Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-10-2025 | Technical Bid Corrigendum | Technical Bid | 10-10-2025 |
| Sl. No. | Item Description |
| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 2 | Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50m)ByMechanical Means |
| 3 | Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) By Mechanical Means |
| 4 | Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. |
| 5 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compactionetc. complete.. |
| 6 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper.. |
| 7 | Providing soling using 80 mm size trap metal in 15 cm. layer including filling voidswith Crushed sand/grit, ramming, watering etc. complete.. |
| 8 | Ground Floor Plain Cement Concrete Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 9 | Ground Floor Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneissmetalforbedblocks,foundationblocksand suchotheritems including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 10 | Ground Floor Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 11 | Ground Floor Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 12 | Ground Floor Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 13 | Ground Floor Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade) |
| 14 | Ground Floor Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 15 | Ground Floor Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.. |
| 16 | Ground Floor Structural Steel Work Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.. |
| 17 | Ground Floor Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. |
| 18 | Ground Floor Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete..Spec. No. As director by engineer in charge andBDG- 2 and 5. |
| 19 | Ground Floor Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffoldingetc. Complete. |
| 20 | Ground Floor Plastering & Pointing Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. |
| 21 | Ground Floor Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grainsandcuringforfourteendays scaffolding etc.complete. |
| 22 | Ground Floor Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. |
| 23 | Ground Floor Paving, Flooring & Dado Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumenetc. complete. |
| 24 | Ground Floor Oil Painting Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.. |
| 25 | Ground Floor Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete |
| 26 | Ground Floor Providing and applying three coats of water proof cement paint of approved manufacture and of approved colour to new plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete. |
| 27 | Ground Floor Doors & Windows Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glasslouvers,of approved quality etc. complete. |
| 28 | Ground Floor Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (Without mechanical gear) |
| 29 | Ground Floor Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear) |
| 30 | Ground Floor Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 9501050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) Spec. No. As directed by Engineer in charge. |
| 31 | Providing and fixing lioghtening conductor system comprising of erecting AirTermination consisting of tubular copper rod of 25mm dia. 1.2 mm thick with multiple points head 1.2 mt. long ( Heavy Duty) welded or clamped to G.I. pipe pole B grade 50 mm diaof requiired length with M.S. round bnase plate 25 Cm diam and 10mm thick at bottom embeded in cement concrete 1:3:6 dfoundation of size 45 cm diam x 45 cm Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 cms with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40Kilogramcharcoal and salt with altemate layers of charcoal and salt and G.I.pipe 40mm dia 2 meter length burried in earthe upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item... |
| 32 | Ground Floor Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Spec No. As directed by Engineer Incharge. |
| 33 | Ground Floor PEB STRUCTURE upplying, fabricating, erecting and fixing in position of steel structures at all elevations using fusion welding quality steel E-350 (Fe490) conforming to 18:2062-2006. Rate shall include cost of cutting, welding, splice plates and packing plates, transporting, straightening, cleaning, fabricating and erecting in position welded/bolted Structural steelwork in columns, beams, trusses, purlins, platforms, ladders, monorails, staircases supports, strengthening of steel members etc. at site to line and level, supply of approved bolts/nuts/washers etc. complete as per drawings including painting as per G4/G5/G6 before erection and all materials and labour charges etc., complete and including Sand blasting & painted with 1 coats of enamel paint (Berger EPILUX SG-HHI 664002) of 35-50 micron each coat with air less spray gun over a coat of zinc chromate primer-35-50 micron etc., complete as shown in drawings, as per specifications and as directed by the Engineer-in-Charge/Construction Manager. (The rate quoted shall include cost of bolts, nuts, washers, welding and electrodes required for the complete work) |
| 34 | Supplying, fabricating and erecting of Cold Formet Light Gauge structural steel members, conforming to 1:801/ IS:811 hot-dip galvanised to 15:4759-96 including cutting, welding or bolting, splice plates and packing plates, transporting, straightening, cleaning, fabricating and erecting in position. |
| 35 | Supply & Fixing of PPGI sheets of 0.5 mm thick as shown in drawing or as directed by engineer inchuge with all necessary accessories. (Ensar) Make) |
| 36 | Supply & Fixing of 0.5 num the PPGL roof accessories as per drawing or as directed by engineer in charge. |
| 37 | Supplying, fabricating and erecting in position PPGI Eaves Gutter of required size with stop ends, all fixing accessories, drop ends, etc., at all elevations levels & heights including aligning, leveling, providing and fixing bolts, nuts, washers etc., conforming to latest specification including straightening, cutting, welding, bending to shape, bolting etc, complete and as directed as per engineer incharge |
| 38 | Providing and fixing of the rain water down take pipes of PPGI, the sectional area of rain water down take pipes provided shall be generally at the rate of 1 square cm per 70 to 80 square decimetre of roof area drained. No spout shall be less than 80 mm in diameter. The spacing of spouts shall be arranged to suit the position of openings in the wall including necessary accessories for fixing the pipe and including all materials and labour chargos etc., complete as shown in drawings, as per specifications and as directed by the Engineer-in-Charge |
| 39 | Supply & Fixing of turbo ventilator with 610 mm throat, having base ring & top plate in stainless steel of 0.8 mm thick, rotated using twin bearings of SKF-600122 & 600322 permanently lubricated & sealed. Fixed in FRP base plate of 2mm thk clear 1.020 mtr wide & 1.7 mtr long. |
| 40 | Supply & Fixing of 2mm the polycarbonate sheets as per drawing & as directed by engineer in-charge |
| 41 | Internal Concrete Road Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge , compacting with vibratory roller, finishing, curing andincluding preparation of sub-grade surface if required etc. complete. |
| 42 | Providing and laying in situ cement concrete M -30 with tremix treatment for 200 mm thickness for Concrete Road is including laying plastic sheet for 125 micron thicknesswith groove cutting of 4 mm wide and 20 mm deep with necessary refilling with bitumen( excluding reinforcement) with coarse and fine aggregate ( natural sand/ VSI grade finelywashed crushed sand) etc. complete with fully automatic micro processor based PLC withSCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete |
| 43 | Providing and fixing in position TMT FE 500, tie bars precoated with anticorrosive epoxy paint of 12 mm dia. 70 cms.long and at 30.00 cm. C/C and wherever directed including handling, straightening wrapping with paper of approved quality for half length, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete. |
| 44 | Supplying hard murum/ kankar at the road site, including conveying and stacking complete. |
| 45 | Spreading hard murum/ soft murrum/ gravel or kankar for side width complete. |
| 46 | Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete. |
| 47 | Eletrical Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ tfusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 48 | Ground Floor Making trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR |
| 49 | Ground Floor Making trench in Hard murum/Tar road having 0.75 m depth and minimum 0.3mtr width as per IS for laying provided cables up to voltage level 1.1Kv cable complete as per specification No. CW- EXN-CTR |
| 50 | Ground FloorSupplying and erecting mains with 3x2.5 sqmm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG- MA/BW |
| 51 | Ground FloorSupplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 10A, 2 pin plug & earth socket and 10A, 3 pin plug top with 10A single pole MCB having rated short-circuit breaking capacity (Ion) 10kA complete erected on angle iron/GI frame. |
| 52 | Ground Floor Point wiring for light/fan/bell in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification No: WG-PW/SW |
| 53 | Ground Floor Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22/E-27 base. |
| 54 | Ground Floor Supplying and erecting integrated LED street light fitting 18 to 22W IP65 & IK08 class having single piece pressure die-cast aluminium housing,having system lumens output of Min. 1800 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FGODF/FLS2. |
| 55 | Ground Floor Supplying and erecting Street light bracket made from 40 mm. dia \"B\" class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC |
| 56 | Ground Floor Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. ΕΑ-ΕΡ |
| 57 | Ground Floor Providing pipe type earthing with 40mm. dia. G.1. pipe or 20 mm dia. G.1. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 58 | Ground Floor Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short-circuit breaking capacity (Ien) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 59 | Ground Floor Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 60 | Ground Floor Supplying and erecting Gl sheet 1.6 mm (16 SWG) having zinc coating of 350 microns with galvanization process compliance to 15 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc, and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 61 | Ground Floor Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010 |
| 62 | Ground Floor Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no.SW-SWR/MCBDB1 |
| 63 | Ground FloorSupplying & erecting G.I. pipe \"A\" class 25 mm dia. erected for enclosing XLPE armoured cable on wall pole as per specification по. CB-CE |
| 64 | Ground Floor Supplying & erecting G.1. pipe \"A\" class 40 mm dia, erected for enclosing XLPE armoured cable on wall/pole as per specification по. СВ-СЕ |
| 65 | Ground Floor Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete |
| 66 | Ground Floor Supplying & erecting single compression type brass cable glands for 3 to 4 core 6 sq mm 2 to 4 core 10 sq mm for XLPE armoured cable as per specification No.CB-GL |
| 67 | Ground Floor Supplying and erecting Ceiling rose/Batten holder/Slanting holder /hanging cord switch/hanging bell push/pendant holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box. |
| 68 | Ground Floor Point wiring for independent plug in 20 mm metal conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG- PW/SW |
| 69 | Ground Floor Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW |
| 70 | Ground Floor Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places, as per specification No: WG- MA/BW |
| 71 | Ground Floor Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC Insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places, as per specification No: WG-MA/BW |
| 72 | Ground Floor Supplying and erecting modular type: D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 73 | Ground Floor Supplying, erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc.in provided distribution board. |
| 74 | Ground Floor Supplying & erecting 3W, 230V integral type LED Lamp suitable for B-22/E-27 base, |
| 75 | Ground FloorSupplying and erecting IP65 and IK08 rated UV shielded polycarbonate waterproof and dustproof industrial grade LED fitting (4 feet) max. 36W with high transitivity diffuser with system lumens output of min. 4300 lumens, min. efficacy of 120 lumen/W. CRE>80, CCT upto 6500K, Beam Angle of 120 deg, Ripple 5%, THD<10%, p.f. 0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70850, IP20 rated, including driver with auto cutoff & auto restart feature at 325V with end caps on PVC lock/wooden board with 3 years warranty. |
| 76 | Ground Floor Supplying and erecting regular standard model ceiling fan of 900 1050 mm, sweep complete erected in position as per specification no |
| 77 | Ground Floor Supplying and erecting ding dong/electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on olished double wooden block/sunmica block of suitable size. |
| 78 | Supplying and erecting Street light bracket made from 25 mm, dia \"B\" class G.L. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC |
| 79 | Ground Floor Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/Gl frame. |
| 80 | Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 40A in provided distribution 34 board. |
| 81 | For Sand |
| 82 | For Hard Murum |
| 83 | 1) Basic Test of Cement Carrying out basic tests on cement for standard consistancy, Fineness, Specific gravity, Setting time (Initial and Final), Compressive strength, Soundness. Spec. No. As directed by Engineer in Charge. |
| 84 | 2) Fine Aggregates Carrying out basic tests on Sand for Fineness modulus,Silt and clay content.Spec.No.As directed by Engineer in Charge. |
| 85 | Carrying out basic tests on Sand for chloride and sulphatecontent.Spec.No.As directed by Engineer in Charge |
| 86 | 3) Basic Test of Aggregates Carrying out basic tests on Aggeregates for Water absorption,specific gravity.Impact value,crushing value.Spec.No.As directed by Engineer in Charge |
| 87 | Carrying out basic tests on Aggeregates for Sieve Analysis.Spec.No.As directed by Engineer in Charge. |
| 88 | 4) Basic Test of Concrete Carrying out basic tests on Concrete cubes for compressive strength.Spec.No.As directed by Engineer in Charge |
| 89 | Carrying out basic tests on Concrete for Mix design.Spec.No.As directed by Engineer in Charge. |
| 90 | 5) Basic Test of Bricks Carrying out basic tests on Bricks for water absorptio, Efflorescence, compressive strength.Spec.No.As directed by Engineer in Charge. |
| 91 | ManagementStrategiesandImplementationPlan(MSIP)tomanagetheEnvironmental,Social, Health and Safety (ESHS) risks and ESHS Code of Conduct |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy