}

Land And Infrastructure Development Of Sheep Breeding Farm At Chanderkote By Way Of Constt. Of Chain Link Fencing, Sheep Shed With Batten Floor And Officer Incharge Buildingunder Special Assistance To States/Union Territories For Capital Investment, ramban-Jammu And Kashmir

Tender Notice

51693086
Corrigendum : Land And Infrastructure Development Of Sheep Breeding Farm At Chanderkote By Way Of Constt. Of Chain Link Fencing, Sheep Shed With Batten Floor And Officer Incharge Buildingunder Special Assistance To States/Union Territories For Capital Investment
Tender
Indian
Jammu And Kashmir
Ramban
17-10-2025

Tender Details

Land and Infrastructure Development of Sheep Breeding Farm at Chanderkote by way of constt. of Chain link fencing, Sheep Shed with Batten Floor and Officer Incharge buildingunder Special Assistance to States/Union Territories for Capital Investment- 1 Earth work in excavation by manual means in trenches for foundations, drains,pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspitsand the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of Soil @75% and Oridinary Rock @ 25% 2 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 3 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 4 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) 5 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 6 Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns 7 Columns, piers, abutments, pillars, posts and struts 8 Lintel, beams, plinth beams, girders, bressumers and cantilevers. 9 Suspended floors, roofs, landings, balconies and access platforms 10 Edges of slabs and breaks in floors and walls. Under 20 cm wide 11 Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs andsteps etc. 12 Structural steelworkinbuiltupsections,trussesandframedwork, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Riveted and bolted 13 Welded 14 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in- charge. Made of G.I. wire of dia 4 mm 15 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work 16 Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) includingdisposal of excavated earth lead upto 50meters and lift upto 1.5 m,as directed by Engineer-in-Charge.All kinds of soil 17 Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains,pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspitsand the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil 18 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating eachdeposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. 19 Dumping of stone including cost ofstonein Horizontalon level 20 Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 21 Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto/above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 23 Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand) 24 Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level 25 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):First class kail wood 26 Providing and fixing 35mm thickness wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge :First class kail wood 27 Providing and fixing 35mm thickness glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panesincluding ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.First class kail wood 28 Providing and fixing panelling or panelling and glazing in panelled or panelled andglazedshuttersfordoors,windowsandclerestorywindows(Areaof opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. First Class kail wood 29 Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications:(i)Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture 30 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 31 ProvidingandfixingaluminumtowerboltsISImarkedanodized(anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 100mmx10mm 32 150x10 mm 33 Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.125 mm 34 150 mm 35 Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked,with six levers and a pair ofanodized (anodic coating not less than grade AC 10 as per IS : 1868) aluminum lever handles of approved quality with necessary screws etc. complete. 36 15mm Cement plasteron the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand) 37 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) 38 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) 39 Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 gradedstone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.50 mm thick with 20mm nominal size stone aggregate. 40 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2mm thick 41 WallPaintingwithacrylicemulsionpaintofapprovedbrandand manufacture to give an even shade. Two or more coats on new work 42 Finishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied @ 1.43 liter/10sqm over and including priming coat of water exterior paint applied @ 2.20kg/10sqm) 43 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 44 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete 45 Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approvedpaintonoverlappingofsheetscomplete(uptoanypitchin horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.50 mm thick with zinc coating not less than 275 gram/m2 46 Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete.0.50 mm thick with zinc coating not less than 275 gram/m2 47 Providing and fixing flashing of 40cm overall width in plain G.S. sheets fixed with polymer coated J or L hooks, boltsand nuts G.I. limpet and bitumen washers complete, bent to shape and fixed in wall with cement mortar 1:3 (1 cement : 3 coarse sand)1.25 mm thick with zinc coating not less than 350 gram/m2 48 Providing and fixing plained eaves boarding 2nd class kail wood 250x32 mm (nominal size ) 49 Providing and fixing 20mm thick wooden planks ceiling (frame work for base to be paid for separately) with M.S. screws 1class kail wood 50 Providing and fixing specified wood frame work consisting of battens 50x25mm fixed with rawl plug and drilling necessary holes for rawl plug etc, including priming coat complete: Second Class Kail Wood 51 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):First class deodar wood 52 Providing and fixing brass bib cock of approved quality. 15 mm nominal bore 53 Providing and fixing ball valve (brass) of approved quality,High or low pressure, with plastic floats complete (i) 25 mm nominal bore 54 ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc15mm nominal outer dia pipes. 55 20mm nominal outer dia pipes. 56 25mm nominal outer dia pipes. 57 32mm nominal outer dia pipes. 58 Centrifugal monoset self priming pump 1.5KW/ 2HP (CROMPTON) as per the direction of Engineer-In-Charge 59 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 60 Providing, Fixing, Testing & Commissioning uPVC SWR pipes (Type-B) for soil, waste and vent conforming to IS 13592 along with all required fittings liketees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall)and making good the floors, beams and walls with cement mortar where required complete of outer diameter.(Soil/ Waste pipe) (PRINCE ISI MARK) 110 mm dia 61 75 mm dia 62 Fire extinguisher ABC type 6 kg 63 Fire extinguisher CO2 type 2 kg 64 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm 65 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, laid on 20 mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), including grouting the joints with white cement and matchingpigments etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown 66 Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointedwith grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete. 67 Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in :Cement mortar 1:3 ( 1 cement : 3 coarse sand) 68 Extra for half Brick masonry in superstructure above plinth level upto floor V level. 69 Providing and fixing 35mm thicknessglazed shutters for doors, windows and clerestory windows using 4mm thick float glass panesincluding ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws Second class Kail wood 70 Providing and fixing panelling or panelling and glazing in panelled or panelled andglazedshuttersfordoors,windowsandclerestorywindows(Areaof opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Second class Kail wood 71 Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete.250x10 mm 72 200x10 mm 73 Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked,with six levers and a pair ofanodized (anodic coating not less than grade AC 10 as per IS : 1868) aluminum lever handles of approved quality with necessary screws etc. complete. 74 Providing and fixing bright finished brass handles with screws etc. complete : 25 mm 75 100 mm 76 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing andmakingcurvature(whereverrequired)andfittingthesamewith necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab withsuitablearrangementasperapprovalofEngineer-in-charge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 77 Providing andfixingwhitevitreouschinapedestal typewatercloset (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device(handlelever), conformingtoIS:7231,withallfittingsand fixturescomplete, includingcutting and making good the walls and floors whereverrequired: W.C. pan with ISI marked white solid plastic seat and lid. 78 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillartaps,32mmC.P.brasswasteofstandardpattern,including paintingoffittings andbrackets,cuttingand makinggoodthewalls wherever required :White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps 79 Providingandfixingwhitevitreouschinapedestalforwashbasin completely recessed at the back for the reception of pipes and fittings. 80 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm 81 Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 82 Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms. 83 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long,200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms 84 Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 85 Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 86 Providing and fixing unplasticised PVC connection pipe with brass unions:45 cm length 15 mm nominal bore 87 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 88 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: Semi rigid pipe 32 mm dia 89 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required. White glazed fire clay kitchen sink of size 600x450x250 mm 90 Providing and fixing 75mm PVC teeas per the direction of Engineer-In-Charge 91 Providing and fixing 75mm PVC bendas per the direction of Engineer-In-Charge 92 Providing and fixing 110mm PVC bendas per the direction of Engineer-In-Charge 93 Providing, Fixing, Testing & Commissioning uPVC SWR pipes (Type-B) for soil, waste and vent conforming to IS 13592 along with all required fittings liketees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall)and making good the floors, beams and walls with cement mortar where required complete of outer diameter.(Soil/ Waste pipe) (PRINCE ISI 110 mm dia 94 75 mm dia 95 Providing and fixing Geyser 50 Ltr capacity with all complete fitting as per the direction of Enigneer-In-Charge 96 Providing andfixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 97 Providing and laying integral cement based water proofing treatment includingpreparationofsurfacesasrequiredfortreatmentofroofs, balconies, terraces etc consisting of following operations.a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortarofmix1:5(1Cement :5coarsesand) admixedwithwater proofing compound conforming to IS 2645 and approved by Engineer- in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs)c) After two days of proper curing applying a second coat of cement slurryusing2.75kg/sqmofcementadmixedwithwaterproofing compound conforming to IS 2645 and approved by Engineer-in-charge.d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep.e)Thewholeterracesofinishedshallbefloodedwith waterfora minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer- in-charge. With average thickness of 120mm and minimum thickness at khurra as 65 mm 98 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shallbesmooth, rustfree,straight,mitred andjointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.)Powdercoatedaluminum(minimumthicknessofpowder coated 50 microns) 99 Providingandfixing12mmthickprelaminatedparticleboard flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in- charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. 100 Providingandfixingglazinginaluminumdoor,window,ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer- in-charge. (Cost of aluminum snap beading shall be paid in basic item.)With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg / sqm) 101 Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design 102 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III): 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 103 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron,finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 104 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design. In 75x75 mm deep chase. 105 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 106 Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required. 107 Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 108 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 109 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 110 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 111 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required2 x 1.5 sq. mm 112 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 113 Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connection but excluding modular plate etc. as required. 5/6 amps switch 114 3 pin 5/6 amp socket outlet 115 Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required 116 Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required. 117 Supplying & fixing of following way horizontal type three pole and netural, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper bus bar neutral buss bar, earth bar,din bar interconnection nection,powder painted including earthing etc. as required. 4 Way (4+12), (Double door ) 118 6 way ( 4+18), (Double door) 119 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole6/10/16/32 Amp 120 Triple pole and neutral 63 Amp 121 Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).CRCA Sheet Body (Thickness ≥ 0.50 mm)18/22 watt 4 feet LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) 122 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 123 Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS: 374-2019), THD (Total Harmonic Distortion) less than 10% suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers. temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 124 Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire.300mm/12 sweep exhust fan 125 450 mm/18 Heavy duty 126 Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover. 127 Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. 128 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 129 SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. 130 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)200 Amp, 36 KA, FP MCCB ICU = 100% ICS 131 ON Load Change Over Switch FP 100 amp. (Front operated) 132 Aluminium Bus Bar 200 Amp set of 4 strips 18 133 Aluminium Bus Bar 300 Amp set of 4 strips 18 134 Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. 135 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable)95 sq. mm 3.5 core 136 Supplying, Installation, Testing & Commissioning of inverter 2000 VA along-with 2 Nos. long tubular batteries 150 AH and trolley (Metallic) of suitable size. 137 Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy 105 <120 lm/Watt) 100 Watt 138 Supply and erection of Mild steel Swaged tubular pole conforming to IS: 2713-1980 (part I to II) with base plate, The pole shall be made from steel tube & Pipe (IS:1141, Fe 410) including excavation of the pit and filling the same with C.C. of M-20 grade (1:1.5:3) from base plate to 50 cm above ground level, with the help of steel frame not less than 40 cm dia up to 114.3mm outer dia and 50 cm beyond 114.3mm outer dia around the pole. Duly finished with cement plaster, earthing terminals, cable entry with 32 mm dia. B class GI cable sleeves. After eraction pole shall be painted with two coat of red oxide primer and two quote of enamel paint of silver colour as per the direction of Engineer incharge complete as required of following height & designation. All as per pre approved by Engineer in Charge.(ST-410) SP-33. 7.5 Mtr. 139 Add for supply and fixing of Pole OEM fabricated Mild steel Overhang of following size over the existing poles, Overhang shall be painted with two coat of red oxide primer and two quote of enamel paint of silver colour as per the direction of Engineer incharge. All as per pre approved by Engineer in charge.114.3 mm OD x 3.65 mm thickness 140 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.LED Street Light fixture with Minimum lumen output 11225 lm 141 Wiring for supply / sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 3 x 1.5 sq. mm from junction box to top luminary 142 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. HDPE PIPE 63 mm dia (OD-63 mm & ID-51 mm nominal) 143 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 16sq. mm 4 core 144 35 sq. mm 3.5 core 145 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 146 Supply and installation of spike of M.S. rod 20mm dia 3.0mtr long for earthing of (tower/pole) drive into earth by mechanical means sturcture connection the spike with cross arm top hamper PCC pole, lattics tower to earth etc. complete as per technical specification. 147 SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. 148 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type) 63 Amp, 25 KA, FP MCCB ICU = 100% ICS 149 Aluminium Bus Bar 200 Amp set of 2 strips 150 Astro timer with selector switch (to select manual /automatic opration of Ornamental poles) 151 Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set, MCB strips for required Nos. of MCB/MCCBsetc. 152 Supplying and fixing of following rating 240/415 volts C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole upto 6 to 32 Amp 153 MCBSPN FP 40 Amp 154 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 155 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, Ccurve including connections, painting etc. as required. 156 LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120lm/Watt )Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS :10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KVwith Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shallbe confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminum Body including trim 18 Watt 157 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type) 250 Amp, 36KA, FPMCCB ICU = 100% ICS 158 ON Load Change Over Switch FP 200 amp. (Front operated) 159 Aluminium Bus Bar 300 Amp set of 4 strips 160 Aluminium Bus Bar 400 Amp set of 4 strips 161 Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. 162 Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required.(Copper winding) 1 HP 163 Supplying, installation, testing and commissioning of1.5 Ton Inverter type SplitACs (copper)Hot/ Cold (all weather) type of minimum capacity following Specification as detailed below. 1. Should be of inverter type2. Cooling capacity (in Tr): 1.53. BEE Star rating: 34. Maximum local temperature: 52 C5. Rated cooling capacity (BTU/hr.): 19000 or above6. Condensing coil: 100% Copper with grooved copper tubes7. Electrical input, 220 V ± 30/50Hz/Single Phase8. Noise level (indoor unit): = close to 35 dB9. Compressor type: rotary or any other suitable technology10. Refrigerant type: R-3211. Anti-Corrosive Coating for the outdoor unit: Bule Fin/Gold Fin or equivalentc12. Compressor Warranty: 10 years13. PCB Warranty: 5 year14. Total System Warranty: 1 year15. Minimum noise level of the indoor unit should be around 28 dB (A)16. Should have air filtering mechanism for removing dust17 Supplier has to include brochure of the quoted modelEach unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features.The job includes Repairs made to wall where ever as required. 164 Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary.Warrantee.:2 Years from the date of installation.4 KVA 165 Supplying, fixing & commissioning of Storage Water Heater (Geyser)of following capacity along with PVC Pipes etc as required.50 Ltr 166 Earth work in excavation by manual means in trenches for foundations, drains,pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspitsand the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:All kinds of Soils @ 70% 167 Ordinary Rock @ 30% 168 Dry random rubble masonry with hard stone in foundation and plinth: Without bond stone. Nallah 169 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) includingattachedpilasters,columns,piers,abutments,pillars,posts,struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 170 Soil Investigation/Survey of land area for fencing/StructuralDesignduly vetted by GCET Jammu /I.I.T/DIQC Jammu/NIT 171 Carriage ofSandfrom Source to site of work by Mechanicaltransport including loading /Unloading completefor an avg distance of 110 km by MT 172 Carriage ofStone aggregate below 40mm from Source to site of work by Mechanicaltransport including loading /Unloading complete for an avg. distanceof 10 km by MT 173 Carriage ofStone aggregate above 40mm from Source to site of work by Mechanicaltransport including loading /Unloading complete for an avg. distanceof 10 km by MT 174 Carriage ofStonefrom Source to site of work by Mechanicaltransport including loading /Unloading complete for an avg. distanceof 10 km by MT 175 Carriage ofBrickfrom Source to site of work by Mechanicaltransport including loading /Unloading complete for an avg. distanceof 110 km by MT 176 Disposal of excavated earthfor an avg. distanceof 10km by MT

Key Value

Document Fees
INR 6000 /-
EMD
INR 850160.0 /-
Tender Value
INR 4.25 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail