Tender For First floor construction and completion of Community Hall for Pananchery Grama Panchayath -Phase - 2 - Electrical Works - 1Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 3 90.6.10.2Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 4 90.6.10.3Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm 5 90.9.1.1Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required. 50x50mm Cable Management System with base and lid 6 90.9.1.7Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap 7 90.9.2.1Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid 8 90.9.2.8Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required. End cap 9 OD293097/2025-2026Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit as required.Group B 10 1.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 11 90.3.21.3Supply & installation of light fittings on C/U shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories andlamps etc. directly on wall using 2 nos. C/U brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm1X20W LED Lamp with box type fixture 12 90.3.20.3Supply & installation of light fittings on TW round blockSupply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture 13 90.3.23.5.4Surface mounting decorative fluorescent tube light fitting complete with lamp with complete accessories duly wired up for use on 230 V AC .Surface mounting LED 40W LED Batten with out put 4000 lumen for use on 250V AC supply. 14 90.3.11Conveyance, installation, testing and commissioning of surface mounting down light fittings of all types directly on ceiling including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required. 15 90.3.2Conveyance installation testing and commissioning of pre-wired fluorescent fittings of all types complete with all accessories and fluorescent lamps etc. directly on wallor ceiling with Suitable size PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and givingconnections as required. 16 OD293519/2025-2026Supplying of 1800 lumen round/ square surface mount fitting made of diecast aluminium, having efficacy not less than 100l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea 17 OD293520/2025-2026Supplying of 3600 lumen square (2ft X 2ft) recessed fitting made of crca sheet of thickness 0.5mm, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea (UGR less than 19) 18 OD293521/2025-2026Supplying of 1800 lumen round/ square(1X1) recessed fitting made of diecast aluminium, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea etc as required. 19 90.15.4.3Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree /Lumilled /Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 20 90.15.4.6Supply Conveyance, installation, testing and commissioning of 70W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree /Lumilled/ Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartmentshould be seperatly accessible for maintenance (LM 79& amp;80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 21 90.3.18.3Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat 22 1.58Supplying and fixing PVC batten/ angle holder including connection etc. as required. 23 OD293094/2025-2026Supplying and providing LED Bulk head fitting with E27 holder and giving connection with 16/0.24 mm PVC insulated and sheathed copper flex wire conforming to relevent ISS etc as required. 24 OD293087/2025-2026Supplying and providing 7W LED bulb on the existing holder etc as required. 25 OD293108/2025-2026Supply,Conveyance, installation, testing and commissioning of mirror light fittings directly on wall including giving connections with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or with theextended original wiring, making good the damages, colour washing etc as required. 26 OD293110/2025-2026Supply,Conveyance, installation, testing and commissioning of ornamental wall light fittings with E27 holder directly on wall including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required. 27 90.4.1Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. 28 19.1Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min, 350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required: 29 1.48Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) 30 90.4.8Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. 31 OD293090/2025-2026Supply of 305 mmheavy duty exhaust fan complete with standard accessoreies suitable for single phase 230V,50Hz a.c. supply (Almonard/equivlant make) etc as requird . 32 OD293092/2025-2026Supply of 8/9metal leaf exhaust fan complete with standard accessoreies suitable for single phase 230V,50Hz a.c. supply (Almonard/equivlant make) etc as requird . 33 1.50.1Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep 34 1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 35 1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 36 1.27.4Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) 37 1.27.5Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) 38 1.27.6Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm) 39 1.24.1Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch 40 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 41 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 42 1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet 43 90.10.3.15Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator 44 90.10.3.32Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator 45 90.10.3.33Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) 25A 3pinShuttered socket 46 1.26Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 47 1.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 X 1.5 sq.mm 48 1.17.4Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm 49 1.17.5Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 5 X 1.5 Sq. mm 50 1.17.6Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm 51 1.17.12Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm 52 1.17.21Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm 53 90.6.5.9Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 0.75 sq mm 54 4.1.4Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness 55 90.12.7.28Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 56 90.12.10.3Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size 57 90.12.7.29Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp 58 90.12.7.39Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 6 sq mm with factory made clamp 59 90.12.41.31Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp 60 90.12.7.41Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 61 90.12.7.2Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 62 9.1.21Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductorcableof 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) 63 9.1.33Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 64 9.1.22Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1KV grade as required.3 1/2 X 50 sq. mm (35mm) 65 9.1.32Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) 66 9.1.1Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated andPVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 67 OD293105/2025-2026Supply and providing earth clamps for siemens / tropodor type cable glands of suitable length and other dimensions noted along with each size of glands as required. 4 sqmm to 16 sqmm with 12mm widex1 mm thick clip. 68 OD293088/2025-2026Supplying and providing copper earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required.25sqmm-95 sq mm with 12 mm wide x 1 mm thick clip 69 2.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door 70 90.11.1.10Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 71 90.11.1.11Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43) 72 90.11.1.15Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) 73 2.11Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 74 2.16Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts C curve DP MCB complete with connections, testing and commissioning etc. as required. 75 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps 76 2.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps 77 2.13.2Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps 78 2.14.1Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required. 25 amps 79 2.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps 80 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, Ccurve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 81 2.10.4Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 82 90.14.2.2Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc. 83 90.14.1.2Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) 84 90.14.3.1Supply and providing heavy duty A section neoprene gasket in the panel board A section neoprene beeding suitable for 1.60/ 2.00 mm sheet 85 90.14.4Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC) 86 90.14.6Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required. 87 90.14.7Supply and providing copper earth bus in the panel board 88 OD293093/2025-2026Supply and providing 2.mm thick 3.3KV synthetic elesromeric fire retardent insulating sheet in front of main board etc as required. 89 90.14.5Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board 90 90.14.10.10Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16A -100A, 35/36 kA Ics =100% Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC 91 90.14.10.3Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL 92 OD293104/2025-2026Supply and providing 105 A 4 pole power contactor on the existing enclosure and giving connection etc as required . 93 OD294273/2025-2026Supply and providing selector switch on the enclosure and giving connection etc as required . 94 OD294274/2025-2026Supply and providing electronic timer upto 120Sec and giving connection etc as required . 95 OD294275/2025-2026Supply and providing Add on module and giving connection etc as required . 96 OD294276/2025-2026Supply and providing AMF relay on the existing enclosure and giving connection etc as required . 97 90.14.11.12MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A. 98 90.14.11.14MCCB AccessoriesSupply and fixing rotary handle, Direct type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A 99 OD293107/2025-2026Supply and providing spreader terminals suitable for MCCB upto 100A 100 OD293106/2025-2026Supply and providing three phase multifunction meter to read VAF of 3 phase class1 101 90.14.11.5MCCB AccessoriesSupply and fixing 100 - 200A earth fault module of MCCB with builtin CBCT. 102 OD293095/2025-2026Supply & fixing 100/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT 103 OD293099/2025-2026Supplying and fixing 2 amps rating, 240/415 volts, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole 104 OD293101/2025-2026Supplying and providing red/green/orange colour LED indicator lamp AC/DC 22.5mm diain the existing panel and giving connection etc. as required. 105 OD293102/2025-2026Supplying and providing blue colour LED indicator lamp AC/DC 22.5mm diain the existing panel and giving connection etc. as required. 106 5.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 107 OD293109/2025-2026Supply and providing test joint for plate earthing using 2nos 25x6 mm GI strip on the watering pipe of the plate earthing on both side using 25x6 mm SS bolt and hut with washer etc as required . 108 90.16.1.6Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required6.00 mm copper conductor (4 SWG) 109 5.9Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 110 90.16.1.1Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG) 111 90.16.1.2Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) 112 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) 113 90.16.5.1Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG) 114 90.16.5.3Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) 115 90.16.5.2Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required 2.65. mm (12 SWG) 116 OD293098/2025-2026Supply and providing the following sizes of bolt and nut with washers on the existing M.S box/ earth bus etc. as required including drilling necessary holes as required. 25x6mm brass nut and bolt . 117 OD293103/2025-2026Supply and providing the following sizes of bolt and nut with washers on the existing M.S box/ earth bus etc. as required including drilling necessary holes as required. 12x3mm brass nut and bolt . 118 OD293096/2025-2026Supply and providing MS eye bolt hook in wall/parapet for binding support for KSEB service wire connection 119 OD293091/2025-2026Charges for collecting the load details in the entaire building and prepare drawing for submitting to KSEB/KSLB along with test report including obtaing NOC from KSLB etc as required 120 OD293089/2025-2026Supplying and providing Fire extinguisher on the existing wall using suitable hook etc as required .(CO2 -2/3 Kg) 121 OD293100/2025-2026Supplying and providing 100 A 2 Way N/L on the existing box and giving connection etc as required . 122 OD293086/2025-2026Supplying and providing 100 A HRC fuse unit with fuse on the existing box and giving connection etc as required . 123 OD295175/2025-2026Supply and installation of dust and vermin proof wall mounting SMC Meter box suitable for fixing KSEB Meter, cut out Neutral link etc, hinged door construction for the front side , providing vision panel, for the meter compartment, knock out for cable entry and exit. GS-MB 6535 (inside 650x350x250 Sintex or its equivalent. 124 2.13.3Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 amps 125 OD295263/2025-2026Supplying and providing SPD -type 1+2 -(I max -100KA) 4 module in the existing panel and giving connection etc. as required. 126 OD294432/2025-2026Supply, Loading, Conveyance, Unloading, Erection, Testing and Commissioning of 40/nearest KVA DG Set withAcoustic enclosure as per CPCB 4+ norms and as detailed below . (1). Engine (a). Make of engine - Cummins / Caterpillar /Leyland. (b). Type of Engine - Diesel Engine.(c). No of Cylinders -As per manufactures standars.(d). Method of cooling - Water cooled with radiator.(e). Aspiration- Naturally Aspirated.(f). Design - Suitable for generating set operation.(g). Output - Suitable forgenerating set operation.(2). Standard accessories with Diesel Engine. (a). Fly wheel.(b).Close Coupled.(c). Air cleaner.d). Raditor with fan provided with fan guard.(e). Fuel Pump.(f). Mechanical governor.(g). Fuel filter.(h). Lubricating oil filter.(i). Residentialtype exhaust silencer. (j). Battery Charger / Generator.(3). Engine Instument Panel with thefollowing items.(a). Starting switch with key or button (b). Lubricating oil pressure gauge.(c).Water temperature gauge.(d). RPM Indicator with hour meter. (e). Battery charging ammeter.(4). Saftey Controls for Engine. (a). Battery control (trip) for low ludricating oil pressure.(b).Battery control, (trip) for high water temperature. (5). Brushless alternator. (a). Make - Stamford/BHEL /Leroy somer. (b). Type - Self exited and self regulated. (c). Capacity -60 KVA/ 48 KW @0.8PF. (d). System of Voltage - 3Phase, 415V, 4Wire system.(f). Speed - 1500 rpm.(g).Frequecncy - 50Hz.(h). Insulation - Class F/H.The alternator should confirm to IS4722/ IS13365. Operation and service manual shall be provided. (6). Fuel Tank. Suitable sizefitted (built in type) inside the acoustic enclosure. (7). Battery. Suitable size fully charged batterywith leads and terminals of appropriate AH capacity as per Manufactures required including batterycharger.(8). Standard control panel. (a) 63 4Pole MCCB Set at 56 A and stand by low set earth fault relay using suitable size neutral CT. (b). 1No multifunction meter suitable for display of currentin 3Phases, voltage in 3Phases, frequency, power factor, KVA, KVAh, KVAr, KVArh,KW etc. (c).1No separate KWH meter (d). Necessary measuring CTs of appropriate ratio and burdon for therequired meter.(e). Instrument fuse/MCB (f). Metallic DNB - 1No.(g). Solid state phaseindication lamp for supply ON/OF with Fuse / MCB protection. (9).Warrantee. 3 Years . 127 OD295140/2025-2026Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitableclamp or support frame and painting with two or more coats of heat resistant paints of required shades complete as required as extension of exhaust pipe of DG Set: 65mm dia 128 14.1Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. 129 14.7Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. 130 14.11Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels. 131 14.12Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels