| 1 | building work |
| 2 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 3 | 9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding |
| 4 | 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 5 | 8.2.2.2:Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm |
| 6 | 8.31:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 7 | 11.41.1:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm. |
| 8 | OD334286/2025-2026:Supplying and fixing stainless steel metal name letters of 15cm to 25cm size range (24 gauge) including all charges etc complete. |
| 9 | OD334287/2025-2026:Supplying and fixing stainless steel metal name letters of 25cm to 35cm range including all charges |
| 10 | OD334288/2025-2026:Modified 25.7 -Designing, fabricating, testing, installing and fixing in position Curtain Wall with Wooden grained AluminiumComposite Panel Cladding, with open grooves for linear as well as curvilinear portions of thebuilding , for all heights and all levels etc. including: a) Structural analysis & design andpreparation of shop drawings for pressure equalisation or rain screen principle as required,proper drainage of water to make it watertight including checking of all the structural andfunctional design. b) Providing, fabricating and supplying and fixing panels of aluminiumcomposite panel cladding in pan shape in metalic colour of approved shades made out of 3mmthick aluminium composite panel material consisting of 2mm thick FR grade mineral coresandwiched between two Alumini um sheets (each0.5mm thick). The aluminium compositepanel cladding sheet shall be coil coated, with Kynar 500based PVDF / Lumiflon basedfluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service)coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weathersilicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5 / MSwith Hot Dip Galvanised with serrations and serrated washers to arrest the wind loadmovement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylonseparators to prevent bi-metallic contacts all complete required to perform as per specificationand drawing The item includes cost of all material & labour component, the cost of all mockups at site, cost of all samples of the individual components for testing in an approvedlaboratory, field tests on the assembled working curtain wall with aluminium composite panelcladding, cleaning and protection of the curtain wall with aluminium composite panel claddingtill the handing over of the building for occupation. Base frame work for ACP cladding ispayable under the relevant aluminium item.s The Contractor shall provide curtain wall withaluminium composite panel cladding, having all the performance characteristics all complete ,as per the Architectural drawings, as per item description, as specified, as per the approved shopdrawings and as directed by the Engineer-in-Charge. However, for the purpose of payment,only the actual area on the external face of the curtain wall with Aluminum Composite PanelCladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 11 | 10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 12 | 50.12.5.1:Providing and fixing false ceiling with e board classic tile or equivalent make of size 610x610x4 mm ceiling of approved quality in aluminium frame work with necessary screws etc complete ( aluminium frame work shall be paid separately) |
| 13 | 10.26.1:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube |
| 14 | 50.17.1.3:Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 15 | 50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. |
| 16 | 50.18.7.2.1:Providing and fixing PVC pipes, fittings including fixing the pipe with claps at 1.00 metre spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 12Kgf/cm2 - Internal work - Exposed on wall |
| 17 | 13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |