| 1 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 2 | 1:3:6 (1Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | 1:4:8 (1Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 6 | Suspended floors,roofs,landings,balconies and access platform |
| 7 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete above plinth level. |
| 8 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 9 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 10 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 11 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 12 | 300x16 mm |
| 13 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 14 | 200x10 mm |
| 15 | 150x10 mm |
| 16 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 17 | 125 mm |
| 18 | 100 mm |
| 19 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 20 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 21 | Electric resistance or induction butt welded tubes |
| 22 | Cement concrete flooring 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 23 | 40 mm thick with 20 mm nominal size stone aggregate |
| 24 | Providingand fixingplainmultipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). |
| 25 | 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 :2000 |
| 26 | ProvidingandfixingofPre-coatedcolourormillfinishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]. For colour, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50 mm with 3 mm thick EPDM seal and SS plain washer complete: |
| 27 | Precoated/mill finish aluminium Ridges plain (500- 600mm) |
| 28 | 12 mm cement plaster of mix: |
| 29 | 1:4(1 cement: 4 fine sand) |
| 30 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour: |
| 31 | New work(twoormorecoats)over andincludingwater thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 33 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 34 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: |
| 35 | Two or more coats on new work |
| 36 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand andmanufacturerincluding applying additional coats wherever required to achieve even shade and colour |
| 37 | Old work (one or more coats) |
| 38 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 39 | One or more coats on old work |
| 40 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 41 | Old work (Two or more coat applied @ 1.67 Itr/ 10 sqm) on existing cement paint surface |
| 42 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 43 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 44 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 45 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 46 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 47 | Of area beyond 3 sq. metres |
| 48 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : |
| 49 | Of sectional area 40 square centimetres and above |
| 50 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 51 | G.S. Sheet |
| 52 | Asbestos Cement sheet |
| 53 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 54 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 55 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position |
| 56 | Superiorhard woodCat-II(A) |
| 57 | Providing and fixing 35mm thick panelled, glazed or panelled and glazed shutters for doors including oxidised mild steel butt hinges with necessary screws with superior hardwood category No. II(A)including panelling with 12mm thick marine plywood (BWR) confirming to relevent specification with wooden cleats and block and as directed by Engineer in charge. |
| 58 | Providing and fixing35mm thick glazed shutter for windows with superior hard wood category II(A)using 10 kg/sqm (4mm) thick float glass panes including oxidised M.S. butt hinges with necessary screws etc. complete. |
| 59 | Providingandfixingin position eaves or faciaboardwith PVC Board (30cmwidth & 19 mm thick) along with necessary fixing arrangements including nutsandbolts and drilling holesetc complete. |
| 60 | 19 mm thick |
| 61 | Providing and fixing pre-painted galvalume (PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everesrt Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equalavent(size,shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with aluminium zinc coating 150 grams per sqm as perIS : 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping aluminium screws (Xylan) of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |