}

Tender For Special Repair To Bldg No Kp-02 (08 Qtrs) At Napier Road Under Ge (C) Kolkata, kolkata-West Bengal

Tender Notice

51653269
Corrigendum : Tender For Special Repair To Bldg No Kp-02 (08 Qtrs) At Napier Road Under Ge (C) Kolkata
Tender
Indian
West Bengal
Kolkata
03-11-2025

Tender Details

Tender For Special Repair To Bldg No Kp-02 (08 Qtrs) At Napier Road Under Ge (C) Kolkata; 1 Demolition of Cement concrete of any description and in any position not otherwise specifically provided for etc complete all as specified and directed. 2 Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided forcomplete all as specified and directed. 3 Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed. 4 Taking down shutter of any descriptionexc. 1.00 Sqm but nexc 2.0 Sqm Each complete all as specified and as directed. 5 Taking down Chowkats or Frames,(without taking off Shutter from the Frame) exc. 1.50 Sqm but not exc. 4.00 Sqm Each, complete all as specified and as directed. 6 Taking down Chowkat or Frame (without taking off Shutter from the Frame) n exc. 1.50 Sqmcomplete all as specified and as directed. 7 Dismantling Wrought Iron or Mild Steel Work, viz. MS Flat Iron (Wind Tie) and Similar Work including MS Bolts, Nuts, etc., complete all as specified and as directed. 8 Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing), and removing rubbish off the Premises, complete all as specified and as directed. 9 Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in mortar complete all as specified and directed. 10 Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including racking out joints, hacking for key, scrubbing down with Water, remove dust, debries/ rubbish, etc., complete all as specified and as directed. 11 Taking up or down Steel Water Tubing 15mm dia (bore) including Connections and Fittings, Segregating Serviceable Pipes & Fittings, Stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed. 12 Taking up or down Steel Water Tubing 20mm dia (bore) including Connections and Fittings, Segregating Serviceable Pipes & Fittings, Stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed. 13 Dismantling of 100mm dia cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required, complete all as specified and as directed. 14 M&L Plain Cement Concrete type E2 (1:5:10) using 40 mm graded aggregate as inMass Concrete of sunken floor complete all as specified and as directed. 15 M&L Cement Concrete type B1 (1:2:4) (20mm graded aggregate) in saucer drain, slop to be maintained and surface finishing concrete surfaces fair and even, complete all as specified and as directed. 16 M&L Reinforced Cement Concrete Type B1 (1:2:4) (20mm graded crushed stone aggregate) as in Slab supported on Walls, complete all as specified and as directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. 17 M&L Reinforced Cement ConcreteType B1(1:2:4) (20mm graded crushed stone aggregate)in Chajja / kitchen rackbalcony etc., complete all as specified and as directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. 18 M&LCement Concrete Type B0 (1:2:4) (20mm graded crushed stone aggregate) roofkerbs or mud stop watertroughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. 19 M&L Brick work usingPulverizes fly ash bricks of class designation 75, straigth or curved on plan exc 6m mean radius built in CM (1:4) cmplete all as specified and directed. 20 M&L Brick Work with Half Brick work usingPulverizes fly ash bricks of class designation 75, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directed. 21 Chipping of unsound /weak concrete materials from slabs , beams, columns ,lintel,chajja, fin , facia etc. by any meansincluding tapering all edges, making square shoulders of cavities air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting incl foreign matrials , loose concrete/aggregate etcand disposal of all debris out of MOD landfor 25-30mm average thickness for slabs/Chajja/beams complete all as specifiedandas directedby Engr-in-Charge. 22 Material and labour Chipping of unsound/weak concrete materials of 50mm average thickness from column/ beam/lintel with lightly picking materials by air blasting or sand blasting includingtaperingall edges, making square shoulders of cavities etc uptofour storey height of building including necessary scaffolding and safety measure complete all as specified and as directed by the Engr-in-Charge. 23 Material and labour Removingconcrete all around reinforcementincluding behindofreinforcement barsto give an averageclearance of 25mm (but not less than 15mm clear air gap) by manual methods (hammering and using wire brushes, chieselling etc.) and applying alkaline rust removing chemical followed by removing rust including from behind the reinfircement bars by emery paper and cleaning the area throughly by water and alllow it to dry as per manufacturers instructions to provide totally rust free finished steel surfaces,length of reinforcement bars cleared of concrete shall be measured for payment including upto any height of buildingabove 12mm dia of bars complete all as specified and as directed by the Engr-in-Charge. Make:-Fosroc/Elantas beck/Kunal conchem/ Sika/ Hindcon Chemicals Ltd/ Icannano 24 Supply and application Epoxy Zinc rich primer on the prepared reinforced surface by brush, the primer shall have a minimum specific gravity 1.75, minimum wet film thickness/coat 100 microns & dry film thickness/coat 40 microns. Minimum adhesive bond strength with steel is 1.5 N/mm2 uptouptofour storey height of buildingcomplete all as specified and as directed by the Engr-in-Charge. Make : Fosroc/Elantas beck/Kunal conchem/ Sika /Hindcon Chemicals Ltd/ Icannano 25 Material and labourCleaning of exposed concrete surfaces of lightly sticking materials including foreign materials, loose concrete/ aggregate etc and disposal of all debris upto distance of 50 m and applyingsingle coat of epoxy bond adhesive on prepared non metallic surfaces (existing surface) by using brush as per manufacturers instruction / specificationhaving minimum compressive strength of 40N/ sqmm upto any 4th storey of buildingcomplete all as specified and as directed by the Engr-in-Charge.Make : Fosroc/Elantas beck/Kunal conchem/ Sika/ Hindcon Chemicals Ltd/ Icannano 26 Materials and labourIntroducing new reinforcement bars for structural connections in RCC beam, lintels, columns and slabs etc including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm upto 200mm including power drilling, fixing the reinforcement in position using epoxy after dusting ofloose dust by blowing air, sealing the same with epoxy cartridges etc as per manufacturer instruction for upto 12mm dia of bar and uptofour storey height of building complete all as specified and as directed by the Engr-in-Charge. Make:-Fosroc/ Sika/ Hindcon Chemicals/ Icannano 27 Supply and Application Free flow non-shrink cementitious micro concreteof grade M50 to the affected column etc 60mm thickness (average)where major spalling has taken place even the core of concrete affected. The Micro concrete shall have a minimum 1 daycompressive strength of 10 MPa and 28 days strength of 50 MPa, Minimum tensile strength 5 N/mm2 @ 28 days, minimum Flexural strength 5 N/mm2@ 28 days tested as per BS 4551-80, Expansion characteristics Unrestrained expansion as per ASTM C827-1987 1 to 4%.upto four storey height of buildingcomplete all as specified and as directed by the Engr-in-Charge.Make:-Fosroc/Elantas beck/Kunal conchem/ Sika/ Hindcon Chemicals Ltd/ Icannano 28 Supply and Application Two component structural grade polymer modified reinstatement mortar where local spalling has taken place or shuttering is not possible. The Mortar can be applied from a minimum of 25mm average thickness in smaller vertical pockets and upto 100 mm thickness in horizontal applications. The Mortar should have a minimum compressive strength 12 N/mm² in 1 day and 45N/mm² in 28 days. Minimum Flexural strength should be 8 N/mm² in 28 days. A modified styrene butadience emulsion for use as a bonding aid and gauging liquid for cementitous systems to be mixed with cement slurry before the application of microconcrete to be used @ 6 lit/bag of cement. The bonding agent should have minimum compressive strength 24 N/mm² Minimum Tensile strength 3.5 N/mm², Minimum Flexural Strength 6.5 N/mm²complete all as specified and as directed by the Engr-in-Charge upto any height of building including necessary scaffolding and safety measure.Make : Fosroc/Elantas beck/Kunal conchem/ Sika/ Hindcon Chemicals Ltd/ Icannano 29 Material and labour applying of high efficiency polymeric resin base flim forming curing agent /compound over concrete surface and maximum coverage area 5.00 sqm per litreas per manufactures instructions including necessary scaffolding and safety measurescomplete all as specified and as directed by the Engr-in-Charge. Make- Concure LP90 of FOSROC or equivalent in Elantas beck/Kunal conchem/ Sika/ Hindcon Chemicals Ltd/ Icannano 30 Supply and applicationcementitous grouting admixture with the cementslurry at a dosage225 ml per bag cement and injecting with high pressure by grouting pump through non return PVC nozzels prefix with rapid setting cementitious plugging mortar to fill all possiblepores and gaps left with in the old concretemass, when the flowof groutstops or shows refusalsor groutflows out from the adjeacent nozzle, pumping to be stopped and the nozzle to tied up and allowed to set for 24 hours. the PVC nozzles to be sealedoff with quitck setting cementitious plugging mortar Grouting operation to be carried out throughnext nozle till the entire area is covered the grouting holes to be finishedby removingthe prtruded portion of nozzles and finishing flush with the surface complete as per manufactures instructions as specified and as directed (upto 4 storey building) 31 Supply and applying two coats of High performanceelastomeric cementitious waterproofcoatingsandwichwith 45 GSM glassfibrereinforcementon the enitrefloorand 1.0 m of all walls of all toilets as per following methodologycleaningof exposed concretesurfaceby mechanicalmeans or by hydroblasting to removelaitance loosed particles cantomination etc which may hinderbondingCoving of RCC jointswith PCC (1:1:5:3)mixed with integralwater proffing compound applying one coat of water proofingmembranceat the right angles to the direction of first coat. soceond coat shall be applied after the first coat gets dry. sprinkling fine aggregate immediately after the applicationof secondcoat to getthe mechnicalkey for protective plaster. curing to waterproffingmembrance to be carried out for minimumperiod of 3 days with ponding complete. the water proofing compound should have mixed density 1.68g/ccc (brushable consistency) adhesion to concrete :.1N/mm2 staticcrack accomdation 1mm (upto 4 storey buidlding) 32 M&LUse and waste of Formwork to sides of Pillars, Posts, Struts, Piers, Columns and stanchions, flat, rough finished surfaces of concrete, (upto 04 storey high of building) complete all as specified and as directed. 33 M&LUse and waste of Formwork to Sides and Soffits of Floor or Roof Beams, Beam Haunchings, Girders, Bres-Summers, Lintels, Cantilevers, Shelves including supports, overhangs, etc. also splays between floors and beams, etc., flat, rough finished surfaces of concrete, upto 04 storey high of building)complete all as specified and as directed. 34 S&F Second Class Hardwood Plain, Solid, Straight Chowkats and Frames, Wrought, Framed rebated on the Solid, Rounded or Chamfered, put together with Glue, Pinned at Joints, complete all as specified and as directed. 35 S&F 30mm thick Flush shutters, solid core construction, with partical board core and plywood face panels, commercial type on both sides fitted to cowkhats complete all as specified and directed. 36 M&L Factory made Second Class Hardwood 35mm thick Plain Framed Panelled Door Shutter ((two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and as directed. 37 M&L 30mm thick glazed and skelton shutters, open rebated and prepared to receive glass , gauge, etc (without sash bars) , edges of framing plain, chamfered of rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a) supplied and fitted to chowkhats complete all as specified and as directed. 38 M&L Second Class Hardwood Small Fittings such as Shaped Door and Window Stops and the like including all necessary Labours Articles not exc. 200 Cu Cm Each, complete all as specified and as directed.NOTE: Supply only Butt Hinge shall be Measured and Paid separately under relevant Item. 39 S&F Factory Made Solid PVC Door Frame of size 50 x 47 mm made out of 5.0 mm thick plain colour PVC Sheet reinforced with Mild Steel Square Tube, fixing in opening as per Specifications and Drawings shown in MES Schedule Part-II, complete all as specified and as directed. 40 S&F Plain Colour Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing etccomplete all as specified and as directed. 41 S&F Mild Steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips(upto 04 storey High of building) complete all as specified and as directed. 42 S&F Mild SteelTMT bars 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips (upto 04 storey High of building)complete all as specified and as directed. 43 M&L Mild Steel Flat Iron 25 x 3 mm, as in Holdfast for Door, Window Frames or Chowkats etc., cut to length or drilled hole and fixed with Screw, etc., grade of Steel conforming to Fe-290 Gde E-165, complete all as specified and as directed. 44 M&L Mild SteelFramed Work such as Grills, Gratings, etc. with ends of Bars shouldered and/or riveted, or forged into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework of Water Tanks and Similar Work, conforming to Fe-290, Gde-E-165, complete all as speci-fied and as directed. 45 S&FAluminium anodised (powder coated) Three track sliding window frame with shutters with ( 2 nos glazed and one wire gauzed shutter)including all necessary jointing cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete andglazing with and including 5 mm thick tinted glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc including deco grill with the following section of frame and shutter (A) Sections for shutter (i) H section 39 x 20 x 1.50 mm thick (ii) Interlock section 39 x 20 x 1.50 mm thick (iii) Edge & Bottom section 41 x 20 x 1.50 mm thick(B) Section for frame (i) Top & Sides 92mm X 29.70 X 1.50mm not less than 1.30 Kg /RM(ii) Bottom 92 X 29.70 X 1.50mm not less than 1.502 Kg /RM complete all as specified and directed . 46 S&F Aluminium ventilator with powder coated aluminium frame of section size 65.5 x 38.10 x 1.5 mm and Shutter with section 47.62mm x 44.5mm x 1.5mm thick including powder coated aluminium anodised “D” handle, hinges, peg stays, tower bolt etc including jointing cleats for fixing Builder hardware fittings, including necessary fittings fixture/aluminium snap beads etc complete all as specified & directed. 47 S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of brass polished bright finished as in repair complete all as specified and as directed. 48 S&F Aluminium alloy Handle 125mm long, cast type, anodized and fixed, complete all as specified and as directed. 49 S&F Aluminium alloy Handle 100mm long, cast type, anodized and fixed, complete all as specified and as directed. 50 S&F Hasp and staple 75mm size, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed. 51 S&F Aluminium anodized, Barrel Tower Bolt 100mm long, Extruded Section and fixed, complete all as specified and as directed. 52 S&F Aluminium anodized, Barrel Tower Bolt 200mm long, Extruded Section and fixed, complete all as specified and as directed. 53 S&F 300mm long Aluminium alloy, anodised, Sliding Door Bolt with Hasp, Staple (Bolt type) and Fixing Clips of Sheet, Cast or Extruded Sections and Fixing Bolts and Sliding Bolts of Extruded Sections or Cast-Aluminium alloy and fixed, complete all as specified and as directed. 54 S&F Mild Steel Butt Hinges, size of Hinges 100mm, medium weight, Cold Rolled and fixed, complete all as specified and as directed. 55 S&F Continuous (piano) hinges, mild steel, bright finish or elec-trogalvanised 30mm, bright finish and fixed, complete all as specified and as directed. 56 M&L Pre-laminated Particle Board 18/19 mm thick, interior grade, pre-laminated one side with decorative choice lamination and other side balancing white lamination fixed with Screws to Timber Frame Work as incup board shelf ,Pelmet Box or in narrow widths not exc. 15 Cm each, rebated or flat edged, as in repair complete all as specified and as directed. 57 M&L Drapery rod made ofelectric resistance welded MS pipe of 20mm dia having a coating of corrugated virgin PVC extrusionandcover with ABS plastic as in repair complete all as specified and directed. 58 S&FEnd Stopper, Decorative typefor drapery rod and includingclosed type stainless steelbrackets fixed on wall complete all as specified and directed. 59 Roughening of surface of old concrete roofing by picking sweeping cleaning and washing down with water to remove dust as directed and specified. 60 Stripping of old tarfelt including layer of plaster or morter of any type treatement carefully from roof surfaces (without damage of roof) and roughening of surface of old concrete roofing by picking sweeping cleaning and washing down with water to remove dust complete all as specified and as directed. 61 M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed. 62 M&L for 25mm thick PCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate finished with even and smooth without using extra cement for padding concrete/ base course to floor with minimumthickness of 25mm with a slope of 1:40 complete all as specified and directed 63 Materials and labour for 10 mm thick screed bed of bedding layer in CM 1:4 surface finished even and smooth using water proofing compound complete all as specified and directed. 64 M&L Water Proofing Treatment on existing cleaned RCC Roof with the following Specifications and Manufacturers instructions, complete all as specified and as directed :-(a) Preparing and cleaning of fully drysurface as per IS:3067-1966.(b) Applying tack coat of industrial bitumen 85/25 conforming to IS-3384-1986 over the Cleaned Plastered Surface @ 1.2 kg per Sqm.(c) Applying a layer of APP based Polymeric Membrance; 3.0mm thick (minimum) weighing 3.60 Kilogram per Square Metre (reinforced) with Polyster Non Woven Fabric weighing not less than 160 Grams per Square Metre by Torch application. The overlaps shall be minimum 100mm on the Transverse direction and 75mm on Longitudinal direction.(d) Applying one coat of Aluminium Paint @ 0.20 Litre per Sqm over APP based Polymeric Membrane. 65 M&L Cement Concretetype C2 (1:3:6) using 40mm graded crushed stone aggregate 75mm thick as in Plinth Protection, etc. laid in alternate Bays, finished Concrete Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed. 66 M&L Cement Concrete type D2(1:4:8) (20mm graded aggregate) 75mm thick,as insub base of flooring, complete all as specified and as directed. 67 M&L Granite (of any type) Work (Table rubbed and polished) 16 to 20 mm thick, in Steps, Cooking Platforms and like, Set in Screed bed of 20mm thick in Cement Mortar 1:4 including Pointing in White Cement 1:2 using Marble Dust with admixture of Pigment to match with Shade of Granite including Cutting and Polishingcomplete all as specified and as directed. 68 S&F Machine cut kota stone slab flooring 20-25mm thick (size 550mmx550mm) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite finish polishing complete over 20mm thick 1:6cement mortar screed bed complete all as specified and as directed. 69 S&F Machine cut kota stone slab flooring 20-25mm thickon Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc., Set Pillar and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tilesincluding rubbing and polishing complete over 20mm thick 1:4cement mortar screed bed complete all as specified and as directed. 70 Rounding to edges of stone slabs one edge such as steps, cooking platform and other similar situation complete all as specified and as directed. 71 M&L Chequered Cement Concrete Tiles 300 x 300x20 to 25 mm thick, Set in Screed bed of 20mm thick in Cement Mortar 1:6 and Jointed and pointed in Neat Cement Slurry with Grey Cement as in Floor, etc., complete all as specified and as directed. 72 M&L joint free non skid ceramic coloured tiles 8-10mm thick (square/rectangular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm in floor set and jointed in in neat cement slurry and pointed in cloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. 73 All as item No. 72.00 here in before but in skirting with and including 10mm thick rendering on fair faces of brickwork in CM 1:4 complete all as specified and directed. 74 M&L Glazed Ceramic Coloured Tile 450 x 300x 7.00mm thick on Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over and including 10mm thick backing layerin cement mortar (1:4) complete all as specified and as directed. 75 M&L Rendering15mm thick in Cement Mortar 1:6 on Brick Walls or on Concrete Surfaces, finishing plastered surfaces Even and fair without using Extra Cement complete all as specified and as directed. 76 M&L 20 mm thick rendering in cement mortar (1:4) on fair faces of brick or concrete externalsurfaces in two layers (each 10mm thick) finished even and smooth without using extra cement using water proofing compound on top layer @2%by weight of cement or as per manufactures instruction on external wall surface upto height of 4th storied bldg completeall as specified and directed.Note : WPC shall be measured and paid seperately 77 M&L Rendering 5.0mm thick in Cement Mortar 1:3 on Concrete Surfaces of Ceiling, etc. finishing Plastered Surfaces Even and Smooth, without using Extra Cement. complete all as specified and as directed. 78 Supply only liquid water proofing compound (ISI marked) complete all as specified and directed.Make:- STP NO 1/ PEDILITE(DR FIXIT)/ FOSROC/ CICO/ SIKA/ Icannano 79 M&L Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth in brick walls etc complete all as specified and as directed. 80 M&L Preparing old decorated surfaces of Ceiling and applying one coat of Distemper Oil Emulsion , complete all as specified and as directed. 81 M&L preparing new plastered surfaces of ceiling and and applying Two Coats of Distemper Oil Emulsion over a coat of primer over complete all as specified and as directed. 82 M&L for Preparation of new plastered surfaces and applying two coats of oil emulsion distemper (any colour/tint) over a coat of primer over2 mm thick wall care putty (Birla/Asian) on wall surfaces including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. 83 M&L Complete removal of existing Treatment of old decorated Surfaces of Walls and applying two coats of oil emulsion distemper (any colour/tint) over a coat of primer over2 mm thick wall care putty (Birla/Asian) on wall surfaces including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. 84 M&L preparing newly plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over2 mm thick wall care putty on wall surfaces including rubbing with emmery paper to make wall surface smooth and even complete all as specified & directed. 85 M&L complete removal of old decorated surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified & directed. 86 M&L Preparing old Wooden Surfaces of any description not otherwise decribed over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed. 87 M&L for preparation of old surfaces of steel or steel based materials of any descriptionand applying one coat of synthetic enamel paint (First quality) over 10 Cm width or girth complete all as specified. 88 M&L Preparing new Wood and Wood Based Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Pink Primer, complete all as specified and as directed. 89 M&L Preparing new Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Red Oxide/ Zinc Chrome Primer, complete all as specified and as directed. 90 Supply and fix 100 mmbore cast iron soilwaste and vent pipes in any length with or withoutears with cement joints, fixed to walls or floors, laid in trenches and disturbed portion of the wall making good withcement concrete in (1:2:4)includingdistance pieces plugs holder bats up to any heightof building with scaffolding etc and epoxy coated both insideand outside complete all as specified and directed by Engineer In charge(upto04 storey high of building) 91 S&F Cast Iron Bend 100mm bore (dia), any radius, Disminishing Pieces or Tapers (Large Bore measured) and fitted with Oval Access Doors including Jointing with Cement Mortar 1:1, complete all as specified and as directed. 92 S&FCast iron 100mm bore cowls complete all as specified and directed. 93 S&F Cast Iron Traps ‘P’ or ‘S’100mm bore, complete all as specified and as directed. 94 S&Ffor Stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays including bolts and nuts and securing ends of stays to wall or roof Bore in pipe in 75mm to 150mm complete all as specified and directed. 95 S&F CPVC pipes 20mm outer diameter of SDR 11 & plain CPVC SDR 11fittings fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed. 96 S&F CPVC pipes 25mm outer diameter of SDR 11 & plain CPVC SDR 11fittings fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed. 97 S&F CPVC Ball Valve 25mmouter diascrewed for Iron Pipe and fixed, complete all as specified and as directed. 98 S&F 20mm bore Male brass Threaded adaptor (MTA/MBTA) for CPVC pipe as in repair complete all as specified and directed. 99 S&F 20mm bore Female brass Threaded adaptor (FTA/FBTA) for CPVC pipe as in repair complete all as specified and directed. 100 S&F 20mm bore Brass Elbow complete all as specified and directed. 101 S&F 16mm bore Brass TEE complete all as specified and directed. 102 S&F Rotational Moulded Polyethylene (HDPE) Water Storage Tank 1000 Litre Capacity (Cylindrical Vertical with Closed Top), Black in Colour, Three Layered Construction, hoisted and fixed in Position all specified in MES Schedule Part-I including provision of 25mm x 100mm GI nippples with check nuts for inlet, outlet wash and overflow pipe including Lowering of old/unserviceable Water Storage Tank of any description, complete all as specified and as directed. 103 S&F Mirror Bevelled Edge 600x450mm, Selected quality Glass, mounted on 6.0mm thick AC Building Board or Commercial Ply-wood and fixed to Wooden Plugs with Chro-mium Plated Brass Screws and Cup Washersas in repair complete all as specified and as directed. 104 S&F 32 mm diaPVC waste pipefor WHB/Kitchen sink including all necessary fixing arrangement as in repair complete all as specified and as directed. 105 S&F 32mm waste coupling of PTMT ( full threaded)minimum weight 45 grams for wash hand basin as in repair complete all as specified and directed. 106 Supply and fixing in repair 10 litre capacity low level PVC flushing cistern (any colour), syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete as directed. 107 Supply and fix in repairs Vitreous China squatting pan of‘Orissa pattern’, size 580 mm x 440mm (white) with ‘P’ or ‘S’ trap, front or back inlet and foot rests, any pattern complete including provision of PCC bedding andconnection to trap, and to flushing pipe, antisyphonage pipe, etc. complete including making good to floorall as specified and directed by the Engr-in-Charge. 108 S&F Vitreous China Wash Hand Basin 550x400mm in size, White (Flat Back or Angle Back Type) with 32mm dia Brass Chromium Plated Waste Fitting and 15mm dia PVC connector pipe,a pair of Cast Iron Brackets duly painted Stand including Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3including taking down old one complete all as specified and as directed. 109 Supply and fixstainless steelkitchen rack of size 31x36x10 with 0.63mm stainless steel sheet with all fittings accessories , complete as directed. 110 S&F PVC Conncetions 15mm size with PTMT Nuts of length 600mm long, complete all as specified and as directed. 111 S&F PVC (SWR) Soil, Waste and Ventilating Pipe 110mm bore (dia), single socketed, in any length with Rubber Ring Joints fixed to Walls, complete all as specified and as directed. 112 S&F PVC (SWR) Bend 110mm bore (dia), any type, and Jointing with Solvent Cement, complete all as specified and as directed. 113 S&F PVC (SWR) Junction 110mm bore (dia), Single (Single T) equal or unequal and Jointing with Solvent Cement, complete all as specified and as directed. 114 S&FPVC (SWR) 110mm bore Branch pieces, double (double y) (equal or unqual), ordinary or inverted (spigot or socket type) or with parallel branches or fitted with oval access doors as complete all as specified and directed. 115 S&F PVC (SWR) Nahani/Floor Trap 100mm bore (dia) Outlet, Plain with Grating and Jointing with Solvent Cement,including taking down old one complete all as specified and as directed. 116 S&F PTMT Grating of 100mm size (Min weight 25 grms) fixed with cement morter(1:3) complete all as specified and as directed. 117 S&F in repair 15mm Bib Taps, fancy type, CP, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. 118 S&F in repair 15mm bore stop cock, cast copper alloy, chromium plated , screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. 119 S&F in repair 15mm bore Angular concealed stop cock, fancy type cast copper alloy, chromium plated , screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. 120 S&F in repairs 125mm size Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as directed by engineer-in-Charge. 121 S&F Chromium Plated soap dish fixed to wall with necessary fixing arrangementcomplete all as specified and directed 122 S&F Towel rail 450mm long of PTMT with chromium plated brass screws and wooden/plastic cleats minimum weight 170 gramscomplete all as specified and directed. 123 S&FGlass shelf assembly consisting of 5.5 mm thick sheet glass, 60 cm long with chromium plated brackets guard andrailing fixed in position with necessary fixing arrangement as in repair complete all as specified and directed. 124 S&F Brass chromium plated fancy type pillar tapscrewed for 15 mm boreof pipeetc.incl necessary fittings & fixturesas in repair complete all as specified & directed. 125 S&F Stainless Steel Sink without Drainage Board l.0mm thick Overall size 915mm x 460mm and Bowl size 410 mm x 355mm x 165 mm for Kitchen or Laboratory with Plugs, Washers,Brass chromium plated Waste Fitting 32mm dia,PVC waste pipe, a Pair of Cast Iron Brackets duly Painted including Cutting and Pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 including Taking down/out unserviceable Sink and connected Items, complete all as specified and as directed. 126 Taking down carefully unserviceable copper / aluminium point wiring (light, fan, socket or power) including all fittings such as switches, socket, ceiling roses and fittings ( except tube light fittings) complete and making good the disturbed surfaces complete all as directed by Engineer-in-Charge. 127 M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium dutywith all accessories including fabricated 1.6 mm thick MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets,regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth including Cutting chase, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges and connecting to earth dolly all as specified for one light or fanpoint controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed.Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. 128 All as per item No.127.00here-in-before but one 3 pin 5 ampsswitch socket outlet on the independent board with other switch complete all as specified and directed by Engineer-in-charge. 129 All as per item No.127.00here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge. 130 M&LPoint wiringwith 2.5 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC concealed conduit 20mm dia medium duty with all fittings and accessories of casing caping(like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLSH copper cable as earth continuity wire connecting to common earth point (including supply & fixing of 1.6 mm thick pressed mild steelterminal boxes of suitable size with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc.including Cutting chase, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edgesfor mounting sockets for 5 pin, 16 Amp socket outlet on independent board complete all as specified and directed.Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. 131 M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium dutywith all accessories including fabricated 1.6 mm thick MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets,regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dollyincluding Cutting chase, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edgesall as specified for one light or fanpoint controlled by two twoway switchs for light point, 5 amps complete all as specified and as directed.Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. 132 All as per item No.131.00 mentioned here-in-before but using 4 sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board or for AC Starter including 4 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth leadcomplete all as specified and directed by Engineer-in-Charge. 133 Supply & fix Switch piano, flush type, SP, two way, 5/6 Amps 230/240 Volts, white/ivory finish for 10 watt led complete all as specified and directed. 134 Supply & fix Switch piano, flush type, SP, one way, 5/6 Amps 230/240 Volts, white/ivory finish complete all as specified and directed. 135 Supply & fix Bell/buzzer push 5/6 amps, flush type, white/ivory finish complete all as specified and as directed. 136 Supply and fix Socket outlet 3/5 pin, 6 Amps, 240 volt flushtype complete all as specified and as directed. 137 Supply and fix Switch socket combination multipurpose 2 in 1, 3 pin 6 Amps 230/240 volt flushtype complete all as specified and as directed. 138 Supply and fix Switch socket combination multipurpose 2 in 1, 3 pin 5 & 15 Amps 230/240 volt flushtype complete all as specified and as directed. 139 Supply and fix Ceiling rose surface bakelitethree terminals 240 volts complete all as specified and as directed. 140 Supply and fixing ceiling Fan regulator step type240 Volt complete all as specified and directed by the Engr-in-Charge. 141 Supply and fix Call bell ding dong AC 230 volts, single pole complete all as specified and as directed. 142 S&F A C starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top prewire complete all as specified and directed by Engineer-in-Charge. 143 Supply and fixing Lamp holder suitable for batten fittings complete all as specified and directed by the Engr-in-Charge. 144 S&F LED light fitting mirror type of with high out put diffuser 2 feet,capacity 10W, 220V,decorative type with driver holder complete with LED tube Lamp including connecting up with three coreflexible copper conductor of suitable sizeincludingtaking down old unserviceable one complete all as specified and as directed. 145 S&F Energy efficientLED fittings of capacity 20W suspended type / wall mounted type complete with LED tube Lamp and fitting with copper flexible PVC cable of 0.50 sq mm twin core not more than one metre in lengthincludingtaking down old unserviceable one complete all as specified and as directed. 146 S&F Energy efficient LED fittings of capacity 10 W suspended type / wall mounted type complete with LED tube Lamp and fitting with copper flexible PVC cable of 0.50 sq mm twin core not more than one metre in lengthincludingtaking down old unserviceable one complete all as specified and as directed. 147 Supply & fixLED Building security light 25/30 watt in aluminium PDC housing, toughened glass cover with IP66 protection with 0.5 mtr GI pipe of suitable size making connection with PVC cable of 0.50 sq mm three core sheatered not more than 0.5 meter in lenght complete all as specified and as directed. 148 Taking down old burnt/unserviceable submain wiring with aluminum/copper conductor PVC insulated cable of any size drawn through PVC concealed conduit including GI wire accessories etc. and making good disturbed surfaces of walls, floors, etccomplete all as specified and directed. 149 Materials and labour Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 4.0 Sqmm as earth lead drawn in and including PVC concealed conduitof suitable size including all fittings complete all as specified and as directed.Note:- Two runsof 4.0 Sqmm conductor as main wireand one run of 4.0 Sqmm conductor as earth wire with one run of PVC concealed conduit shall be measured as one unit. 150 Materials and labour Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 6.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 6.0 Sqmm as earth lead drawn in and including PVC concealed conduit of suitable size including all fittings complete all as specified and as directed.Note:- Two runsof 6.0 Sqmm conductor as main wireand one run of 6.0 Sqmm conductor as earth wire with one run of PVC concealed conduit shall be measured as one unit. 151 Taking down unserviceable rusted / damaged MCB DBs of any type and way along with any type MCB and keeping serviceable MCB in safe custody in re-use in the work and making good to the distubed surfaces of walls etc. complete all as specified and as directed. 152 S&F Sheet metal enclosure for DBs when MCBs to be used 8 way single pole and neutral double door with 200 amps ratedbus bar complete 240 volts complete all as specified and as directed. 153 S&F MCB TPN DB double door made up with sheet metal, phosphorised, power coated, neutral link, earth bar and din rail, 4 way TPN with 200 amps rated bus bar, 415 volts complete all as specified and as directed. 154 Supply and fix MCB 32 Amps, DP 240 Volts , C curve braking capacity 10 kAcomplete all as specified and as directed. 155 Supply and fix MCB 6 to 32 Amps, SP, 240 Volts , C curve braking capacity 10 kAcomplete all as specified and as directed. 156 Supply and fix MCB TPN 100 Amps, 415 Voltswith rupturing capacity 10 kA ,C curvecomplete all as specified and as directed. 157 Supply & Fixing in repair capacitor of 2.5 mfd ,240 volts.AC, 50 Hz complete all as specified and directed. 158 Taking down and opening out the blades of ceiling fan/wall mounted fan/ exhaust fan of any sweepfor cleaning and refixing of fan at same location or any other situationafter minor repair complete all as specified and as directed. 159 Taking down and refixing electric water heater of any capacity with cromium plated copper pipe complete complete as directed. 160 Materials and labour Earthing complete with galvanised steel earth plate electrode 60 Cm x 60 Cm x 6.00 mm thick buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip projection by 15 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 Cm c/c both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I including taking out of old unserviceable earth pit with all accessories complete all as specified and as directed.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 45.64 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail