| 1 | Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2018-1131 (A) |
| 2 | Supply & fixing of CO2 type fire extinguisher,6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2018-1132 (A) |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 4 | Filing of carted earth |
| 5 | Sand filling in plinth under floors including watering, ramming, consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including cost of sand. |
| 6 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 7 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor :With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 8 | Class 150 brick work in 1:6 Cement and coarse sandinFM 2.25 mortar in foundation and plinth including supply of all materials, labour and T & P etc. required for proper completion of the work as per direction of E / I. |
| 9 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 12.5 mm nominal size). |
| 10 | Same as in item No.5 abovebutin super-structure above plinth level up to floor two level (up to two storeys) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand). |
| 11 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand) |
| 12 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) (FOOTING) |
| 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (R.C.C. BEAMS) |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (R.C.C. BEAMS) |
| 15 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) (R.C.C. COLUMNS) |
| 16 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (R.C.C. SLAB) |
| 17 | Mild steel or iron in plan work shch as reinforced concrete or reinforced brick (when not included in over all rates) brought to require shape as necessary and also including being for proper completion of work and including supply of all steel and wastage & over lapping & hooks. |
| 18 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M. 2.25 |
| 19 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand. F.M. 2.25 |
| 20 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 21 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate(room and Godown) |
| 22 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, .hardening compound mixed @ 2 litre per 50kg of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete |
| 23 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick |
| 24 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 25 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 26 | Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade. |
| 27 | Distempering withoilboundwashable distemperof approvedbrand and manufacturer in desired shadeto give an even shadecompleteon new work ( two +one more coats )over and including priming coat. |
| 28 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand &anufacturer, over the plastered wall surface to prepare the surface even & smooth complete. |
| 29 | Supply & fixing, Fabrication of Angle iron door chaukhat (40*40*5 mm) |
| 30 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 31 | S/F Z- setion window |
| 32 | M.S. grill for window |
| 33 | Providing & fixing mosquito proof heavy quality iron wire gauge of expended metal heavy quality over windows.(B77 |
| 34 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 35 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 36 | DOOR |
| 37 | WINDOW |
| 38 | VENTILATOR |
| 39 | making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120mm and minimum thickness at khurra as 65 mm |
| 40 | S/F of 4.0 mm thick glass panes for window shutter incluing supply of puty, brand & spring all material labour T&p etc. |
| 41 | Supply of glass strips for flooring.40mm wide & 4 mm thick |
| 42 | Providing alluminiumslidingbolt anodised transparent or dyed to requered colour &shed with necessary screw etc. |
| 43 | Providing alluminiumtowerbolt anodised transparent or dyed to requered colour &shed with necessary screw etc. |
| 44 | Providing & fixing alluminium handle. |
| 45 | Supply andfixingrollingsuttersof approved make madeof 80*125 mm(3\"*18 gauge) cold rolled MS Lath interlocked through theirentire length andjoined together at the end by locks and mounted on specially designedpipeshaftwith brackets,side guides and arrangements for inside and outside locking with push and pull operationcomplete including the cost of top cover and spring. |
| 46 | Providingandfixingball bearing for rollong shutters . |
| 47 | Making of Drain Along Apron(230x230) |
| 48 | (a) Suspended floors, roofs, landings, balconies and access platform |
| 49 | (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 50 | (d) Foundations, footings, bases of columns, etc. for mass concrete |
| 51 | (e) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 52 | White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests |
| 53 | Flat back Wash Basin size 550X400 mm with single 15mm C. P. brass pillar tap |
| 54 | 32 mm dia (for wash basin) |
| 55 | Providing & Fixing 600 X 450 mm bevelled edge mirror of superiorglass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 56 | 100mm dia PVC Pipe 6 Kg Pressure |
| 57 | 75mm dia PVC Pipe |
| 58 | 100 mm inlet&75 mm outlet |
| 59 | 100 mm dia |
| 60 | 75 mm dia |
| 61 | 100 mm dia |
| 62 | 100 mm dia |
| 63 | Providing and fixing to the inlet mouth of rain water pipe grating 15 cm diameter |
| 64 | 150 mm dia |
| 65 | 150 mm dia bend (43 kg) |
| 66 | 90 mm size |
| 67 | 110 mm size |
| 68 | Supply and fixin g of UPVC S.W.R. Nahni trap size 100/75mm, 100/90mm confirming to IS - 14735 self cleannig design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty CP brass jali. |
| 69 | 15mm dia nominal bore |
| 70 | 20mm dia nominal bore |
| 71 | 15 mm nominal bore |
| 72 | Providing&fixing15 mm nominal bore45 cm long unplasticised PVC connection pipewith brass unions. |
| 73 | Providing & fixing 15 mm nominal bore CP brass bib cockof approved quality conformingtoIS 8931. |
| 74 | Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. |
| 75 | 250 litrescapacity |
| 76 | 15 mm. dia nominal bore |
| 77 | 15 mm. Diameter pipe |
| 78 | 25to 40 mm.Nominalbore |
| 79 | Constructing brick masonry chamber 300 x 300x500mm, insidewithF.P.S. brick work in cement mortar 1: 4 (1 cement : 4 coarse sand) for StopCock, withC. I. surface box 100 x 100 x 75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4mix (1cement : 2 coarse sand:4 grade stone aggregate 20mm nominal size); necessary excavation, foundationconcrete 1:5:10 (1 cement :5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar1 : 3 (1 cement : 3 coarse sand )12mmthick finished with a floatingcoatof neat cementcomplete as per standard design |
| 80 | Pipes 80 mm to 300 mmdiameter |
| 81 | 150 mm diameter |
| 82 | 150 mm diameter |
| 83 | Inside size 90 x 80 cm & 45 cmdeep including CI cover with frame (light duty) 455 x 610mm internal dimension total wt. of cover & frame to be not lessthan 38 kg (wt. of cover 23 kg and wt. of frame 15 kg) |
| 84 | For pipes 100 to 230 mm diameter |
| 85 | 180 x 150 mm. size P type |
| 86 | a) 110mm diameter |
| 87 | a) 110mm diameter |
| 88 | a) 110mm |
| 89 | 15 mm nominal bore |
| 90 | 20 mm nominal bore |
| 91 | Earth Work in excavation over areas including disposal of excavated earth lead upto 50 m disposed earth to be levelled and neatly dressed . In all kind of soil upto 1.5 m dept. |
| 92 | Providing and laying in cement concrete 1:4:8 (1 cement : 4 fine sand : 8 graded Stone ballast 40 mm nominal size) and curing complete, including cost of form- work, in foundation. |
| 93 | Brick work with brick of class designation 150 in foundation & Plinth in cement mortar (1 cement : 6 coarse sand ) septic tank Baffil wall |
| 94 | Reinforced cement concrete work in slab cover for septic tank1:1.5:3 |
| 95 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 96 | 40mm thick flooring. |
| 97 | 20 mm thk Plaster with neat cement finish |
| 98 | (a) Suspended floors, roofs, landings, balconies and access platform |
| 99 | Providing M.S. foot rest including fixing with 20 x 20 x 10 cm cement concete block 1:3:6 (1 cement : 3 coarse :6 graded aggregate of nominal size 20 mm ) as per standard with 20x20 mm sqm. bar. |
| 100 | 75 mm dia sand cost iron S&S pipe. |
| 101 | Providing & fixing sand cost iron terminal guard 75 mm dia. |
| 102 | Providing & fixing C.I. tee at the inlet & outlet of septic tank. |
| 103 | Providing & fixing plane sand cost iron S&S bend of required degree.75 mm |
| 104 | Providing lead caulked joints to sand cost iron/ cetrifugally cast (squn) irons pipes & fitting of dia. 75 mm |
| 105 | Supply & fixing of medium quality R.C.C. Manhole coverwith frame complete.HD.-20-Circular shape ,450 int. dia. |
| 106 | M.D.-10- square shape ,450 int. dia. |
| 107 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation M-150 |
| 108 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 109 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 110 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 111 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 112 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 113 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 114 | 3 pin 5/6 A socket outlet |
| 115 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 116 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 117 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 118 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 119 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. (for A.C. Point/MCB Point) |
| 120 | Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door |
| 121 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 122 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 123 | Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A |
| 124 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 125 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 126 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 127 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 128 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required |
| 129 | Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA |
| 130 | Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA |
| 131 | Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 10 sq mm x 2core |
| 132 | Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 10 sq mm |
| 133 | Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. |
| 134 | S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. |
| 135 | Supply & fixing of 230/250V (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), 300 mm sweep 900 rpm. Complete in all respect. |
| 136 | Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect. |
| 137 | along with paerapets to allow unhindered longitudinal |
| 138 | of water (as per sheer attached |