Tender For Enhancement Of Illumination And Installation Of Fire Fighting Equipment At Dahisar Hindu Cemetery Dahisar West In Rnorth Ward-Removal of point wiring (Light ,fan points,IP,PP,call bell,gong bell,bell indicator points) Removal of switchgears/ DBs upto 200 Amp. Removal of fixtures / fittings / ceiling fans / bulkhead / street light / gyeser etc. Removal of cable from 1.5 sq.mm to 3-1/2 core x 35 sq.mm. Removal of street light poles (4.5 to 11 mtrs. length, all types of G.I. & M.S. poles). Removal of switchgears / ELCB / RCCB from 63 Amp to 100 Amp. Removal of switchgears / ELCB / RCCB upto 32 Amp / 40 Amp. Removal of control panel above 300 Amp incomer upto 800 Amp incomer with busbar, capacitor etc 32 Amp. 240V DP Switchfuse unit with CRCA sheet steel powder coated enclosure with rewirable fuses 63 Amp. 415V DP Switchfuse unit with CRCA sheet steel powder coated enclosure with rewirable fuses 200/250 Amp. 415V TPN Switchfuse unit with CRCA sheet steel powder coated enclosure with HRC fuses & switch links and padlockable arrangement. 250 Amp. 415V FP ON Load Changeover Switch with CRCA sheet steel powder coated enclosure. 1.1 kV grade 2 Noss. (P+N) copper conductor flexible cable of area 4.0 sq mm and 1Nos. (E) 2.5 sq. mm copper cable for 30 /32 Amp. single phase switch. 3(PH) Noss. single core Cu PVC insulated flexible cable of 25 Sq.mm. for phases & 1 single core Cu PVC insulated flexible cable for neutral of 10 Sq.mm. for 63 Amp TPNSS switch. IP 42 Wall/column Mounted distribution board with one Nos of DP 16/32A MCB as incomer and 6 Noss 6A/10A SP MCB as outgoing (12 way SPN DB) IP 42 Wall/column Mounted distribution board with one Nos of 16/32A 4P MCB and 3 Noss 16/32A DP MCB as outgoing (4 way TPN DB) 1st category Al armoured cables FRLS outer sheathed- 2C x 6.0 Sq.mm 1st category Al armoured cables FRLS outer sheathed- 4C x 10 Sq.mm Cable End Termination For Aluminium Cables – 2C x 6 Sq.mm Cable End Termination For Aluminium Cables – 4C x 10 Sq.mm Supply & laying I.S.I. mark B class GI Pipe-100 mm dia. Supply & Laying of double wall corrugated ( DWC) pipe 120 mm OD / 103.5 mm I.D. Light /Fan / Ex. fan Points 2/3 Pin Independent Plug (IP) 15 / 5 A / 6 A Combined Power Plug Socket Point with Fuse and Indicating Lamp, One 15 Amp SP Switch 5A/6A - 3/5 Pin Plug On Board Exhaust fan of 150mm sweep, 1400RPM, AC, 230V , 50 Hz, single phase complete with all necessary accessories for completing installation Pedestal fan of 450mm sweep, 230 Volts,AC 50 Hz, oscillating type complete with guard and regulator 3 mtrs. of 3 core 1.5sqmm, PVC insulated , copper conductor , flexible wire and Hand shield type 3 pin plug top. Wall mounting fan of 400mm sweep, 230 Volts,AC 50 Hz, oscillating type complete with all necessary accessories for completing installation. Ceiling fan of 1200 mm sweep with all accessories including Electronic Regulator for completing installation Fan safety rope/ Fan wire. Outdoor LED Street Light fittings – 70-90 W SITC LED Flood Light Fitting -150 W LED Gate post fitting Race way for fitting / fixtures by using G. I. Reducer and 50mm dia. B class G.I. pipe of 300mm length (for fixing gate lights) LED Tubelight fixtures 1X 18W LED Bulkhead fitting 410 SP-2 Swedged pole 7meter in length weight of pole 73 Kgs. (Add 10 Kg. weight of sleeve & base plate) Double arm bracket SMCJB - 1414, Hinged cover, Size 170 x 170 x 105mm Time controller for street light poles Excavating the trenches and refilling the same after the cable is laid in approved manner (Size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 Cu. Mtr. = 2.2 RMT. And reinstatement. 415V Main Distribution Panel 1 short circuit reating 50kA for 1 Sec. 250A (Thermal magnetic overload, short circuit releaseMCCB with rotary operating mechanism as incomer with digital ammeter, voltmeter with selector switches, phase indicating lamp with required accessories, 1Nos. 32A, 63A, 1Nos. 80A, 2Noss. Of 100A, 1Nos. 160A & 2Noss. 200A (total 8Noss.) MCCB of short circuit rating 25kA for 1 sec. as outgoings. 1st category Al armoured cables FRLS outer sheathed- 3.5C x 185 Sq.mm 1st category Al r armoured cables FRLS outer sheathed- 4C x 16 Sq.mm Cable End Termination For Aluminium Cables – 3.5C x 185 Sq.mm Cable End Termination For Aluminium Cables – 3.5C x 95 Sq.mm Cable End Termination For Aluminium Cables – 4C x 16 Sq.mm Cable End Termination For Aluminium Cables – 3.5C x 35 Sq.mm Swan neck type bracket for fixing HPMV / HPSV lamp fixtures mounting on wall / shed etc. 0.5 to 1.2 Mtrs. Earthing station Bare G.I. Conductor size 10 SWG Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on Wall. Providing Round bottom FIRE Bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook. Providing and fixing fire doors with 2 hour fire rating conforming to IS: 3614 (Part 2), BS 476 (Parts 20 & 22), ISO 834 ; 45 mm thick fully flush, double skin door shell with lock seam joints at stile edges made from 1.25 mm thick galvanized steel sheet including door frames made from 1.6 mm thick galvanized steel sheet formed to double rebate profile of size 143 mm x 57mm as per manufacturers instructions, door frames and shutter primed with Zinc Phosphate stoving Primer and finished with Polyurethane Aliphatic grade or epoxy paint including ironmongery consisting of stainless steel ball bearing butt hinges 3 mm thick fixed flush to the frame and shutter, full width horizontal handles (panic bar), concealed flush bolts, door closers, other standards fixtures and fasteners, etc. complete for the following clear opening sizes: