Balance Work At Iti Sahiba Block Balachaur In Distt Sbs Nagar-Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screwsor with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steelmscrews, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) : 2 (b) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required 3 Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work. 4 Providing and fixing 12mm thick prelaminated particle board flat pressed threelayerorgradedwoodparticleboard conformingtoIS:12823GradelTypell, in paneling fixed in aluminum doors, windowsshuttersandpartitionframeswith C.P. brass / stainless steel screws etc. complete as per architectural drawings anddirectionsofEngineer-In-Charge.Pre laminated particle boardwith decorative lamination on Both side 5 Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminum snap beading shall be paid in basic item) 6 Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973, Commercial with elm or gurjan facing on both Sides with laminated core and lipped edges:-35mm Thick 7 Providing and fixing double action hydraulic floor springof approved brand andmanufacture IS : 6315marked, for doors including cost of cutting floors as required, embedding in floors andcover plateswithbrass pivot and singlepiece MSsheet outer boxwithslideplateand with stainless steel cover plate etc. completeasper thedirectionofEngineer in-charge 8 Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppersandscrewetc. for these fittings (Excluding sliding bolt) for shutter area above 0.50 sqm 9 Providing and fixing aluminium sliding door bolts ISI marked anodized 10 Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on woodwork, metallic or plastered,concrete surface to give an even shade.(entry gate) 11 Earthwork in excavation in foundations trenches etc. inallkindsofsoilwherePick-Jumperworkis not involvedandnotexceeding 2.0metresdepth including dressing of bottom and sides of trenches, stacking theexcavatedsoil clear from the edge of excavation and subsequent filling aroundmasonryin15cm, layerswithcompaction includingdisposal of all surplussoil asdirected within lead of 30 metres. 12 cement concrete 1:8:16 with 40 guage stone aggregate using mechanical mixer. 13 first class brick work laid in cement sand mortar 1:5 in foundation and plinth. 14 Base Course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling (using mechanical mixer for making of material) 15 conglomerate floor 40mm thick cement concrete topping 1:2:4 (using mechanical mixer for mixing of material) 16 12.5 mm thick cement plaster 1:5 complete in all respect as per specification, drawing and to the entire satisfaction of engineer-in-charge 17 Cement concrete 1:4:8 With stone ballast 40mm gauge 18 Providing and laying 60mm thickcement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish by strong vibratory process or with vibrohydroiccompactrors machine and of approved size and design / shape laid in ordinary Grey Colour and pattern over and including 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer in Charge for Light Traffic Areas such as Pedestrain plazas, shopping complexes, ramps, car parks, office driveway, housing colonies, office complexes, rural roads with low volume traffic, farm houses, beach sites, tourist resorts, local authority footways, residential roads etc. 19 Plain cement concrete M-20 grade precast kerb 250mm high with bottom width 165 mm and top width 115mm fix in position including carriage to site of work complete as per technical clause 408 of MORT&H specifications. 20 Applying primer coat with cement primer in all shade on newly plastered or concrete exterior surface 21 Painting two or more coats excluding primer coat with synthetic enamel paint in all shades of wood work, metalic, pastered,concrete surface to give an even shade. With special quality paint 22 Supplying and fixing rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together through their entire length and jointed together, at the end, by end locks, mounted on specially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exact size of opening where rolling shutter is to be fixed) 23 Providing and fixing 4mm thick 300mmwide Asbestos sheet with gatties and screw on vertical expansion joints one side fixed and one side fixed with slotted holes complete in all respect as per specifications.