Tender For Additional Electrical Work At Medical College, Karauli - (Based on Rajasthan PWD Electrical BSR 2013 Jaipur & NBSR) 2 P/Laying P.V.C./ XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 3 6.0 Sq.mm 4 4 core 5 10.0 Sq.mm 6 4 core 7 16.0 Sq.mm 8 4 core 9 35.0 Sq.mm 10 3.5 core 11 150.0 Sq.mm 12 3.5 core 13 400.0 Sq.mm 14 3.5 core 15 Supplying and makingend termination with heavy aluminiumlugs ( Pin / ring type ) duly crimped with crimping tool, PVC tape etc of following size. 16 1.5 Sq.mm 17 2.5 Sq.mm 18 4.0 Sq.mm 19 6.0 Sq.mm 20 10.0 Sq.mm 21 Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. 22 4 x 6.0 sq.mm 23 4 x 10.0 sq.mm 24 4 x 16.0 sq.mm 25 4 x 25.0 sq.mm 26 Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , Painting etc. as required. 27 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 28 M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 40mm nominal size). 29 Providing, laying, testing & Commissioning ofC class heavy duty MS pipe conforming to IS 3589 / 1239 for hydrent and sprinkler applicationsincluding fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and including painting of two coats of Red Oxide , painting with two or more coats of synthetic enamel paint of Post office redshade complete as required.The installation includes all civil openings ,breakages and making good the same. 30 100 mm dia 31 Providing, installation, testing and commissioning of dual plate non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, G I bolts, nuts, washers etc. as required. 32 150 mmdia 33 Supplying, fixing, testing commissioning of butterfly valve PN 1.6, with Bronze/ Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS 13095, of following sizes as required. 34 100mmdia 35 Providingandconstructingmasonrychamber 90 x90x100cms inside withbrick work in cement mortar 1:5 (1cement : 5fine sand) for water meter ,M.S. cover (6mmthick sheet with locking arrangement, 600 x600 with M.S. frame etc. all epoxy coated and R.C.C. top slab 1:2:4 mix(1 Cement : 2 coarsesand : 4 graded stone aggregate 20mm nominalsize) including necessary excavation, back fillingfoundation concrete 1:5:10 mix (1 cement : 5 fine sand and10 graded stone aggregate 20mmnominal size) leaving a pocket of 30x30 cmwith out concrete and filled with pebbles andinside plastering withcement mortar 1:3(1 cement : 3 coarse sand) 12 mm thick finishedwith a floating coat of neat cement and outside plaster finished rough complete. 36 S & F of Electricalinsulating rubber mattsconfirming to IS: 15652 /2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. 37 33 KV,3 mm thick with proof voltage 36 KV / 3 min. and Break Down Voltage 65 KV 38 SITC of ISI marked Submersible mud pump set minimum 20 mm solid handling 2900 RPM , three phase, 415 V, 50 Hz, having following capacity. 39 1 HP, ( 14 - 7.5 ) Mtr. (60 - 300) LPM 40 P&F of Heavy duty capacitor start, Double ball bearing900/1400 RPM single phase ISI marked Exhaustfan,IS:2312 marked in existing opening including making connections testing etc. as required. 41 300 mm sweep(900/1400 RPM) 42 P , Laying &Jointing R.C.C. class NP-2 (Non pressure) pipes (IS:458) with collars. Jointed with cement mortar of ratio 1:2 including excavation etc. as required. 43 200 mm dia internal. 44 300 mm dia internal. 45 Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed: 46 Hard rock (requiring blasting) useful material 30% 47 NON BSR : SITC of Surface Bollard light with minimum 400 system lumens and maximum wattage of 8W ,AluminumDie-castingbodywithPolycarbonatecoverwithaheightof minimum 700mm (approx), suitable for Garden / Area lighting; Offering IP-65 or above for outdoor application suitability. Rated Input Supply of LED AC 240V, 50Hz Voltage power supply which drives the LEDs, High Power LED Make : CREE / LUMINOUS / OSRAM / SAMSUNG / NICHIA / SEOUL / LUMILEDS.RatedInputSupplyofLED:Highlyreliable AC150-270V, PowerEfficiency:>85%,Powerfactor:>0.9,OperatingFrequency:50Hz, Operatingtemperature:0 to +45degreecentigrade,OutputColor:WW,Life Span : ≥ 50000 hours, Electrical Safety Class : Class1. Fixture should have driver and other related accessories as per site requirement. Makes ; Philips / Wipro / Trilux / Schreder / Havells / Glomac /Ligman / Ledlum/Crompton. 48 BSR 2022 49 Providing and Fixing of PN16 Resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 8.5 Kg/cm2 and test pressure 14 Kg/cm2 to provide relief from stresses at pipe including Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following Sizes.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 50 100 mm Dia. x 150 mm Oal 51 150 mm Dia. x 150 mm Oal