 mm thick glazed ceramic tileson vertical surfaces such as skirting, dado and risers to steps etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 10mm thickbacking coat in cement mortar (1:4) , complete all as specified and directed. |
| 37 | Materials and labour for non skid ceramic colouredtiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed or bedding layer of cement mortar (1:6) for laying of floor finishes complete all as specified and directed. |
| 38 | M&L for machine pressed precast concrete interlocking paver block, design & shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. complete all as specified and as directed. |
| 39 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) and finished the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 40 | M&L for 15 mm thick renderingin cement mortar (1:6) on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 41 | M&L for 15 mm thick renderingin cement mortar (1:4) on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 42 | M&L for rendering 20 mm thick on fair faces of external wall of brick work or stone surfaces in two layers (10 mm and 5 mm thick) in cement mortar (1:4) using water proofing compound in top layer andfinished even and smooth without using extra cement complete all as specified and directed. Note:(water proofing compound measured as separately) |
| 43 | Supply only liquid Water Proofing Compound of approved make. |
| 44 | Materials and labour for applying two coats of white wash on new surface of wall including preparation of surface, complete all as specified and directed. |
| 45 | M&L for preparation of newly plastered surfaces of walls, etc and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed. |
| 46 | M&L for preparation of newly plastered surface of walls etc and applying two coats of distemper oil emulsion over a coat of chalk whiting priming paint over 1.50 mm thick wall care putty complete all as specified and as directed. |
| 47 | Materials and labour for preparation of new plastered or unplasterd surfaces and applying two coats of cement based paint over a coat of alkali resistant primer on wall complete all specified and directed. |
| 48 | M&L for preparation newly plaster surfaces of wall, chajja, facia etc and applying two coats of 100% premium Acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistant as per IS-15489:2004 alkali and fungal resistant exterior paint of required shed (company depot tinted)with silicon additives 1.43 litrs/ 10 Sqm over and including primer coat of exterior primer applied 0.90 litre/10 Sqm over new surfaces using Airless spray technology with maximum working pressure of 3300 PSI and capable of operating single spray gun with a maximum material hose length of 30 mtr, the spray machine shouldbe of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories complete all as specified and directed. |
| 49 | Materials and labour for preparing of new wood and wood based surfaces of any description , over 10 cm in width or girth, not otherwise describedand applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed. |
| 50 | Materials and labour for preparing of old painted wood and wood based surfaces of any description over 10 cm width or girth, not otherwise describedand applying one coat of synthetic enamel paint complete all as specified and directed. |
| 51 | Materials and labour for preparing of new steel surfaces of any description , over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 52 | M&L for preparing of old steel & ironsurfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paintcomplete all as specified and as directed. |
| 53 | S&F in repair 15mm bore, Bib tap standard of PTMT any colour screwed for iron pipe and fixed (Minimum weight 15mm - 90gms complete all as specified and as directed. |
| 54 | S&F in repairs PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. |
| 55 | S&F in repairPVC (SWR) pipes 110mm bore, single socketed in any length with rubber ring joints fixed to walls using MS holder bat, fixed complete all as specified and as directed. |
| 56 | Supply and fixing PVC (SWR) branch piece (Single Y) equal or unequal 110mm bore with access door, complete all as specified and directed. |
| 57 | M&L for concrete bed , plain cement concrete (1:3:6) type C-2 ( using 40mm graded crushed stone aggregate) in bedding to SGSW/NP2 drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested,for 150mm pipe, complete all as specified and as directed. |
| 58 | M&L for concrete bed , plain cement concrete (1:3:6) type C-2 ( using 40mm graded crushed stone aggregate) in bedding to SGSW/NP2 drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested,for 200mm pipe, complete all as specified and as directed. |
| 59 | M&L for salt glazed stone ware drain pipes 150 mm bore, grade \"A\" laid in trenches, jointed cement mortar and tested complete all as specified and as directed. |
| 60 | M&L for salt glazed stone ware drain pipes 200 mm bore, grade \"A\" laid in trenches, jointed cement mortar and tested complete all as specified and as directed. |
| 61 | Cutting into existing manholes for connecting new drains, making good to pipe and plastering the disturbed portions in cement mortar (1:3) to match with surround surfaces, cutting out existing benching and forming branch channel (1/2 round or 3/4 round section) in cement concrete (1:2:4) type B-1 finished smooth and reforming benching as required for 100/110 mm bore pipe complete all as specified and as directed. |
| 62 | Cutting into existing manholes for connecting new drains, making good to pipe and plastering the disturbed portions in cement mortar (1:3) to match with surround surfaces, cutting out existing benching and forming branch channel (1/2 round or 3/4 round section) in cement concrete (1:2:4) type B-1 finished smooth and reforming benching as required for 150/160mm bore pipe complete all as specified and as directed. |
| 63 | Cutting into existing manholes for connecting new drains, making good to pipe and plastering the disturbed portions in cement mortar (1:3) to match with surround surfaces, cutting out existing benching and forming branch channel (1/2 round or 3/4 round section) in cement concrete (1:2:4) type B-1 finished smooth and reforming benching as required for 200/225mm bore pipe complete all as specified and as directed. |
| 64 | Taking out liquid/solid content from manhole/sump/septic tank of any size any depth by super succer machine or high pressure pump, cleaning thoroughly including disposal of liquid/solid content out of the Cantt Area and covering with a layer of soil not less than 15cm thick complete all as specified and as directed. |
| 65 | EM PORTIONTaking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc |
| 66 | Materials and labourfor concealed point wiring with two runs of FRLSH PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead, drawing through in and including PVC rigid conduit of size not less than 20mm, with all fittings & accessories including provn of MS sunk terminal box of appropriate size suitable for switch fixed flush to wall for mounting switch, sockets, fan regulators etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / call bell controlled by one switch one way 5 Amps completeall asspecified and directed .NOTE : Cost of cutting, chiseling, and making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates. |
| 67 | All as per Item No.66 above but for One 2/3 pin socket outlet 5/6Amps on independent board |
| 68 | All as per Item No.66 above but forOne 2/3 pin socket outlet 5/6 Amps on the same board with other switches. |
| 69 | All as per Item No.66 above but for one switch socket combination 15/16 Amps on independent board with cable 2.5 sq mm size and earth wire 2.5 sqmm |
| 70 | S&F for switch piano, flush type single pole, 230 volts, 5 Amp two waybearing ISI marked complete all as specified and as directed. |
| 71 | Supply and fixing Socket outlet 5 in 1, 5 Amp flush type universal, 240 volts, complete all as specified all as directed. |
| 72 | Supply and fixing Switch socketcombination 3/5 pin, 2 in 1,5 Amps flush type, 240 volts, complete all as specified all as directed. . |
| 73 | Supply and fixing Switch socket combination multipurpose 3/5 pin, 5A/16 Amps, 5 in 1, flush type, 240 volts, complete all as specified all as directed. . |
| 74 | S&F for ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body bearing ISI marked and including PVC box complete all as specified and as directed. |
| 75 | Supply and fixing electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 sweep/1400 mm, 120 Watt complete all as specified and directed. |
| 76 | Supply and fixing for lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings including fixing for one 9 Watt LED Lamp complete all as specified and as directed. |
| 77 | S&F LED tube light Inverter type with minimum 4 hrs. backup, batten (1.2M) made of extruded aluminum housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficiency of 115 lumen per watt and total power consumption not more than 18/20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a colour temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete all as specified and directed. |
| 78 | Supply and fixing MCB distribution board SPN 8 way double door, sheet steel, phosphatised,powder coatedwith 200 amps bus-bar, neutral link, earth bar and din rail 240 V, complete all as specified and directed. by Engineer-in-charge. |
| 79 | Supply and fixing MCB Single pole and neutral, 6 to 32 Amps,240 volts 10 KA rupturing capacity, C series complete all as specified and directedby Engr-in-charge. |
| 80 | Supply and fixing MCB Single pole, 240 volts 6 to 32 Amps 10 KA rupturing capacity, C series complete all as specified and directedby Engr-in-charge. |
| 81 | Excavating in trenches not exc 1.5m wide and not exceeding 1.5 m in depth, for foundations, etc, or for shafts, wells, cesspits, manholes, pier holes, cable trench etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 82 | Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 83 | Removing excavated soils to a distance not exceeding 50 meters and depositing where directed at a level not exceeding. 1.5 meter above the starting point complete all as specified and directed. |
| 84 | Materials and labour for clear sand cushioning with dry clean sand for protection of cable,15cm below the cable and 8cm above the cable, complete all as specified and as directed. Note : Punned thickness shall be measured for payments. |
| 85 | Supply and laying unreinforced precast concrete cable cover class LV, type 1, flat size 250 x 150 x 40 mm for cable protection, complete all as specified and as directed. |
| 86 | Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 10 sq.mm 2 core, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipeincl taking down old unserviceable onecomplete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items.(2) Excavation and earth work shall be measured and paid separately.complete all as specified and directed. |
| 87 | Materials and labour for GI pipe light grade with all fittings complete grouted in ground all as specified for 32mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable including taking down old unserviceable complete all as specified and directed. |
| 88 | Supply and fixing in repairs 35/40 Watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having Bottom Opening separate driver compartment with IP66 protection and impact resistance of IK08. including all fixing arrangement and taking down old light fittings of any type complete all as specified and as directed. |
| 89 | S&F for street light bracket arm of length not less than 1.5 m made out of GI tubing, 40mm bore, light grade fixed to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer on steel surfaces complete all as specified and as directed. |
| 90 | M&L for earthing complete with GI earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25m below ground levelwith the top edge of earth plate at depth not less than 1.5m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @ 15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing the base in which pit cover rests made up of MS angle iron (Frame) complete as specified and as directed. |
| 91 | M&L for point wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLHSPVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point terminated in and including 1.6mm thick mild steel sunken terminal box of suitable size with 3mm thick hylam sheet top cover fixed with suitable size ofbrass screws suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and as directed. |
| 92 | Supply, installation, commissioning of Glass Top Deep Freezer single phase 240 volt, 50 Hz of capacity 220 ltrs complete all as specified and directed by Engr-in-Charge. |
| 93 | Supply, installation, commissioning of Glass Top Deep Freezer single phase 240 volt, 50 Hz of capacity 320 ltrs complete all as specified and directed by Engr-in-Charge. |
| 94 | Supply and fix Voltage stabilizer for automatic operation, single phage naturally air cooled for input variation between 170V to 250V with output voltage stabilizer at 230V with accuracy of +_ 2.5% and capacity 5 KVAcomplete all as specified and directed |