| 1 | Excavation in trenches in soft/loose soil n.exc 1.5 Mtr deep and n.exc 1.5 mtr wide for laying of HT cable and getting out including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation, complete all as specified and directed. |
| 2 | Excavation in trenches exceeding 1.5m depth and not exc. 3.0m wide and getting out in soft/ loose soil complete all as specified and directed. |
| 3 | Returning, filling, including leveling, watering and well ramming excavated soil in layers n.exc25cm thick in trenches after cable have been laid, complete all as specified and as directed. |
| 4 | Removing of excavated surplus soil obtained from excavation to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr of the starting point, complete all as specified and directed. |
| 5 | M&L for PCC 1:4:8, type C-2, using 40mm graded crushed stone aggregate as in foundation for stay set/ Pole/ FPB etc including surface finished even and fair to exposed surfaces without using extra cement complete all as specified and directed. |
| 6 | M&L for PCC 1:3:6, type C-2, using 40mm graded crushed stone aggregate as in foundation for stay set /Pole /FPB etc incl finished surface even and fair to exposed surfaces without using extra cement, complete all as specified and directed. |
| 7 | M&L for PCC 1:2:4, type B-1, using 20mm graded crushed stone aggregate as in coping of pole including necessary form work as required complete all as specified and directed. |
| 8 | Dismantling and taking down old wornt out ACSR conductor of any type and size complete all as specified and directed. |
| 9 | Dismantling & taking down old wornt out/ rusted MS clamps/ crossarms/ channels complete with nuts & bolts etc., complete all as specified and directed. |
| 10 | Dismantling & taking down old insulators any type, any size complete all as specified and directed. |
| 11 | Dismantling & removing LT Steel Poles/ Street light Steel Poles, struts any size complete and making good to the disturbed surfaces complete all as specified and directed. |
| 12 | Supply, laying, jointing and testing of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable with multistranded aluminium conductor, 1100 volts grade of size 120sqmm, 3.5 core confirming to IS: 7098 (Part - I) laid in trenches,under road or passing through pipes/ducts or fixed to walls/ poles complete with proper thimbles, complete all as specified and directed. |
| 13 | Supply, laying, jointing and testing of cable XLPE insulated, screened, PVC bedded ,galvanized steel strip or wire armoured heavy duty electric cable with multistranded aluminium conductor, 1100 volts grade of size 95 Sqmm 3.5 core confirming to IS : 7098 (Part - I) laid in trenches, under road or passing through pipes/ ducts or fixed to walls/poles complete with proper thimbles, complete all as specified and directed. |
| 14 | Supply, laying, jointing and testing of cable XLPE insulated, screened, PVC bedded ,galvanized steel strip or wire armoured heavy duty electric cable with multistranded aluminium conductor, 1100 volts grade of size 70 Sqmm 3.5 core confirming to IS: 7098 (Part - I) laid in trenches, under road or passing through pipes/ ducts or fixed to walls/poles complete with proper thimbles, complete all as specified and directed. |
| 15 | Supply, laying, jointing and testing of cable XLPE insulated, screened, PVC bedded ,galvanized steel strip or wire armoured heavy duty electric cable with multistranded aluminium conductor, 1100 volts grade of size 50 Sqmm 3.5 core confirming to IS : 7098 (Part - 1) laid in trenches,under road or passing through pipes/ducts or fixed to walls/poles complete with proper thimbles, complete all as specified and directed. |
| 16 | Supply, laying, jointing and testing of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable with multistranded aluminium conductor, 1100 volts grade of size 25 Sqmm 4 core confirming to IS : 7098 (Part - I) laid in trenches, under road or passing through pipes/ ducts or fixed to walls/poles complete with proper thimbles, complete all as specified and directed. |
| 17 | Supply, laying, jointing and testing of cable XLPE insulated, screened, PVC bedded ,galvanized steel strip or wire armoured heavy duty electric cable with multistranded aluminium conductor, 1100 volts grade of size 10 Sqmm 2 core confirming to IS : 7098 (Part - I) laid in trenches,under road or passing through pipes/ducts or fixed to walls/poles complete with proper thimbles complete all as specified and directed. |
| 18 | M&L for sub class \"B\" old size of Brick in trenches for cable protection of LT cables, complete all as specified and directed. |
| 19 | M&L for sand filling under floors or in foundations including watering and consolidation for UG cable complete all as specified and directed. |
| 20 | S&F in repair for GI pipe light grade of size 40mm dia laying in trenches/ under floor/on walls for protection of UG cables complete all as specified and directed |
| 21 | S&F in repair for GI pipe light grade of size 50mm dia laying in trenches/ under floor/on walls for protection of UG cables complete all as specified and directed |
| 22 | S&F in repair for GI pipe light grade of size 80mm dia laying in trenches/ under floor/on walls for protection of UG cables complete all as specified and directed |
| 23 | Supply, installation, testing and commissioning factory made, LT bus bar panel board cubical, Outdoor type, floor/ground mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts.The panel board shall be made of 3.15 thick CRCA sheet(Min size 0.6 m x 0.5 m x 0.35 m ), the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seventank phosphate treatment front & back opening type and fixing 2 Nos danger notice plate with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in hindi and english with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL& 1/2 mtr for Below GL in PCC 1:3:6, type C-2, using 40mm graded crushed stone aggregate comprising of following:- |
| 24 | The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with and comprising of the following:- (i) Epoxy insulated common aluminium bus bar of capacity 500 Amp TPN each with Color Coding, including aluminium lugs to connect the cable. (ii) MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA-01 No (For main Incomming )(iii) Volt Meter 0 - 500 Volts digital type square shape flush mounted with selector switch - 1No(iv) Ammeter 0 - 400 Amp digital type square shape 96mm flush mounted with selector switch and CT\"s 400/5 A - 1 No.(v) Indicator lamp RYB: 01 Set complete |
| 25 | Supply, installation, testing and commissioning factory made, LT bus bar panel board cubical, Outdoor type, floor/ground mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts.The panel board shall be made of 3.15 thick CRCA sheet(Min size 0.6 m x 0.5 m x 0.35 m ), the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seventank phosphate treatment front & back opening type and fixing 2 Nos danger notice plate with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL& 1/2 mtr for Below GL in PCC (1:3:6) type C-2 using 40 mm stone aggregatescomprising of following:- |
| 26 | The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with and comprising of the following:- (i) Epoxy insulated common aluminium bus bar of capacity 400 Amp TPN each with Color Coding, including aluminium lugs to connect the cable. (ii) MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA-01 No (For main Incomming )(iii) Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1No(iv) Ammeter 0 - 400 Amps digital type square shape 96mm flush mounted with selector switch and CT\"s 400/5 A - 1 No.(v) Indicator lamp RYB :01 Set complete |
| 27 | Supply, installation, testing and commissioning factory made, LT bus bar panel board cubical, Outdoor type, floor/ground mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts.The panel board shall be made of 3.15 thick CRCA sheet(Min size 0.6 m x 0.5 m x 0.35 m ), the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seventank phosphate treatment front & back opening type and fixing 2 Nos danger notice plate with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL& 1/2 mtr for Below GL in PCC (1:3:6) type C-2 using 40 mm stone aggregatescomprising of following:- |
| 28 | The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with and comprising of the following:- (i) Epoxy insulated common aluminium bus bar of capacity 315 Amp TPN each with Color Coding, including aluminium lugs to connect the cable. (ii) MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA-01 No (For main Incomming )(iii) Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 Nos(iv) Ammeter 0 - 400 Amps digital type square shape 96mm flush mounted with selector switch and CT\"s 400/5 A - 1 Nos.(v) Indicator lamp RYB :01 Set complete |
| 29 | Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 metre below normal ground level with top edge of the earth plate not less 1.5 metre (BGL) connected to galvanized iron earth strip 32 x6 mm by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4, type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 15 mm bore “Light grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 40 mm bore “light grade” galvanized iron protection pipe for earth strip 32 x6 mmupto 7.5 m length, charcoal, common salt, complete all as shown in EP No 1 of SSR 2020 Part-I, connected to test point complete, testing on completion, complete all as specified and directed. Note: Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, porcelain insulator, PCC earth Pit, CI frame, RCC cover, funnel with wire mesh are incl in quoted rate andwatering pipe, earth lead protection pipe, test poit, earth lead up to 7.5 mtr. |
| 30 | M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) and painting to LT steel tubular pole with 09 mtr long except planting depth/ PCC coping with and including two coats aluminum paint over a coat of red oxide primer, completeall as specified and directed. |
| 31 | S&F LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 32 | S&F 3 core 1.5 sqmm PVC insulated and FRLS-H PVC round sheathed copper conductor flexible 1100 voltsfor connection from OH Line to street light fittings complete all as specified and directed. |
| 33 | S&Fstreet light pole cable junction box IP-66 size should be not less than 155 x 210 x 92 mm(upto Cable Size 10/16sq.mm) with the box made out of thermal plastic(Thermoplastic Polycarbonate) material suitable for 10/16 UG sqmm cable. The JB shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive,IP 65 in accordance with IEC 60529,Weatherproof UV-resistant, rainwater-proof, temperature-resistant. The impact strength of Polycarbonate enclosure/ boards i.e. the Degree of protection against mechanical load shall be in accordance with EN 50298 - 98 for IK 08 including one No. 4 pole connector and one no.MCB SP6Ampand chromium plated clamps, Suitable Cable Gromets and nut bolts complete all accessories. Make: Hensel Cat Part No. DK 1616 G or equivalent of Siemens/ Schneider/ ABB. |
| 34 | S&F GI Bracket for street light fitting bend to shape made out of GI pipe light grade 40mm bore upto1.2 mtr longetc complete with MS clamps made from 40x6 mm MS flat, duly painted with two coat of aluminum paint with nuts/bolts/washers for fixing arrangement to pole /wall complete all as specified and directed. |
| 35 | M&L forbroken stone or boulder hard core of gauge n.exc. 63mm deposited spread and leveled in layers n.exc 15cm thick watered and rammed to a true surface complete all as specified and directed. |
| 36 | M&L for PCC 1:1.5:3, type A-1, using 20mm graded course aggregate as in top gap filing of road/path etc complete all as specified and directed. |
| 37 | Supply, fixing or laying of HDPE (DWC) tubing 50 mm inner dia of pressure rating 6Kgf/Cm2 fixing on poles, walls under floors, laying on surface etcas reqd at site and as per direction, complete all as specified and directed. |
| 38 | Supply, fixing or laying of HDPE (DWC) tubing 40/38 mm inner dia of pressure rating 6Kgf/Cm2 fixing on poles, walls under floors, laying on surface etcas reqd at Site and as per direction, complete all as specified and directed. |
| 39 | S&F in repair/ replacement for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 40 | S&F in repair for 100mm thick, PCC 1:4:8, type D-2, using 40mm graded crushed stone aggragate as in flooring complete all as specified and directed. |