| 1 | Excavationforfoundationinearth,soilofalltypes,sand,gravelandsoftmurum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthe buildingareaand stackingandspreadingasdirected,dewatering,preparingthebed forthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means. |
| 2 | Excavationforfoundationinearth,soilsofalltypes,sand,gravelandsoftmurum, includingremovingtheexcavatedmaterialuptoadistanceof50metresbeyondthe building area and stackingandspreadingasdirected,dewatering,preparingthebed forthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means. |
| 3 | Providingdry/trap/granite/quartzite/gneissrubblestonesoling15cmto20cm thick including hand packing and compacting etc. complete. |
| 4 | Providing solingusing 80 mmsize trap metal in 15 cm. layer including filling voidswith Crushed sand/grit, ramming, watering etc. complete. |
| 5 | Filling in plinth and floors with contractorsmaterial/brought from outside and approved byEngineer inchargein layers of 15 cmto 20 cm including watering and compactionetc. complete. |
| 6 | Fillinginplinthandfloorswith approved excavatedmaterialin15cm.to20cm. Layers including watering and compacting etc. complete. |
| 7 | Providing and laying Cast in situ/ReadyMix cement concrete in M-10 of trap/ granite/quartzite/ gneiss metal for foundation and bedding including bailing out water, Steelcentering,formwork,laying/pumping,compacting,rougheningthemif special finish is to be provided,finishingifrequiredandcuringcomplete,withfully automatic micro processorbasedPLCwithSCADAenabledreversibleDrumType mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade). |
| 8 | Providingandlayinginsitu/ReadyMix cementconcrete M-20 oftrap/granite /quartzite/ gneiss metalforR.C.C.work infoundationslikeraft,stripfoundations, grillageand footingsofR.C.C.columnsandsteelstanchions etc.includingbailing outwater, Steel centeringformwork,laying/pumpingcoverblocks,compactionand curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). |
| 9 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to beprovidedandcuringetc.complete.(Excludingreinforcementandstructural steel).withfully automaticmicroprocessorbasedPLCwithSCADA enabledreversible DrumTypemixer/concreteBatchmixplant(Panmixer)etc.complete.Withfine aggregate (Crushed sand VSI Grade). |
| 10 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite/quartzite/gneissmetal forR.C.C.beamsandlintelsasperdetaileddesignsand drawings or asdirectedincludingsteelcentering,formwork,coverblocks, laying/pumping,compactionand roughening the surface if special finish is to be providedandcuringetc. complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversible DrumTypemixer/concreteBatchmixplant(Panmixer)etc.complete.Withfine aggregate (Crushed sand VSI Grade). |
| 11 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/ quartzite/gneissmetal forR.C.C.chajjaasperdetaileddesignanddrawingsincluding steel centering, formwork, cover blocks, laying/pumping, compacting androughening the surface ifspecial finish is to be provided and curing complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLCwithSCADA enabled reversible DrumType mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade). |
| 12 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters forR.C.C.pile caps,footings,foundations,slabs,beams columns,canopies, staircase, newels,chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs,drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 13 | Providing and fixing in position HCRM / CRS (CorrosionResistant Steel) bar reinforcement ofvariousdiametersforR.C.C.pilecaps,footings,foundations,slabs, beams columns,canopies, staircase, newels, chajjas, lintels pardis, copings, fins, archesetc.asperdetailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 14 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksin cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete. |
| 15 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksin cementmortar 1:6 in superstructure including striking joints, raking out joints, wateringand scaffolding etc. Complete. |
| 16 | Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.)for roofing without wind tiles including fastening with galvanised iron screws andbolts,leadandbitumenwashersasperdrawingetc.complete.(Weightof5.5 Kilogram/sq.m.). |
| 17 | Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:4 withoutneeru finish to concrete or brick surfaces, in all positionsincluding scaffolding and curing etc. complete. |
| 18 | Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:5 withoutneeru finish to concrete or brick surfaces, in all positionsincluding scaffolding and curing etc. complete. |
| 19 | Providinginternalcementplaster20mmthickin Singlecoatsincementmortar1:4 without neerufinish,toconcrete,bricksurface,inallpositionsincluding scaffoldingandcuring etc.complete. |
| 20 | Providinginternalcementplaster20mmthickin Singlecoatsincementmortar1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. |
| 21 | ProvidingandlayinginsitucementconcreteM20withtremixtreatmentfor100 mm thicknessforflooringwithgroovecuttingof4mmwideand20mm deepwith necessary refilling with bitumenetc. complete. |
| 22 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing,gussetplatesetc.asperdetaileddesignsanddrawingsoras directed including cutting,fabricating, hoisting,erecting fixingin position, Making riveted/ bolted/welded connectionandone coat of anticorrosive paint andover it 2 coats of oil painting approved quality and shade etc. complete. |
| 23 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre asperdrawing including fixtures,necessarywelding andpainting with one coatsof anticorrosive paint and two coats of oil painting complete. |
| 24 | Providing and applying washable oil-bound distemper of approvedcolour andshade to oldand new surfacesintwocoatsincludingscaffolding,preparingthesurfaces. (excluding the primer coat.) etc. complete. |
| 25 | Providingandapplyingtwocoatsoftexturedsyntheticpaintofapprovedshadeand quality andonecoatofprimerbeforeapplyingtexturedpaintincludingscaffolding ifnecessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete. |
| 26 | Providing and applying two coats of water proof cement paint of approved manufacture andofapprovedcolourtotheplasteredsurfacesincludingscaffoldingifnecessary, cleaning and preparing the surface, watering for two days etc.complete. |
| 27 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fittedwith sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S.Bracketplate300x300x3.15mmminimumsizeandshapewithsquarebar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mmthicknessandofanysizeattopandsafetydevicesincludingmechanicalgear operation arrangement consisting of worm gear wheels and worms of high grade cast iron ormildsteelandonecoatofredleadprimeretc.complete.(I.S.62481979)(Without mechanical gear). |
| 28 | Providing andfixing inposition(asper1868/1982)Aluminium sliding windowof three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window framebottomtrack section 92 x 31.75 x 1.30 mmat weight1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Runningmetre.Theshuttershouldbeof bearingbottom40x18x1.25mmat weight 0.417Kilogram/One Running Metre. Inter locking section 40x 18x 1.10mm atweight 0.469Kilogram/Running metre. andhandleandtopsection40x 18x1.25mm atweight 0.417Kilogram/Running metre. As per detailed drawings and as directed byEngineerincharge withallnecessary Aluminium sectionsfixturesandfasteningssuchasrollerbearingin nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thickplainglassandaluminiummosquitonetshutterwithstainlesssteeljailwith all required screws and nuts etc, complete. With colour Anodising without box. |
| 29 | Providingand fixing 50 mm x 50 mm Mild Steel square pipe framed steel windows of varioussizesasperdetailswithweldedsquarebars12mmat10cmcentertocenter without hot dip zinccoatingwithout/withventilatorincludingfabrication,glazing withplain/obscured glass panes 5 mm thickof approved type and quality, all fixtures and fastenings and finishing with one coat of primer complete. |
| 30 | Turbo Ventilator 24\": Providing wind operated tubo ventilator system of various sizes over the existing roof inclusing cutting CGI sheets, proper fixing in position to true line and level with all fixtures and fastenings incuding etc. complete. |
| 31 | Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shadepaintcomplete, onM.S.angle ofsize 35x 35x 3mm framewith properly cross braced M.S. angles of size35mmx35mmx3mm duly painted includingTwo M.S.angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and whitebandsof25cmwidthincludingallfixturesetc.andfixingtheboardsin1:4:8 concreteblockofsize60cmx60cmx75cmincluding,excavation,refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge. |
| 32 | Supplying and erecting mains with 3 x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit / trunking / inside pole / Bus bars or any other places as per specification No: WG-MA/BW. |
| 33 | Supplying and erecting LED Panel Light (600mm X 600mm) Max. 30 having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 34 | Point wiring in for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW. |
| 35 | Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg) as per specification no. OH- PL/STP. |
| 36 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP. |
| 37 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP. |
| 38 | Supplying, erecting & marking DP-MCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. |
| 39 | Supplying, erecting & marking DP-MCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR / MCB. |
| 40 | Supplying and erecting GI sheet 1.6 mm (16 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 41 | Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010. |
| 42 | Wiring for plug on board with Switch socket surface/concealed type, copperwiring and earthing and with modular accessories as per specification No: WG PW/CW. |
| 43 | Supplying and erecting regular/ standard model ceiling fan of 1400mm. Sweep complete erected in position as per specification no. FG-FN/CF |
| 44 | Supplying, erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc. in provided distribution board. |
| 45 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 25 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with staticxcitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, witherformance class G2 and maximum fuel consumption 5.0 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 65 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG. |
| 46 | Supplyinghardmurum/kankarattheroadsite,includingconveyingandstacking complete. |
| 47 | Spreading hard murum/ soft murrum/ gravel or kankar for side width complete. |
| 48 | Compactingthehardmurumsidewidthsincludinglayinginlayersoneachsidewith vibratory roller including artificial watering etc. complete. |
| 49 | Providing and laying in situ / ready mix M20 CC of trap/ granite/ quartzite/ gneiss metal for wearing course 8cm thick including compacting, finishing, curing and filling in joints withbitumenetc.complete.(withfullyautomaticmicroprocessorbasedPLCwith SCADA enabledconcretebatchmixplant /pan mixerwith fineagreegates ofrequired specifications ( VSI sand finely washed etc ) |
| 50 | Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shadepaintcomplete, onM.S.angle ofsize 35x 35x 3mm framewith properly cross braced M.S. angles of size35mmx35mmx3mm duly painted includingTwo M.S.angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and whitebandsof25cmwidthincludingallfixturesetc.andfixingtheboardsin1:4:8 concreteblockofsize60cmx60cmx75cmincluding,excavation,refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge. |
| 51 | BASIC TEST OF CEMENT:Standard Consistancy, Fineness, Specific Gravity, Setting Time ( Initial & Final ), Compressive Strength, Soundness. |
| 52 | BASIC TEST OF AGGREGATE:Water Absorption, Specific Gravity,Impact Value, Crushing Value. |
| 53 | BRICKS:Water Absorption (Set of 5 Bricks), Compressive Strength( Set of 5 Bricks), Efflorescence (Set of 5 Bricks). |
| 54 | CONCRETE:Compressive Strength OF C.C. Cube (Set of 3 cubes). |
| 55 | Sand: Sand Fineness Modulus, Silt Content |
| 56 | TMT Steel: Upto 16mm Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress. |
| 57 | Murum: Atterberg Limits; Liquid Limit & Plastic Limit Testing |
| 58 | Truss Steel Anti Corrosive Test: Resistance to applied Voltage. ( 1 Hr. Test ) (Set of 2 Bars) |
| 59 | Qty of Material utilised for Royelty For Sand |
| 60 | Qty of Material utilised for Royelty For Without Sand |
| 61 | Management Strategies and Implementation Plan (MSIP) to manage the Environmental, Social, Health and Safety (ESHS) risks and ESHS Code of Conduct |