| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking materialwithin 50 meters lead. For thickness of tiles 10 mm to 25 mm |
| 2 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all completeas per directions of Engineer-in-Charge. |
| 3 | Dismantling of flushing cistern of all types(C.I/PVC/Vitreous china) including stacking of useful materials near the site and disposal ofunserviceable materials within 50 meters lead |
| 4 | Dismantling wooden boardings in lining of walls and partitions, excluding supportingmembers but including stacking within 50 meters lead : Upto 10 mm thick |
| 5 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : Ofarea of 3 sqm. and below |
| 6 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : Ofarea beyond 3 sqm. |
| 7 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. |
| 8 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil : 25 meterbeyond 1 m from cutting edge. |
| 9 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge:1:3:6 or richer mix (i/c equivalent design mix). |
| 10 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) |
| 11 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand :8 graded stone aggregate 40 mm nominal size) |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns etc. for mass concrete. |
| 13 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 14 | Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meterslead With cement mortar 1:4 (1 cement : 4 fine sand) |
| 15 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 16 | Half brick masonry with common burnt clay (non-modular) bricks of class designation7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 17 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 18 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade (Area of slab over 0.5 sqm) 16mm. |
| 19 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment ofmatching shade complete. |
| 20 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown |
| 21 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile600x600 mm. |
| 22 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete.Size of tile 600x600 mm |
| 23 | Providing and laying matt finished vitrified tile of specified size having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in outdoor floors such as footpath, court yard multi models etc., laid on 20mm thick base of cement mortar 1:4 (1cement: 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as direction of Engineer-in-Charge. 300x300x9.8 mm |
| 24 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position :Budloo /Fir wood. |
| 25 | Providing and fixing hard board sheet ceiling of approved quality with necessary nails etc. complete(frame work to be paid for separately) Standard Quality board 4.5mm. |
| 26 | Providing and fixing wooden moulded corner beading of size 50x50 mm (base and height) of triangular shape to the junction of paneling etc. with iron screws,plugs and priming coat on unexposed surface etc. complete. Second class kail wood |
| 27 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) First class kail wood |
| 28 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws |
| 29 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thickfloat glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. First class kail wood 30mm. |
| 30 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : First class kail wood 30 mm thick door |
| 31 | Providing and fixing fly proof wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions all complete.With Galvanized M.S. Wire gauge with wire of dia 0.63 mm With 2nd class teak wood beading62x19 mm |
| 32 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 33 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per thedirection of Engineer-incharge. Made of G.I. wire of dia 4 mm |
| 34 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to openings/wooden frames with rawl plugs screws etc. |
| 35 | Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an evenshade. Two or more coats on new work |
| 36 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @2.20kg/10sqm) |
| 37 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.1mm thick |
| 38 | Applying priming coats with primer of approved brand and manufacturehaving low VOC ( Volatile organic Compound) content. With water thinnable cement primer on wall surface having VOCcontent less than 50 grams/liter |
| 39 | Removing dry or oil bound distemper, Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic water proofing cement paint and the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete. |
| 40 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to givean even shade, one or more coats on old work. |
| 41 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work |
| 42 | Applying priming coat: With ready mixed red oxide Zinc Chromate primer of approved brand andmanufacture on steel galvanized iron/steel works |
| 43 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and softwood) having VOC content less than 50 grams/liter |
| 44 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc.complete :150x10 mm |
| 45 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc.complete :100x10 mm |
| 46 | Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete :250x16 mm |
| 47 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 100 mm |
| 48 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm |
| 49 | Providing and fixing aluminum extruded section body tubular type universal hydraulic door closer,(having brand logo with IS: 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessoriesand screws etc. complete : |
| 50 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design : Inside size 90x80 cm and 60 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 51 | Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep for single pipe line |
| 52 | Providing and fixing un-plasticized Rigid PVC pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. Singlesocketed pipes 75 mm diametre |
| 53 | Providing and fixing un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.Single socketed pipes 110 mm diametre |
| 54 | Providing and fixing un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5° 75 mm bend |
| 55 | Providing and fixing un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. BBend 87.5° 110 mm bend |
| 56 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. 20mm nominal outer dia pipes. |
| 57 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 25mm nominal outer dia pipes. |
| 58 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points ofapproved make conforming to IS : 8931 |
| 59 | Providing and fixing un plasticized P.V.C. connection pipe with PTMT nuts, collars and bush ofapproved quality and colour 15 mm nominal bore with 30 cm length. |
| 60 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI markedwhite solid plastic seat and lid. |
| 61 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. |
| 62 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-White Vitreous China Wash basin size 550x400 mm with a 15 mm CPBrass single hole basin mixer |
| 63 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the backfor the reception of pipes and fittings. |
| 64 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: Waste coupling 38mm of 83 mm length and 77 mm breadth weighing not less than 60gms. |
| 65 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittingscomplete Flexible pipe 32 mm dia |
| 66 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS :8931 |
| 67 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 150 mm diameter |
| 68 | Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominaldia. |
| 69 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make andquality as per direction of Engineer-incharge. |
| 70 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws andwashers complete. |
| 71 | Providing and fixing 600x120x5mm glass shelf with edges round off supported on anodizedaluminum angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs, etc. complete |
| 72 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour: 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170gms. |
| 73 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x460mm bowl depth 200mm |
| 74 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls andfloors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 75 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 76 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, raftersand trusses and including cutting to size and shape wherever required. 0.50 mm thick with zinccoating not less than 275 gram/m2 |
| 77 | Wiring for light/power plug with 2x4 sq. mm FRLS insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 no. 4 sq.mmm FRLS PVC insulated copper conductor single core cable for loo earthing as required. |
| 78 | Wiring for circuit/Submain wiring alongwith earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 78.1 :2x 2.5 sq.mm +1x2.5 sq.mm earth wire |
| 79 | Wiring for circuit/Submain wiring alongwith earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 78.20 2x 6 sq.mm + 1x 6 sq.mm earth wire |
| 80 | Wiring for circuit/Submain wiring alongwith earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 x 10 sqmm + 1 x 6 sq.mm earth wire |
| 81 | Wiring for circuit/Submain wiring alongwith earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 x16 sq. mm + 1x6 sq. mm earth wire |
| 82 | Supplying and drawing the following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm |
| 83 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 84 | wiring forlight point/fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor, single core cable in surfac/recessed medium class PVC conduit, with modular switch,modulal plate, sutable GI box and earthing the point with 1.5 sqmm FRLS pvc insulated copper conductor single core cable etc as required. Group A |
| 85 | wiring forlight point/fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor, single core cable in surfac/recessed medium class PVC conduit, with modular switch,modulal plate, sutable GI box and earthing the point with 1.5 sqmm FRLS pvc insulated copper conductor single core cable etc as required.Group B |
| 86 | wiring forlight point/fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor, single core cable in surfac/recessed medium class PVC conduit, with modular switch,modulal plate, sutable GI box and earthing the point with 1.5 sqmm FRLS pvc insulated copper conductor single core cable etc as required :Group C |
| 87 | Supplying and fixing the following sizes/modules, GI box along with modular base & cover plate for modular switches in recess, etc., as required: 1/2 Module (75mmX75mm). |
| 88 | Supplying and fixing the following sizes/modules, GI box along with modular base & cover plate for modular switches in recess, etc., as required: 3 Module (100 mm x 75 mm). |
| 89 | Supplying and fixing the following sizes/modules, GI box along with modular base & cover plate for modular switches in recess, etc., as required ; 6 module ( 200mm x 75 mm) |
| 90 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amp Switch |
| 91 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 92 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push (switch) |
| 93 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push (switch)2-way 5/6 amp switch |
| 94 | Supplying and fixing sutaible size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16 A modular switch, connection etc. as required. |
| 95 | Supply and fixing 3 pin 5A ceiling rose on the existing junction box/ wooden block including connection etc. as required. |
| 96 | Supply and fixing call bell/buzzer sutaible for single phase, 230 V complete as required. |
| 97 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 98 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 99 | Supply and fixing of 5 amp to 32 amprating,240/415V,10KA\"C\" curve, miniature circuit breaker suitable for inductiveload of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. 10 Amps. |
| 100 | Supply and fixing of 5 amp to 32 amprating,240/415V,10KA\"C\" curve, miniature circuit breaker suitable for inductiveload of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.20/16 Amps. |
| 101 | Supply and fixing of 5 amp to 32 amprating,240/415V,10KA\"C\" curve, miniature circuit breaker suitable for inductiveload of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. 32 Amps. |
| 102 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 103 | Supply and fixing of following rating,double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB),having a sensitivity current upto 30 milliampheres in the existingMCB DB complete with connections, testing and commisioning etc as required.40 Amp. |
| 104 | Supply and fixing of following way ,single pole and neutral , sheet steel MCB distribution board , 240Von surface/recess complete with tinned copper bus bar, neutral bus bar , earth bar, din bar,interconnections,powder painted including earthing etc. as required(But without MCB/RCCB/Isolator).6 way , Double door |
| 105 | Supply and fixing of following way ,single pole and neutral , sheet steel MCB distribution board , 240Von surface/recess complete with tinned copper bus bar, neutral bus bar , earth bar, din bar,interconnections,powder painted including earthing etc. as required(But without MCB/RCCB/Isolator).12 way, double door |
| 106 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc required.100A, 30 KA , FPMCCB. |
| 107 | Providing and Fixing Earthing with GI Earth Plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate and having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required |
| 108 | Supplying and laying 25 mm x 5 mm GI strip at 0.50 metre below ground as stripearth electrode, including connection/termination with GI nut, bolt, spring, washer etc as required. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50 mm. |
| 109 | Supply and fixing stiff brass batten/ angle holder including connection etc is required. |
| 110 | Installation,testing and commissioning of pre-wired,fluorescent fitting/compact fluorescent fitting of all types,complete with all accessories and tube etc.directly on ceiling/wall,including connection with 1.5 sq.mm FRLS PVC insulated,copper conductor,single core cable and earthing etc as required. |
| 111 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 112 | Supply, installation, and connection of 36-watt LED Ceiling light size 2\"x2\"(approx) including all accessories, make- Havells/Phillips/Orient or as approved by EIC |
| 113 | Supply, installation, and connection of 18-watt LED Ceiling light size 1\"x1\"(approx), including all accessories, make- Havells/Phillips/Orient or as approved by EIC |
| 114 | Supply, installation and connection of single phase 200mm Exhaust fan with a shutter. Make-Havells/Crompton/Orient / Bajaj or as approved by EIC |
| 115 | Footpath /Pathway Light: supply, installation and connection of 12-watt LED booland light. Model No.- Philips sterling Pedestal light or as approved by EIC |
| 116 | Fencing Light/Gate Light:- supply, installation and connection of 20 watt LED fencing light. Supporting upto 20watt LED lamp. Make- havells moon (opal) lamp supporting upto 20 watt LED lamp. |
| 117 | Supply and Fixing of Bus bar Rating 200A, 4 way and making proper cable connection. Make- Anchor/Havells or as approved by EIC. |