}

Tender For Electrification Of Inspection Quarter, Power House And Staff Quarters At Kanhoji Angre Island Lighthouse Under Mumbai Directorate., Raigad-Maharashtra

Tender Notice

51673015
Corrigendum : Tender For Electrification Of Inspection Quarter, Power House And Staff Quarters At Kanhoji Angre Island Lighthouse Under Mumbai Directorate.
Tender
Indian
Maharashtra
Raigad
30-10-2025

Tender Details

Tender For Electrification Of Inspection Quarter, Power House And Staff Quarters At Kanhoji Angre Island Lighthouse Under Mumbai Directorate.; 1 Supplying and fixing of 25mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2 Supplying and fixing of 38/40mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 3 Supplying and fixing following size/modules, GI box/Surface Plastic box alongwith modular base & cover plate for modular switches in recess etc.as required. 4 2 Module 5 3 Module 6 6 Module 7 8 Module 8 12 Module 9 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc.as required. 10 5/6 A switch 11 5/6 A two way switch 12 15/16 A switch 13 3 pin 5/6 A socket outlet 14 6 pin 15/16 A socket outlet 15 TV antenna socket outlet 16 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 17 Supplying and fixing brass batten/Angle holder including connection etc. as required. 18 Supplying and fixing 2/3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 19 Installation, Testing and Commissioning of wall bracket/ceiling fitting of all sizes and shapes containing upto two GLS/CFL/LED lamp per fitting, complete with all accessories including connections etc. as required (For Bulkhead, fitting must by carried out on wooden patia) 20 Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required. 21 Installation, Testing and Commissioning ofexhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (Up to 450 mm sweep). 22 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/recessed steel/PVC conduit as required. 23 2 x 1.5 sq mm( For Tube light & Lamp Holder). 24 3 x 1.5 sq mm( For Fan & Bulkhead Light). 25 3 x 2.5 sq mm . 26 3 x 4 sq mm 27 3 x 6 sq mm 28 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 29 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq mm. 30 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) 31 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board,240V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections,powder painted including earthing etc. as required (But without MCB/RCCB/Isolator). 32 6 Way, Double Door 33 8 way, Double door 34 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA,C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single pole 35 Supplying and fixing 63 A rating, Double pole,240V,Isolator in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 36 Supplying and fixing 63A rating, Double pole, ( phase and neutral), 230 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc.as required. 37 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (02 Nos AC) 38 Earthing with Copper earth plate 600 mm x 600 mm x 3 mm thick includingaccessories,and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. 39 Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling etc., as required. 40 Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum), 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with remote. 41 Supplying, Installation, Testing, Commissioning of 100LPD capacity Evacuated Tube Collector (ETC) Solar Water Heating System comprising of all glass ETC tube absorber. The inner layer of absorber shall be of solar selected absorbing coated tube, Vacuum jacket, cover glass tube, getter and getter mirror surface, as per IS 16543. The system shall have temperature gauges, strainer, 2 nos. water meters, Suitable capacity cold and hot water tank, all MS structure for installation including suitable electric control panel complete with control and power wiring, necessary pluming including piping for cold and hot water line between tank and solar water system, water heater and thermostat including non-return valve, float valve and other valve etc. as required. The various component shall have following specification.1. The Absorber area i.e. the number, dimension and thickness of solar evacuated tube as per IS:16544 clause 5.4 and IS: 16543 clause 4.22. Boro Silicate Glass 3.3 for cover plat as per ISO: 3585.3. The material for three target coating shall be aluminum nitrate, aluminum nitrate stainless steel and copper multi layer selecting coating as per IS:16543.4. Manifold shall be of Mild steel section with PP coating and Inner material shall be of SS 304.5. Recommended operating pressure:10 Bars.6. The capacity of hot water tank shall be minimum 1.5 times the rated capacity system. Inner Material shall be Stainless Steel SS 316 b) as per IS 1730 grade SS304-2B (22SWG). The hot water tank shall be insulated with high density injected PUF insulation 50 mm thickness between inner and outer tank. Tank stand shall be of mild steel and shall bedesign to withstand wind velocity of 100km/hours(minimum) or more as per site.7. Suitable nos. ISI Marked electrical heaters along control panel, with suitable breaker, all protections, and all safety provisions so as to achieve 60 C temperature rise in an hour. The range of thermostat shall be upto 80 C. 42 Supply of 24W LED Street Light with AC power factor at full load ≥ 0.90,The luminaire protected against surges and transients, Internal - Minimum 4KV,Efficiency ≥85%,IP66 rating Protection. 43 Supply of 12W 6 Inch LED Round type Recess Downlight. Chip Efficacy (in lm/watt)->/=130,Input Operating Voltage Range-140V to 280 V at 50 Hz AC,Colour temperature (in K) (+/- 500 K)- 6000K 44 Supply of 12V/900VA Sine wave inverter 45 Supply of power cable 2C/16 sqmm,1.1 KV grade, multistranded copper conductor, XLPEFlexible cable. Finolex, Polycab or Havels 46 Supply of power cable 3C/2.5 sqmm,1.1 KV grade,multistranded copper conductor,Flexible cable. Finolex, Polycab or Havels 47 Supply of 9W LED Lamp any reputed brand. 48 Supply of LED Tube light fitting12 W/230 V, 4 ft in white colour etc. any reputed brand. 49 Supply ofBulkhead Light, IP 65 Protection with 10 Watt,230 V, any reputed brand. 50 Supply of Exhaust fan upto 200mm any reputed brand. 51 Supply of 2 Mtr length cable trunking38x25MM,any reputed brand. 52 Supply & Installation of Air conditioner Unit with following feature, Capacity 1.5 Ton,BEE-5 Star, Type : Inverter variable speed,Unit type :- Split AC,Material of Condensor :- Copper,Warranty : As per OEM. 53 Supply and Installation of solar based refrigerator,12V,200L 54 Supply & Installation of 43 UHD Android smart LED Television,any reputed brand. 55 Supply of 2 Mtr length cable trunking PVC Tray 75x50MM,any reputed brand. 56 Supply of 16X Zoom, multi layer coated glass, porro prism type Binocular lens. 57 Installation of Cable trunk PVC tray and drawing cables with screws,grip,etc. 58 Supply and Installation of GI pipe Bracketfor holding Street Light Fitting on wall 59 Supply and Installtion of 40A 2Pole Changeover MCB. 60 Supply & Installation of 7W tubelight for mirror,any reputed brand. 61 Supply and Insallation of 40mm Corrugated Steel reinforced flexible PVC pipe 62 Supply and Insallation of 25mm Corrugated Steel reinforced flexible PVC pipe 63 Supply and Installation of 9Litre RO Water purifier 64 Supply and Fixing of 5A/230V Holder Adaptor 65 Supply and Installation of 100A 3+1 Copper Busbar with all complete.any reputed brand 66 Supply & Installation of Wall Mounted Fan,any reputed brand. 67 Supply and Installation of DTH with 01 Year Recharge 68 Transportation of PART-A Materials and labours from Thal Jetty to Khanoji Angre Island Jetty(by boat)and Khanhoji Angre jetty to Lighthouse (by Head Load) including boat transportation charges.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 10-10-2025 Corrigendum-1 Technical Bid 30-10-2025

Key Value

Document Fees
Refer document
Tender Value
INR 10.34 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail