Tender For Provision Of Open Shed For Parade Cum Enrolling Shed At Aro Complex At Fort Area Kamptee, And Provision Of Mt Shed (45M X 10M) At Fort Area Nagpur Under Ge Kamptee.; 1 Surface dressing n.exc 15 cm deep in soft /loose soil including clearing away all grass vegetation, saplings, shrubs, brushwood, undergrown roots, and trees not exceeding 30 cm girth complete all as specified and as directed. 2 Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, soft/loose soil complete all as specified and as directed. 3 Excavation in trenches n exc 1.5m in deepth and 1.5m in widthand getting out in soft/loose soil complete all as specified and directed. 4 Excavation in trenches n exc 1.5m in deepth and 1.5m in widthand getting out in hard/dense soil complete all as specified and directed. 5 M&L for Excavating over areas, n exc 1.5 m deep and getting out soft/loose soil complete all as specified and as directed. 6 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm with soft/ loose soil complete all as specified and as directed. 7 Removing excavated material n exc. 50m and depositing where directed at a level n. exc 1.50m from staring level complete all as specified and as directed. 8 M&L for Sand filling under floorings/pavement spread and levelled in layers n.exc 15cm thick complete including watering and consolidation complete all as specified and as directed. 9 M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed. 10 M&L for hardcore of gauge not exceeding 63mm (Broken stone or boulders) ,deposited, spred and levelled in layer not exceeding 15cm thick, watered and rammed to true surface complete all as specified and as directed. 11 M&L for Plain cement concrete in foundation filling type B-2 1:2:4 (40mm graded aggregate) and mass concrete complete all as specified and as directed. 12 M&L for Plain Cement concrete Type D2 1:4:8 (40mm graded aggregate) as in sub bases/pavings complete all as specified and directed. 13 M&L for providing 100 mm thick PCC 1:2:4 Type B-2 (using 20 mm graded stone aggregate) as in flooring including finishing the cement concrete surface even and smooth with using extra cement complete all as specified and directed. 14 M&L for PCC 1:3:6 type C1 using 20mm graded stone aggregate as in coping including weathering, throating and necessary formwork complete all as specified and directed. 15 M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming toI.S.1161-1979 grade St.-240 etc conforming to IS 1161-1979 grade Fe 410-W (Gde- E- 250) quality complete all as specified and directed 16 M&L for Steel work in Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting platesconforming to I.S. 1161-1979 grade St.-240 etc conforming to IS 1161-1979 grade Fe 410-W (Gde- E- 250) quality complete all as specified and directed. 17 M&L for Machine pressed precast conctete interlocking paver block colour glessyfinishedrubber pressed any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade ® with Grey cement and pigment complete all as specified and as directed. 18 M&L for Machine pressed precast conctete interlocking paver block colour glessyfinishedrubber pressed any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade ® with Grey cement and pigment complete all as specified and as directed. 19 S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment grade Fe 410-W (Gde-E-250) A quality completeall as specified and directed. 20 S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. 21 S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. 22 M&L for preparation of new steel surfaces of any description over 10 cm width or girth & applying two coats synthetic enamel paint complete all as specified and as directed. 23 S&F Mild steel sheet eaves gutters 1.25mm thick 150mm dia, galvanised class 3, half round with rounded edges etc complete all as specified and as directed. 24 S&F in repairs PVC (SWR) 110 mm bore of pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed. 25 M&L for brick with fly ash brick old size straight of curved on plan exc. 6m mean radius built in CM 1:6 complete all as specified and as directed. 26 M&L for Rendering 15mm thickin cement mortar 1:6, finished even and smoothwithout using extra cement complete all as specified and as directed. 27 M&L for preparation newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed. 28 M&L for point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts.grade FRLSH PVC insulated unsheathed cable with proper colour codingdrawn in including PVC concealed conduit not less than 20 mm dia with all accessoriesandFRLSH PVC insulated 1.5 Sqmm multi standard sheathed copper wire for continues earth,incl PVC conduit with necessary clamps andmodular sunken box, modular cover plate and connecting earth Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles for One light /fan point controlled by one switch complete all as specified and directed.Note:- Cost of 2.5 sqmm FRLSH wire provided from sub main DB to respective switch board in rooms shall deemed to be include in the quoted point wiring rate. 29 All as per item No 28 here-in-before but One 3 pin 6 amp socket out point on the same board with other switches complete all as specified and directed. 30 All as per item No 28 here-in-before but One 3 pin 6 amp socket out point on the Independent board with 2.5 sqmm wire complete all as specified and directed. 31 All as per item No 28 here-in-before but with cable size 4 Sq mm for one 5 pin 16 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm all as specified and directed. 32 S&F modular switch piano single pole, one way 6 Amps 1 module, complete all as specified and directed. 33 S&F modular socket outlet2/3 pin 6 Amps combined 2 module, complete all as specified and directed. 34 S&F modular switch piano flush type 16 Amps single pole one way, one module, complete all as specified and directed. 35 S&F modular socketmultipurpose 3 pin 6/16 Amps combined 2 module, complete all as specified and directed. 36 S&F modular step type, 2 module electronic fan regulator heavy duty 120watts 240 volts, complete all as specified and directed. 37 S&F ceiling rose PVC Polycarbonate isolated body 62.5 x 25 mm, three terminals, complete all as specified & directed. 38 S&F modular cover plate with metal frame (inner and outer) 3 module for mounting switch and sockets complete all as specified and directed. 39 S&F modular cover plate with metal frame (inner and outer) 8 module for mounting switch and sockets complete all as specified and directed. 40 S&F LED tube light fitting 20 watt, 4 feet (cool/warm white), surface / wall mounted with polycarbonate housing, high optically efficient polycarbonate diffuser, CRI ≥ 80, PF ≥ 0.95, lumen output≥ 2000 Lm, Colour temp 3000/6500K, luminous efficiency > 100 Lm/watt, electrical insulation class 1, operating voltage 140-270,THD <20%,Surge protection 2.5 KV, 50000 burning hrs (min), complete all as specified and directed. 41 S&F LED security lightwith aluminium pressure diecast housing, IP 65 protection, luminaire lumens > 3000 lm, power consumption < 25W and luminous efficiency > 100 lm /W, electrical insulation class 1, CRI > 80, temp range 0 to 50º C and in built electronic driver prewire upto terminal block with driver efficiency > 85%, power factor > 0.95,colour temp 6500 K Surge protection 3.5 KV, 50000 burning hrs (min) as per L70 criteria, multi stage constant current operated driver with operating voltage range 150-270V AC, fixed to pole or wall of building incuding connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 sqmm including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. 42 S&F new generation, energy saving and environmental friendly long life LED Floodlight fitting of wattage 100 watt, CRI ≥ 70, PF ≥ 0.90, lumen output≥ 9000 Lm, Colour temp 5700K, luminous efficiency > 900 Lm/watt, electrical insulation class 1, operating voltage 140-270,THD <20%,Surge protection 2.5 KV, 50000 burning hrs (min), complete all as specified and directed 43 M&L for sub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 20 mm medium grade concealed inwall of the size 2x1.5 Sqmm with earth wire of 1x1.5 Sqmm complete all as specified and directed. 44 S&F ceiling fan, 1400mm sweep, minimum BLDC (Brush Less Direct Current Energy saving ceiling fan, 230 Volts, 50 Hz power consumption is less than 35 watt, 5 star rated noiseless motor operation, inverter stabilization technology, 300 RPM, Air delivery 245 cum/min complete with standard accessories i.e (three blade, 02 Nos canopy, down rod of length 1.5 mtr to 2.0 mtr long, 02 Nos hanging clamps with rubber real insulator, nuts, lock nuts,bolts, washers, split locking pins etc), double ball bearing, copper wound, including electrically connecting from ceiling rose to fan connector with 0.75 sqmm flexible copper conductor three core with suitable size flexible PVC conduit complete all as specified and directed. 45 S&F of sheet metal enclosure Vertical TPN DB 4 Way double door As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 250 A Copper Busbar for each phase with 2 Neutral bar, 2 earthbar and Cable ties for Cable manage-ment, fully insulated busbar & shrouded Neutral bars, Improved Pan assembly for easy of installation, Prefitted masking sheet, Reversible Door for IP 54 DBs,space for 125 Amp MCCB as incomer complete all as specified and directed. 46 S&F MCCB 125 Amps with sheet metal enclosure, MCCB ,4 Pole, 50Hz ,Icu= 36 KA at 415 volts, with thermal magnetic release & Ics=100% Icu with adjustable over load setting (minimum 80% to 100%)complete all as specified and directed. 47 S&F MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rat-ed bus bar of suitable size plate and common neutral link all en-closed in standard steel sheet flush mounting type factory fab-ricated, powder coated complete with out MCBand with enclo-sure blank plates for unused way suitable for 12 way ISI marked all as specified and directed. 48 S&F miniature circuit breaker (MCB) single pole of capacity 63 Amps rating 240V, 10KA C curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. 49 Supply and fixing MCB SP 6 to 32 Amp rating 240V, 10KA C curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. 50 Supply and fixing MCB SPN 63 Amp rating 240V, 10KA C curve and current carrying ca-pacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. 51 Supply and fixing MCCB 160 with sheet metal enclosure, 4 Pole, 50 Hz, lcu= 25 kA at 415 volts with thermal magnetic release & lcs= 100% lcu with adjustable overload setting (minimum 80% to 100%) complete all as specified and directed. 52 Supply and fix Double wall corrugated High Density Polymer Ethyl(HDPE) pipe for laying of electric cable of size 50 mm outer diameter and 38 mm inner diameter with IS 14930 (part 2) 2001 and 6mm thickness laid in trenches(Including cutting of roads or any others hard surfaces and making good disturbed surfaces) , wall, poles including jointer and other connected accessories complete all as specified and directed. 53 Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened,PVC bedded, galvanised steel strip or wire armoured,electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sq mm,4 core including testing after laid and jointed complete all as specified and directed. 54 M&L for Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burrieddirectly in groundverticallyto a depth not less than 2.5 metrebelowgroundlevelwith topedgeof theearth plate at a depth not less than 1.5 mtr belowgroundlevelearth platesurrounded from all sides by 15cmthickpacked layer ofcharcoal dust and common saltfillinginalternate layers andelectrodeconnectionby usingGI wire 4mm by meansof bolts, nuts, check nutsand washersmade of galvanised ironand thimbles and other endof theearth wire connectedto mainswitch boardprotected by galvanised iron medium grade pipe 40mm borein wall/floor/andGI Pipe 20 mm borelight grade forwatering with funnel and wiremesh PCC chamber in cementconcrete 1:3:6 typeC-2 and RCC pitcover includingnecessaryexcavation andearth work in anytype ofsoil, returningslurry approved soil and disposed of surplussoilto adistancenotexceeding 50 Mtraway all as shown inelectrical plateNo 3ofSSR 2009 ( Part-I).Notes :-(a)The unit rate shall include for GI protection pipe, GI watering pipe, wire mesh, funnel and excavation, RCC pit cover, test point, galvanised iron strip from top of earth plate upto 7.5 metres above ground level and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made.(b) PCCpit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate.(c) If the testing result of earthingwork is not found satisfactory then the contractor shall do another earthing work at his own cost and nothing shall be permissible on this account.