| 1 | Taking down carefully copper/ aluminum point wiring (light, fan socket or power) complete incl. (fitting such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc.), removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc, complete all as specified and directed. |
| 2 | M&L for point wiring 1.5 Sqmm (nominal cross sectional area) with colour coding multistranded copper conductor cable, PVC insulated (FRLS-H) and unsheathed cable and including drawn through PVC conduit 20mm concealed wiring with all fittings and accessories, terminated to sunken box and laminated sheet of suitable size for housing/mounting the switches/sockets including 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable earth wire connected to common earth dolly for one light/fanpoint control by one, one way switch complete all as specified and as directed. |
| 3 | All as per Srl item No 2.00above but for one bell/ buzzer point controlled by one push button, complete all as specified and as directed. |
| 4 | All as per Srl item No 2.00above but two way swithces complete all as specified and as directed. |
| 5 | All as per Srl item No 2.00above but one 3 pin socket oulet 5 amps, onsame board with other switches, complete all as specified and as directed. |
| 6 | All as per Srl item No 2.00above but one 3 pin socket oulet 5 amps, onindependent board, complete all as specified and as directed. |
| 7 | All as per Srl item No 2.00above but for one 3 pin 15 Amps, power point on independent board with 2.5 Sqmm complete all as specified and directed. |
| 8 | M&L for point wiring with multistranded copper conductor cable,PVC insulated and unsheathed (FRLS-H)size 1.5 sqmm drawn in and inclPVC casing and caping with fixing accessories for one light /fan point controlled by one switch mounting on PVC box ofsuitable size incl continous earth wire of PVC insulated unsheathed multi stranded copper conductor cablesize 1.5 Sqmm for earth wire connected to common earth dolly incl making good disturbed surface as per existing complete all as specified and directed.Note: Cost of making good disturbed surface as per existing deemed to be included in quoted rates. |
| 9 | All as per Srl item No 8.00above but for oneone bell/ buzzer point controlled by one push switch on independent board, complete all as specified and as directed. |
| 10 | All as per Srl item No 8.00above but two way swithces, complete all as specified and as directed. |
| 11 | All as per Srl item No 8.00above but one 3 pin socket oulet 5 amps, onsame board with other switches, complete all as specified and as directed. |
| 12 | All as per Srl item No 8.00above but one 3 pin socket oulet 5 amps, onindependent board, complete all as specified and as directed. |
| 13 | All as per Srl item No 8.00 above but for one 3 pin 15 Amps power point on independent board with 2.5 Sqmm complete all as specified and directed |
| 14 | M&L for point wiringin existing concealed conduit/ casing caping multistranded copper conductor cable,PVC insulated and unsheathed (FRLS-H)size 1.5 sqmm drawn in and all fixing accessories for one light /fan point controlled by one switchwith pressed steel concealed terminal boxes coveredwith 3 mm thick laminated sheet/ PVC Box incl continous earth wire of PVC insulated unsheathed multi stranded copper conductor cablesize 1.5 Sqmm for earth wire connected to common earth dolly incl making good disturbed surface as per existing concealed conduit/ casing caping, complete all as specified and directed. |
| 15 | All as per Srl item No 14.00above but for one bell/ buzzer point controlled by one push button, on independent board, complete all as specified and as directed. |
| 16 | All as per Srl item No 14.00above but two way swithces, complete all as specified and as directed. |
| 17 | All as per Srl item No 14.00above but one 3 pin socket oulet 5 amps, onsame board with other switches, complete all as specified and as directed. |
| 18 | All as per Srl item No 14.00above but one 3 pin socket oulet 5 amps, onindependent board, complete all as specified and as directed. |
| 19 | All as per Srl item No 14.00above but for one 3 pin 15 Amps power point on independent board with 2.5 Sqmm complete all as specified and directed |
| 20 | S&F switch piano flush type single pole, one way 5 Amp (ISI marked), complete all as specified and directed. |
| 21 | S&F Bell push, flush type, 5 amp (ISI marked), complete all as specified and directed. |
| 22 | S&F switch piano flush type single pole, two way 5 Amp (ISI marked)complete all as specified and directed. |
| 23 | S&F switch piano flush type single pole, one way 15 Amp (ISI marked)complete all as specified and directed. |
| 24 | S&F socket (ISI Marked) 2 in 1, 3 pin 5/6 amps flush type complete all as specified and directed. |
| 25 | S&F socket 2 in 1, 5 pin, 5 and 15 amps (ISI marked) flush type universal complete all as specified and directed. |
| 26 | S&F in repair Modular switch 1 way 6 A, module complete all as specified and as directed. |
| 27 | S&F in repair Modular switch 1 way 16 A, module complete all as specified and directed. |
| 28 | S&F in repair Modular Bell push 6 A, 1 Module complete all as specified and directed. |
| 29 | S&F in repair modular Socket, 6A-2/3 pin combined 2 module complete all as specified and directed. |
| 30 | S&F in repair modular Socket, 6A/16A-2/3 pin combined 2 module complete all as specified and directed. |
| 31 | S&F in repair white cover plate with frame 1 Module complete all as specified and directed. |
| 32 | S&F in repair white cover plate with frame 2 Module complete all as specified and directed. |
| 33 | S&F in repair white cover plate with frame 3 Module complete all as specified and directed. |
| 34 | S&F in repair white cover plate with frame 4 Module complete all as specified and directed. |
| 35 | S&F in repair white cover plate with frame 6 Module complete all as specified and directed. |
| 36 | S&F in repair white cover plate with frame 8 Module complete all as specified and directed. |
| 37 | S&F for Metal flush box 1 module complete all as specified and directed. |
| 38 | S&F for Metal flush box 2 module complete all as specified and directed. |
| 39 | S&F for Metal flush box 3 module complete all as specified and directed. |
| 40 | S&F for Metal flush box 4 module complete all as specified and directed. |
| 41 | S&F for Metal flush box6/8 module complete all as specified and directed. |
| 42 | S&F in repair PVC conduit of 20mm dia complete all as specified and directed. |
| 43 | S&F in repair PVC conduit of 25mm dia complete all as specified and directed. |
| 44 | S&F in repair PVC casing capping of 25mm (1\")width complete all as specified & directed |
| 45 | S&F ceiling rose, 3 phase, PVC polycarbonate, insulated body (ISI Marked) complete all as specified and directed. |
| 46 | S&F in repair Bell, Buzzer type, AC 230 volts single pole complete all as specified and directed. |
| 47 | M&L for lamp holder (Angle) PVC/Polycarbonate type with back plate suitable for batten/ bulb fittings incl 12 watt LED Bulb, complete all as specified and directed. |
| 48 | S&F 12 watt LED Lamp, complete all as specified and directed. |
| 49 | S&F LED inverter battern with fixture, 1x 20 watt, (4 Feet) wall mounted, with PC housing and diffuser, IP20 complete including electrical connection with copper cable from ceiling rose to fittings and including taking down existing fittings complete all as specified and directed.Make: HPL Cat part No: HPLLEDINVT5BPC20CW/ Havells/ Bajaj or in equivalent as approved |
| 50 | S&F LED inverter battern with fixture, 1x 10 watt, (2 Feet) wall mounted, with PC housing and diffuser, IP20 complete including electrical connection with copper cable from ceiling rose to fittings and including taking down existing fittings complete all as specified and directedMake: HPL Cat part No: HPLLEDINVT5BPC10CW/ Havells/ Bajaj or in equivalent as approved |
| 51 | S&F LED battern with fixture, 1x 20 watt, (4 Feet) wall mounted, with PC housing and diffuser, IP20 complete including electrical connection with copper cable from ceiling rose to fittings and including taking down existing fittings complete all as specified and directed.Make: HPL Cat part No: HPLLEDINVT5BPC20CW/ Havells/ Bajaj or in equivalent as approved |
| 52 | S&F LED battern with fixture, 1x 10 watt, (2 Feet) wall mounted, with PC housing and diffuser, IP20 complete including electrical connection with copper cable from ceiling rose to fittings and including taking down existing fittings complete all as specified and directed. Make: HPL Cat part No: HPLLEDINVT5BPC10CW/ Havells/ Bajaj or in equivalent as approved |
| 53 | S&F in replacement 36/40W LED (Size 2\"x2\") square shapedRecess mounting type luminaire having white polycarbonate body & Alumium heat shink with PMMA diffuser, 5700K, IP54including connecting three core copper cable up to ceiling rose complete all as specified and directed. Make: HPL Cat part No: HPLLEDCR040CW/ Havells/ Bajaj or in equivalent as approved. |
| 54 | S&F in replacement round type POLLARD LED luminaire 12 Watt including two way DB with MCB and fixing arrangement, PCC 1:3:6, suitable upto 20x20cm as per the size of fittings and connecting twin core cable up to nearest point complete all as specifed and directed. Make: HPL Cat part No: HPLLEDB9W/ Havells/ Bajaj or in equivalent as approved. |
| 55 | S&F in replacement round type POST TOP LANTERN mounting LED luminaire 20 Watt including making arrangment in pole/wall as per the size of fittings and connecting twin core cable up to nearest point complete all as specifed and directed by Engr-in-Charge. Make: HPL Cat part No: HPLLEDPCR20W/ Havells/ Bajaj or in equivalent as approved. |
| 56 | S&F LED Bulkhead luminaire 20WDecorative type as per sample complete including electrical connection and including taking down existing fittings complete all as specified and directed.Make: HPL Cat part No: HLPLEDBH20W (CW)/ Havells/ Bajaj or in equivalent as approved. |
| 57 | S&F LED building securtiy light 36 watt fixed on wall suitable bracket with all connected accessories complete including electrical connection with copper cable from ceiling rose to fittings and including taking down existing fittings and all fixing arrangements complete all as specified and directed.Make: HPL Cat part No: HPLLEDSL3660AEWS/ Havells/ Bajaj or in equivalent as approved. |
| 58 | M&L for submain wiring with 2x6.0Sqmm+1x6.0Sqmm Earth Wire single core PVC insulated FRLS-H PVC sheathed cooper cableconnecting to common earth dolly in and including heavy duty PVC concealed conduit/ PVC Casing-N-Caping as per site requirement and direction by EIC, with all accessories complete including taking down to old unserviceable complete all as specified and directed. Note: Three runs of copper wire for phase, neutral, earth & one run PVC conduit/ casing shall be measured one unit length. |
| 59 | All as per Srl item No 58.00 above but for 2 run of single core 4 Sqmm FRLS-H, PVC insulated unsheathed multistranded copper conductor cable and one run of 4.0 Sqmm FRLS-H, PVC insulated unsheathed multistrandedcopper conductor earth wire complete all as specified and directed. |
| 60 | S&F VTPN prewired distribution board TPN-DPX 125 MCCB , IP 54 including one No MCCB 125 Amps as incomer and suitable SPN/ TP MCBs as outgoing double door type sheet metal enclosure 415V with 200 Amps rated standard busbar of suitable size plate and common neutral link without MCBs with blank plate suitable for 4 way complete and including taking down complete all as specified and directed. Note :- MCB/ SP/ TP shall be measured in respective items. Make: L&T/ Legrand/ Schneider. |
| 61 | S&F sheet metal enclosure MCB DB 4 way, TPN double door suitable for 415 V, IP 54 fixed flushed on walls, including cutting Knitch and making good disturbed surfaces complete all as specified and directed.Make: L&T/ Legrand / Schneider. |
| 62 | S&F sheet metal enclosure MCB DB, 12 way, SPN double door suitable for 240 V, IP 54 fixed flused on walls including cutting Knitch and making good disturbed surfaces complete all as specified and directed.Make : L&T / Legrand / Schneider. |
| 63 | S&F sheet metal enclosure MCB DB 8 way, SPN double door suitable for 240 V, IP 54 fixed flused on walls including cutting Knitch and making good disturbed surfaces complete all as specified and directed. Make : L&T / Legrand / Schneider. |
| 64 | S&F sheet metal enclosuresDB\"s 4 waySPNdoubledoor suitable for 240 V, IP 54complete all as specified and directed. Make : L&T / Legrand / Schneider |
| 65 | S&F sheet metal enclosuresDB\"s 2 way, SPNsingledoor suitable for 240 V, IP 54complete all as specified and directed. Make : L&T / Legrand / Schneider |
| 66 | S&F MCB SP (single pole) 06 to 32 Amps \"B\" Curve with 10 kA for inductive load connected through cable lugs of suitable size complete all as specified and directed. Make : L&T / Legrand / Schneider |
| 67 | S&F MCB SPN/DP (single pole and neutral) 32/40 Amps \"B\" Curve with 10 kA for inductive load connected through cable lugs of suitable size, complete all as specified and directed. Make:L&T/ Legrand/ Schneider |
| 68 | S&F MCB SPN/DP (single pole & neutral) 240 volt 63 amp \"B\" Curve with 10 kA for inductive loadconnected through cable lugs of suitable size, complete all as specified and directed. Make:L&T/ Legrand / Schneider |
| 69 | S&F MCB TP 415 volt 25 to 63 amp \"B\" Curve with 10 kA for inductive loadconnected through cable lugs of suitable size complete all as specified and directed. |
| 70 | S&F MCB TPN/ FP 415 volts 40 to 100 amp \"B\" Curve with 10 kA for inductive loadconnected through cable lugs of suitable size complete all as specified and directed. |
| 71 | S&F MCCB 4 Pole 415 V fixed type 25 to 100 Amps with breaking capacity 16 KAfor inductive loadconnected through cable lugs of suitable size complete all as specified and directed. |
| 72 | S&F MCCB 4 Pole 415 V fixed type 125 to 160 Amps with breaking capacity 16 KAfor inductive loadconnected through cable lugs of suitable size complete all as specified and directed. |
| 73 | S&F Single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB with 240 volt, 20 amps, including taking out complete all as specified and directed. Note: MCB, MCCB, DB Should be of same make for Item Nos 60 to 73. |
| 74 | S&F in repair MS conduit medium grade 20 mm diafor passing electric wires/ fixing of tube light suspension type including necessary swivel joints and connecting up complete all as specified and directed. |
| 75 | S&F in repair surge protection device (SPD)/ ELCB Voltage protection level up upto 1.3 kV, suitable for protection of all terminal equipments both common & differential mode protection, complete all as specified and directed. |
| 76 | S&F 15/ 20 Amp Socket with 16/ 20 Amp MCB with metal box combination (ISI marked) flush type universal, complete all as specified and directed. |
| 77 | S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm including fixing all arangements complete all as specified and directed.Note:Old unservicable material obtained shall be deposited to AGE E/M store yard by the contractor. |
| 78 | S&F in repair exhaust fans AC single phase 230/ 240 V of size 300 mm sweep metal body with louver including fixing all arangements complete all as specified and directed. Note:Old unservicable material obtained shall be deposited to AGE E/M store yard by the contractor. |
| 79 | S&F in repair exhaust fans AC single phase 230/ 240 V of size 450 mm sweep metal body with louver including fixing all arangements complete all as specified and directed. Note:Old unservicable material obtained shall be deposited to AGE E/M store yard by the contractor. |
| 80 | S&F in repair AC single phase static energy meter of accuracy class 1.0, 240 V, 50 Hz back light LCD display of rating 5 - 30 A, (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type box made up of GI sheet thickness 3.15mm / sheet metal enclosure,including fixing all arangements complete all as specified and directed. |
| 81 | S&F in repair electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 Litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc and fixing arrangements complete all as specified and directed. Note : Old Item Nos 77.00 to 81.00 all to be deposited in AGE E/M store yard by contractor. |
| 82 | S&F Galvanized zinc metallic zinc coated Iron earthing electrode speciallized developed for high sensitive equipment/ panel/ bldg. Model SN001 (LXXVI MM ) as per Cpri 300 Cm long. Tested on 52.kA, C % 12 max, mn 0.60%mm class type GALV. Yield strength 329, tensile Strength 426, elongation bend/ flattering. Thickness Internal disposes \"2 inch x6mm with base plate 3.15 to close the earthing rod. Terminal 2 inchx 6mm filled with highly conductive compound which increase the life of earthing electrode. Composition of chemical filled in electrode water solubility. Grain size 100 mesh, along with SN make BFC compound non toxic, non reactive, non explosive and non corrosive, longerlife easy to maintain less space consistent results. Earthing pit and chamber cover, complete all as specified as directed.Make: SN Engineering/ Protrat/ Enjes Co. |
| 83 | S&F burnished metallic brown 99.69%, non galvanized non electrolyte earthing electrode with exothermic welding/ breezing welding at top of earthing electrode. Earthing equivalent SN model SN001 (LXXVI mm) dia 300 CMLONG with chemical filled in electrode chemical analysis highly, thickness internal dispose, 2inch x6mm with base plate 3.15 to close the earthing rod. Terminal 2inch x6mm filled with highly conductive compound which increase the life of earhing electrode. Composition of chemical filled in electrode water solubility, acidsolubility Grainsize 100mesh, alongwith SN makes BFC compound non toxic, non reactive, non explosive and non corrosive, longer life easy to maintain less space consistent results, with earth pit chamber cover, complete all as specified as directed. Make: SN Engineering/ Protrat/ Enjes Co. |
| 84 | S&F framed work such as grills, gratings, etc with end bars shouldered and/ or riveted, or forged into spikes, frames guard bars, barred iron doors ladders framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290, Gde E-165, (for exhaust fan louver), complete all as specified and directed. |
| 85 | M&L for expanded metal cut to length bent to shape required and typing with and incl anneled mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples complete to wood or steel members incl painting complete all as specified and directed. |
| 86 | S&F air termination, single pointed aluminium rod 12mm dia and 300mm long, complete all as specified and directed. |
| 87 | S&F test point terminal block made of GI sheet 75x75x25mm drilled and screwed incl complete all as specifeid and directed. |
| 88 | S&F aluminium strip 25x3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed. |
| 89 | S&F galvanised iron strip 32x6mm buried in ground with saddles and fixing screws etc. buried in ground, complete all as specified and directed. |
| 90 | S&F porceline insulator for fixing of strip with screws for both end hole etc. buried in roof/ wall/ ground etc., complete all as specified and directed. |
| 91 | Supply, fixing and laying GI tubing light grade 40mm dia used as protection pipe for earth lead strip in earthing or alongwith pole/ wall/ culvert/ drainage etc. for mechanical protection of cable complete all as specified and directed.Note: All required items and acessories, bend, joints, nut and bolts, clamps etc. are incl in quoted rate. |
| 92 | S&F in repair LED 7 wattlamp suitable for existing type thread/ pin including taking out old unserviceable complete all as specified and directed. |
| 93 | S&F in repair LED 9 wattlamp suitable for existing type including taking out old unserviceable complete all as specified and directed. |
| 94 | S&F in repair LED 5 wattlamp suitable for existing type including taking out old unserviceable complete all as specified and directed. |
| 95 | S&F in repair Single core PVC Insulator with Copper stranded Conductor Cable 1100V grade ISIsize 1.5 Sqmm complete all as specified and directed. |
| 96 | S&F in repair Single core PVC Insulator with Copper stranded Conductor Cable 1100V grade ISIsize 2.5 Sqmm complete all as specified and directed. |
| 97 | S&F in repair Single core PVC Insulator with Copper Conductor Cable 1100V grade ISIsize 4.0 Sqmm complete all as specified and directed. |
| 98 | S&F in repair Single core PVC Insulator with Copper Conductor Cable 1100V grade ISIsize 6.0 Sqmm complete all as specified and directed. |
| 99 | S&F in repair service cable 6.0 sqmm x 2 core PVC Insulator with Aluminium Conductor Cable 230V grade ISI complete all as specified and directed. |
| 100 | S&F in repair service cable 10.0 sqmm x 2 core PVC Insulator with Aluminium Conductor Cable 230V grade ISI complete all as specified and directed. |