Tender For Providing The Engineering Services For The Establishment Of In House Laundry At Homibhabha Cancer Hospital Sangrur Punjab.; 1 Dismantling brick work tile, masonry or tile 2 Cement concrete 1:8:16 With stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type 3 First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level. 4 12.5mm thick cement plaster 1:4. 5 20mm thick cement plaster 1:4 in two coat work. 6 Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete 7 Reinforced cement cocrete M-20 Mechnicaly batch mixed using batch type concrete mixer as per IS: 1791 and vibrator by needle vibrator but excluding steelreinforcement, centering and shuttering in super strucutre 8 Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts & nuts or screws or welding rod, complete fixed in position 9 Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge) The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25% -40%. should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting tosize and shape wherever required 10 Applying priming coat with metal primer onnew steel or iron work including preparation ofsurface. 11 Painting two or more coats excluding primingcoat with ready mixed paint for metallicsurfaces in all shades on steel or iron work 12 Taking out existing CC interlocking paver blocks from footpath/ central verge/pavement, including removal of rubbish etc., disposal of unserviceable material to the dumping ground,for which payment shall be made separately and stacking of serviceable material within 50metre lead as per direction of Engineer-in-Charge. 13 Re-laying of 60mm thick intrlocking paver blocks 14 Providing and laying 60 mm thick factory madecement concrete interlocking paver block of M-35grade machine made rubber moulded smoothfinish with strong vibratory process or with vibrohydrauliccompaction machine and of approvedsize and design / shape laid in Ordinary Grey andpattern over and including 40 mm thickcompacted bed of coarse sand, filling the jointswith fine sand etc, all complete as per directionsof Engineer-in-Charge for Non traffic Areas andstreets having width less than 3.05 mt.( Also notto used over footoaths). 15 CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings i/c fixingthe pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, withone step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.SDR 11 CPVC pipes & fittings 20mm o/d 16 CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings i/c fixingthe pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, withone step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.CPVC SDR 11 Pipe & fitting 25mmo/d 17 Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of anyother reputed firm including cutting, jointing, wastage, but excluding cost of jointing110mm o/d single socket SWR UPVC pipelines laid complete 18 Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of anyother reputed firm including cutting, jointing, wastage, but excluding cost of jointing 90mm o/d single socket SWR UPVC pipelines laid complete 19 Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.For 110mm o/d pipesP Trap/Floor Trap 110mm x 75mm 20 Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position Commercial with elm or gurjanfacing on both Sides with laminated core and lipped edges:- 35 mm thick 21 Conglomerate floor 40mm thick cement concrete1:2:4 on 100mm thick cement concrete 1:8:16and 100mm sand filling. using mechanical mixerfor mixing of material 22 Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -incharge) with cover with suitable locking arrangement and making necessary holes forinlet, outlet and over flo pipes but without fittingsand base support for tank.Triple Layer Tanks 23 Excavation in Soil (any type) using HydraulicExcavatorCK90 withhydraulicexcavatorof0.9 cumbucket capacity including cutting, trimming bottom and side slopes, in accordance wit requirementsof lines,gradesandcrosssections, including all lifts and combined lead upto 30m 24 Scraping White wash and colour wash 25 Preparation of plastered or concrete surfacefor painting (including sand papering thesurface) using ready mixed cement based wallputty by applying two or more coats to getrequired finish 26 Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade 27 Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surfaceto required finish complete. 28 Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concretesurface to give an even shade. 29 Cost of aluminum fittings complete for doors, windows such as tower boltshandles,Stoppersandscrewetc. for these fittings (Excluding sliding bolt) 30 Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC10 as per IS :1868) transparent or dyed to required colouror shade with nuts and screws etc. complete : 300x 16mm 31 Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement:4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shadecomplete 32 Providing and fixing glazing in aluminumdoor, window, ventilator shutters andpartitions etc. with PVC Plug/ neoprenegasket etc. complete as per thearchitectural drawings and the directionsof engineer-in-charge . (Cost of aluminumsnap beading shall be paid in basic item)Float glass panes of 5 mm thickness 33 Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming toIS : 15622 of approved make in all colours andshades, laid on 20mm thick cement mortar 1:4 (1cement: 4 fine sand), complete. ( Design ishomogenous throughout the tile body ).Size 600 x 600mm 34 ETP Plant Compelete AS Per Specifications Attached Of 2.5 KLD and Pressure Pump For Water Supply Complete 35 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel/medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C (Primary Point upto 12.5 Mtrs.) 36 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel/PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required.Group C (Secondary Point upto 10.5 Mtrs.) 37 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 38 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 39 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 40 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 41 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 42 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable of DELTON/POLYCAB/RR KABLE/FINOLEX in the existing surface/ recessed steel/ PVC conduit as required. 4 pair UTP CAT 6- 1 run of Cable 43 SITC of RJ 45 I/O jack with cover plate of required size including PVC/GI base Box. Complete in all aspect Schneider/MOLEX/Belden make 44 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 45 Supply & erection of PVC Casing n Capping (Double Lock) ISI marked for wiring purposes including cost of bends (L), (U), (T) & inspection boxes etc., where necessary including other petty material:- PVC Casing n Capping Size 25mm x 16mm 46 Supply and erection of PVC Channel (uPVC Trunking) with cover of various sizes (On Surface) on wall, Flat angle, internal & external angle, Flat Tee, End cap and mounting boxes including the cost of joint cover, fixing and other petty material etc.:- PVC Channel (uPVC Trunking) 50mm x 50mm 47 Supplying the following modular switch/ socket excluding modular plate etc. as required. 48 5/6 amps switch 49 2 way 5/6 amps switch 50 15/16 amp switch 51 3 pin 5/6 amp socket outlet 52 6 pin 15/16 amp socket outlet 53 Bell push 54 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 55 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 56 Supplying the following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess etc as required. 57 3 Module 58 8 Module 59 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 60 6 A to 32 A ratings , SP MCB “C” curve, 10 KA breaking capacity 61 6 A to 32 A ratings , DP MCB, “C” curve, 10 KA breaking capacity 62 Supply and erection of Miniature Circuit Breaker MCBs for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- 63 MCB Triple Pole 50, 63amp. (10kA, Curve-C) 64 MCB Triple Pole 40amp. (10kA, Curve-C) 65 Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cableties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBOs/ RCCBs in the distribution board (For SP&N distribution board with provision DP MCBs/ RCCBs/ RCBOs as incomer and SP MCBs as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCBs/ RCCBs/ RCBOs as incomer and SP MCBs as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- 66 SP&N Double Door Distribution Board 4 way each 67 TP&N Double Door Vertical DBs 8 way each (With provision of FP MCCB 160amp.) 68 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-- 69 Overall size 95sq.mm (3½ Core) Armoured 70 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 71 3½ X 95 sq. mm 72 Flexible Cables:- Supplying, fixing of following flexibles copper conductor 1100 V a.c. grade cables Polycab/RRK/Finolex make with proper connection at both the ends as directed by Eng --in -chrg. 73 1 x 10 sq.mm 74 LED Street light fixture, powder coated pressure die cast aluminum body (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80 , under voltage and over voltage protection,EMIEMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 75 High performance IP66 LED streetlight, 40W LED 76 LED Light BATTENft Tube 20watt 77 Supply of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 78 Supply of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required of following size: 79 300 mm 80 15 380mm Industrial Heavy Duty Exhaust Fan 81 Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- 82 MCCB Four Pole 160amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 83 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II completewith fitting and cutting, jointing etc. in the existing trench, complete as required. 84 90 mm dia (OD-90 mm & ID-76 mm nominal) 85 Supplying and fixing TP sheet steel enclosure on surface/ recess along with Conduite if required of the following rating 415 volts “C” curve TPN MCB complete with connections, testing, and commissioning etc. as required. Make: L&T/Schneider/ABB/Legrand 86 Tripl pole and neutral 32A (Equipment side) 87 Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- 88 Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. 89 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- 90 Overall size 16sq.mm (3.5Core) Un-armoured 91 Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- 92 Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) 93 Additional Length 20mm x 3mm thick Copper Tape