Re-Development Of Bharion Ji Temple Area- 1 CIVIL WORKS 2 Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 mOrdinary rock 3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCholoropyriphos / Landane E.C. 20% with 1% concentration 4 Providing and laying in position cement concrete of specified grade M10 (1:3:6) excluding the cost of centering and shuttering - All work up to plinth level: 5 Providing and fixing shuttering (using plywood) in position with necessary centerings, shuttering, bracings, propping etc. and removing the same after the specified periods for all types of shuttering for all plain and reinforced cement concrete works including all chamfers, splays, keys, wedges, nails, brackets, cutting holes for embedded steel/pipes and applying waste oil on shuttering surfaces in contact with concrete, all materials, tools, plant and labour complete 6 Foundations, footings, bases of columns etc. for mass concrete 7 Suspended floors, roofs, landings, balconies and access platform 8 Shelves (Cast in situ) 9 Lintels, beams, plinth beams, girders, bressumers and cantilevers 10 Columns, Pillars, Piers, Abutments, Posts and Struts 11 Arches, domes, vaults up to 6 m span 12 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth levelThermo-Mechanically Treated bars of grade Fe-500D or more 13 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 14 Providing and laying in position M-25 grade concrete for reinforced cement concrete work, using fly ash and cement content as per approved design mix, and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-chargeNOTE-Cement content considered in this item is @ 330 kg/cum.Excess/less cement used as per design mix is payable/recoverable separatelyAll works upto plinth level 15 Concrete of M25 grade with minimum cement content of 330 kg /cum 16 Concrete of M30 grade with minimum cement content of 350 kg /cum 17 Concrete of M25 grade with minimum cement content of 330 kg /cum 18 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth inCement mortar 1:6 (1 cement : 6 coarse sand 19 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes inCement mortar 1:6 (1 cement : 6 coarse sand) 20 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) 21 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 22 Providing and fixing 20 mm thick gang saw cut, mirror polished, pre-moulded and pre-polished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levelsMakrana White Marble Stone 23 Providing edge moulding to 16 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-ChargeMarble work 24 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry, including rubbing and mirror polishing complete withMakrana white Ist quality 25 Providing and fixing machine cut, mirror/ eggshell polished , Marble stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern ,groove wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge20 mm thick Makrana white Ist quality 26 Stone Cladding on Columns-Main 27 DOME 2 MANDAP 28 SHIKHAR 1 DOME 1 29 Extra for providing opening of required size and shape for wash basin/ kitchen sink inkitchen platform, vanity counters and similar location in marble/granite / stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 30 (a) at Column Base(i) 650 mm dia column x 325 mm high 31 (b) at Column Capital(ii) 650 mm dia column x 325 mm high 32 Providing Balusters of Size 140x140 mm in Makrana White marble stone for inserting Stone Railing in desired pattern up to 1300 mm height including machine polishing to edge to give high gloss finish etc. complete as per design approval by Engineer-in-Charge in CNC Machines 33 1100 mm High 34 1300 mm High 35 Providing Full round moulding to 20 mm thick Makrana White marble stone including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 36 Providing half round moulding to 20 mm thick Makrana White marble stone including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 37 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.-600x300 mm (Minimum) 38 Extra for pre finished nosing in treads of steps of Makrana White Marble Staircases 39 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)25 mm thick 40 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 41 Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand):Light shade pigment using white cement 42 Providing and laying HPL Flooring in Connection Corridor as per approved sample 43 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (Mild Steel-350 MPA) 44 Providing and fixing stainless steel (Grade 304) work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and with polishing and Consumables of approved including welding and bolted with special shaped washers etc. complete. 45 Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame, concrete/ masonry, etc. as per direction of Engineer-in-charge.10 x 80 mm 46 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 47 Providing and fixing roofing “Smart Deck 51 orequivalent Supply of LYSAGHT Structural Decking SMARTDEK™ 51 W DECK Profile in Galvanized Steel shall be minimum 1.00 mm thick BMT550 MPa yield strength as per IS 513 with a crest height of51mm at a pitch distance of 316mm c/c having a cover width of960mm. 3mm deep and 19 mm long embossment on either side of webs which are diagonally opposite to each other to provide the mechanical interlocking between the steel and concrete ensuring adequate composite action between steel and concrete. The panel shall have v” shape of 10mm deep on rib and pan as a stiffener and male and female interlocking at side lap. The deck panel shall be coated with hot dipped zinc with coating mass of Z275 gm per sqm on both sides as per IS 277 or approved equivalent as per direction of Engineer in charge. The Steel conforms to IS 1397 and BSEN10147:2000. The profile comprises of intermediate male & female ribs for every interlocking of side lap joints.”. (Structural steel like Beam, column, joists etc., Shear Studs & concrete of different grade as per design will be paid separately). 48 Supplying and installing in position Shear Stud and 19mm x 105mm LAW Shear Studs etc. complete as per approved make 49 12 mm cement plaster of mix:1:4 (1 cement: 4 fine sand) 50 Extra for providing grooves in plaster of size 12 mm x 6mmPlaster Surface area 51 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 52 6 mm cement plaster of mix : 1:3 (1 cement: 3 Fine sand) 53 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 54 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour:New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 55 Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 56 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 57 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 58 Finishing walls with textured exterior paint of required shade:New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 59 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. completeOn steel work 60 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. (Toilet + Balcony)The contractor shall have to furnish ten years guarantee to maintain the Water Proofing area. 61 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:With average thickness of 120 mm and minimum thickness at khurra as 65 mm 62 Providing and fixing Makrana White marble 18mm kalash on external sides of Dome of Temple of required size and of approved quality including polishing, finish all complete as per approved drawing & direction of Engineer-in-Charge. Shikhar 63 Providing and supplying injection adhesive HILTI HIT-HY 200 R / FISCHER/ WURTH or equivalent male Safe Set System for rebar fixing in dry/ damp conditions for dia of 10mm to 25mm. The system should be made of two components consisting of resin and hardener in 5:1 ratio as a soft foil pack of 330/500ml. The foils should be soft foils for less wastage & being environment friendly. The chemical should have certification/ approvals/ test reports from/ for ETA/ TR023, LEED, corrosion resistant behaviour (SGK), fire rated, water tightness. The installation (drilling hole to the required depth by rotary hammer TE-YD hollow drill bit and filling above mentioned mortar with standard dispenser before inserting rebar) and the setting instructions should be strictly followed as per the manufacturers recommendations. Rate shall be inclusive of pull out test as recommended by the consultant.Note:- Numbers of bar can be changed as per actual. 64 8mm dia & depth of 80mm (10D) 65 10mm dia & depth of 100mm (10D) 66 12mm dia & depth of 120mm (10D) 67 16mm dia & depth of 160mm (10D) 68 20mm dia & depth of 200mm (10D) 69 25mm dia & depth of 250mm (10D) 70 Providing and applying bonding agent Nitobond EP which shall be a solvent free epoxy based two component resin system. The bonding agent shall be applied by brush & should remain in tacky state after application for a minimum period of 5-6 hrs at 20 deg C & 2-3 hrs at 30 deg C. The product shall achieve 50 N/mm2 compressive strength, 20 N/mm2 tensile strength, 35 N/mm2 flexural strength and 10 N/mm2 shear strength as per BS 6319 standards. The adhesive bond to the concrete substrate shall exceed the tensile strength of the host concrete, etc complete. It shall not be used in the influence zone of the Fosroc Galvashield anodes in case of installation in the periphery of patch. No bond coat shall be applied in case of installation in a grid pattern. 71 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge 72 Nominal concrete 1:3:6 or richer mix (including equivalent design mix) 73 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge 74 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge. 75 Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work 76 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar 77 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured):From brick work in cement mortar (1000 Nos.) 78 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead 79 Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead 80 Demolishing mud phaska in terracing and disposal of material within 50 metres lead. 81 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. 82 Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. 83 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe - 40mm dia 84 Providing & Supplying rain water spouts 85 100 mm Dia x 400 mm Length 86 160 mm Dia x 400 mm Length 87 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 88 Supply, Fabrication & Installation Clear Laminated lass.13.52(6mm+1.52+6mm) with Aluminium Framing(75X75X2.48mm) with Norton Tape & Weather Silicon etc. 89 Providing Cornices in Concrete including finishing with cement sand Plaster to edge to give smooth finish etc. complete as per design approved by Engineer-in-ChargeCornice at roof level =700X380 mm 90 CARRIAGE OF MATERIALCarriage of Material from source to site of work 91 Cement for an average lead of 67 km by MT + 2 km by HL 92 Stone Aggregate for an average lead of 37 km by MT + 2 km by HL 93 Sand for an average lead of 57 km by MT + 2 km by HL 94 Structural Steel for an average lead of 12 km by MT + 2 km by HL 95 ELECTRIC WORKS 96 Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core wire in surface / recessed PVC conduit, with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core wire etc. as required.(Wire Make: Finolex / RR / Polycab / KEI), (Conduit Make: AKG / BEC / Finolex / Polycab / Precision), Switches Make : Legrand / ABB / Clipsal/ Opale / RR / Polycab / Indo Asian-Elvira) Group - C 97 Wiring for group controlled light point/fan point/exhaust fan point/call bell point (without independent switch etc.)with 1.5 sqmmFRLS PVC insulated copperconductor single core wirein surface / recessed PVCconduit, with modular switch and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core wire etc. as required.Group C 98 Wiring for twin control light point with 1.5 sqmm FRLS PVC insulated copper conductor single core wire in surface/recessed PVC conduit, 2 way modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core wire etc. as required. 99 Power plug wiring in PVC conduit (2 x 4 sqmm.) :-Wiring for light/power plug with 2 x 4 sqmm. FRLS PVC insulated, copper conductor single core wire in surface / recessed PVC conduit along with 1 x 4 sqmm FRLS PVC insulated copper conductor single core wire for loop earthing as required. 100 Circuit / Sub main wiring in PVC conduit:-Wiring for circuit / submainwiringalongwith earth wire withthe following sizes of PVC insulated, copper conductor single core wire insurface/ recessed PVC conduit as required. 101 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire 102 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. Earth wire 103 2 x 4 sq.mm. + 1 x 4 sq.mm. Earth wire 104 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire 105 2 x 10 sq.mm. + 1 x 10 sq.mm. Earth wire 106 2 x 16 sq.mm. + 1 x 16 sq.mm. Earth wire 107 Supply and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required: 108 20 mm. 109 25 mm. 110 32 mm. 111 40 mm. 112 Supplying and fixing following size/ modules, GI Box alongwith modular base & cover plate for modular switches in reccess etc as required. 113 75 mm x 75 mm (1 Module or 2 Module) 114 125 mm x 75 mm (4 Module) 115 125 mm x 125 mm (8 Module) 116 200 mm x 150 mm (12 Module) 117 Supplying and fixing following Modular Base & cover plate on existing modular metal box etc as required. 118 1 Module or 2 Module 119 4 Module 120 8 Module 121 12 Module 122 Supplying and fixing suitable size GI Box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A Modular Socket outlet and 5/6 A Modular Switch, Connections etc as required. 123 Supplying and fixing suitable size GI Box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 & 15/16 A Modular Socket outlet and 15/16 A Modular Switch, Connections etc as required. 124 Supplying and fixing 3 pin, 5A Ceiling rose on the existing junction box/ wooden block including connections etc. as required. 125 Installation, testing & Commissioning of Ceiling Fan, Including wiring the down rods of standard length (upto 30cm) with 1.5 sqmm FRLS PVC insulated, copper conductor, single core cable etc. 126 Installation of Exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 127 Supplying and fixing following modular switch/ socket on the existing modular plate & Switch Box including connection but excluding modular plate etc. as required. 128 5/6 A Switch 129 2-Way 5/6 A Switch 130 15/16 A Switch 131 3 pin 5/6 A Socket outlet 132 6 pin 15/16 A Socket outlet 133 Telephone socket outlet (RJ-11) 134 TV antenna socket outlet 135 Supplying and fixing Two Module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 136 Supplying and fixing modular Blanking on the existing modular plate & switch box excluding modular plate as required. 137 Supplying and drawing of UTP 4 pair Cat-6 LAN cable in the existing surface/ recessed Steel/PVC conduit as required.1 Run of Cable 138 Supplying and fixing suitable size GI Box with modular plate and cover plate on surface or in recess, including providing and fixing 2Nos. 3 pin 5/6 A modular socket outlet and 2Nos. 5/6 A Switch connections etc. as required. 139 Wiring including termination for the first light points controlled by MCB in distribution board (Cost of MCB taken separately) with 2x2.5 sq.mm. PVC insulated copper conductor FRLS wires of 1100 Volts grade in concealed/exposed PVC conduits and 1.5 sqmm. earth wire. 140 Same as above but LOOP POINT i.e. wiring of point looped from first point with 2x1.5 sq.mm. PVC insulated copper conductor FRLS wire of 1100 volt grade in concealed / exposed PVC conduits and 1.0 sqmm earth wire 141 Providing 20 amp control switch and 6 pin 20 amp socket at different locations including connecting conduit and circuit by 2x4 + 2.5 sq mm copper wires. (For Geyser) 142 Providing & Fixing of modular plate type white RJ 45 CAT 6 Data outlet / information outlets on 1.0 mm tk G.I. Switch control boxes, with cover plate, grid plate, screws, etc with connections as required. 143 1 nos. RJ 45 Data Outlet 144 2 nos. RJ 45 Data Outlet 145 Supply and drawing following pair, 0.5 sq.mm. FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface / recessed conduit as required.2 Pair 146 Supply and drawing of co-axial TV cable RG-6 grade, 0.7 mm. Solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed conduit as required. 147 Distribution Boards and Circuit Breakers 148 Supplying and fixing following way, single pole and neutral, sheet steel, SP MCB distribution board consumer unit , 240volts, on surface / recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections and powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator)16-Way (2 + 16) Double door 149 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, TPN MCB distribution board, 415 volts, on surface /recess,completewithtinnedcopper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators).8 way (8 + 6 + 24), Double door 150 Supplying and fixing following ways surface / recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps. tinned copper busbar, common neutral link, earth bar, din bar for mounting MCBs, (without MCBs and incomer) as required.8 way with 100 Amps MCCB as incomer 151 Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C series, miniature circuit breaker (MCB)suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 152 Single pole 153 Single pole and neutral 154 Supplying & fixing single pole, blanking plate in the existing MCB DB complete etc. as required. 155 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V C curve DP MCB complete with connections, testing and commissioning etc. as required. 156 Supplying and fixing following rating, double pole, (single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a sensivity current upto 300 miliampere in the existing MCB DB complete with connections, testing and commissioning etc. as required:40 amps. 157 Miscellaneous 158 S/F of hexagonal fan box with hexagonal side of approx. 80 mm.in length fabricated from 14 SWG G I. sheet incorporating with 12 mm. dia. G.I. round bar duly bent for supporting fan hanger and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour, T&P etc. for proper completion of work. 159 SUPPLY OF LIGHTING FIXTURES Supply of recess / surface, round / square, ceiling mounting LED Light fixture having Powder coated die cast aluminium housing with heat sink, glare free diffuser with uniform light distribution, PF above 0.9, efficacy above 90 lm/watt, pre wired with constant current LED driver set, suitable for 1 phase, 240 V, 50 Hz, IP 20 complete in all respects. (colour temerature 3000oK / 4000oK / 6500oK - to be confirmed before supply)Make: Philips, Wipro, Bajaj, Legaro, RR Kabel) 160 20 watt LED MIRROR LIGHT 161 15 watt LED DOWN LIGHT 162 40 W UP LIGHT - ARUCUS FLOOD LIGHT 163 45 W POST TOP LIGHT 164 50W LED SMD FLOOD LIGHT 165 Supply of surface, wall / ceiling mounting LED T5 / T8 Tube Light fixture having Powder coated die cast aluminium housing with heat sink, PF above 0.9, efficacy above 90 lm/watt, pre wired with constant current LED driver set, suitable for 1 phase, 240 V, 50 Hz, IP 20 complete in all respects. (colour temperature 3000oK / 4000oK / 6500oK - to be confirmed before supply)Make: Philips, Wipro, Bajaj, Legaro, RR Kabel, Crompton)20 watt LED T5 / T8 Tube Light fixture (1200 mm long) 166 ERECTION OF LIGHTING FIXTURESThe Fixing and testing of lighting fixture shall include connection with wire of required length complete with all accessories including screws, nuts, wooden cleats, making hole in wall or ceiling and making good the same as required. 167 Recess / surface, round / square, ceiling mounting LEDLight fixture 168 Surface, wall / ceiling mounting LED T5 / T8 Tube Light fixture 169 SUPPLY OF FANS AND EXHAUST FANS 170 Supply of AC230/250 volts, 50 HZ energy efficient ceiling fan with standard down rod, blades, 2 nos. caps etc.Complete(Make: Bajaj / Crompton / Havells / Ploycab / RR)1200 mm sweep (BEE 5 Star) 171 Supply of AC230/250 volts, 50 HZ exhaust fans including providing nuts, bolts, mounting frame and other accessories etc.complete (Make: Bajaj / Crompton / Havells)300 mm sweep 900 rpm (BEE 5 Star) 172 Supply of 400 mm sweep AC 230/250 volts, 50 HZ wall mounting revolving fan with brackets etc. complete (Make: Bajaj / crompton / havells)Total for Sub Head-C 173 SUPPLY OF DIESEL GENERATING SET WITH AMF PANEL 174 Supply, testing and Commissioning of Silent type Diesel Generating Set with AMF Panel at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, 0.85 load factor including circuit breaker for isolation, sound proof acoustic and weather proof enclosure, residential type silencer (as per CPCB norms-4) fabricated out of CRCA sheet of 16 SWG thickness with 9 tank pretreated before powder coating with ventillation system complete in all respects comprising of the followingOEM - Jakson Ltd (Cummins) / Jakson & Co. (Kirloskar) / Sterling / TIL / Kohler {Engine - Cummins, MTU, Mitsubishi-Japan and Caterpillar, Kirloskar} {Alternator - Stamford / Leroy Somer / Greaves / Marathon}Diesel Engine - Diesel Engine suitable for driving alternator of above rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for above output of alternator at 40oC, 50% RH & at 210 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of prime continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, mechanical governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system.Instrument Panel - Engine mounted Instrument Panel fitted with and having digital display for followings: Start stop switch with keyWater temperature indicationLubrication oil pressure indication.Lubrication oil temperature indication.Battery charging indicationRPM indicationOver speed indicationLow Lube oil trip indicationEngine hours indicationAlternator- Synchronous Alternator of above capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 210 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of prime continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for cable termination as required.Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer.Inbuilt Fuel tank of standard capacity complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, fuel transfer system for automatic fuel refilling system with pump, piping, valves, level indicators etc. complete.Daily service Fuel tank of 990 liters capacity fabricated out of 2 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, provision for fuel transfer system, level indicators and all standard accessories etc. as required.Exhaust Silencer - Exhaust manifold with residential silencer.The D G set should be supplied with required hardware for AMF Panel.Starting system - 12 Volt DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with 12 Volts suitable nos. lead acid type batteries of suitable AH.Ventilation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications.A M F Panel -Fabricating, Installing, Testing & Commissiong of automatic mains failure control including auto by-pass suitable for silent type DG set complete with relays, timers set of CTs for metering & projection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH , KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following: TP+N MCCB of suitable rating with AC1 contactor/ MDO / EDO cradle type 3 position ACB with electronic release for O/C & E/F and shunt trip.Auto/Manual/Test/Off selector switchD G Start / stop push button, emergency stop push button, 2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay.3 sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for meteringEnergy analyser unit to indicate current voltage frequency power factor and KWHIndicating lamps for Mains ON/OFF, DG supply ON/OFF, DG running, DG fails to start.Fuse for instrumentsBattery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.Main supply failure monitorSupply failure timerRestoration timerControl unit with three impulse automatic engine start/stop and failure to start lockout.Impulse counter with locking and reset facility.ON/OFF/Control circuit switch with indicatorAudio/Vedio annunciation for (i) High water temperature,(ii) Low lubricating oil pressure,(iii) Engine over speed,(iv) Engine fails to start, (v) Full load/ maximum load warning15 KVA / 12 KW 175 Supply of L.T. Panel 176 Design, manufacture, supply inspection, handling, assembling, affecting proper connections, testing and commissioningof 16 SWG CRCA sheet steel fabricated cubical type L.T. Panel, floor mounting, dust & vermin proof, front operatedconstruction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottomremovable gland plates, as required, double compression type cableglands,earth bus, hinged and lockable doorsto achieve dust and vermin proofcomplete with all inter connectionssmall wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623. The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable or Aluminium Bus Duct as required.The incoming MCCB shall be thermal-magnetic based with inbuilt O/L & S/C release with E/F protection.All MCCBs shall be Ics = 100% Icu, Thermo-magnetic type with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. The breaking capacity specified is Ics value. All outgoing MCBs shall be C type with 10 KA breaking capacity.(Switchgears Make:ABB / L&T / Siemens / Schneider)INCOMER FROM DG AMF PANEL1 no. 40 AMP FP MCCB of 25 KAProtection releases / relays, Metering & Accessories for incomers0-500 volt range voltmeter with selector switch(P.T. connected)Class 1.0 accuracy 15 VA burden C.T. operated ammeter with selector switchBUS BARSBUS BAR:200 AMP, 500 Volts, 3 phase 50 HZ FP (with 100% neutral) high conductivity electrolytic Aluminium bus bar with conductivity of min 57 to 58% of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 1.00 sq mm / amp.The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above ambient temperature.OUT GOINGS:5 nos 40 AMP DP MCB (10 KA) 177 Installation of Silent Type D G Set - The installation of D G Set will include receiving, storing, handling, installation, testing and commissioning, affecting proper connections with the power and control cables, coordination with the D G Set supplier, civil contractors etc complete in all respects. The small items / accessories required for erection of D G Set will be included in the rates. (The civil work for the D G Set foundation will be separate).15 KVA 178 INSTALLATION OF LT PANELThe installation of panel will include receiving, storing, handling, installation, testing and commissioning, affecting proper connections with the power and control cables, coordination with the Panel manufacturers, civil contractors etc complete in all respects. The small items such as nut, bolts and other accessories required for erection of panel will be included in the rates.LT Panel 179 G.I.EARTHING 180 Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal / coke and salt as required. 181 Providing and fixing 25 mm x 5 mm GI strip at 0.50 M. below ground as strip earth electrode, including connection/terminating with GI nut, bolt, spring, washer etc as required. (jointing shall be done by overlapping and with two sets of GI nut bolt & spring washer spaed at 50 mm). 182 Providing and fixing 25 mm x 5 mm.G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with GI nut, bolt, spring, washer excavation and re-filling etc as required 183 Providing & fixing 25mm x 5mm G.I. strip on surface or in recess for connections etc. as required. 184 COPPER EARTHING 185 Earthing with copper earth plate 600mm x 600 mm x 3 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 m long etc, with charcoal / coke and salt as required. 186 Providing and fixing 25 mm x 5 mm copper strip at 0.50 M. below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc as required. (jointing shall be done by overlapping and with two sets of brass nut bolt & spring washer spaed at 50 mm). 187 Providing and fixing 25 mm x 5 mm.Copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc as required 188 Providing & fixing 25mm x 5mm copper strip on surface or in recess for connections etc. as required. 189 LT CABLES AND CABLE TERMINATIONSupply of ISI marked Laying and testing of aluminium / copper conductor cable PVC / XLPE insulated armoured, served, sheathed 1100 volts grade. On surface the cable run shall be fixed by GI clamps etc. of suitable size or on existing cable tray or insideexisting RCC / HDPE DWC pipe complete in all respect .The armouring of the cable shall be properly connected with the earth conductor including fixing of palm or pin type copper tin plated cable socket (lug) / end terminations to the cable leads, insulating with tape and making connections with brass / nickle plated flame proof double compression glands, providing cable tags complete in all respect upto the satisfaction of Engineer-in-charge. (The supply of terminations and glands shall be under separate item) (Make: Universal (Satna) / CCI / Nicco / Finolex / Polycab / Skytone / RR 190 10 sqmm 4 core CU. 191 16 sqmm 4 core CU. 192 Supply and making end termination with brass double compression glands and Al Lugs for following size of PVC / XLPE insulated armoured, Al. conductor cable of 1.1kV grade as required. 193 10 sqmm 4 core CU. 194 16 sqmm 4 core CU.