Tender For Remodeling Of Girls Hss Thanamandi- 1 Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) includingdisposal of excavated earthlead upto 50meters and lift upto 1.5 m,as directed by Engineer-in-Charge. All kinds of soil : 2 Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil : 3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, lead upto 50Mt & lift upto 1.50M. 4 Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete 5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 6 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 7 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 8 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) 9 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 10 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 11 CAST-IN-SITU Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 12 Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 13 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 14 Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with: 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 15 Steel Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more 16 Centering and shuttering including strutting, propping etc. and removal of form work for :- Foundations, footings, bases of columns etc. for mass concrete 17 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 18 Columns, Pillar, Pier, abutments, posts and struts 19 Lintel, beams, plinth beams, girders, bressumers and cantilevers 20 Suspended floors, roofs, landings, balconies and access platforms 21 Edges of slabs and breaks in floors and wallsUnder 20 cm wide 22 Stairs (excluding landings) except spiral staircases. 23 Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand) 24 Extra for brick work in super structure above plinth level upto floor V-level. 25 Half brick masonryHalf brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:3 ( 1 cement : 3 coarse sand) 26 Extra for half Brick masonry in superstructure above plinth level upto floor V level 27 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 28 CERAMIC GLAZED TILES Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 29 Frames and trusses Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Sal wood 30 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws- 35 MM THICK 31 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured) 32 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 33 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Float glass panes 5.0 mm thick glass pane (weighing not less than 12.50 kg/sqm) 34 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.Fixed to openings / wooden frames with rawl plugs screws etc. 35 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with10 mm diameter bolts, nuts and wooden plugs and embeddings in cementconcrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 gradedstone aggregate 20 mm nominal size). 36 Providing and fixing bright finished brass door latch with necessary screws etc. complete. : 300x16x5 mm 37 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete.250x10 mm 38 Providing and fixing bright finished brass handles with screws etc. complete :125 mm 39 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete Twin rubber stopper 40 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. 41 Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto1.75 sqm). 42 Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) 43 Cost for 6 mm thick clear heat strengthened glass 44 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete.Hot finished welded type tubes 45 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 46 Providing and fixing hand rail of approved size by welding etc. to steel Ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube 47 VITRIFIED FLOOR TILES Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching Pigments etc. complete. Size of tile 600x600 mm 48 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shades, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints. Size of tile 600x600 mm 49 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 50 Stone tile work for wall lining upto 10m height with special adhesive like araldite or equivalent over 12mm thick bed of cement mortar 1: 3 (1 cement : 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade. 8mm thick (mirror polished and machine cut edges) Granite stone of any colour and shade 51 Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work 52 CEMENT PLASTER (IN FINE SAND) 12mm Cement plaster of mix: 1:6 (1 cement : 6 fine sand) 53 15mm cement plaster on the rough side of single or half brick wall of mixin 1:6 (1 cement : 6 fine sand). 54 6MM CEMENT PLASTER 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) 55 Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture 56 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work 57 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 2 mm thick 58 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/liter 59 Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats 60 EXTERIOR FINISHING Finishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied @ 1.43 liter/10sqm over and including priming coat of water exterior paint applied @ 2.20kg/10sqm) 61 Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge. 62 Providing and fixing Inaguration stone of granite(size 30x20) incl. engraving writing and fixing in wall including Construction of Pedestal Complete Job) : 63 Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix) 64 Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable materialwithin 50 meters lead as per direction of Engineer-in-charge: In cement mortar 65 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : Of area of 3 sqm. and below 66 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 meters lead. 67 Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of :G.S. Sheet 68 Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofingcompound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer in-charge. 69 With average thickness of 120mm and minimum thickness at khurra as 65 mm 70 10cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa at 35kg per cum of earth and gobri leaping with mix 1:1 (1 clay: 1 cow dung) and covered with specified tile bricks grouted with cement mortar 1:3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finishing neat. With common burnt clay (non modular) brick tiles of class designation 10.0 71 Carriage of Materials By Mechanical Transport including loading, unloading and stacking 72 Lime, moorum, building rubbish 73 Earth 74 Sand, stone aggregate below 40 mm nominal size 75 Sand for brick work and plaster 76 Sand for rcc / cc work 77 Stone aggregate 40 mm nominal size and above 78 Stone Aggregate below 40 mm nominal size 79 Bricks -Lead 140 km( 535.30 + (41.77 x 5) + (34.90 x 10) + (29.43 x120) =4624.75) OR 4.62 PER BRICK 80 By Manual Labour including loading, unloading and stacking for lead less than 0.50 km 81 Lime, moorum, building rubbish 82 EARTH 83 Sand 84 Sand, stone aggregate below 40 mm nominal size 85 Stone aggregate 40 mm nominal size and above 86 Bricks 87 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 88 White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 89 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid. 90 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 91 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 92 Providing and fixing mirror of superior glass (of approved quality) and ofrequired shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing 93 Rectangular shape 1500x450 mm 94 Providing and fixing toilet paper holderwith Flap made out of C.P Brass 95 Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms. . 96 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge 97 Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 98 Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 99 Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931 100 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 101 Providing and fixing on wall face and on ground un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring confirming to IS:5283 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 102 75mm diametre 103 110 mm diameter 104 Providing and fixing on wall face and on ground un-plasticized - PVC moulded fittings / accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 105 Coupler 106 75 mm 107 110 mm 108 Bend 87.5° 109 75 mm bend 110 110 mm bend 111 Shoe (plain) 112 75 mm shoe 113 110 mm shoe 114 Providing and Fixing of Floor Traps 110 mm with double chrome plated Cover one Grated and one closed and all other fittings required. 115 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominalsize), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished withfloating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as perstandard design : 116 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg andweight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 117 Supply, Installation of PVC Gully Trap of Size 110 mm 118 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipesand fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.(SDR-11) Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good thewall etc. 119 15mm nominal outer dia pipes 120 20mm nominal outer dia pipes 121 25mm nominal outer dia pipes 122 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipesand fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge Internal work-exposed on wall with clamps at 1.00 meter spacing 123 25mm nominal outer dia pipes. 124 20mm nominal outer dia pipes 125 External work including trenching and refilling etc. complete 126 40mm nominal outer dia pipes. 127 Providing and fixing unplasticised PVC connection pipe with brass unions: 45 cm length 128 15 mm nominal bore 129 Cutting holes upto 30x30 cm in walls including making good the same with common burnt clay F.P.S.(non modular) bricks 130 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 16 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.32 mm Diameter 131 Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brickhoney comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design 132 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 133 Supply,Installation,Testing and Commissioning ofwater Pump with a Discharge of 6.0 Cu.m/hr @Head of 45 MetersComplete with all accessories including header Pipes, allied materials and Control Panel. 134 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required. Group A 135 Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required. 136 Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required. 137 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 138 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 139 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 140 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 141 Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required 142 Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required. 143 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 Amodular switch, connections etc. as required. 144 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. 145 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, Ccurve including connections, painting etc. as required. 146 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 147 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessedconduit as required. 148 25 mm 149 40 mm 150 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 151 6 way (4 + 18), Double door 152 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 153 12 way , Double door 154 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, Ccurve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 155 Single Pole 156 Single pole and neutral 157 Supplying and fixing 40 A to 63 Arating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral 158 Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.B in the existing MCB DB complete with connections, testing and commissioning etc. as required. 159 40 A F.P MCB 10 Ka C Curve 160 32 A F.P MCB 10 Ka C Curve 161 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 162 Supplying,installation,Testing&CommissioningofStreetlightLEDfixture powdercoatedpressurediecastaluminumbody withdriver as per the requirement with Driver efficiency >85%,Input voltage: 140-270 VoltAC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5KVL,N,EasperIEC61000-4-5,Driverefficiency >85%,THD< 10%asperIEC61000-3-2,P. F.≥0.95,IP 66,IK-10,CRI>80,undervoltageandovervoltageprotection,EMIEMCAsper CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry)ofminimum 50000BurningHourswith70%ofinitial Lumenmaintained tilllife ends as per LM80 extrapolation IES TM-21-11 report,CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K(AsperANSIBin),SDCM(Standard Deviation Color Matching) <5,Maximumpowerconsumption should not more than the specified rating and Fixture shall be of relevant BIS standardcompleteinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105 <120lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C). 120 watt 163 Supply installation testing and commissioning ofCeiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required.1200 MM 164 Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body materialand construction as per IS : 10322 withdriver (Replaceable)as per the requirement with Driver efficiency >85% ,Operating voltage AC140-270 Volt,freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI>80, Flicker free, (flickershould be below 5 %), life time (LED,Driver & electrical circuitary), ofminimum 50000BurningHourswith,70%ofinitial Lumenmaintained tilllife ends, CCT3000°K/ 4000°K / 5700°K/6000°K/6500°K(AsperANSIBin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BISstandard andtrade markcertificate(T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. completeinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy≥105 <120lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures asper BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C).Powdercoated die cast/ Extrudedaluminium Body (Thickness≥ 1.20 mm) 40 watt 165 Supply,Installation,Testing and Commissioning 486 Cu.m/Hr. AC220-240Volts, 50 Hzexhaust fan made out ofMetal Body with inbuilt thermo cutoff Protection and Noise Level not exceeding 37 dBof Following Sizes including connection etc. complete as required . 300 mm 166 Supplying, installation, Testing & Commissioning ofLED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD typeof following body materialwith PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 degto40degcentigrade,internalsurgeprotectionof2.5KVwithShort&Opencircuit protection ,THD < 10% , P. F.≥0.95,IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%),life time (LED,Driver & electrical circuitary), of minimum50000 Burning Hours with70% of initial Lumenmaintained tilllife ends , CCT 3000°K /4000°K/ 5700°K / 6000°K / 6500°K (AsperANSIBin), SDCM (Standard Deviation Color Matching) <3,Maximumpowerconsumptionshouldnotmorethan the specified rating and Fixture shall be confirming to relevant BIS standards andtrade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing Completeinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as requiredwith Minimum 5 year OEM warranty.System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C) Powdercoateddiecast/Extruded aluminum Body including trim 167 12 -15 watt 168 Supply installation testing and commissioning of IP:20 AluminiumBatten 10W-12 W +- 1 W Decorative LED Surface Mounted 2 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The inputvoltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab. 169 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required. 170 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 171 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 172 Supplying,Installation,Testing and Commissioning of Cubical Type Indoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)(BuildingDistributionPanel ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagrambefore start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall beCPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD 173 INCOMER 174 Adj. TMR Based MCCB 100Amps FP Icu=Ics=100%Breaking Capacity 36 KA with Extendable ROH (01 Nos) 175 Adj. TMR Based MCCB 63 Amps FP Icu=Ics=100%Breaking Capacity 36 KA with Extendable ROH 176 150 A,415 Volts 50Hz Aluminium Busbarset of 4 strips 177 100 A,415 Volts 50Hz Aluminium Busbar set of 4 strips 178 Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. 179 OUTGOINGS 180 Manual Changeover 63 A F.P 415 Volts with AC-23 Duty (Front operated) 181 Adj. TMR Based MCCB 63 Amps FP Icu=Ics=100%Breaking Capacity 36 KA with Extendable ROH 182 F.P 32A 10 Ka C Curve MCB 183 D.P 25A 10 Ka C Curve MCB 184 F.P 40A 10 Ka C Curve MCB 185 Load Bearing Members to be made out of 2.0 mm CRCA Sheet. 186 Partitions to be made out of 1.6 mm CRCA Sheet 187 Gland Plates to be 3.0 mm Thick. 188 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 189 63 mm dia (OD-63 mm & ID-51 mm nominal) 190 Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required. 191 3.5 C X 35 Sq.mm A2XFY 192 Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet) 193 3½ X 35 sq. mm (32mm) 194 ELV (Extra Low Voltage) 195 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 196 1 or 2 Module (75mmX75mm) 197 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 198 TV antenna socket outlet 199 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existingsurface/ recessed steel/ PVC conduit as required.